期刊文献+
共找到20,023篇文章
< 1 2 250 >
每页显示 20 50 100
Countermeasure against blinding attack for single-photon detectors in quantum key distribution
1
作者 Lianjun Jiang Dongdong Li +12 位作者 Yuqiang Fang Meisheng Zhao Ming Liu Zhilin Xie Yukang Zhao Yanlin Tang Wei Jiang Houlin Fang Rui Ma Lei Cheng Weifeng Yang Songtao Han Shibiao Tang 《Journal of Semiconductors》 EI CAS CSCD 2024年第4期76-81,共6页
Quantum key distribution(QKD),rooted in quantum mechanics,offers information-theoretic security.However,practi-cal systems open security threats due to imperfections,notably bright-light blinding attacks targeting sin... Quantum key distribution(QKD),rooted in quantum mechanics,offers information-theoretic security.However,practi-cal systems open security threats due to imperfections,notably bright-light blinding attacks targeting single-photon detectors.Here,we propose a concise,robust defense strategy for protecting single-photon detectors in QKD systems against blinding attacks.Our strategy uses a dual approach:detecting the bias current of the avalanche photodiode(APD)to defend against con-tinuous-wave blinding attacks,and monitoring the avalanche amplitude to protect against pulsed blinding attacks.By integrat-ing these two branches,the proposed solution effectively identifies and mitigates a wide range of bright light injection attempts,significantly enhancing the resilience of QKD systems against various bright-light blinding attacks.This method forti-fies the safeguards of quantum communications and offers a crucial contribution to the field of quantum information security. 展开更多
关键词 quantum key distribution single photon detector blinding attack pulsed blinding attack COUNTERMEASURE quan-tum communication
下载PDF
PTW Detector7293种剂量验证方法在调强放射治疗中的对比研究
2
作者 吴晓辉 姚祖文 +4 位作者 徐珊珊 罗桃红 胡小容 姚阳 王晓华 《医疗卫生装备》 CAS 2024年第5期56-59,共4页
目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使... 目的 :对比PTW Detector729 3种验证方法在调强放射治疗(intensity modulated radiation therapy,IMRT)剂量验证中的差异。方法:回顾性选取2022年1—12月于某院完成放射治疗的鼻咽癌、肺癌、乳腺癌、宫颈癌和全脑放射治疗患者共50例,使用PTW Detector729二维电离室矩阵配合PTW RW3固体水与PTW Ocavius 4D旋转模体对50例患者的IMRT计划分别进行归零机架角2D剂量验证、实际机架角2D剂量验证和实际机架角3D剂量验证。将剂量评估阈值设为10%,统计3种验证方法在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种评估标准下的γ通过率。采用SPSS 22.0统计学软件进行数据分析。结果:在10%剂量评估阈值标准下,归零机架角2D剂量验证的γ通过率最高,差异有统计学意义(P<0.05);实际机架角2D剂量验证的γ通过率高于实际机架角3D剂量验证,差异有统计学意义(P<0.05)。3种验证方法的γ通过率在3%/1 mm、2%/2 mm、3%/2 mm和3%/3 mm 4种标准下逐渐升高,且在3%/2 mm标准下均超过90%,结果满足临床放射治疗要求。结论:3种验证方法的验证结果均能达到IMRT剂量验证实践指南要求,根据IMRT开展情况选择合适的验证方法,对确保治疗方案安全、有效实施具有重要意义。 展开更多
关键词 PTW detector729 二维电离室矩阵 剂量验证 γ通过率 调强放射治疗
下载PDF
Low-noise and low-power pixel sensor chip for gas pixel detectors
3
作者 Zhuo Zhou Shi-Qiang Zhou +8 位作者 Dong Wang Xiang-Ming Sun Chao-Song Gao Peng-Zhen Zhu Wei-Ping Ren Jun Liu Mu-Xian Li Chen Lian Chun-Lai Dong 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期142-152,共11页
Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm... Topmetal-M2 is a large-area pixel sensor chip fabricated using the GSMC 130 nm CMOS process in 2021.The pixel array of Topmetal-M2 consists of pixels of 400 rows×512 columns with a pixel pitch of 45μm×45μm.The array is divided into 16 subarrays,with pixels of 400 rows×32 columns per subarray.Each pixel incorporates two charge sensors:a diode sensor and a Topmetal sensor.The in-pixel circuit primarily consists of a charge-sensitive amplifier for energy measurements,a discriminator with a peak-holding circuit,and a time-to-amplitude converter for time-of-arrival measurements.The pixel of Topmetal-M2 has a charge input range of~0-3 k e-,a voltage output range of~0-180 mV,and a charge-voltage conversion gain of~59.56μV∕e-.The average equivalent noise charge of Topmetal-M2,which includes the readout electronic system noise,is~43.45 e-.In the scanning mode,the time resolution of Topmetal-M2 is 1 LSB=1.25μs,and the precision is^()7.41μs.At an operating voltage of 1.5 V,Topmetal-M2 has a power consumption of~49 mW∕cm~2.In this article,we provide a comprehensive overview of the chip architecture,pixel working principles,and functional behavior of Topmetal-M2.Furthermore,we present the results of preliminary tests conducted on Topmetal-M2,namely,alpha-particle and soft X-ray tests. 展开更多
关键词 Charge collection Gas detectors Semiconductor detectors X-ray detectors
下载PDF
CVTD: A Robust Car-Mounted Video Text Detector
4
作者 Di Zhou Jianxun Zhang +2 位作者 Chao Li Yifan Guo Bowen Li 《Computers, Materials & Continua》 SCIE EI 2024年第2期1821-1842,共22页
Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted vid... Text perception is crucial for understanding the semantics of outdoor scenes,making it a key requirement for building intelligent systems for driver assistance or autonomous driving.Text information in car-mounted videos can assist drivers in making decisions.However,Car-mounted video text images pose challenges such as complex backgrounds,small fonts,and the need for real-time detection.We proposed a robust Car-mounted Video Text Detector(CVTD).It is a lightweight text detection model based on ResNet18 for feature extraction,capable of detecting text in arbitrary shapes.Our model efficiently extracted global text positions through the Coordinate Attention Threshold Activation(CATA)and enhanced the representation capability through stacking two Feature Pyramid Enhancement Fusion Modules(FPEFM),strengthening feature representation,and integrating text local features and global position information,reinforcing the representation capability of the CVTD model.The enhanced feature maps,when acted upon by Text Activation Maps(TAM),effectively distinguished text foreground from non-text regions.Additionally,we collected and annotated a dataset containing 2200 images of Car-mounted Video Text(CVT)under various road conditions for training and evaluating our model’s performance.We further tested our model on four other challenging public natural scene text detection benchmark datasets,demonstrating its strong generalization ability and real-time detection speed.This model holds potential for practical applications in real-world scenarios. 展开更多
关键词 Deep learning text detection Car-mounted video text detector intelligent driving assistance arbitrary shape text detector
下载PDF
Design and performance evaluation of a large field-of-view dual-particle time-encoded imager based on a depth-of-interaction detector
5
作者 Dong Zhao Xu-Wen Liang +6 位作者 Ping-Kun Cai Wei Cheng Wen-Bao Jia Da-Qian Hei Qing Shan Yong-Sheng Ling Chao Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期1-14,共14页
Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and ne... Time-encoded imaging is useful for identifying potential special nuclear materials and other radioactive sources at a distance.In this study,a large field-of-view time-encoded imager was developed for gamma-ray and neutron source hotspot imaging based on a depth-of-interaction(DOI)detector.The imager primarily consists of a DOI detector system and a rotary dual-layer cylindrical coded mask.An EJ276 plastic scintillator coupled with two SiPMs was designed as the DOI detector to increase the field of view and improve the imager performance.The difference in signal time at both ends and the log of the signal amplitude ratio were used to calculate the interaction position resolution.The position resolution of the DOI detector was calibrated using a collimated Cs-137 source,and the full width at half maximum of the reconstruction position of the Gaussian fitting curve was approximately 4.4 cm.The DOI detector can be arbitrarily divided into several units to independently reconstruct the source distribution images.The unit length was optimized via Am-Be source-location experiments.A multidetector filtering method is proposed for image denoising.This method can effectively reduce image noise caused by poor DOI detector position resolution.The vertical field of view of the imager was(-55°,55°)when the detector was placed in the center of the coded mask.A DT neutron source at 20 m standoff could be located within 2400 s with an angular resolution of 3.5°. 展开更多
关键词 Time-encoded imager Depth-of-interaction detector Dual-particle imaging Hotspot imaging
下载PDF
Effect of multiple coulomb scattering on the beam tests of silicon pixel detectors
6
作者 Lan-Kun Li Ming-Yi Dong +2 位作者 Ze Gao Liang-Cheng-Long Jin Shu-Jun Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期200-207,共8页
In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and perfo... In the research and development of new silicon pixel detectors,a collimated monoenergetic charged-particle test beam equipped with a high-resolution pixel-beam telescope is crucial for prototype verification and performance evaluation.When the beam energy is low,the effect of multiple Coulomb scattering on the measured resolution of the Device Under Test(DUT)must be considered to accurately evaluate the performance of the pixel chips and detectors.This study aimed to investigate the effect of multiple Coulomb scattering on the measured resolution,particularly at low beam energies.Simulations were conducted using Allpix^(2) to study the effects of multiple Coulomb scattering under different beam energies,material budgets,and telescope layouts.The simulations also provided the minimum energy at which the effect of multiple Coulomb scattering could be ignored.Compared with the results of a five-layer detector system tested with an electron beam at DESY,the simulation results were consistent with the beam test results,confirming the reliability of the simulations. 展开更多
关键词 Silicon Pixel detectors Beam Telescope Multiple Coulomb Scattering Spatial Resolution
下载PDF
Study on the Performance of the GRANDProto300 Particle Detector Array by Simulation
7
作者 Fu-Lin Dai Quan-Bu Gou +1 位作者 Xiaoyuan Huang Yi-Qing Guo 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2024年第1期173-177,共5页
The Giant Radio Array for Neutrino Detection(GRAND)is a proposed large-scale observatory designed to detect cosmic rays,gamma-rays,and neutrinos with energies exceeding 100 Pe V.The GRANDProto300 experiment is propose... The Giant Radio Array for Neutrino Detection(GRAND)is a proposed large-scale observatory designed to detect cosmic rays,gamma-rays,and neutrinos with energies exceeding 100 Pe V.The GRANDProto300 experiment is proposed as the early stage of the GRAND project,consisting of a hybrid array of radio antennas and scintillator detectors.The latter,as a mature and traditional detector,is used to cross-check the nature of the candidate events selected from radio observations.In this study,we developed a simulation software called G4GRANDProto300,based on the Geant4 software package,to optimize the spacing of the scintillator detector array and to investigate its effective area.The analysis was conducted at various zenith angles under different detector spacings,including 300,500,600,700,and 900 m.Our results indicate that,for large zenith angles used to search for cosmic-ray in the GRAND project,the optimized effective area is with a detector spacing of 500 m.The G4GRANDProto300 software that we developed could be used to further optimize the layout of the particle detector array in future work. 展开更多
关键词 astroparticle physics instrumentation:detectors (ISM:)cosmic rays
下载PDF
High-speed performance self-powered short wave ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)
8
作者 Aleksei Almaev Alexander Tsymbalov +5 位作者 Bogdan Kushnarev Vladimir Nikolaev Alexei Pechnikov Mikhail Scheglov Andrei Chikiryaka Petr Korusenko 《Journal of Semiconductors》 EI CAS CSCD 2024年第4期56-62,共7页
High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were ... High-speed solar-blind short wavelength ultraviolet radiation detectors based onκ(ε)-Ga_(2)O_(3)layers with Pt contacts were demonstrated and their properties were studied in detail.Theκ(ε)-Ga_(2)O_(3)layers were deposited by the halide vapor phase epitaxy on patterned GaN templates with sapphire substrates.The spectral dependencies of the photoelectric properties of struc-tures were analyzed in the wavelength interval 200-370 nm.The maximum photo to dark current ratio,responsivity,detectiv-ity and external quantum efficiency of structures were determined as:180.86 arb.un.,3.57 A/W,1.78×10^(12) Hz^(0.5)∙cm·W^(-1) and 2193.6%,respectively,at a wavelength of 200 nm and an applied voltage of 1 V.The enhancement of the photoresponse was caused by the decrease in the Schottky barrier at the Pt/κ(ε)-Ga_(2)O_(3)interface under ultraviolet exposure.The detectors demon-strated could functionalize in self-powered mode due to built-in electric field at the Pt/κ(ε)-Ga_(2)O_(3)interface.The responsivity and external quantum efficiency of the structures at a wavelength of 254 nm and zero applied voltage were 0.9 mA/W and 0.46%,respectively.The rise and decay times in self-powered mode did not exceed 100 ms. 展开更多
关键词 κ(ε)-gallium oxide solar-blind shortwave ultraviolet radiation detectors self-powered operation mode
下载PDF
基于InVEST&GEO-detectors模型的会仙湿地生境质量变化及影响因素研究
9
作者 谢玲 陈展图 +2 位作者 蒋瑜 肖小慧 贾艳红 《广西师范大学学报(自然科学版)》 CAS 北大核心 2023年第5期180-190,共11页
喀斯特湿地是广泛分布在喀斯特地区的一种特殊的湿地类型,其生态地位举足轻重,探索喀斯特湿地生境质量变化的影响因素对喀斯特地区生态建设具有重要的意义。本文基于会仙湿地保护区2000和2020年的土地利用数据,通过InVEST模型评估会仙... 喀斯特湿地是广泛分布在喀斯特地区的一种特殊的湿地类型,其生态地位举足轻重,探索喀斯特湿地生境质量变化的影响因素对喀斯特地区生态建设具有重要的意义。本文基于会仙湿地保护区2000和2020年的土地利用数据,通过InVEST模型评估会仙湿地保护区的生境质量,利用地理探测器探测影响会仙湿地保护区生境质量变化的自然和人为因素。研究结果表明:1)研究区2000至2020年建设用地明显扩张,草地和水体显著减少;2)会仙湿地保护区生境质量总体呈现下降的趋势,生境退化度有所上升,生境质量较差的区域主要集中在研究区的北部、中部和东北部;3)地理探测器识别出会仙湿地保护区生境质量空间变化受自然和人为因子的综合作用,主导影响因子是GDP(q为0.135),其次为夜间灯光指数(DMSP)(q为0.053);交互作用探测结果表明,各因子对生境质量影响呈现出双因子增强效果。研究结果有助于揭示会仙湿地保护区生境质量的时空演变过程,可针对会仙湿地生态建设的问题提出可行的应对策略。 展开更多
关键词 生境质量 InVEST模型 地理探测器 时空变化 影响因素 会仙湿地
下载PDF
A High-Efficiency Broadband Superconducting Nanowire Single-Photon Detector with a Composite Optical Structure 被引量:1
10
作者 顾敏 康琳 +6 位作者 张蜡宝 赵清源 郏涛 万超 徐睿莹 杨小忠 吴培亨 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第3期145-148,共4页
Superconducting nanowire single-photon detectors (SNSPDs) with a composite optical structure composed of phase-grating and optical cavity structures are designed to enhance both the system detection efficiency and t... Superconducting nanowire single-photon detectors (SNSPDs) with a composite optical structure composed of phase-grating and optical cavity structures are designed to enhance both the system detection efficiency and the response bandwidth. Numerical simulation by the finite-difference time-domain method shows that the photon absorption capacity of SNSPDs with a composite optical structure can be enhanced significantly by adjusting the parameters of the phase-grating and optical cavity structures at multiple frequency bands. The absorption capacity of the superconducting nanowires reaches 70%, 72%, 60.73%, 61.7%, 41.2%, and 46.5% at wavelengths of 684, 850, 732, 924, 1256, and 1426nm, respectively. The use of a composite optical structure reduces the total filling factor of superconducting nanowires to only 0.25, decreases the kinetic inductance of SNSPDs, and improves the count rates. 展开更多
关键词 LENGTH A High-Efficiency Broadband Superconducting Nanowire single-photon detector with a Composite Optical Structure
下载PDF
Wavelength dependence of intrinsic detection efficiency of NbN superconducting nanowire single-photon detector
11
作者 王勇 李浩 +8 位作者 尤立星 吕超林 王河清 张兴雨 张伟君 周慧 张露 杨晓燕 王镇 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第7期534-537,共4页
Superconducting nanowire single-photon detectors(SNSPDs) have attracted considerable attention owing to their excellent detection performance;however, the underlying physics of the detection process is still unclear.I... Superconducting nanowire single-photon detectors(SNSPDs) have attracted considerable attention owing to their excellent detection performance;however, the underlying physics of the detection process is still unclear.In this study, we investigate the wavelength dependence of the intrinsic detection efficiency(IDE) for NbN SNSPDs.We fabricate various NbN SNSPDs with linewidths ranging from 30 nm to 140 nm.Then, for each detector, the IDE curves as a function of bias current for different incident photon wavelengths of 510–1700 nm are obtained.From the IDE curves, the relations between photon energy and bias current at a certain IDE are extracted.The results exhibit clear nonlinear energy–current relations for the NbN detectors, indicating that a detection model only considering quasiparticle diffusion is unsuitable for the meander-type NbN-based SNSPDs.Our work provides additional experimental data on SNSPD detection mechanism and may serve as an interesting reference for further investigation. 展开更多
关键词 NIOBIUM NITRIDE SUPERCONDUCTING NANOWIRE single-photoN detectors detection mechanism
下载PDF
The intensity detection of single-photon detectors based on photon counting probability density statistics
12
作者 张子静 吴龙 +1 位作者 宋杰 赵远 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期249-254,共6页
Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling... Single-photon detectors possess the ultra-high sensitivity, but they cannot directly respond to signal intensity. Conven- tional methods adopt sampling gates with fixed width and count the triggered number of sampling gates, which is capable of obtaining photon counting probability to estimate the echo signal intensity. In this paper, we not only count the number of triggered sampling gates, but also record the triggered time position of photon counting pulses. The photon counting probability density distribution is obtained through the statistics of a series of the triggered time positions. Then Minimum Variance Unbiased Estimation (MVUE) method is used to estimate the echo signal intensity. Compared with conventional methods, this method can improve the estimation accuracy of echo signal intensity due to the acquisition of more detected information. Finally, a proof-of-principle laboratory system is established. The estimation accuracy of echo signal intensity is discussed and a high accuracy intensity image is acquired under low-light level environments. 展开更多
关键词 single photon detector photon counting low light level
下载PDF
Performance of superconducting nanowire single-photon detector with the fan coupling antenna array
13
作者 王玉珏 丁天 +1 位作者 马海强 焦荣珍 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期63-65,共3页
The performance of superconducting nanowire single-photon detector (SNSPD) involving niobium nitride with the fan coupling antenna array is analyzed. The SNSPD has a high detection efficiency and counting rate. Hydr... The performance of superconducting nanowire single-photon detector (SNSPD) involving niobium nitride with the fan coupling antenna array is analyzed. The SNSPD has a high detection efficiency and counting rate. Hydrogen silsesquioxane and niobium nitride are filled in the gold grating deposited on the substrate in which the fan coupling antenna arrays are embedded. By changing the position of the fan coupling antenna array, the maximum area of optical intensity is obtained and the photon collection efficiency is increased by 26.5 times. The detection efficiency of SNSPD is improved without changing the detection speed. These parameters are important for designing a practical single-photon detector, 展开更多
关键词 surface plasmon polaritons single-photon detector nano-antenna array
下载PDF
Resonant cavity-enhanced quantum dot field-effect transistor as a single-photon detector
14
作者 董宇 王广龙 +6 位作者 王红培 倪海桥 陈建辉 高凤岐 乔中涛 杨晓红 牛智川 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期162-167,共6页
A resonant cavity-enhanced (RCE) quantum dot (QD) field-effect transistor (RCEQDFET) is designed for single- photon detection in this paper. Adding distributed Bragg reflection (DBR) mirrors to the single-phot... A resonant cavity-enhanced (RCE) quantum dot (QD) field-effect transistor (RCEQDFET) is designed for single- photon detection in this paper. Adding distributed Bragg reflection (DBR) mirrors to the single-photon detector (SPD), we improve the light absorption efficiency of the SPD. The effects of the reflectivity of the mirrors, the thickness and light absorption coefficient of the absorbing layer on the detector's light absorption efficiency are investigated, and the resonant cavity is determined by using the air/semiconductor interface as the mirror on the top. Through analyzing the relationship between the refractive index of AlxGal_xAs and A1 component, we choose A1As/Alo.15Gao.85As as the material of the mirror on the bottom. The pairs of A1As/Alo.15Gao.85As film are further determined to be 21 by calculating the reflectivity of the mirror. The detector is fabricated from semiconductor heterostructures grown by molecular beam epitaxy. The reflection spectrum, photoluminescence (PL) spectrum, photocurrent response, and channel current of the detector are tested and the results show that the RCEQDFET-SPD designed in this paper has better performances in photonic response and wavelength selection. 展开更多
关键词 single-photon detector quantum dot field-effect transistor resonant cavity enhanced
下载PDF
Controlling a sine wave gating single-photon detector by exploiting its filtering loophole
15
作者 冯林溪 江木生 +3 位作者 鲍皖苏 李宏伟 周淳 汪洋 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期124-129,共6页
GHz single-photon detector (SPD) is a crucial part in the practical high speed quantum key distribution (QKD) system. However, any imperfections in a practical QKD system may be exploited by an eavesdropper (Eve... GHz single-photon detector (SPD) is a crucial part in the practical high speed quantum key distribution (QKD) system. However, any imperfections in a practical QKD system may be exploited by an eavesdropper (Eve) to collect information about the key without being discovered. The sine wave gating SPD (SG-SPD) based on InGaAs/InP avalanche photodiode, one kind of practical high speed SPD, may also contain loopholes. In this paper, we study the principle and characteristic of the SG-SPD and find out the filtering loophole of the SG-SPD for the first time. What is more, the proof-of-principle experiment shows that Eve could blind and control Bob's SG-SPD by exploiting this loophole. We believe that giving enough attention to this loophole can improve the practical security of the existing QKD system. GHz single-photon detector (SPD) is a crucial part in the practical high speed quantum key distribution (QKD) system. However, any imperfections in a practical QKD system may be exploited by an eavesdropper (Eve) to collect information about the key without being discovered. The sine wave gating SPD (SG-SPD) based on InGaAs/InP avalanche photodiode, one kind of practical high speed SPD, may also contain loopholes. In this paper, we study the principle and characteristic of the SG-SPD and find out the filtering loophole of the SG-SPD for the first time. What is more, the proof-of-principle experiment shows that Eve could blind and control Bob's SG-SPD by exploiting this loophole. We believe that giving enough attention to this loophole can improve the practical security of the existing QKD system. 展开更多
关键词 quantum key distribution sine wave gating single-photon detector quantum hacking practicalsecurity
下载PDF
CsI-bowl:an ancillary detector for exit channel selection inγ-ray spectroscopy experiments 被引量:1
16
作者 Xing-Chi Han Shuo Wang +5 位作者 Hong-Yi Wu Zhi-Huan Li Guo-Zhu Shi Ruo-Fu Chen Yue-Zhao Zhang Shou-Yu Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期32-39,共8页
A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors,... A particle detector array designed for light-charged particles, known as the CsI-bowl, was built for exit channel selection for in-beam γ-ray spectroscopy experiments. This device is composed of 64 CsI(Tl) detectors, organized in a structure reminiscent of a tea-bowl. High quantum efficiency photodiodes, characterized by their minimal mass, were employed to collect scintillation light. Its design, construction, particle identification resolution, and its effectiveness in relation to exit channel selection are described in this paper. In source tests, the optimal figure of merit for the identification of α-particles and γ-rays using the charge comparison method was found to be 3.3 and 12.1 for CsI detectors coupled to photodiodes and avalanche photodiodes, respectively. The CsI-bowl demonstrated effectiveness in identifying particles, specifically the emission of protons and α-particles in the58Ni(19F, xpyn) fusion–evaporation reaction, thereby enabling the selection of the desired exit channels. 展开更多
关键词 Light charged particle detector array Particle identification Charge comparison method
下载PDF
Study on the gamma rays and neutrons energy response optimization of a scintillating fiber detector for EAST with Geant4 被引量:1
17
作者 Wei-Kun Chen Li-Qun Hu +4 位作者 Guo-Qiang Zhong Rui-Jie Zhou Bing Hong Qiang Li Li Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期40-49,共10页
A new scintillating fiber detector inside magnetic shielding tube was designed and assembled for use in the next round of fusion experiments in the experimental advanced superconducting tokamak to provide D–T neutron... A new scintillating fiber detector inside magnetic shielding tube was designed and assembled for use in the next round of fusion experiments in the experimental advanced superconducting tokamak to provide D–T neutron yield with time resolution.In this study,Geant4 simulations were used to obtain the pulse height spectra for ideal signals produced when detecting neutrons and gamma rays of multiple energies.One of the main sources of interference was found to be low-energy neutrons below 10–5 MeV,which can generate numerous secondary particles in the detector components,such as the magnetic shielding tube,leading to high-amplitude output signals.To address this issue,a compact thermal neutron shield containing a 1-mm Cd layer outside the magnetic shielding tube and a 5-mm inner Pb layer was specifically designed.Adverse effects on the measurement of fast neutrons and the shielding effect on gamma rays were considered.This can suppress the height of the signals caused by thermal neutrons to a level below the height corresponding to neutrons above 4 MeV because the yield of the latter is used for detector calibration.In addition,the detector has relatively flat sensitivity curves in the fast neutron region,with the intrinsic detection efficiencies(IDEs)of approximately 40%.For gamma rays with energies that are not too high(<8 MeV),the IDEs of the detector are only approximately 20%,whereas for gamma rays below 1 MeV,the response curve cuts off earlier in the low-energy region,which is beneficial for avoiding counting saturation and signal accumulation. 展开更多
关键词 Sci-Fi detector D–T fusion neutron Thermal neutron shield Energy response GEANT4
下载PDF
Time-Bin Phase-Encoding Measurement-Device-Independent Quantum Key Distribution with Four Single-Photon Detectors
18
作者 唐光召 孙仕海 +2 位作者 陈欢 李春燕 梁林梅 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第12期5-8,共4页
Measurement-device-independent quantum key distribution (MDI-QKD) eliminates all loopholes on detection. 3 loss in the final key for the Previous experiments of time-bin phase-encoding MDI-QKD allow a factor of inc... Measurement-device-independent quantum key distribution (MDI-QKD) eliminates all loopholes on detection. 3 loss in the final key for the Previous experiments of time-bin phase-encoding MDI-QKD allow a factor of incapability of identifying two successive detection events by a single photon detector. Here we propose a new scheme to realize the time-bin phase-encoding MDI-QKD. The polarization states are used to generate the time bins and the phase-encoding states. The factor of loss in the final key is eliminated by using four single photon detectors at the measurement site. We show the feasibility of our scheme with a proof-of-principle experimental demonstration. The phase reference frame is rotated extremely slowly with only passive stabilization measures. The quantum bit error rate can reach 0.8% in the Z-basis and 26.2% in the X-basis. 展开更多
关键词 QKD MDI of Time-Bin Phase-Encoding Measurement-Device-Independent Quantum Key Distribution with Four single-photon detectors in QBER is with
下载PDF
Design of the solar X-ray detector for the Macao Science Satellite-1B 被引量:1
19
作者 YongQiang Shi LianSheng Li +5 位作者 JianWu Chen FuChang Zuo XiaoPing Zhang ZhiWu Mei Li Wang Keke Zhang 《Earth and Planetary Physics》 EI CSCD 2023年第1期125-130,共6页
The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection ... The solar X-ray detector(SXD)onboard the Macao Science Satellite-1B was designed to monitor solar flare bursts and to study the solar activity in the 25th solar cycle.The SXD includes two parts:a soft X-ray detection unit and a hard X-ray detection unit.Both the soft X-ray detection unit and the hard X-ray detection unit include two collimators,two X-ray detectors(a silicon drift detector and a cadmium-zinc-telluride detector),and a processing circuit.Compared with similar instruments,the energy range of the SXD is wider(1–600 ke V)and the energy resolution is better(150 e V at 5.9 ke V,12%at 59.5 ke V,and 3%at 662 keV). 展开更多
关键词 Macao Science Satellite-1B(MSS-1B) solar X-ray detector solar X-ray SPECTROMETER
下载PDF
Review: Practical Use of a Neurophysiological Detector and the Protocol for High-Performance Liquid Chromatography
20
作者 Ilia Brondz 《International Journal of Analytical Mass Spectrometry and Chromatography》 CAS 2023年第1期1-10,共10页
The main aim for discovery and development of the neurophysiological detector was detection of the production’ seats and criminal use of poisons in warfare. Phosphor-organic (PO) substances with acetylcholinesterase-... The main aim for discovery and development of the neurophysiological detector was detection of the production’ seats and criminal use of poisons in warfare. Phosphor-organic (PO) substances with acetylcholinesterase-blocking effects are prohibited in warfare by international law (Geneva Protocol. https://www.un.org/disarmament/wmd/bio/1925-geneva-protocol/). Monitoring PO analogs with acetylcholinesterase-blocking effects and their degradation products in water and soil can provide clues to unlawful production sites and the possible use of POs in warfare. Attempts to analyze POs by derivatization have had a low ability to detect them. A neurophysiological detector (NPD)-high-performance liquid chromatography (HPLC) system was developed for specific detection with high detection ability. The first official presentation of our NPD was at the 3<sup>rd</sup> International Symposium on Separation in BioSciences SBS 2003: A 100 Years of Chromatography, May 13-18, 2003, in Moscow, Russia. The NPD in connection to HPLC was developed 14 years before the presentation at the SBS in 2003. Initially, NPD combined with an HPLC system was developed for intelligence services and only for use in monitoring and espionage against the unlawful production of neuroparalytic agents, as explained in this article. NPD combined with an HPLC system was developed in Umeå, Sweden, in 1987-89;the protocol was further developed in Statens Plantevern Institutt, Ås, Norway, in 1990-92. NPD may have great utility during the current period of active warfare in Europe. The initial challenge was detecting unlawful production and use of PO compounds and their metabolites that can potentially block acetylcholinesterase. The sensor in NPD can detect and monitor substances such as tabun, soman, and modern PO poisons used in military applications. This article describes the history of the development of NPD and its aim as a sensitive sensor in detecting PO substances with acetylcholinesterase-blocking effects. 展开更多
关键词 Neurophysiological detector Phosphor-Organic Substances TABUN SOMAN Criminal Use of Poisons in Warfare
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部