A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the...A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed method was excellent in the range of 0.5-100 μg·L^-1, the reproducibility (RSD, n=6) were in the range 5.4%-8.9% and detection limits (S/N=3) were 0.3, 0.3, 0.5 and 0.5 μg·L^-1 for 2, 4-dichlorophenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level.展开更多
A rapid headspace single-drop micro-extraction(mix) gas chromatography mass spectrometry(SDMEGC -MS) for the analysis of the volatile compounds in Herba Asari was developed in this study.A mixed solvent of n-tride...A rapid headspace single-drop micro-extraction(mix) gas chromatography mass spectrometry(SDMEGC -MS) for the analysis of the volatile compounds in Herba Asari was developed in this study.A mixed solvent of n-tridecane and butyl acetate(1:1) was finally used for the extraction at 70 C for 15 min with sample amount of 0.750 g and 100 mesh particle size.Under the determined conditions,the pound samples of Herba Asari were directly applied for the analysis.SDME-GC-MS,SPME-GC-MS and SD-GCMS methods were compared and the results showed that SDME-GC-MS method was a simple, inexpensive and effective way to measure the volatile compounds in Herba Asari and could be used for the analysis of volatile compounds in complex samples.展开更多
文摘A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed method was excellent in the range of 0.5-100 μg·L^-1, the reproducibility (RSD, n=6) were in the range 5.4%-8.9% and detection limits (S/N=3) were 0.3, 0.3, 0.5 and 0.5 μg·L^-1 for 2, 4-dichlorophenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level.
文摘A rapid headspace single-drop micro-extraction(mix) gas chromatography mass spectrometry(SDMEGC -MS) for the analysis of the volatile compounds in Herba Asari was developed in this study.A mixed solvent of n-tridecane and butyl acetate(1:1) was finally used for the extraction at 70 C for 15 min with sample amount of 0.750 g and 100 mesh particle size.Under the determined conditions,the pound samples of Herba Asari were directly applied for the analysis.SDME-GC-MS,SPME-GC-MS and SD-GCMS methods were compared and the results showed that SDME-GC-MS method was a simple, inexpensive and effective way to measure the volatile compounds in Herba Asari and could be used for the analysis of volatile compounds in complex samples.