期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Considerations in the management of single-piece intraocular lenses outside the capsular bag
1
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 Cataract surgery Sulcus intraocular lens implant single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear Cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
下载PDF
Bi-prism-based single-lens three dimensional digital image correlation system with a long working distance: Methodology and application in extreme high temperature deformation test 被引量:6
2
作者 WU LiFu YIN YuanJie +4 位作者 ZHANG Qi FANG DaiNing ZHANG RuBing ZHU JianGuo XIE HuiMin 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第1期37-50,共14页
As a novel three dimensional digital image correlation (3D DIC) method, the bi-prism-based single lens (BSL) 3D DIC method has been proposed and developed in recent years. Making use ofa bi-prism, this method is a... As a novel three dimensional digital image correlation (3D DIC) method, the bi-prism-based single lens (BSL) 3D DIC method has been proposed and developed in recent years. Making use ofa bi-prism, this method is able to perform a 3D DIC measurement using only a single camera. Thus, the integration level of a BSL 3D DIC system could be much higher than that of the double-camera 3D DIC system. In this paper, using a small-angle bi-prism and a camera with a longer focal length, a special BSL 3D DIC system with a long working distance is designed for measurements in extreme environments. The principle of the system is first studied, and practical methods are then proposed for the system set-up and the determination of system parameters. Then, feasibility of the measurement system is verified by out-of-plane rigid-body translation tests. Finally, the BSL 3D DIC system is proven to be capable of combining with a high-temperature testing instrument to perform deformation tests in a high-temperature environment of up to 1500℃. 展开更多
关键词 three dimensional digital image correlation(3D DIC) single lens bi-prism high temperature deformation measurement
原文传递
Design of Electrostatic Focusing for Space Electron Beam Welding Gun 被引量:2
3
作者 李春旭 何成旦 +1 位作者 许启晋 蒋彩云 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2005年第3期256-262,共7页
The developmental situation of space welding technology at home and abroad is introduced. Then it is put forward that the designing scheme and the computer aided design (CAD) method of main single lens of the domest... The developmental situation of space welding technology at home and abroad is introduced. Then it is put forward that the designing scheme and the computer aided design (CAD) method of main single lens of the domestic space electron beam gun with equal-diameter three-cylinder simple lens, and the flowing-pipe way of calculating the space charge density of the main lens area ,in the electron gun is analyzed. The parameters calculation of the focusing system is completed through Language C utilizing computer programming and a satisfying result is gotten. The result shows that the calculation and design method are correct : the dispersed focusing current of electron beam is less, the beam section is less in the deflected magnetic field, the minimal radius of beam spot on the workpiece is about 0.65615mm, and all these can meet the requirements of the space welding and cutting. 展开更多
关键词 space welding three-cylinder single lens CAD space charge effect
下载PDF