Small-sized axial fans are used as air cooler for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotation...Small-sized axial fans are used as air cooler for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotational speed design is conducted,although,it causes the deterioration of efficiency and the increase of noise.Then,the adoption of contra-rotating rotors for the small-sized axial fan is proposed for the improvement of performance.In the case of contra-rotating rotors,it is necessary to design the rotor considering the unsteady flow condition of each front and rear rotor.In the present paper,the fan performance of the contra-rotating small-sized axial fan with 100mm diameter at a designed and a partial flow rates is shown,and the unsteady flow conditions at the inlet and the outlet of each front and rear rotor are clarified with unsteady numerical results.Furthermore,the relation between the performance and the unsteady flow condition of the contra-rotating small-sized axial fan is discussed and the methods to improve the performance are considered.展开更多
High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rot...High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rotating rotors have been adopted for some of high pressure and large flow rate cooling fans to meet the demand. The performance curve of the contra-rotating small-sized cooling fan with 40 mm square casing was investigated by an experimental apparatus and its internal flow condition was clarified by the numerical analysis. The fan static pressure of the front rotor was extremely low and it increased significantly at the rear rotor. The uniform flow was achieved at the inlet of the rear rotor because of the special shape of the casing between the front and rear rotors. On the other hand, the tip leakage flow was large enough to influence on the main flow of the test cooling fan by the design specification of high pressure with compact rotor diameter.展开更多
基金supported by Japan Science and Technology Agency and University of Tokushima and Komiya research aid
文摘Small-sized axial fans are used as air cooler for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotational speed design is conducted,although,it causes the deterioration of efficiency and the increase of noise.Then,the adoption of contra-rotating rotors for the small-sized axial fan is proposed for the improvement of performance.In the case of contra-rotating rotors,it is necessary to design the rotor considering the unsteady flow condition of each front and rear rotor.In the present paper,the fan performance of the contra-rotating small-sized axial fan with 100mm diameter at a designed and a partial flow rates is shown,and the unsteady flow conditions at the inlet and the outlet of each front and rear rotor are clarified with unsteady numerical results.Furthermore,the relation between the performance and the unsteady flow condition of the contra-rotating small-sized axial fan is discussed and the methods to improve the performance are considered.
文摘High pressure and large flow rate small-sized cooling fans are used for servers in data centers and there is a strong demand to increase its performance because of increase of quantity of heat from servers. Contra-rotating rotors have been adopted for some of high pressure and large flow rate cooling fans to meet the demand. The performance curve of the contra-rotating small-sized cooling fan with 40 mm square casing was investigated by an experimental apparatus and its internal flow condition was clarified by the numerical analysis. The fan static pressure of the front rotor was extremely low and it increased significantly at the rear rotor. The uniform flow was achieved at the inlet of the rear rotor because of the special shape of the casing between the front and rear rotors. On the other hand, the tip leakage flow was large enough to influence on the main flow of the test cooling fan by the design specification of high pressure with compact rotor diameter.