To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simula...To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simulation system is composed of several modules such as fault transient calculation,startup,Fourier algorithm,phase selection,impedance computing and impedance comparison etc.Some typical simulation cases,which focus on the main factors affecting distance relay's operation,have been simulated with the system.Simulation results show that the system is able to demonstrate the dynamic behaviors of distance protection under different operating conditions.展开更多
This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission chara...This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.展开更多
New strategies and methods for assessing the security of protection systems to reduce the risk of unnecessary disturbances and blackouts are the main topic of the present paper. The system behavior of a protection sys...New strategies and methods for assessing the security of protection systems to reduce the risk of unnecessary disturbances and blackouts are the main topic of the present paper. The system behavior of a protection system and network is analyzed and assessed as a whole. Hence, the established algorithms are capable to handle complex network structures with regard to an intelligent data management as well as data validation. Protection security assessment comprised two different aspects: on the one hand the behavior regarding dependability and security in terms of speed and sensitivity, on the other hand the behavior regarding the response on dynamic network phenomena as voltage stability and transient stability. A new automated method for assessing the dependability and security of protection systems is shown. The short-circuit simulation tool is used to provide a simulation system including network and protection devices as a whole. The handling of the large amount of resulting data is done by an intelligent visualization method like a “fingerprint” analysis. Further on the paper is focused on the protection response on dynamic network phenomena and presents innovative strategies for this investigation aspect. The structure of simulation environment will be described. Results of a case study show the application of this method on a real network. The system tool which is concluding these two aspects of protection assessment is called SIGUARD? PSA.展开更多
针对海上设施的安全防护问题,提出了一种网-桁架式海上拦截装置,目的是在有效拦截来袭小艇撞击的同时尽量降低对拦截装置本身的损伤.为验证这一装置的有效性,基于显式动力学和欧拉-拉格朗日耦合方法对拦截装置拦截小艇过程进行数值模拟...针对海上设施的安全防护问题,提出了一种网-桁架式海上拦截装置,目的是在有效拦截来袭小艇撞击的同时尽量降低对拦截装置本身的损伤.为验证这一装置的有效性,基于显式动力学和欧拉-拉格朗日耦合方法对拦截装置拦截小艇过程进行数值模拟,设定小艇垂直撞击支撑柱、支撑柱间隙和45°撞击支撑柱、支撑柱间隙4种工况,每种工况包含10、20、30 m/s 3种速度.通过对这12组仿真的碰撞力、能量以及破损状态分析,全方位分析了该装置的防撞性能和对小艇的拦截效果.所有工况下该装置都能完成对小艇的拦截,说明这种装置具有优秀的拦截效果.展开更多
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools....This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.展开更多
基金National Natural Science Foundation of China(No.50777040)
文摘To observe the inner operating process of distance protection,a Matlab/Simulink based dynamic simulation system for microprocessor-based distance protection is designed in this paper.As a modularized design,the simulation system is composed of several modules such as fault transient calculation,startup,Fourier algorithm,phase selection,impedance computing and impedance comparison etc.Some typical simulation cases,which focus on the main factors affecting distance relay's operation,have been simulated with the system.Simulation results show that the system is able to demonstrate the dynamic behaviors of distance protection under different operating conditions.
文摘This paper analyzes characteristics of multi type current transformers hybrid operation for each branch of the bus and their effects on differential protection of the bus. By theoretically analyzing transmission characteristics of multi type current transformers and their influence factors, we study the dynamic model testing method of multi type current transformers for the bus, and design 3 kinds of testing schemes by making the equivalent model based on the field of P-level current transformer, TPY-level current transformer and electronic current transformer, and build the hybrid operation testing platform of multi type current transformers. Finally, we compare and analyze the transmission characteristics difference of multi type current transformers on the same branch and the characteristics difference of hybrid operation in two successive external faults, analyze the cause behind the differences, and put forward the corresponding improvement measures.
文摘New strategies and methods for assessing the security of protection systems to reduce the risk of unnecessary disturbances and blackouts are the main topic of the present paper. The system behavior of a protection system and network is analyzed and assessed as a whole. Hence, the established algorithms are capable to handle complex network structures with regard to an intelligent data management as well as data validation. Protection security assessment comprised two different aspects: on the one hand the behavior regarding dependability and security in terms of speed and sensitivity, on the other hand the behavior regarding the response on dynamic network phenomena as voltage stability and transient stability. A new automated method for assessing the dependability and security of protection systems is shown. The short-circuit simulation tool is used to provide a simulation system including network and protection devices as a whole. The handling of the large amount of resulting data is done by an intelligent visualization method like a “fingerprint” analysis. Further on the paper is focused on the protection response on dynamic network phenomena and presents innovative strategies for this investigation aspect. The structure of simulation environment will be described. Results of a case study show the application of this method on a real network. The system tool which is concluding these two aspects of protection assessment is called SIGUARD? PSA.
文摘针对海上设施的安全防护问题,提出了一种网-桁架式海上拦截装置,目的是在有效拦截来袭小艇撞击的同时尽量降低对拦截装置本身的损伤.为验证这一装置的有效性,基于显式动力学和欧拉-拉格朗日耦合方法对拦截装置拦截小艇过程进行数值模拟,设定小艇垂直撞击支撑柱、支撑柱间隙和45°撞击支撑柱、支撑柱间隙4种工况,每种工况包含10、20、30 m/s 3种速度.通过对这12组仿真的碰撞力、能量以及破损状态分析,全方位分析了该装置的防撞性能和对小艇的拦截效果.所有工况下该装置都能完成对小艇的拦截,说明这种装置具有优秀的拦截效果.
基金supported by CNPQ,FAPERJ and Coordenacao de Aperfeicoamento de Pessoal de Nível Superior–Brasil(CAPES)Finance Code 001。
文摘This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square(RMS)phasor-domain,fundamentalfrequency,three-phase,and dynamic simulation tools.The effectiveness of the proposed controller is assessed with simulations in test systems with high percentage of converter-interfaced generation.The simulations focus on the operation of protection relays that use negative-sequence quantities in their directional elements.This paper also presents and compares two strategies to limit reactive negative-sequence currents,and active and reactive positive-sequence currents.A tutorial test system and a regional system part of the actual Brazilian Interconnected Power System are used to assess the correctness of the proposed controller in three-phase fundamental-frequency RMS dynamic simulations.