期刊文献+
共找到639篇文章
< 1 2 32 >
每页显示 20 50 100
Simultaneous nitrification and autotrophic denitrification in fluidized bed reactors using pyrite and elemental sulfur as electron donors 被引量:1
1
作者 Maria F.Carboni Sonia Arriaga Piet N.L.Lens 《Water Science and Engineering》 EI CAS CSCD 2023年第2期143-153,共11页
In this study, simultaneous nitrification and autotrophic denitrification (SNAD) with either elemental sulfur or pyrite were investigated in fluidized bed reactors in mesophilic conditions. The reactor performance was... In this study, simultaneous nitrification and autotrophic denitrification (SNAD) with either elemental sulfur or pyrite were investigated in fluidized bed reactors in mesophilic conditions. The reactor performance was evaluated at different ammonium (12-40 mg/L of NH4+-N), nitrate (35-45 mg/L of NO3--N), and dissolved oxygen (DO) (0.1-1.5 mg/L) concentrations, with a hydraulic retention time of 12 h. The pyrite reactor supported the SNAD process with a maximum nitrogen removal efficiency of 139.5 mg/(L·d) when the DO concentration was in the range of 0.8-1.5 mg/L. This range, however, limited the denitrification efficiency of the reactor, which decreased from 90.0% ± 5.3% in phases II-V to 67.9% ± 7.2% in phases VI and VII. Sulfate precipitated as iron sulfate (FeSO4/Fe2(SO4)3) and sodium sulfate (Na2SO4) minerals during the experiment. The sulfur reactor did not respond well to nitrification with a low and unstable ammonium removal efficiency, while denitrification occurred with a nitrate removal efficiency of 97.8%. In the pyrite system, the nitrifying bacterium Nitrosomonas sp. was present, and its relative abundance increased from 0.1% to 1.1%, while the autotrophic denitrifying genera Terrimonas, Ferruginibacter, and Denitratimonas dominated the community. Thiobacillus, Sulfurovum, and Trichlorobacter were the most abundant genera in the sulfur reactor during the entire experiment. 展开更多
关键词 PYRITE Elemental sulfur simultaneous nitrification and denitrification Nitrogen removal 16S rRNA
下载PDF
Simultaneous nitrification and denitrification in step feeding biological nitrogen removal process 被引量:19
2
作者 ZHU Gui-bing PENG Yong-zhen +2 位作者 WU Shu-yun WANG Shu-ying XU Shi-wei 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第9期1043-1048,共6页
The simultaneous nitrification and denitrification in step-feeding biological nitrogen removal process were investigated under different influent substrate concentrations and aeration flow rates. Biological occurrence... The simultaneous nitrification and denitrification in step-feeding biological nitrogen removal process were investigated under different influent substrate concentrations and aeration flow rates. Biological occurrence of simultaneous nitrification and denitrification was verified in the aspect of nitrogen mass balance and alkalinity. The experimental results also showed that there was a distinct linear relationship between simultaneous nitrification and denitrification and DO concentration under the conditions of low and high aeration flow rate. In each experimental run the floc sizes of activated sludge were also measured and the results showed that simultaneous nitrification and denitrification could occur with very small size of floc. 展开更多
关键词 biological nitrogen removal dissolved oxygen floc size simultaneous nitrification and denitrification step feeding process
下载PDF
Effects of COD/N ratio and DO concentration on simultaneous nitrification and denitrification in an airlift internal circulation membrane bioreactor 被引量:18
3
作者 Meng Qingjuan Yang Fenglin +1 位作者 Liu Lifen Meng Fangang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第8期933-939,共7页
The effects of chemical oxygen demand and nitrogen(COD/N)ratio and dissolved oxygen concentration(DO)on simultaneous nitrification and denitrification(SND)were investigated using an airlift internal circulation membra... The effects of chemical oxygen demand and nitrogen(COD/N)ratio and dissolved oxygen concentration(DO)on simultaneous nitrification and denitrification(SND)were investigated using an airlift internal circulation membrane bioreactor(AIC-MBR)with synthetic wastewater.The results showed that the COD efficiencies were consistently greater than 90% regardless of changes in the COD/N ratio.At the COD/N ratio of 4.77 and 10.04,the system nitrogen removal efficiency became higher than 70%.However,the nitrogen remova... 展开更多
关键词 simultaneous nitrification and denitrificationsnd chemical oxygen demand and nitrogen(COD/N)ratio dissolved oxygen(DO)concentration
下载PDF
Nitrogen Removal by Simultaneous Nitrification and Denitrification via Nitrite in a Sequence Hybrid Biological Reactor 被引量:12
4
作者 王建龙 彭永臻 +1 位作者 王淑莹 高永青 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第5期778-784,共7页
Sequence hybrid biological reactor (SHBR) was proposed, and some key control parameters were investigated for nitrogen removal from wastewater by simultaneous nitrification and denitrification (SND) via nitrite. S... Sequence hybrid biological reactor (SHBR) was proposed, and some key control parameters were investigated for nitrogen removal from wastewater by simultaneous nitrification and denitrification (SND) via nitrite. SND via nitrite was achieved in SHBR by controlling demand oxygen (DO) concentration. There was a programmed decrease of the DO from 2.50 mg·L^-1 to 0.30 mg·L^-1, and the average nitrite accumulation rate (NAR) was increased from 16.5% to 95.5% in 3 weeks. Subsequently, further increase in DO concentration to 1.50 mg·L^-1 did not destroy the partial nitrification to nitrite. The results showed that limited air flow rate to cause oxygen deficiency in the reactor would eventually induce only nitrification to nitrite and not further to nitrate. Nitrogen removal efficiency was increased with the increase in NAR, that is, NAR was increased from 60% to 90%, and total nitrogen removal efficiency was increased from 68% to 85%. The SHBR could tolerate high organic loading rate (OLR), COD and ammonia-nitrogen removal efficiency were greater than 92% and 93.5%, respectively,, and it even operated under low DO concentration (0.5 mg·L^-1) and maintained high OLR (4.0 kg COD·m^-3·d^-1). The presence of biofilm positively affected the activated sludge settling capability, and sludge volume index (SVI) of activated sludge in SHBR never hit more than 90 ml·L^-1 throughout the experiments. 展开更多
关键词 nitrogen removal simultaneous nitrification and denitrification nitrite accumulation demand oxygen PH
下载PDF
Simultaneous nitrification and denitrification by aerobic granular sludge membrane bioreactor for high concentration ammonium nitrogen wastewater 被引量:2
5
作者 Rui CHEN Xiaoli WANG +1 位作者 Yonggang ZHANG Xueqi FU 《Chinese Journal Of Geochemistry》 EI CAS 2006年第B08期130-131,共2页
关键词 废水处理 需氧菌 污泥 硝化作用
下载PDF
Performance of simultaneous nitrification and denitrification in lateral flow biological aerated filter 被引量:1
6
作者 龙腾锐 《Journal of Chongqing University》 CAS 2006年第4期223-228,共6页
A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has ... A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has the function of nitrification and removing organic substrate. In this study, we focused on the denitrification performance of LBAF and its possible mechanism under thorough aeration. We identified the existence of simultaneous nitrification and denitrification (SND) by analyzing nitrogenous compounds along the flow path of LBAF and supportive microbial microscopy, and studied the effects of air/water ratio and hydraulic loading on the performance of nitrogen removal and on SND in LBAF to find out the optimal operation condition. It is found that for saving operation cost, aeration can be reduced to some degree that allows desirable removal efficiency of pollutants, and the optimal air/water ratio is 10:1. Hydraulic loading less than 0.43 m h?1 hardly affects the nitrification and denitrification performance; whereas higher hydraulic loading is unfavorable to both nitrification and denitrification, far more unfavorable to denitrification than to nitrification. 展开更多
关键词 lateral flow biological aerated filter simultaneous nitrification and denitrification air/water ratio hydraulic loading
下载PDF
Control strategy of simultaneous nitrification and denitrification in SBR system
7
作者 LOU Ju-qing GUO Mao-xin SHEN Xiao-ming 《Journal of Environmental Science and Engineering》 2008年第5期21-26,共6页
The influence of main process parameters on simultaneous nitrification and denitrification (SND) in a sequencing batch reactor (SBR) were investigated while treating actual municipal sewage. The influent average c... The influence of main process parameters on simultaneous nitrification and denitrification (SND) in a sequencing batch reactor (SBR) were investigated while treating actual municipal sewage. The influent average concentration of CODcr and total nitrogen was 350mg-L-l and 35mg.L-l. The experiment indicated the following four operation control strategies: (1) When operation cycle was 6 hours, oxidation of organic pollutants and simultaneous nitrification and denitrification could well completed in the SBR reactor; (2) TN removal rate could be increased significantly, 40% higher than traditional SBR processes when idle period was set between influent and aeration; (3) The time of idle period could affect simultaneous nitrification and denitrification and the best time is 30 minutes; (4) Increase of sludge organic load may improve TN removal efficiency, but NH3-N removal efficiency declines. 展开更多
关键词 SBR simultaneous nitrification and denitrification IDLE CYCLE sludge load
下载PDF
光驱动SND生化工艺研究
8
作者 杜平 胡定源 +3 位作者 孙茂 陈庆峰 陈瑞 汪辉 《化工管理》 2024年第11期133-138,共6页
为探寻菌藻结合实现光驱动同步硝化反硝化(SND)生化工艺的应用,在自制的AAO+沉淀池的反应器中通过人工配制进水的方式模拟对现实生活污水处理。经过四个月的运行成功实现光驱动SND生化工艺的稳定运行,在提供光照的条件下,降低约42.86%... 为探寻菌藻结合实现光驱动同步硝化反硝化(SND)生化工艺的应用,在自制的AAO+沉淀池的反应器中通过人工配制进水的方式模拟对现实生活污水处理。经过四个月的运行成功实现光驱动SND生化工艺的稳定运行,在提供光照的条件下,降低约42.86%的曝气量出水依旧能达到一级A排放标准。培养过程中污泥产生大量的蛋白质(PN)和多糖(PS),PN/PS由2.89增长到5.05,实现污泥颗粒化,由于颗粒内部氧气传质的影响,实现内层缺氧,外层好氧的结构,为氨化细菌(AOB)、硝化细菌(NOB)和反硝化细菌的生长提供了适宜的场所,从而实现同步硝化反硝化(SND)脱氮过程的运行。根据计算得出,最终培养出的菌藻共生(ABS)系统相比原有系统曝气能耗更低,且具有更大的资源化潜力和脱氮潜力。 展开更多
关键词 光驱动 同步硝化反硝化 菌藻共生 应用潜力
下载PDF
同步硝化内源反硝化除磷好氧颗粒污泥的储存与恢复 被引量:1
9
作者 李军 李嘉睿 +4 位作者 李东岳 吴耀东 梁东博 丁凡 边雪莹 《中国环境科学》 EI CAS CSCD 北大核心 2024年第4期2023-2031,共9页
针对好氧颗粒污泥颗粒化时间慢等问题,进行了同步硝化内源反硝化除磷好氧颗粒污泥常温储存及活性恢复实验研究.结果表明,好氧颗粒污泥经过60d的常温储存后,颗粒的结构基本能保持稳定,但是颗粒污泥的活性大幅度降低,污染物去除率仅有储... 针对好氧颗粒污泥颗粒化时间慢等问题,进行了同步硝化内源反硝化除磷好氧颗粒污泥常温储存及活性恢复实验研究.结果表明,好氧颗粒污泥经过60d的常温储存后,颗粒的结构基本能保持稳定,但是颗粒污泥的活性大幅度降低,污染物去除率仅有储存前的30%~40%.将常温储存的颗粒污泥接种到反应器中,经过一定的调控手段,可以在60d内恢复好氧颗粒污泥的功能及活性.此外,经过储存与恢复,好氧颗粒污泥的群落结构也发生了明显变化.大部分的微生物的相对丰度变化可逆,经过储存和恢复可以恢复至储存前的状态(包括Defluviicoccus(GAOs)和Flavobacterium(PAOs)),重构同步脱氮除磷的微生物群落结构. 展开更多
关键词 好氧颗粒污泥 同步硝化内源反硝化除磷 常温储存 活性恢复 微生物群落结构
下载PDF
结晶磷回收联合A/O工艺处理猪场沼液工艺特性
10
作者 徐微 薛亦婷 +1 位作者 吴成杰 朱结坤 《农业工程学报》 EI CAS CSCD 北大核心 2024年第19期208-216,共9页
厌氧发酵广泛用于猪场废水的前端处理,该过程将产生大量沼液。在中国受土地消纳能力限制,相当一部分猪场沼液不得不经处理后达标排放。猪场沼液含有高浓度污染物,目前仍缺少高效的处理工艺。化学磷回收与A/O工艺均已有较好应用基础,该... 厌氧发酵广泛用于猪场废水的前端处理,该过程将产生大量沼液。在中国受土地消纳能力限制,相当一部分猪场沼液不得不经处理后达标排放。猪场沼液含有高浓度污染物,目前仍缺少高效的处理工艺。化学磷回收与A/O工艺均已有较好应用基础,该研究尝试联合结晶磷回收与A/O系统设计了一套具有工程可行性的猪场沼液处理工艺,并以实际猪场沼液为处理对象,探究了该工艺的污染物去除效能与机制。A/O系统缺氧、好氧反应器水力停留时间(HRT,hydraulic retention time)分别为3.4、8.6 h,硝化液回流比为200%,结晶反应器HRT为15min。试验结果表明,所设计工艺获得了较好的污染物去除效果,TP(总磷)、NH_(4)^(+)-N、TN(总氮)、COD(化学需氧量)的去除率分别达到91.20%、94.67%、83.28%和96.18%;工艺同时实现了磷的高效回收,磷回收率(结晶单元对TP去除的贡献率)达到93.44%。缺氧、好氧单元对COD、TN、NH_(4)^(+)-N的去除贡献率分别为75.24%、47.66%、17.30%与24.76%、30.92%、62.75%;该工艺条件下,缺氧单元发生了明显的厌氧氨氧化过程,好氧单元可能通过同步硝化反硝化、厌氧氨氧化等过程实现了部分TN的去除。结晶单元主要结晶产物为MgNH_(4)PO_(4),同步去除了部分TN、NH_(4)^(+)-N,去除贡献率分别为21.39%、19.92%。该研究可为猪场沼液处理及资源回收提供参考。 展开更多
关键词 沼液 A/O生物脱氮 厌氧氨氧化 部分反硝化 同步硝化反硝化 MAP磷结晶
下载PDF
不同粒径零价铁对微氧脱氮系统的影响 被引量:1
11
作者 于雅楠 张潇 +4 位作者 岳秀萍 赵博玮 周爱娟 崔颖 邢剑波 《工业水处理》 CAS CSCD 北大核心 2024年第4期84-97,共14页
构建了部分硝化反硝化厌氧氨氧化(SNAD)微氧体系,并定期向体系内投加120 mg不同粒径的零价铁(ZVI),从反应器运行情况、微生物性能以及群落结构来探究不同粒径ZVI对微氧系统的影响。研究结果表明,在50 nm粒径ZVI(50 nZVI)的介导下,系统的... 构建了部分硝化反硝化厌氧氨氧化(SNAD)微氧体系,并定期向体系内投加120 mg不同粒径的零价铁(ZVI),从反应器运行情况、微生物性能以及群落结构来探究不同粒径ZVI对微氧系统的影响。研究结果表明,在50 nm粒径ZVI(50 nZVI)的介导下,系统的TIN去除率最终稳定在83.591%,电子传递活性(ETSA)是接种污泥的1.48倍,均高于其他粒径ZVI的影响。越小粒径ZVI越能促进胞外聚合物的产生,有利于活性污泥结构稳定。这都源于粒径越小的ZVI更容易被微生物吸附、利用。微生物群落结构与功能分析结果表明,在粒径越小的ZVI介导下的微生物群落多样性越高,群落结构也越复杂。ZVI介导会促进对氧需求不敏感的微生物的富集,样品中主要检测出Candidatus_Brocadia和Candidatus_Kuenenia两种厌氧氨氧化菌(AnAOB),且在50 nZVI影响下丰度最高,分别为4.650%和0.692%。nZVI介导下,AnAOB与Gemmobacter和norank_f_Comamonadaceae两种兼性厌氧型反硝化菌共同作用构成SNAD的脱氮途径。而在mZVI介导下,兼性厌氧型反硝化为主要脱氮途径。 展开更多
关键词 微氧 部分硝化反硝化厌氧氨氧化系统 零价铁 电子传递活性 生物脱氮
下载PDF
沼液二级生化出水铁硫协同同步硝化-自养反硝化深度脱氮 被引量:1
12
作者 欧阳创 宋立杰 +4 位作者 薛罡 徐磊 陈红 李响 张艾 《净水技术》 CAS 2024年第7期100-110,共11页
针对沼液二级生化出水仍含高浓度硝态氮(NO-3-N)、氨氮等问题,文中研究了铁硫协同同步硝化-自养反硝化的影响因素。结果表明,在无外加碳源的条件下,铁硫协同同步硝化反硝化可有效提高TN、NO^(-)_(3)-N和氨氮的去除率。同时,在S/N为2的... 针对沼液二级生化出水仍含高浓度硝态氮(NO-3-N)、氨氮等问题,文中研究了铁硫协同同步硝化-自养反硝化的影响因素。结果表明,在无外加碳源的条件下,铁硫协同同步硝化反硝化可有效提高TN、NO^(-)_(3)-N和氨氮的去除率。同时,在S/N为2的条件下,对TN、NO^(-)_(3)-N、氨氮去除率分别达到51.25%、83.63%、67.33%。氮去除动力学结果表明,TN去除规律在0~15 h内符合一级反应动力学特征,且其反应速率常数(0.0510 h^(-1))大于不投铁硫的空白组(0.0355 h^(-1))。微生物群落演变规律表明,铁刨花及硫代硫酸钠的投加会使微生物群落丰富度提高、多样性降低,且投加铁硫可显著提高自养反硝化菌[硫杆菌属(Thiobacillus)、铁杆菌属(Ferribacterium)]及异养反硝化菌[聚糖菌属(Defluviicoccus)、Candidatus_Competibacter、陶厄氏菌属(Thauera)]的丰度。 展开更多
关键词 沼液 二级生化出水 同步硝化-自养反硝化 深度脱氮
下载PDF
有机碳源对同时硝化/反硝化(SND)过程的影响 被引量:35
13
作者 胡宇华 丁富新 +3 位作者 范轶 陈筛林 杨海光 邢新会 《环境工程》 CAS CSCD 北大核心 2001年第4期17-20,共4页
究了同时硝化 反硝化 (SimultaneousNitrificationandDenitrification ,SND)体系中有机碳源对氨氮去除的影响。实验结果表明 ,在氨氮初始浓度为 35mg L时 ,存在使氨氮降解率达到 99 5 %以上的有机碳源浓度区间 ,其CODCr浓度为40 0mg L~... 究了同时硝化 反硝化 (SimultaneousNitrificationandDenitrification ,SND)体系中有机碳源对氨氮去除的影响。实验结果表明 ,在氨氮初始浓度为 35mg L时 ,存在使氨氮降解率达到 99 5 %以上的有机碳源浓度区间 ,其CODCr浓度为40 0mg L~ 10 0 0mg L ;为保证反应后期体系中C N维持在微生物所需的水平 ,提出了补料的方式 ,使得氨氮降解不会出现停滞阶段 ,可以达到较好的去除效果 ;在周期为 8h的连续序批式 (SBR)操作中 ,采用较高的有机碳源初始进料值 ,并在反应过程中进行补料 ,可以很好的将出水氨氮的浓度维持在较低值 (<5mg L) 展开更多
关键词 有机碳源 同时硝化 反硝化 snd 补料方式 序批式操作 SBR 废水处理 生物除氮
下载PDF
在SBBR中接种硝化菌时SND特性及机理 被引量:9
14
作者 徐伟锋 孙力平 +1 位作者 张芳 顾国维 《水处理技术》 CAS CSCD 北大核心 2005年第4期21-23,34,共4页
通过加硝化菌与未加硝化菌的对比试验,对序批式生物膜法(SB BR)中所表现出来的脱氮特性进行了试验分析,研究探讨生物膜法SN D脱氮的机理:好氧情况下生物膜的吸附作用为反硝化菌提供碳源和能源;SN D反应主要发生在好氧生物膜层和兼性生... 通过加硝化菌与未加硝化菌的对比试验,对序批式生物膜法(SB BR)中所表现出来的脱氮特性进行了试验分析,研究探讨生物膜法SN D脱氮的机理:好氧情况下生物膜的吸附作用为反硝化菌提供碳源和能源;SN D反应主要发生在好氧生物膜层和兼性生物膜分界内;在深层的反硝化菌利用生物膜中储存的有机物作为有机碳源,将好氧生物膜中产生的N O3--N转化为N2。同时加入一定量的硝化菌能较好地提高硝化、脱氮率。 展开更多
关键词 snd 机理 序批式生物膜法 接种 反硝化菌 好氧生物膜 对比试验 试验分析 吸附作用 有机碳源 有机物 脱氮率 分界
下载PDF
A/O生物脱氮工艺处理生活污水中试(二)系统性能和SND现象的研究 被引量:15
15
作者 马勇 彭永臻 于德爽 《环境科学学报》 CAS CSCD 北大核心 2006年第5期710-715,共6页
应用A/O中试装置处理实际生活污水,研究了低DO浓度下系统对有机物、氨氮和总氮的去除效果.研究结果表明,低DO浓度下COD和氨氮的平均去除率分别为85%和92%.由于进水C/N比仅为2.93,总氮平均去除率仅为64%,但提高亚硝酸氮积累率可以提高总... 应用A/O中试装置处理实际生活污水,研究了低DO浓度下系统对有机物、氨氮和总氮的去除效果.研究结果表明,低DO浓度下COD和氨氮的平均去除率分别为85%和92%.由于进水C/N比仅为2.93,总氮平均去除率仅为64%,但提高亚硝酸氮积累率可以提高总氮去除率,当亚硝化率从15%增加到85%,总氮去除率将增加12%.氨氮去除率和硝化速率、总氮去除率具有较好的相关性.维持低DO浓度可以实现亚硝酸型同步硝化反硝化反应,基于氮的物料平衡可知它占系统总氮去除率的5%~12%,增加DO浓度将破坏同步硝化反硝化(SND)现象. 展开更多
关键词 A/O生物脱氮工艺 生活污水 DO 中试 同步硝化反硝化反应
下载PDF
曝气动力双侧横向内循环反应器数值模拟和脱氮机理
16
作者 刘烨星 于莉芳 +3 位作者 陈倩伊 戴步峰 曹皖 彭党聪 《中国环境科学》 EI CAS CSCD 北大核心 2024年第10期5490-5498,共9页
提出一种新型曝气动力双侧横向内循环(ADTL)反应器以免除常规生物脱氮工艺的内循环能耗,借助计算流体力学(CFD)优化ADTL反应器关键结构参数,如顶间隙高度/液位高度(H_(tc)/H_(l))、底间隙高度/液位高度(H_(bc)/H_(l))及A/O比,并考察ADT... 提出一种新型曝气动力双侧横向内循环(ADTL)反应器以免除常规生物脱氮工艺的内循环能耗,借助计算流体力学(CFD)优化ADTL反应器关键结构参数,如顶间隙高度/液位高度(H_(tc)/H_(l))、底间隙高度/液位高度(H_(bc)/H_(l))及A/O比,并考察ADTL反应器处理模拟城市污水的脱氮性能、功能菌活性、酶活性以及微生物群落结构的影响规律.CFD数值模拟结果显示,当H_(tc)/H_(l)、H_(bc)/H_(l)与A/O比分别为0.08、0.08及1:1时,ADTL反应器循环液速与液体流动均匀性较优.ADTL反应器运行结果表明,与常规内循环模式相比,ADTL运行模式TN去除率提高了11.96%,亚硝酸盐氧化比活性/氨氧化比活性(SNUR/SAUR)由1.71降低至1.13,亚硝酸盐还原比活性/硝酸盐还原比活性(NIRR/NARR)由0.39增加至0.66,酶活性比值变化同活性比值变化趋势一致;同时Illumina MiSeq测序结果表明,ADTL阶段中具有亚硝酸盐还原功能的Levilinea(21.58%)、Melioribacter(4.54%)和Burkholderia(1.71%)菌属丰度显著增加,而具有硝酸盐还原功能的Azospira(0%)、Denitratisoma(1.49%)、Dechloromonas(0.84%)丰度则相对较低.因此,ADTL反应器可以在免除内循环能耗的前提下,有效避免“亚硝酸盐循环”,节约硝化过程中的曝气能耗和反硝化过程中的碳源需求,为城市污水处理厂提质增效提供技术支持. 展开更多
关键词 双侧横向内循环 数值模拟 溶解氧梯度分布 同步硝化反硝化 亚硝酸盐循环
下载PDF
溶解氧和污泥粒径分布对城市污水SND影响 被引量:9
17
作者 王川 聂会元 +1 位作者 左金龙 李桥 《土木建筑与环境工程》 CSCD 北大核心 2010年第3期145-148,154,共5页
为了进一步探讨同步硝化反硝化的反应机理,采用SBR工艺,考察溶解氧和污泥粒径分布对城市污水同步硝化反硝化的影响。结果表明:低溶解氧(平均DO=0.5~0.8 mg/L)条件下,氮平衡计算证实SBR工艺发生了明显的SND现象,总氮中大约23.11%的氮是通... 为了进一步探讨同步硝化反硝化的反应机理,采用SBR工艺,考察溶解氧和污泥粒径分布对城市污水同步硝化反硝化的影响。结果表明:低溶解氧(平均DO=0.5~0.8 mg/L)条件下,氮平衡计算证实SBR工艺发生了明显的SND现象,总氮中大约23.11%的氮是通过SND现象去除的。当DO浓度为0.5 mg/L时,硝态氮生成量与氨氮的减少量之比为0.454,硝化速率与反硝化速率基本相当。当DO浓度为4.296 mg/L时,硝化反应产生的氨氮的减少量与硝态氮的生成量相等,此时基本不发生SND现象。当SND发生时,污泥菌胶团颗粒的平均颗粒粒径仅为5.02μm^6μm,说明SND不是单纯的"微环境作用"的结果。 展开更多
关键词 溶解氧 污泥粒径分布 同步硝化反硝化 硝化速率 反硝化速率
下载PDF
DO对亚硝酸型SND的影响 被引量:4
18
作者 张立秋 张可方 +3 位作者 张朝升 方茜 李淑更 凌忠勇 《水处理技术》 CAS CSCD 北大核心 2008年第8期29-33,共5页
采用序批式生物膜反应器(Sequencing batch biofilm reactor,SBBR)处理南方地区城市污水,应用亚硝酸型同步硝化反硝化(SND)技术进行强化生物脱氮。在进水TN30mg·L-1、COD150~250mg·L-1、pH值7.20~7.60及常温(24~29℃)等条... 采用序批式生物膜反应器(Sequencing batch biofilm reactor,SBBR)处理南方地区城市污水,应用亚硝酸型同步硝化反硝化(SND)技术进行强化生物脱氮。在进水TN30mg·L-1、COD150~250mg·L-1、pH值7.20~7.60及常温(24~29℃)等条件下,研究了DO与TN去除率和亚硝酸盐氮积累率的关系。试验结果表明,在40~100L·h-1曝气量下均会得到稳定的亚硝酸型SND,当曝气量增加到120L·h-1时,会向全程硝化转化。曝气量60L·h-1时为SBBR反应器的最佳曝气条件,脱氮效果更好,亚硝酸盐氮积累率可达89.7%,TN去除率最高可达87.8%。 展开更多
关键词 SBBR 亚硝酸型snd 亚硝酸盐氮积累率 TN 曝气量
下载PDF
进水C/N对富集聚磷菌的SNDPR系统脱氮除磷的影响 被引量:20
19
作者 戴娴 王晓霞 +1 位作者 彭永臻 王淑莹 《中国环境科学》 EI CAS CSCD 北大核心 2015年第9期2636-2643,共8页
为了解富集聚磷菌(PAOs)的同步硝化反硝化除磷(SNDPR)系统的脱氮除磷特性,采用延时厌氧(180min)/低氧(溶解氧0.5-1.0mg/L)运行的SBR反应器,以实际生活污水为处理对象,通过投加固态乙酸钠调节进水C/N值(约为11,8,4,3),考察其... 为了解富集聚磷菌(PAOs)的同步硝化反硝化除磷(SNDPR)系统的脱氮除磷特性,采用延时厌氧(180min)/低氧(溶解氧0.5-1.0mg/L)运行的SBR反应器,以实际生活污水为处理对象,通过投加固态乙酸钠调节进水C/N值(约为11,8,4,3),考察其对系统脱氮除磷特性及同步硝化反硝化(SND)脱氮率的影响.结果表明:C/N对系统的除磷性能没有影响,出水PO4^3--P浓度均稳定在0.3mg/L左右,这是由于系统内聚磷菌(PAOs)含量高,且在低氧段可同时发生好氧吸磷与反硝化吸磷.随着C/N的增大,出水NH4^+-N浓度升高,C/N下降时,出水NO^3--N浓度升高.此外,随着C/N的减小,厌氧段反硝化所消耗的COD占进水COD的比例增大,SND可利用的内碳源-PHAs储存量减少,但PHV的利用率增加;当C/N为4-8时,SND现象最明显,SND脱氮率达50.8%,而其它C/N条件下,SND脱氮率都有相应程度的减弱.C/N为8时,系统出水综合指标最好,TN去除率高达80.8%. 展开更多
关键词 同步硝化反硝化除磷 聚羟基脂肪酸—PHA 聚磷菌 低溶解氧 C/N
下载PDF
不同厌氧时间对富集聚磷菌的SNDPR系统处理性能的影响 被引量:18
20
作者 戴娴 彭永臻 +1 位作者 王晓霞 王淑莹 《中国环境科学》 EI CAS CSCD 北大核心 2016年第1期92-99,共8页
在延时厌氧(3h)/低氧(2.5h,溶解氧0.5~1.0mg/L)条件下运行的富集聚磷菌的同步硝化反硝化(SNDPR)系统中,以城市生活污水为处理对象,研究了不同厌氧时间(3.5,3,2,1.5h)对系统内碳源贮存以及脱氮除磷效果的影响.试验结果表明:厌... 在延时厌氧(3h)/低氧(2.5h,溶解氧0.5~1.0mg/L)条件下运行的富集聚磷菌的同步硝化反硝化(SNDPR)系统中,以城市生活污水为处理对象,研究了不同厌氧时间(3.5,3,2,1.5h)对系统内碳源贮存以及脱氮除磷效果的影响.试验结果表明:厌氧时间为3.5h,反应器脱氮效果最好.厌氧时间为3h时,反应器除磷效果最好,出水PO43-浓度为0.35mg/L.厌氧时间从1.5h逐渐上升到3.5h时,厌氧末贮存的聚羟基脂肪酸-PHAs的量也随之增加;当厌氧时间从3h升至3.5h时,释P量反而下降,出水P浓度反而升高.这说明增加厌氧时间有利于强化内碳源贮存,但过长的厌氧时间反而不利聚磷菌种群的富集.运行51个周期之后在厌氧时间为1.5h和2h的反应器内出现非丝状菌膨胀;反应周期内p H值的变化曲线可以作为反应各个过程的指示参数. 展开更多
关键词 同步硝化反硝化除磷 聚羟基脂肪酸—PHAs 聚磷菌 厌氧时间 非丝状菌膨胀
下载PDF
上一页 1 2 32 下一页 到第
使用帮助 返回顶部