In this paper we study the extraordinary optical transmission of one-dimensional multi-slits in an ideal metal film.The transmissivity is calculated as a function of various structural parameters.The transmissivity os...In this paper we study the extraordinary optical transmission of one-dimensional multi-slits in an ideal metal film.The transmissivity is calculated as a function of various structural parameters.The transmissivity oscillates,with the period being just the light wavelength,as a function of the spacing between slits.As the number of slits increases,the transmissivity varies in one of three ways.It can increase,attenuate,or remain basically unchanged,depending on the spacing between slits.Each way is in an oscillatory manner.The slit interaction responsible for the oscillating transmission strength that depends on slit spacing is the subject of more detailed investigation.The interaction most intuitively manifests as a current distribution in the metal surface between slits.We find that this current is attenuated in an oscillating fashion from the slit corners to the center of the region between two adjacent slits,and we present a mathematical expression for its waveform.展开更多
Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of pre...Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].展开更多
A general model for creating an optical vortex using a variable-width Fermat spiral slit(FSS)mask was developed.The generated optical vortex demonstrates much better quality than those produced by slits with a uniform...A general model for creating an optical vortex using a variable-width Fermat spiral slit(FSS)mask was developed.The generated optical vortex demonstrates much better quality than those produced by slits with a uniform width.The depth of focus was nearly doubled,which can be explained by discretizing the gradual-width FSS.To demonstrate the generation robustness,the slits were printed on a transparent slide,and an output vortex beam with greater than 98%intensity purity was obtained.With the high quality and simplicity of this vortex generation method,its analysis and generation scheme are expected to be extended to generation of plasmonic vortices and short-wavelength light sources such as X-rays and electron beams.Generation of highquality optical vortex beams at an almost negligible cost will make investigation much more accessible.展开更多
An advanced conceptual design of a high-bit-rate triple product acousto-optical processor is presented that can be applied in a number of astrophysical problems. We briefly describe the Large Millimeter Telescope as o...An advanced conceptual design of a high-bit-rate triple product acousto-optical processor is presented that can be applied in a number of astrophysical problems. We briefly describe the Large Millimeter Telescope as one of the potential observational infrastructures where the acousto-optical spectrometer can be successfully used. A summary on the study of molecular gas in relatively old (age > 10 Myr) disks around main sequence stars is provided. We have identified this as one of the science cases in which the proposed processor can have a big impact. Then we put forward triple product acousto-optical processor is able to realize algorithm of the space-and-time integrating, which is desirable for a wideband spectrum analysis of radio-wave signals with an improved resolution providing the resolution power of about 105 - 106. It includes 1D-acousto-optic cells as the input devices for a 2D-optical data processing. The importance of this algorithm is based on exploiting the chirp Z-transform technique providing a 2D-Fourier transform of the input signals. The system produces the folded spectrum, accumulating advantages of both space and time integrating. Its frequency bandwidth is practically equal to the bandwidth of transducers inherent in acousto-optical cells. Then, similar processor is able to provide really high frequency resolution, which is practically equal to the reciprocal of the CCD-matrix photo-detector integration time. Here, the current state of developing the triple product acousto-optical processor in frames of the astrophysical instrumentation is shortly discussed.展开更多
A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. T...A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.展开更多
Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffract...Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffraction gratings as dispersive elements. There is a set of the static gratings with slit-densities 150 - 600 lines/mm and optical apertures 9 cm × 9 cm that provide the first order spectral resolution from 0.8 to 3.2 A/pixel, respectively. However, the needed mechanical manipulations, namely, replacing the static diffraction gratings with various resolutions and following recalibration of spectrometer within studying even the same object are practically inconvenient and lead to wasting rather expensive observation time. We suggest exploiting an acousto-optical cell, i.e. the dynamic diffraction grating tunable electronically, as dispersive element in that spectrometer. Involving the acousto-optical technique, which can potentially provide electronic control over the spectral resolution and the range of observations, leads to eliminating the abovementioned demerits and improving the efficiency of analysis.展开更多
We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a...We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a polymethyl methacrylate(PMMA) film with a CCD as the detector. The spectrum is obtained by solving a system of simultaneous linear equations. The Tikhonov regularization method is used to achieve a resolution at the picometer level. Compared with conventional spectrometers, the proposed device is low-cost and easy to fabricate due to its simple structure. Furthermore, its compact feature renders the device ideal for miniaturization and integration as the systems in microfluidics architectures and lab-on-chip designs.展开更多
A simple method is applied to calculating the optical path difference (OPD) of a plane parallel uniaxial plate with an arbitrary optical axis direction. Then, the theoretical expressions of the OPD and lateral displ...A simple method is applied to calculating the optical path difference (OPD) of a plane parallel uniaxial plate with an arbitrary optical axis direction. Then, the theoretical expressions of the OPD and lateral displacement (LD) of Savart polariscope under non-ideal conditions are obtained exactly. The variations of OPD and LD are simulated, and some important conclusions are obtained when the optical axis directions have an identical tolerance of /pm 1^{{/circ}}. An application example is given that the tolerances of optical axis directions are gained according to the spectral resolution tolerances of the stationary polarization interference imaging spectrometer (SPIIS). Several approximate formulae are obtained for explaining some conclusions above. The work provides a theoretical guidance for the optic design, crystal processing, installation and debugging, data analysis and spectral reconstruction of the SPIIS.展开更多
A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array...A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array.The resulting spectrometer measures 3 mm×4 mm×14 mm and shows a significant improvement in resolution over a spectrometer without the collimator when used with diffuse light.Its small size and high throughput make it ideal for applications such as wearable optical sensing,where light from highly scattering tissue is measured.Plethysmographic measurements on the wrist were demonstrated,showing rapid data collection with diffuse light.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11074145,10874124,and 61275028)
文摘In this paper we study the extraordinary optical transmission of one-dimensional multi-slits in an ideal metal film.The transmissivity is calculated as a function of various structural parameters.The transmissivity oscillates,with the period being just the light wavelength,as a function of the spacing between slits.As the number of slits increases,the transmissivity varies in one of three ways.It can increase,attenuate,or remain basically unchanged,depending on the spacing between slits.Each way is in an oscillatory manner.The slit interaction responsible for the oscillating transmission strength that depends on slit spacing is the subject of more detailed investigation.The interaction most intuitively manifests as a current distribution in the metal surface between slits.We find that this current is attenuated in an oscillating fashion from the slit corners to the center of the region between two adjacent slits,and we present a mathematical expression for its waveform.
基金supported by the National Natural Science Foundation China(No.42022051,No.U21A2028)Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.Y202089)the HFIPS Director's Fund(No.YZJJ202101,No.BJPY2023A02).
文摘Optical frequency combbased Fourier transform spectroscopy has the features of broad spectral bandwidth,high sensitivity,andmultiplexed trace gas detection,which has valuable application potential in the fields of precision spectroscopy and trace gas detection.Here,we report the development of a mid-infrared Fourier transform spectrometer based on an optical frequency comb combined with a Herriott-type multipass cell.Using this instrument,the broadband absorption spectra of several important molecules,including methane,acetylene,water molecules and nitrous oxide,are measured by near real-time data acquisition in the 2800-3500 cm^(-1)spectral region.The achieved minimum detectable absorption of the instrument is 4.4×10^(-8)cm^(-1)·Hz^(-1/2)per spectral element.Broadband spectra of H_(2)0 are fited using the Voigt profile multispectral fitting technique and the consistency of the concentration inversion is 1%.Our system also enables precise spectroscopic measurements,and it allows the determination of the spectral line positions and upper state constants of N_(2)O in the(0002)-(1000)band,with results in good agreement with those reported by Toth[Appl.Opt.30,5289(1991)].
基金supported by the National Key Research and Development Program of China(Grant Nos.2022YFA1404800,and 2019YFA0705000)the National Natural Science Foundation of China(Grant Nos.12204340,12174280,12192254,11974218,92250304,and 92050202)+4 种基金the China Postdoctoral Science Foundation(Grant No.2022M722325)the Priority Academic Program Development of Jiangsu Higher Education Institutions,Tang ScholarLocal Science and Technology Development Project of the Central Government(Grant No.YDZX20203700001766)the Key Lab of Modern Optical Technologies of Jiangsu Province(Grant No.KJS2138)the Postgraduate Research&Practice Innovation Program of Jiangsu Province(Grant No.KYCX22_3183)。
文摘A general model for creating an optical vortex using a variable-width Fermat spiral slit(FSS)mask was developed.The generated optical vortex demonstrates much better quality than those produced by slits with a uniform width.The depth of focus was nearly doubled,which can be explained by discretizing the gradual-width FSS.To demonstrate the generation robustness,the slits were printed on a transparent slide,and an output vortex beam with greater than 98%intensity purity was obtained.With the high quality and simplicity of this vortex generation method,its analysis and generation scheme are expected to be extended to generation of plasmonic vortices and short-wavelength light sources such as X-rays and electron beams.Generation of highquality optical vortex beams at an almost negligible cost will make investigation much more accessible.
文摘An advanced conceptual design of a high-bit-rate triple product acousto-optical processor is presented that can be applied in a number of astrophysical problems. We briefly describe the Large Millimeter Telescope as one of the potential observational infrastructures where the acousto-optical spectrometer can be successfully used. A summary on the study of molecular gas in relatively old (age > 10 Myr) disks around main sequence stars is provided. We have identified this as one of the science cases in which the proposed processor can have a big impact. Then we put forward triple product acousto-optical processor is able to realize algorithm of the space-and-time integrating, which is desirable for a wideband spectrum analysis of radio-wave signals with an improved resolution providing the resolution power of about 105 - 106. It includes 1D-acousto-optic cells as the input devices for a 2D-optical data processing. The importance of this algorithm is based on exploiting the chirp Z-transform technique providing a 2D-Fourier transform of the input signals. The system produces the folded spectrum, accumulating advantages of both space and time integrating. Its frequency bandwidth is practically equal to the bandwidth of transducers inherent in acousto-optical cells. Then, similar processor is able to provide really high frequency resolution, which is practically equal to the reciprocal of the CCD-matrix photo-detector integration time. Here, the current state of developing the triple product acousto-optical processor in frames of the astrophysical instrumentation is shortly discussed.
基金supported by the National Natural Science Foundation of China(No.61205167)the China Postdoctoral Science Foundation Funded Project(No.2015M571033)
文摘A new miniature spectrometer with two entrance slits is proposed to expand the spectral band. The proposed spectrometer is designed such that the two entrance slits share the same concave grating and detector array. The two slits are located at different positions such that the spectral range of the same light source incident on the detector array varies greatly between the two slits. Only one of the two slits is illuminated at a given time; as such, the two spectral ranges are sequentially measured. Theoretical calculation and experimentation are conducted to verify the proposed design.
文摘Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffraction gratings as dispersive elements. There is a set of the static gratings with slit-densities 150 - 600 lines/mm and optical apertures 9 cm × 9 cm that provide the first order spectral resolution from 0.8 to 3.2 A/pixel, respectively. However, the needed mechanical manipulations, namely, replacing the static diffraction gratings with various resolutions and following recalibration of spectrometer within studying even the same object are practically inconvenient and lead to wasting rather expensive observation time. We suggest exploiting an acousto-optical cell, i.e. the dynamic diffraction grating tunable electronically, as dispersive element in that spectrometer. Involving the acousto-optical technique, which can potentially provide electronic control over the spectral resolution and the range of observations, leads to eliminating the abovementioned demerits and improving the efficiency of analysis.
基金supported by the Hong Kong Research Grants Council under CERG project 411907 and 412208Nation-al Basic Research Program of China(973)(No.2009CB930600)
文摘We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a polymethyl methacrylate(PMMA) film with a CCD as the detector. The spectrum is obtained by solving a system of simultaneous linear equations. The Tikhonov regularization method is used to achieve a resolution at the picometer level. Compared with conventional spectrometers, the proposed device is low-cost and easy to fabricate due to its simple structure. Furthermore, its compact feature renders the device ideal for miniaturization and integration as the systems in microfluidics architectures and lab-on-chip designs.
基金supported by the State Key Program of National Natural Science Foundation of China (Grant No. 40537031)the National Natural Science Foundation of China (Grant No. 40875013)+1 种基金the National Defense Basic Scientific Research Project, China (Grant No. A1420080187)the National High Technology Research and Development Program of China (Grant No. 2006AA12Z152)
文摘A simple method is applied to calculating the optical path difference (OPD) of a plane parallel uniaxial plate with an arbitrary optical axis direction. Then, the theoretical expressions of the OPD and lateral displacement (LD) of Savart polariscope under non-ideal conditions are obtained exactly. The variations of OPD and LD are simulated, and some important conclusions are obtained when the optical axis directions have an identical tolerance of /pm 1^{{/circ}}. An application example is given that the tolerances of optical axis directions are gained according to the spectral resolution tolerances of the stationary polarization interference imaging spectrometer (SPIIS). Several approximate formulae are obtained for explaining some conclusions above. The work provides a theoretical guidance for the optic design, crystal processing, installation and debugging, data analysis and spectral reconstruction of the SPIIS.
文摘A miniaturized short-wavelength infrared spectrometer for use with diffuse light was created by combining a thin form factor carbon nanotube composite collimator,a linear variable filter,and an InGaAs photodiode array.The resulting spectrometer measures 3 mm×4 mm×14 mm and shows a significant improvement in resolution over a spectrometer without the collimator when used with diffuse light.Its small size and high throughput make it ideal for applications such as wearable optical sensing,where light from highly scattering tissue is measured.Plethysmographic measurements on the wrist were demonstrated,showing rapid data collection with diffuse light.