期刊文献+
共找到182篇文章
< 1 2 10 >
每页显示 20 50 100
Current optimization-based control of dual three-phase PMSM for low-frequency temperature swing reduction
1
作者 Linlin Lu Xueqing Wang +3 位作者 Luhan Jin Qiong Liu Yun Zhang Yao Mao 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期238-246,共9页
In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperatur... In this paper,a control scheme based on current optimization is proposed for dual three-phase permanent-magnet synchronous motor(DTP-PMSM)drive to reduce the low-frequency temperature swing.The reduction of temperature swing can be equivalent to reducing maximum instantaneous phase copper loss in this paper.First,a two-level optimization aiming at minimizing maximum instantaneous phase copper loss at each electrical angle is proposed.Then,the optimization is transformed to a singlelevel optimization by introducing the auxiliary variable for easy solving.Considering that singleobjective optimization trades a great total copper loss for a small reduction of maximum phase copper loss,the optimization considering both instantaneous total copper loss and maximum phase copper loss is proposed,which has the same performance of temperature swing reduction but with lower total loss.In this way,the proposed control scheme can reduce maximum junction temperature by 11%.Both simulation and experimental results are presented to prove the effectiveness and superiority of the proposed control scheme for low-frequency temperature swing reduction. 展开更多
关键词 Dual three-phase PMSM Low-frequency temperature swing Copper loss Current optimization Connected neutral points
下载PDF
Attack-resilient Distributed Control for Islanded Single-/three-phase Microgrids Based on Distributed Adaptive Observers
2
作者 Jianguo Zhou Yinliang Xu +1 位作者 Lun Yang Hongbin Sun 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第1期109-119,共11页
This paper investigates the power sharing and voltage regulation issues of islanded single-/three-phase microgrids(S/T-MGs)where both sources and loads are unbalanced and the presence of adversarial cyber-attacks agai... This paper investigates the power sharing and voltage regulation issues of islanded single-/three-phase microgrids(S/T-MGs)where both sources and loads are unbalanced and the presence of adversarial cyber-attacks against sensors of distributed generator(DG)units is considered.Firstly,each DG unit is modeled as a heterogeneous linear dynamic agent with disturbances caused by sources and loads,then the problem is formulated as a distributed containment control problem.After that,to guarantee satisfactory power sharing and voltage control performance asymptotically achieved for the S/T-MGs,an attack-resilient distributed secondary control approach is developed by designing a distributed adaptive observer.With this approach,the effect of the cyber-attacks can be neutralized to ensure system stability and preserve bounded voltage synchronization.Simulation results are presented to demonstrate the effectiveness of the proposed control approach. 展开更多
关键词 single-/three-phase microgrid cyber-attack resilient distributed control distributed observer power sharing
原文传递
Deciphering engineering principle of three-phase interface for advanced gas-involved electrochemical reactions 被引量:2
3
作者 Yanzheng He Sisi Liu +3 位作者 Mengfan Wang Qiyang Cheng Tao Qian Chenglin Yan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第5期302-323,I0008,共23页
As an alternative to conventional energy conversion and storage reactions,gas-involved electrochemical reactions,including the carbon dioxide reduction reaction(CO_(2)RR),nitrogen reduction reaction(NRR)and hydrogen e... As an alternative to conventional energy conversion and storage reactions,gas-involved electrochemical reactions,including the carbon dioxide reduction reaction(CO_(2)RR),nitrogen reduction reaction(NRR)and hydrogen evolution reaction(HER),have become an emerging research direction and have gained increasing attention due to their advantages of environmental friendliness and sustainability.Various studies have been designed to accelerate sluggish kinetics but with limited results.Most of them promote the reaction by modulating the intrinsic properties of the catalyst,ignoring the synergistic effect of the reaction as a whole.Due to the introduction of gas,traditional liquid-solid two-phase reactions are no longer applicable to future research.Since gas-involved electrochemical reactions mostly occur at the junctions of gaseous reactants,liquid electrolytes and solid catalysts,the focus of future research on reaction kinetics should gradually shift to three-phase reaction interfaces.In this review,we briefly introduce the formation and constraints of the three-phase interface and propose three criteria to judge its merit,namely,the active site,mass diffusion and electron mass transfer.Subsequently,a series of modulation methods and relevant works are discussed in detail from the three improvement directions of‘exposing more active sites,promoting mass diffusion and accelerating electron transfer’.Definitively,we provide farsighted insights into the understanding and research of three-phase interfaces in the future and point out the possible development direction of future regulatory methods,hoping that this review can broaden the future applications of the three-phase interface,including but not limited to gas-involved electrochemical reactions. 展开更多
关键词 three-phase reaction Surface reactions Mass diffusion Electron transfer Gas-involved electrochemical reactions
下载PDF
Electrical characteristics of new three-phase traction power supply system for rail transit 被引量:1
4
作者 Xiaohong Huang Hanlin Wang +4 位作者 Qunzhan Li Naiqi Yang Tao Ren You Peng Haoyang Li 《Railway Engineering Science》 2023年第1期75-88,共14页
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.... A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%. 展开更多
关键词 three-phase AC power supply Two-stage power supply structure Electrical characteristics Current distribution Voltage losses Regenerative energy
下载PDF
Speed Regulation Method Using Genetic Algorithm for Dual Three-phase Permanent Magnet Synchronous Motors 被引量:1
5
作者 Xiuhong Jiang Yuying Wang Jiarui Dong 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第2期171-178,共8页
Dual three-phase Permanent Magnet Synchronous Motor(DTP-PMSM)is a nonlinear,strongly coupled,high-order multivariable system.In today’s application scenarios,it is difficult for traditional PI controllers to meet the... Dual three-phase Permanent Magnet Synchronous Motor(DTP-PMSM)is a nonlinear,strongly coupled,high-order multivariable system.In today’s application scenarios,it is difficult for traditional PI controllers to meet the requirements of fast response,high accuracy and good robustness.In order to improve the performance of DTP-PMSM speed regulation system,a control strategy of PI controller based on genetic algorithm is proposed.Firstly,the basic mathematical model of DTP-PMSM is established,and the PI parameters of DTP-PMSM speed regulation system are optimized by genetic algorithm,and the modeling and simulation experiments of DTP-PMSM control system are carried out by MATLAB/SIMULINK.The simulation results show that,compared with the traditional PI control,the proposed algorithm significantly improves the performance of the control system,and the speed output overshoot of the GA-PI speed control system is smaller.The anti-interference ability is stronger,and the torque and double three-phase current output fluctuations are smaller. 展开更多
关键词 Dual three-phase permanent magnet synchronous motor Genetic algorithm PI control Speed regulation
下载PDF
Optimization of Control Loops and Operating Parameters for Three-Phase Separators Used in Oilfield Central Processing Facilities
6
作者 Zhenfeng Li Yaqiao Li Guangjun Wei 《Fluid Dynamics & Materials Processing》 EI 2023年第3期635-649,共15页
In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to... In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to)the typical size of oil and water droplets,the residence time and temperature of fluid and the dosage of demulsifier.Using the“Specification for Oil and Gas Separators”as a basis,the control loops and operating parameters of each separator are optimized Considering the Halfaya Oilfield as a testbed,it is shown that the proposed approach can lead to good results in the production stage. 展开更多
关键词 Distributed control system(DCS) three-phase separator control loop operating parameter
下载PDF
Purification of Moringa oleifera Leaves Protease by Three-Phase Partitioning and Investigation of Its Potential Antibacterial Activity
7
作者 Adam Abdoulaye Agossou D. P. Noumavo +6 位作者 Durand Dah-Nouvlessounon Messan A. B. Ohin Hasan Bayraktar Farid T. Bade Honoré S. Bankole Lamine Baba-Moussa Farid Baba-Moussa 《American Journal of Plant Sciences》 CAS 2023年第1期64-76,共13页
One of plant-based products for dental care is plant-based proteolytic enzymes which are principally proteases. In order not to damage the protein and bioactive content, an efficient method should be employed for thei... One of plant-based products for dental care is plant-based proteolytic enzymes which are principally proteases. In order not to damage the protein and bioactive content, an efficient method should be employed for their purifications. As such, three-phase partitioning (TPP) was used to purify protease from moringa (Moringa oleifera). TPP is an emerging, promising, non-chromatographic and economical technology which is simple, quick, efficient and often one-step process for the separation and purification of bioactive molecules from natural sources. It involves the addition of salt (ammonium sulphate) to the crude extract followed by the addition of an organic solvent (butanol). The protein appears as an interfacial precipitate between upper organic solvent and lower aqueous phases. The various conditions such as ammonium sulphate, ratio of crude extract to t-butanol and pH which are required for attaining efficient purification of the protease fractions were optimized. Under optimized conditions, it was seen that, 35% of ammonium sulphate saturation with 1:0.75 ratio of crude extract to t-butanol at pH 7 gave 4.94-fold purification with 96.20% activity yield of protease in the middle phase of the TPP system. The purified enzyme from Moringa oleifera has no antimicrobial effect on the pathogenic bacteria tested. However, this purified enzyme, can be considered as a promising agent, cheap, and safe source which is suitable for using in various industries. 展开更多
关键词 three-phase Partitioning Moringa oleifera PROTEASE Protein Purification ANTIMICROBIAL
下载PDF
Vibration characteristics of sandwich plates with an auxetic honeycomb core and laminated three-phase skin layers under blast load
8
作者 Quoc-Hoa Pham Van Ke Tran Trung Thanh Tran 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2023年第6期148-163,共16页
In this article,vibration characteristics of sandwich plates with an auxetic honeycomb core and laminated three-phase skin layers subjected to blast load are studied.Higher-order ES-MITC3 element based on higher-order... In this article,vibration characteristics of sandwich plates with an auxetic honeycomb core and laminated three-phase skin layers subjected to blast load are studied.Higher-order ES-MITC3 element based on higher-order shear deformation theory(HSDT)to achieve the governing equations.The sandwich plates with the ultra-light feature of the auxetic honeycomb core layer(negative Poisson’s ratio)and reinforced by two laminated three-phase skin layers.The obtained results in our work are compared with other previously published to confirm accuracy and reliability.In addition,the effects of parameters such as geometrical and material parameters on the vibration characteristics of sandwich plates with an auxetic honeycomb core and laminated three-phase skin layers are fully investigated. 展开更多
关键词 Laminated three-phase Sandwich plate Auxetic honeycomb ES-MITC3 element High-order shear deformation theory
下载PDF
Enhancing ammonia production rates from electrochemical nitrogen reduction by engineering three-phase boundary with phosphorus-activated Cu catalysts
9
作者 Jeehye Kim Cho Hee Lee +5 位作者 Yong Hyun Moon Min Hee Lee Eun Hyup Kim Sun Hee Choi Youn Jeong Jang Jae Sung Lee 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第9期394-401,共8页
Electrochemical N_(2) reduction reaction(eNRR) over Cu-based catalysts suffers from an intrinsically low activity of Cu for activation of stable N_(2) molecules and the limited supply of N_(2) to the catalyst due to i... Electrochemical N_(2) reduction reaction(eNRR) over Cu-based catalysts suffers from an intrinsically low activity of Cu for activation of stable N_(2) molecules and the limited supply of N_(2) to the catalyst due to its low solubility in aqueous electrolytes.Herein,we propose phosphorus-activated Cu electrocatalysts to generate electron-deficient Cu sites on the catalyst surface to promote the adsorption of N_(2) molecules.The eNRR system is further modified using a gas diffusion electrode(GDE) coated with polytetrafluoroethylene(PTFE) to form an effective three-phase boundary of liquid water-gas N_(2)-solid catalyst to facilitate easy access of N_(2) to the catalytic sites.As a result,the new catalyst in the flow-type cell records a Faradaic efficiency of 13.15% and an NH_(3) production rate of 7.69 μg h^(-1) cm^(-2) at-0.2 V_(RHE),which represent 3.56 and 59.2 times increases from those obtained with a pristine Cu electrode in a typical electrolytic cell.This work represents a successful demonstration of dual modification strategies;catalyst modification and N_(2) supplying system engineering,and the results would provide a useful platform for further developments of electrocatalysts and reaction systems. 展开更多
关键词 Electrochemical nitrogen reduction reaction Ammonia production Phosphorous modified copper electrodes Gas diffusion electrodes three-phase boundary PTFE coating
下载PDF
Automatic measurement of three-phase contact angles in pore throats based on digital images
10
作者 ZANG Chuanzhen WANG Lida +3 位作者 ZHOU Kaihu YU Fuwei JIANG Hanqiao LI Junjian 《Petroleum Exploration and Development》 SCIE 2023年第2期442-449,共8页
With the help of digital image processing technology, an automatic measurement method for the three-phase contact angles in the pore throats of the microfluidic model was established using the microfluidic water flood... With the help of digital image processing technology, an automatic measurement method for the three-phase contact angles in the pore throats of the microfluidic model was established using the microfluidic water flooding experiment videos as the data source. The results of the new method were verified through comparing with the manual measurement data.On this basis, the dynamic changes of the three-phase contact angles under flow conditions were clarified by the contact angles probability density curve and mean value change curve. The results show that, for water-wetting rocks, the mean value of the contact angles is acute angle during the early stage of the water flooding process, and it increases with the displacement time and becomes obtuse angle in the middle-late stage of displacement as the dominant force of oil phase gradually changes from viscous force to capillary force. The droplet flow in the remaining oil occurs in the central part of the pore throats, without three-phase contact angle. The contact angles for the porous flow and the columnar flow change slightly during the displacement and present as obtuse angles in view of mean values, which makes the remaining oil poorly movable and thus hard to be recovered. The mean value of the contact angle for the cluster flow tends to increase in the flooding process, which makes the remaining oil more difficult to be recovered. The contact angles for the membrane flow are mainly obtuse angles and reach the highest mean value in the late stage of displacement, which makes the remaining oil most difficult to be recovered. After displacement, the remaining oils under different flow regimes are just subjected to capillary force, with obtuse contact angles, and the wettability of the pore throat walls in the microfluidic model tends to be oil-wet under the action of crude oil. 展开更多
关键词 microfluidic model water flooding experiment digital image processing three-phase contact angle measure-ment method flow regime of the remaining oil
下载PDF
Application of CD34 expression combined with three-phase dynamic contrast-enhanced computed tomography scanning in preoperative staging of gastric cancer
11
作者 Hua Liu Kang-Yan Zhao 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第11期2513-2524,共12页
BACKGROUND Accurate preoperative staging of gastric cancer(GC),a common malignant tumor worldwide,is critical for appropriate treatment plans and prognosis.Dynamic three-phase enhanced computed tomography(CT)scanning ... BACKGROUND Accurate preoperative staging of gastric cancer(GC),a common malignant tumor worldwide,is critical for appropriate treatment plans and prognosis.Dynamic three-phase enhanced computed tomography(CT)scanning for preoperative staging of GC has limitations in evaluating tumor angiogenesis.CD34,a marker on vascular endothelial cell surfaces,is promising in evaluating tumor angiogenesis.We explored the value of their combination for preoperative staging of GC to improve the efficacy and prognosis of patients with GC.Medical records of 106 patients with GC treated at the First People's Hospital of Lianyungang between February 2021 and January 2023 were retrospectively studied.All patients underwent three-phase dynamic contrast-enhanced CT scanning before surgery,and CD34 was detected in gastroscopic biopsy specimens.Using surgical and pathological results as the gold standard,the diagnostic results of three-phase dynamic contrast-enhanced CT scanning at different T and N stages were analyzed,and the expression of CD34-marked microvessel density(MVD)at different T and N stages was determined.The specificity and sensitivity of three-phase dynamic contrast-enhanced CT and CD34 in T and N staging were calculated;those of the combined diagnosis of the two were evaluated in parallel.Independent factors affecting lymph node metastasis were analyzed using multiple logistic regression.RESULTS The accuracy of three-phase dynamic contrast-enhanced CT scanning in diagnosing stages T1,T2,T3 and T4 were 68.00%,75.00%,79.41%,and 73.68%,respectively,and for diagnosing stages N0,N1,N2,and N3 were 75.68%,74.07%,85.00%,and 77.27%,respectively.CD34-marked MVD expression increased with increasing T and N stages.Specificity and sensitivity of three-phase dynamic contrast-enhanced CT in T staging were 86.79%and 88.68%;for N staging,89.06%and 92.86%;for CD34 in T staging,64.15%and 88.68%;and for CD34 in N staging,84.38%and 78.57%,respectively.Specificity and sensitivity of joint diagnosis in T staging were 55.68%and 98.72%,and N staging were 75.15%and 98.47%,respectively,with the area under the curve for diagnosis improving accordingly.According to multivariate analysis,a longer tumor diameter,higher pathological T stage,lower differ-entiation degree,and higher expression of CD34-marked MVD were independent risk factors for lymph node metastasis in patients with GC.CONCLUSION With high accuracy in preoperatively determining the invasion depth and lymph node metastasis of GC,CD34 expression and three-phase dynamic contrast-enhanced CT can provide a reliable basis for surgical resection. 展开更多
关键词 CD34 three-phase dynamic contrast-enhanced computed tomography scanning Gastric cancer Preoperative staging INVASION Lymph node metastasis
下载PDF
Analysis of rock physics response of gas-bearing volcanic reservoir based on three-phase poroelastic theory 被引量:3
12
作者 吴清岭 赵海波 +1 位作者 李来林 范兴才 《Applied Geophysics》 SCIE CSCD 2008年第4期277-283,共7页
Unlike previous theories with velocity and/or elastic modulus averaging, we use a three-phase porous rock physics model developed by Santos for analyzing the seismic response of two immiscible fluids in saturated poro... Unlike previous theories with velocity and/or elastic modulus averaging, we use a three-phase porous rock physics model developed by Santos for analyzing the seismic response of two immiscible fluids in saturated porous media. Considering reservoir reference pressure and coupling drag of two fluids in pores, the effects of frequency, porosity, and gas saturation on the phase velocities of the P-and S-waves are discussed in detail under field conditions. The effects of porosity and gas saturation on Vp/Vs are also provided. The data for our numerical experiments are from a sample of deep volcanic rock from Daqing. The numerical results show that the frequency dispersion effect can be ignored for deep volcanic rocks with low porosity and low permeability. It is concluded that for deep volcanic rocks the effect of gas content in pores on Vp/Vs is negligible but the effect of porosity is significant when there is a certain amount of water contained in the pores. The accurate estimate of lithology and porosity in this case is relatively more important. 展开更多
关键词 rock physics three-phase porous media seismic response and volcanic rock
下载PDF
COMPARISON AND EVALUATION OF CURRENT REFERENCE GENERATION STRATEGIES FOR ACTIVE POWER FILTERS IN THREE-PHASE FOUR-WIRE SYSTEMS
13
作者 陈东华 郭涛 +1 位作者 谢少军 周波 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2005年第4期298-306,共9页
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act... For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result. 展开更多
关键词 active power filters instantaneous reactive power current reference three-phase four wire power
下载PDF
THREE-PHASE BRIDGE INVERTER FOR 9kW DOUBLY SALIENT PERMANENT MAGNET MOTOR
14
作者 黄伟君 秦海鸿 +1 位作者 王慧贞 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第1期27-33,共7页
The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve... The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct. 展开更多
关键词 doubly salient permanent magnet motor three-phase bridge inverter winding back EMF position signal of hall sensor input voltage
下载PDF
Stability analysis of unsaturated soil slope during rainfall infiltration using coupled liquid-gas-solid three-phase model 被引量:13
15
作者 Dong-mei Sun Xiao-min Li +1 位作者 Ping Feng Yong-ge Zang 《Water Science and Engineering》 EI CAS CSCD 2016年第3期183-194,共12页
Generally, most soil slope failures are induced by rainfall infiltration, a process that involves interactions between the liquid phase, gas phase,and solid skeleton in an unsaturated soil slope. In this study, a loos... Generally, most soil slope failures are induced by rainfall infiltration, a process that involves interactions between the liquid phase, gas phase,and solid skeleton in an unsaturated soil slope. In this study, a loosely coupled liquid-gas-solid three-phase model, linking two numerical codes,TOUGH2/EOS3, which is used for water-air two-phase flow analysis, and FLAC^(3D), which is used for mechanical analysis, was established. The model was validated through a documented water drainage experiment over a sandy column and a comparison of the results with measured data and simulated results from other researchers. The proposed model was used to investigate the features of water-air two-phase flow and stress fields in an unsaturated soil slope during rainfall infiltration. The slope stability analysis was then performed based on the simulated water-air two-phase seepage and stress fields on a given slip surface. The results show that the safety factor for the given slip surface decreases first, then increases, and later decreases until the rainfall stops. Subsequently, a sudden rise occurs. After that, the safety factor decreases continually and reaches its lowest value, and then increases slowly to a steady value. The lowest value does not occur when the rainfall stops, indicating a delayed effect of the safety factor. The variations of the safety factor for the given slip surface are therefore caused by a combination of pore-air pressure, matric suction, normal stress, and net normal stress. 展开更多
关键词 COUPLED liquid-gas-solid three-phase model Pore-air pressure UNSATURATED soil slope stability Rainfall INFILTRATION
下载PDF
Three-phase flow of submarine gas hydrate pipe transport 被引量:7
16
作者 李立 徐海良 杨放琼 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第9期3650-3656,共7页
In the hydraulic transporting process of cutter-suction mining natural gas hydrate, when the temperature-pressure equilibrium of gas hydrate is broken, gas hydrates dissociate into gas. As a result, solid-liquid two-p... In the hydraulic transporting process of cutter-suction mining natural gas hydrate, when the temperature-pressure equilibrium of gas hydrate is broken, gas hydrates dissociate into gas. As a result, solid-liquid two-phase flow(hydrate and water) transforms into gas-solid-liquid three-phase flow(methane, hydrate and water) inside the pipeline. The Euler model and CFD-PBM model were used to simulate gas-solid-liquid three-phase flow. Numerical simulation results show that the gas and solid phase gradually accumulate to the center of the pipe. Flow velocity decreases from center to boundary of the pipe along the radial direction. Comparison of numerical simulation results of two models reveals that the flow state simulated by CFD-PBM model is more uniform than that simulated by Euler model, and the main behavior of the bubble is small bubbles coalescence to large one. Comparison of numerical simulation and experimental investigation shows that the values of flow velocity and gas fraction in CFD-PBM model agree with experimental data better than those in Euler model. The proposed PBM model provides a more accurate and effective way to estimate three-phase flow state of transporting gas hydrate within the submarine pipeline. 展开更多
关键词 gas hydrate pipe transport three-phase flow Euler model CFD-PBM model
下载PDF
AmmAmmoximation of Cyclohexanone to Cyclohexanone Oxime Catalyzed by Titanium Silicalite-1 Zeolite in Three-phase System 被引量:7
17
作者 刘国清 吴剑 罗和安 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第5期889-894,共6页
An innovative green process of producing ε-caprolactam was proposed by integrating ammoximation and Beckmann rearrangement effectively. As a first part of the new process, TS-1 molecular sieve-catalyzed synthesis of ... An innovative green process of producing ε-caprolactam was proposed by integrating ammoximation and Beckmann rearrangement effectively. As a first part of the new process, TS-1 molecular sieve-catalyzed synthesis of cyclohexanone oxime from cyclohexanone, ammonia and hydrogen peroxide was carried out in a batch plant. Cyclohexane was used as the solvent in the three-phase reaction system. The influences of essential process parameters on ammoximation were investigated. Under the reaction conditions as catalyst content of 2.5% (by mass); H 2 O 2 /yclohexanone molar ratio of 1.10; NH 3 /cyclohexanone molar ratio of 2.20; reaction temperature of 343 K; reaction time of 5 h, high conversion of cyclohexanone and selectivity to oxime (both>99%) were obtained. Thus, the three-phase ammoximation process showed equal catalytic activity as TS-1 but much more convenient and simpler for the separation of catalyst in comparison to the industrial two-phase system with t-butanol used as solvent. 展开更多
关键词 AMMOXIMATION molecular sieve TS-1 cyclohexanone oxime CYCLOHEXANE three-phase system
下载PDF
Modeling and Analysis of Airlift System Operating in Three-Phase Flow 被引量:6
18
作者 胡东 康勇 +1 位作者 唐川林 王晓川 《China Ocean Engineering》 SCIE EI CSCD 2015年第1期121-132,共12页
Based on the momentum theorem, the fluid governing equation in a lifting pipe is proposed by use of the method combining theoretical analysis with empirical correlations related to the previous research, and the perfo... Based on the momentum theorem, the fluid governing equation in a lifting pipe is proposed by use of the method combining theoretical analysis with empirical correlations related to the previous research, and the performance of an airlift pump can be clearly characterized by the triangular relationship among the volumetric flux of air, water and solid particles, which are obtained respectively by using numerical calculation. The meso-scale river sand is used as tested particles to examine the theoretical model. Results of the model are compared with the data in three-phase flow obtained prior to the development of the present model, by an independent experimental team that used the physical conditions of the present approach. The analytical error can be controlled within 12% for predicting the volumetric flux of water and is smaller than that (±16%) of transporting solid particles in three-phase flow. The experimental results and computations are in good agreement for air-water two-phase flow within a margin of ±8%. Reasonable agreement justifies the use of the present model for engineering design purposes. 展开更多
关键词 airlift pump momentum theorem three-phase flow volumetric flux relative error
下载PDF
Three-Phase Heterojunction NiMo-Based Nano-Needle for Water Splitting at Industrial Alkaline Condition 被引量:9
19
作者 Guangfu Qian Jinli Chen +3 位作者 Tianqi Yu Jiacheng Liu Lin Luo Shibin Yin 《Nano-Micro Letters》 SCIE EI CAS CSCD 2022年第1期325-339,共15页
Constructing heterojunction is an effective strategy to develop high-performance non-preciousmetal-based catalysts for electrochemical water splitting(WS).Herein,we design and prepare an N-doped-carbon-encapsulated Ni... Constructing heterojunction is an effective strategy to develop high-performance non-preciousmetal-based catalysts for electrochemical water splitting(WS).Herein,we design and prepare an N-doped-carbon-encapsulated Ni/MoO_(2) nano-needle with three-phase heterojunction(Ni/MoO_(2)@CN)for accelerating the WS under industrial alkaline condition.Density functional theory calculations reveal that the electrons are redistributed at the three-phase heterojunction interface,which optimizes the adsorption energy of H-and O-containing intermediates to obtain the best ΔG_(H*) for hydrogen evolution reaction(HER)and decrease the ΔG value of ratedetermining step for oxygen evolution reaction(OER),thus enhancing the HER/OER catalytic activity.Electrochemical results confirm that Ni/MoO_(2)@CN exhibits good activity for HER(ƞ_(-10)=33 mV,ƞ_(-1000)=267 mV)and OER(ƞ_(10)=250 mV,ƞ_(1000)=420 mV).It shows a low potential of 1.86 V at 1000 mA cm^(−2) for WS in 6.0 M KOH solution at 60℃ and can steadily operate for 330 h.This good HER/OER performance can be attributed to the three-phase heterojunction with high intrinsic activity and the self-supporting nano-needle with more active sites,faster mass diffusion,and bubbles release.This work provides a unique idea for designing high efficiency catalytic materials for WS. 展开更多
关键词 three-phase heterojunction Interfacial electronic redistribution Catalyst Large current density Water splitting
下载PDF
A new three-phase 5-level current-source inverter 被引量:4
20
作者 BAO Jian-yu BAI Zhi-hong +1 位作者 WANG Qing-song ZHANG Zhong-chao 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第12期1973-1978,共6页
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw... The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly. 展开更多
关键词 three-phase Current-source inverter (CSI) 5-level HARMONICS POD PWM
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部