This research,by use of RS image_simulating method,simulated apparent reflectance images at sensor level and ground_reflectance images of SPOT_HRV,CBERS_CCD,Landsat_TM and NOAA14_AVHRR’s corresponding bands.These ima...This research,by use of RS image_simulating method,simulated apparent reflectance images at sensor level and ground_reflectance images of SPOT_HRV,CBERS_CCD,Landsat_TM and NOAA14_AVHRR’s corresponding bands.These images were used to analyze sensor’s differences caused by spectral sensitivity and atmospheric impacts.The differences were analyzed on Normalized Difference Vegetation Index(NDVI).The results showed that the differences of sensors’ spectral characteristics cause changes of their NDVI and reflectance.When multiple sensors’ data are applied to digital analysis,the error should be taken into account.Atmospheric effect makes NDVI smaller,and atmospheric correction has the tendency of increasing NDVI values.The reflectance and their NDVIs of different sensors can be used to analyze the differences among sensor’s features.The spectral analysis method based on RS simulated images can provide a new way to design the spectral characteristics of new sensors.展开更多
Sustained release Eudragit RL/RS microspheres encapsulating nifedipine were prepared using the acetone/liquid paraffin emulsion solvent evaporation method. The influence of different preparation factors on release o...Sustained release Eudragit RL/RS microspheres encapsulating nifedipine were prepared using the acetone/liquid paraffin emulsion solvent evaporation method. The influence of different preparation factors on release of the drug in vitro was investigated. The release rate of nifedipine from the microspheres increased with increasing Eudragit RL/RS ratio and stirring rate during the preparation, and with decreasing the polymer concentration of internal phase and microsphere size. It was found that a linear relationship existed between the microsphere size and the time of 50% drug release. The drug release rate increased with increasing nifedipine content from 4.2 to 16.7% and was more rapid than the dissolution rate of pure nifedipine particles. However, the release rate of the microspheres with 26.6% drug content decreased significantly and was slower than the dissolution rate of pure drug particles. This was attributed mainly to the nifedipine dispersion state in the microspheres as confirmed by the differential thermal analysis and X ray diffraction study, which showed that nifedipine was present in an amorphous or molecular state in the microspheres with 4.2, 9.4 and 16.7% drug, whereas partly in the crystalline state in the microspheres with 26.6% drug. The amounts released for less than 70% nifedipine can be fitted to Higuchi square root of time model, independent of polymer ratio, drug content and microsphere size.展开更多
将化工热力学溶液理论和化工流程模拟有机结合,设计了正己烷-甲基环戊烷萃取精馏计算型实验。通过类导体屏蔽电荷真实溶液模型(conductor-like screening model for real solvents,COSMO-RS)计算,基于溶解性、选择性指标筛选离子液体溶...将化工热力学溶液理论和化工流程模拟有机结合,设计了正己烷-甲基环戊烷萃取精馏计算型实验。通过类导体屏蔽电荷真实溶液模型(conductor-like screening model for real solvents,COSMO-RS)计算,基于溶解性、选择性指标筛选离子液体溶剂;通过量子化学计算及屏蔽电荷密度曲线分析溶剂和溶质分子相互作用,探究离子液体促进分离过程的机理;基于筛选的溶剂,利用Aspen Plus软件计算优化萃取分离工艺。该综合实验融合了化工热力学、化工原理和过程系统工程等专业课程内容,同时将学科理论知识与工程实践应用有机结合,强化了专业基本功训练,激发了研究兴趣,提升了创新能力。展开更多
针对飞行模拟器座舱仪表控制系统的结构,为实现在地面模拟真实飞机飞行的目的,研究提出了基于RS 485总线的飞行模拟器座舱仪表控制系统总体结构方案及硬件实现;研究了仪表控制计算机OPC(OLE for Process Control)接口驱动软件和仪表通...针对飞行模拟器座舱仪表控制系统的结构,为实现在地面模拟真实飞机飞行的目的,研究提出了基于RS 485总线的飞行模拟器座舱仪表控制系统总体结构方案及硬件实现;研究了仪表控制计算机OPC(OLE for Process Control)接口驱动软件和仪表通信软件,并对仪表系统采用的混合式步进电机的运动控制进行了研究且给出了相应的控制方法。系统运行表明,基于RS 485总线的飞行模拟器座舱仪表控制系统结构简单,稳定可靠。展开更多
文摘This research,by use of RS image_simulating method,simulated apparent reflectance images at sensor level and ground_reflectance images of SPOT_HRV,CBERS_CCD,Landsat_TM and NOAA14_AVHRR’s corresponding bands.These images were used to analyze sensor’s differences caused by spectral sensitivity and atmospheric impacts.The differences were analyzed on Normalized Difference Vegetation Index(NDVI).The results showed that the differences of sensors’ spectral characteristics cause changes of their NDVI and reflectance.When multiple sensors’ data are applied to digital analysis,the error should be taken into account.Atmospheric effect makes NDVI smaller,and atmospheric correction has the tendency of increasing NDVI values.The reflectance and their NDVIs of different sensors can be used to analyze the differences among sensor’s features.The spectral analysis method based on RS simulated images can provide a new way to design the spectral characteristics of new sensors.
文摘Sustained release Eudragit RL/RS microspheres encapsulating nifedipine were prepared using the acetone/liquid paraffin emulsion solvent evaporation method. The influence of different preparation factors on release of the drug in vitro was investigated. The release rate of nifedipine from the microspheres increased with increasing Eudragit RL/RS ratio and stirring rate during the preparation, and with decreasing the polymer concentration of internal phase and microsphere size. It was found that a linear relationship existed between the microsphere size and the time of 50% drug release. The drug release rate increased with increasing nifedipine content from 4.2 to 16.7% and was more rapid than the dissolution rate of pure nifedipine particles. However, the release rate of the microspheres with 26.6% drug content decreased significantly and was slower than the dissolution rate of pure drug particles. This was attributed mainly to the nifedipine dispersion state in the microspheres as confirmed by the differential thermal analysis and X ray diffraction study, which showed that nifedipine was present in an amorphous or molecular state in the microspheres with 4.2, 9.4 and 16.7% drug, whereas partly in the crystalline state in the microspheres with 26.6% drug. The amounts released for less than 70% nifedipine can be fitted to Higuchi square root of time model, independent of polymer ratio, drug content and microsphere size.
文摘将化工热力学溶液理论和化工流程模拟有机结合,设计了正己烷-甲基环戊烷萃取精馏计算型实验。通过类导体屏蔽电荷真实溶液模型(conductor-like screening model for real solvents,COSMO-RS)计算,基于溶解性、选择性指标筛选离子液体溶剂;通过量子化学计算及屏蔽电荷密度曲线分析溶剂和溶质分子相互作用,探究离子液体促进分离过程的机理;基于筛选的溶剂,利用Aspen Plus软件计算优化萃取分离工艺。该综合实验融合了化工热力学、化工原理和过程系统工程等专业课程内容,同时将学科理论知识与工程实践应用有机结合,强化了专业基本功训练,激发了研究兴趣,提升了创新能力。
文摘针对飞行模拟器座舱仪表控制系统的结构,为实现在地面模拟真实飞机飞行的目的,研究提出了基于RS 485总线的飞行模拟器座舱仪表控制系统总体结构方案及硬件实现;研究了仪表控制计算机OPC(OLE for Process Control)接口驱动软件和仪表通信软件,并对仪表系统采用的混合式步进电机的运动控制进行了研究且给出了相应的控制方法。系统运行表明,基于RS 485总线的飞行模拟器座舱仪表控制系统结构简单,稳定可靠。