Objective: To evaluate left ventricular regional and global systolic function by measuring left ventricular longitudinal strain (LS) in hypertensive patients with sigmoid-shaped interventricular septum (SIS) by two-di...Objective: To evaluate left ventricular regional and global systolic function by measuring left ventricular longitudinal strain (LS) in hypertensive patients with sigmoid-shaped interventricular septum (SIS) by two-dimensional speckle tracking (2D-STE);in order to explore whether the sigmoid-shaped interventricular septum affects the left ventricular systolic function in patients with hypertension. Methods: Routine echocardiographic parameters were measured in 30 hypertensive patients with SIS (SIS group) and 30 hypertensive patients without SIS (non-SIS group). The left ventricular segments and global LS were measured by 2D-STE, and the two sets of parameters were compared. Results: The value of the thickness of the basal segment of the interventricular septum (IVSBT), the thickness of the middle segment of the interventricular septum (IVSMT) and the ratio of the basal segment of the ventricular septum to the middle segment of the interventricular septum (IVSBT/IVSMT) in SIS group was higher than that in non-SIS group. However, the value of left ventricular outflow tract diameter (LVOTD) in SIS group was lower than that in non-SIS group. There was a significant difference between the two groups (all P Conclusion: SIS affects left ventricular regional systolic function of patients with hypertension. 2D-STE can early evaluate left ventricular longitudinal systolic function in hypertensive patients with SIS.展开更多
We report a challenging case of a 81-year-old male with history of severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum. The presence of anomalies in the sub-annular area can lead to...We report a challenging case of a 81-year-old male with history of severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum. The presence of anomalies in the sub-annular area can lead to valve malpositioning and its consequences. Transcatheter aortic valve implantation(TAVR) in patients with aneurysm of the perimembranous interventricular septum extending into the left ventricular outflow tract has not been previously reported. This case describes a successful transfemoral TAVR with an Edwards SAPIEN XT valve(Edwards Lifesciences, Irvine, CA, United States) with such anomaly.展开更多
文摘Objective: To evaluate left ventricular regional and global systolic function by measuring left ventricular longitudinal strain (LS) in hypertensive patients with sigmoid-shaped interventricular septum (SIS) by two-dimensional speckle tracking (2D-STE);in order to explore whether the sigmoid-shaped interventricular septum affects the left ventricular systolic function in patients with hypertension. Methods: Routine echocardiographic parameters were measured in 30 hypertensive patients with SIS (SIS group) and 30 hypertensive patients without SIS (non-SIS group). The left ventricular segments and global LS were measured by 2D-STE, and the two sets of parameters were compared. Results: The value of the thickness of the basal segment of the interventricular septum (IVSBT), the thickness of the middle segment of the interventricular septum (IVSMT) and the ratio of the basal segment of the ventricular septum to the middle segment of the interventricular septum (IVSBT/IVSMT) in SIS group was higher than that in non-SIS group. However, the value of left ventricular outflow tract diameter (LVOTD) in SIS group was lower than that in non-SIS group. There was a significant difference between the two groups (all P Conclusion: SIS affects left ventricular regional systolic function of patients with hypertension. 2D-STE can early evaluate left ventricular longitudinal systolic function in hypertensive patients with SIS.
文摘We report a challenging case of a 81-year-old male with history of severe calcific aortic valve stenosis and aneurysmal membranous interventricular septum. The presence of anomalies in the sub-annular area can lead to valve malpositioning and its consequences. Transcatheter aortic valve implantation(TAVR) in patients with aneurysm of the perimembranous interventricular septum extending into the left ventricular outflow tract has not been previously reported. This case describes a successful transfemoral TAVR with an Edwards SAPIEN XT valve(Edwards Lifesciences, Irvine, CA, United States) with such anomaly.