The concepts of microgrids(MGs)and smart grid represent the recent targeted revolution towards fully smart electrical network integrated with high penetration of renewable energy sources(RESs).The protection system of...The concepts of microgrids(MGs)and smart grid represent the recent targeted revolution towards fully smart electrical network integrated with high penetration of renewable energy sources(RESs).The protection system of MGs becomes a challenge due to variable characteristics of its currents,bidirectional power flow and output power fluctuations of RES,causing selectivity and sensitivity issues for conventional protective devices(PDs)with fixed setting.In this paper,a smart protection scheme(SPS)is proposed using micro-phasor measurement units(μPMUs)to obtain the continuous rapid synchronized phasor measurement data.And it is communicated with a microgrid central controller(MGCC)through highly reliable communication architecture to carry out online smart adaptive protection scheme.Fault index coefficients and abnormality coefficients are calculated for each feeder to detect the fault location and the abnormality case.Detailed modeling of an MG including 10-bus connected distribution system with integrated distributed generation(DG)is simulated using ETAP software.The proposed protection algorithm is modeled and evaluated using MATLAB software.The proposed fault detector and abnormality detector can enable quick and accurate fault identification and isolation.展开更多
通过研究基于光纤通信方式下的10 k V智能配电网线路全线速动保护方案和实现方法,结合具体的配电网系统要求设计出新型原理的配电网继电保护,可同时满足选择性和速动性的要求。与传统配电网保护相比新方案具有原理简单、配置灵活、恢复...通过研究基于光纤通信方式下的10 k V智能配电网线路全线速动保护方案和实现方法,结合具体的配电网系统要求设计出新型原理的配电网继电保护,可同时满足选择性和速动性的要求。与传统配电网保护相比新方案具有原理简单、配置灵活、恢复供电快、安全可靠的特点,适合大规模推广。展开更多
文摘The concepts of microgrids(MGs)and smart grid represent the recent targeted revolution towards fully smart electrical network integrated with high penetration of renewable energy sources(RESs).The protection system of MGs becomes a challenge due to variable characteristics of its currents,bidirectional power flow and output power fluctuations of RES,causing selectivity and sensitivity issues for conventional protective devices(PDs)with fixed setting.In this paper,a smart protection scheme(SPS)is proposed using micro-phasor measurement units(μPMUs)to obtain the continuous rapid synchronized phasor measurement data.And it is communicated with a microgrid central controller(MGCC)through highly reliable communication architecture to carry out online smart adaptive protection scheme.Fault index coefficients and abnormality coefficients are calculated for each feeder to detect the fault location and the abnormality case.Detailed modeling of an MG including 10-bus connected distribution system with integrated distributed generation(DG)is simulated using ETAP software.The proposed protection algorithm is modeled and evaluated using MATLAB software.The proposed fault detector and abnormality detector can enable quick and accurate fault identification and isolation.