期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging 被引量:5
1
作者 Ben-Zu Hong Xin-Feng Li Jian-Qing Lin 《World Journal of Gastroenterology》 SCIE CAS 2015年第20期6374-6380,共7页
AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was ... AIM: To investigate the diagnostic ability of single-shot echo-planar imaging(EPI) diffusion-weighted imaging (DWI) to differentiate between malignant and benign pancreatic lesions. METHODS: A computerized search was performed on Pub Med, MEDLINE and EMBASE up to August 2014. Nine studies(10 sets of data) with a total of 304 malignant pancreatic lesions and 188 benign pancreatic lesions were included. The characteristics of each study included the study name, year of publication, magnetic resonance modalities used, patient population, strength of field, pulse time, repetition time, echo time(TE), maximum b factor, mean age, mean body weight, fat suppression, number of benign and malignant lesions, and true positive, true negative, false positive and false negative results. All analyses were performed using Meta-Di Sc and Stata 11.0.RESULTS: The pooled sensitivity and specificity of singleshot EPI DWI were 0.83(95%CI: 0.79-0.87) and 0.77(95%CI: 0.70-0.83), respectively. The positive likelihood ratio and negative likelihood ratio were 5.09(95%CI: 2.19-11.84) and 0.23(95%CI: 0.15-0.36), respectively. The P value for the χ2 heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.89 and 0.82, respectively. Publication bias was not present(t = 0.58, P = 0.58). Meta-regression analysis indicated that fat suppression, mean age, TE, and maximum b factor were not sources of heterogeneity(all P > 0.05). CONCLUSION: Single-shot EPI DWI is useful to differentiate between malignant and benign pancreatic lesions. Lesion size ≥ 2 cm is the limit for the diagnosis of early lesions. 展开更多
关键词 Meta-analysis single-shot echo-planarimaging DIFFUSION-WEIGHTED imaging PANCREATIC cancer Differential diagnosis
下载PDF
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating
2
作者 卫晨希 吴朝 +6 位作者 Faiz Wali 魏文彬 鲍园 骆荣辉 王磊 刘刚 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期501-507,共7页
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa... X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging single-shot decent resolution staggered grating computed tomography
下载PDF
Diffusion weighted imaging for the detection and evaluation of cholesteatoma 被引量:8
3
作者 Benjamin Henninger Christian Kremser 《World Journal of Radiology》 CAS 2017年第5期217-222,共6页
Cholesteatoma is a collection of keratinous debris and stratified squamous epithelium.It is trapped in the middle ear and can lead to bony erosion.The disease is treated surgically often followed by a second-look proc... Cholesteatoma is a collection of keratinous debris and stratified squamous epithelium.It is trapped in the middle ear and can lead to bony erosion.The disease is treated surgically often followed by a second-look procedure to check for residual tissue or recurrence.Cholesteatoma has specific signal-intensity characteristics on magnetic resonance imaging with very high signal intensity on diffusion weighted imaging(DWI).Various DWI techniques exist:Echo-planar imaging(EPI)-based and non-EPI-based techniques as well as new approaches like multi-shot EPI DWI.This article summarizes all techniques,discusses the significance in detecting cholesteatoma and mentions actual studies.Further recommendations for daily clinical practise are provided. 展开更多
关键词 CHOLESTEATOMA Diffusion weighted imaging Computed tomography Magnetic resonance imaging echo-planar imaging Non-echo-planar imaging
下载PDF
First commissioning results of the coherent scattering and imaging endstation at the Shanghai soft X-ray free-electron laser facility 被引量:2
4
作者 Jia-Dong Fan Ya-Jun Tong +17 位作者 Yong-Gan Nie Zi-Chen Gao Bo He Hui Luan Dong-Hao Lu Jian-Hua Zhang Di-Fei Zhang Xin-Ye Yuan Jia-Hua Chen Zhi Guo Tao Liu Meng Zhang Chao Feng Hai-Xiao Deng Bo Liu Zhen-Tang Zhao Zhi Liu Huai-Dong Jiang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期48-58,共11页
The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstation... The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstations covering a range of 100–620 eV for ultrafast X-ray science.Two undulator lines are designed and constructed,based on different lasing modes:self-amplified spontaneous emission and echo-enabled harmonic generation.The coherent scattering and imaging(CSI)endstation is the first of five endstations to be commissioned online.It focuses on high-resolution single-shot imaging and the study of ultrafast dynamic processes using coherent forward scattering techniques.Both the single-shot holograms and coherent diffraction patterns were recorded and reconstructed for nanoscale imaging,indicating the excellent coherence and high peak power of the SXFEL and the possibility of‘‘diffraction before destruction’’experiments at the CSI endstation.In this study,we report the first commissioning results of the CSI endstation. 展开更多
关键词 X-ray free electron laser Coherent diffraction imaging Fourier transform holography single-shot imaging Phase retrieval
下载PDF
Microlens Light Field Imaging Method Based on Bionic Vision and 3-3 Dimensional Information Transforming 被引量:4
5
作者 Shoujiang ZHAO Fan LIU +4 位作者 Peng YANG Hongying ZHAO Anand ASUNDI Lei YAN Haimeng ZHAO 《Journal of Geodesy and Geoinformation Science》 2019年第2期70-77,共8页
his paper adopts the 3-3-2 information processing method for the capture of moving objects as its premise, and proposes a basic principle of three-dimensional (3D) imaging using biological compound eye. Traditional bi... his paper adopts the 3-3-2 information processing method for the capture of moving objects as its premise, and proposes a basic principle of three-dimensional (3D) imaging using biological compound eye. Traditional bionic vision is limited by the available hardware. Therefore, in this paper, the new-generation technology of microlens-array light-field camera is proposed as a potential method for the extraction of depth information from a single image. A significant characteristic of light-field imaging is that it records intensity and directional information from the lights entering the camera. Herein, a refocusing method using light-field image is proposed. By calculating the focusing cost at different depths from the object, the imaging plane of the object is determined, and a depth map is constructed based on the position of the object’s imaging plane. Compared with traditional light-field depth estimation, the depth map calculated by this method can significantly improve resolution and does not depend on the number of light-field microlenses. In addition, considering that software algorithms rely on hardware structure, this study develops an imaging hardware that is only 7 cm long based on the second-generation microlens camera’s structure, further validating its important refocusing characteristics. It thereby provides a technical foundation for 3D imaging with a single camera. 展开更多
关键词 BIONIC compound eye single-shot light field 3D-3D transform imaging MICROLENSES STEREO PHOTOGRAMMETRY
下载PDF
Impact of Field Strength and Respiratory Motion Control on Diffusion-Weighted MR Imaging of the Liver
6
作者 Johanna Berg Sven Mansson +2 位作者 Jonas Svensson Olle Ekberg Markus F.Müller 《Open Journal of Medical Imaging》 2013年第1期31-39,共9页
Purpose: To evaluate the impact of field strength and respiratory motion control on diffusion-weighted MR imaging (DWI) of the liver at 1.5 and 3 T. Material and Methods: Three DWI sequences using seven b-values from ... Purpose: To evaluate the impact of field strength and respiratory motion control on diffusion-weighted MR imaging (DWI) of the liver at 1.5 and 3 T. Material and Methods: Three DWI sequences using seven b-values from 20 - 400 s/mm2 were designed with identical parameters but with different handling of respiratory motion [respiratory triggered (RT), free breathing (FB), breath hold (BH)] on 3 T and 1.5 T. Thirteen volunteers were examined at a 3 T and six of them also at a 1.5 T magnet. DW images were analyzed quantitatively and qualitatively. Regions of interest were placed in cranial, middle and caudal parts of the right liver lobe (RLL) and ADC and SNR were calculated. Results: ADC in RLL tended to be lower at 3 T MRI. Least inter-subject ADC variability was found with RT in the middle RLL at 3 T. Highest ADCs were found caudally in the RLL. Significant differences in ADC between middle and caudal RLL were calculated in FB and RT at 3 T and FB and BH at 1.5 T, respectively. No significant difference in SNR was found between 3 T and 1.5 T. There were significantly more artifacts in the left liver lobe (LLL) compared to the RLL in all sequences and in the LLL at 3 T compared to 1.5 T. Conclusion: Our study suggests that longitudinal hepatic ADC measurements should be performed using equivalent field strength, b-values, and acquisition technique, given influence of these factors on ADC measurements. 展开更多
关键词 Magnetic Resonance imaging DIFFUSION echo-planar imaging 3 T LIVER Respiratory Motion
下载PDF
Single-shot compressed ultrafast photography: a review 被引量:13
7
作者 Dalong Qi Shian Zhang +9 位作者 Chengshuai Yang Yilin He Fengyan Cao Jiali Yao Pengpeng Ding Liang Gao Tianqing Jia Jinyang Liang Zhenrong Sun Lihong V.Wange 《Advanced Photonics》 EI CSCD 2020年第1期41-56,共16页
Compressed ultrafast photography(CUP)is a burgeoning single-shot computational imaging technique that provides an imaging speed as high as 10 trillion frames per second and a sequence depth of up to a few hundred fram... Compressed ultrafast photography(CUP)is a burgeoning single-shot computational imaging technique that provides an imaging speed as high as 10 trillion frames per second and a sequence depth of up to a few hundred frames.This technique synergizes compressed sensing and the streak camera technique to capture nonrepeatable ultrafast transient events with a single shot.With recent unprecedented technical developments and extensions of this methodology,it has been widely used in ultrafast optical imaging and metrology,ultrafast electron diffraction and microscopy,and information security protection.We review the basic principles of CUP,its recent advances in data acquisition and image reconstruction,its fusions with other modalities,and its unique applications in multiple research fields. 展开更多
关键词 ultrafast optical imaging compressed sensing computational imaging single-shot measurement
原文传递
An internal-external optimized convolutional neural network for arbitrary orientated object detection from optical remote sensing images 被引量:1
8
作者 Sihang Zhang Zhenfeng Shao +2 位作者 Xiao Huang Linze Bai Jiaming Wang 《Geo-Spatial Information Science》 SCIE EI CSCD 2021年第4期654-665,共12页
Due to the bird’s eye view of remote sensing sensors,the orientational information of an object is a key factor that has to be considered in object detection.To obtain rotating bounding boxes,existing studies either ... Due to the bird’s eye view of remote sensing sensors,the orientational information of an object is a key factor that has to be considered in object detection.To obtain rotating bounding boxes,existing studies either rely on rotated anchoring schemes or adding complex rotating ROI transfer layers,leading to increased computational demand and reduced detection speeds.In this study,we propose a novel internal-external optimized convolutional neural network for arbitrary orientated object detection in optical remote sensing images.For the internal opti-mization,we designed an anchor-based single-shot head detector that adopts the concept of coarse-to-fine detection for two-stage object detection networks.The refined rotating anchors are generated from the coarse detection head module and fed into the refining detection head module with a link of an embedded deformable convolutional layer.For the external optimiza-tion,we propose an IOU balanced loss that addresses the regression challenges related to arbitrary orientated bounding boxes.Experimental results on the DOTA and HRSC2016 bench-mark datasets show that our proposed method outperforms selected methods. 展开更多
关键词 Arbitrary orientated object detection optical remote sensing image single-shot deep learning
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部