The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force...The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force is determined.Electrothermal coupling simulation using COMSOL is conducted,optimizing the outer diameter and length structure parameters of the coil.It is established that the heat dissipation of the coil is influenced by its outer diameter.Subsequently,based on optimized coil structure parameters,an orthogonal experimental design method combined with Ansys Maxwell is employed for simulation solution analysis to study the impact of structural parameters such as length,position,front and rear angles of the magnetic barrier ring in the iron core,armature length,and through-hole size on electromagnetic force.Optimal structural parameters are identified.Results indicate a decrease in steady-state electromagnet temperature by 3-4℃,an increase in the initial electromagnetic force by 32.63%,and a rise in the maximum electromagnetic force by 27.10%.展开更多
A new structure of the on- chip integrated inductors im plem ented in conventional Si process is presented as a lateral solenoid.The fabrication process utilizes a conventional Si technology with standard double- lay...A new structure of the on- chip integrated inductors im plem ented in conventional Si process is presented as a lateral solenoid.The fabrication process utilizes a conventional Si technology with standard double- layer m etal- lization.S param eters of the inductors based equivalent circuit are investigated and the inductor parameters are cal- culated from the m easured data.Experimental results are presented on an integrated inductors fabricated in a lateral solenoid type utilizing double m etal layers rather than a single metal layer as used in conventional planar spiral de- vices.Inductors with peak Q of 1.3and inductance value of 2 .2 n H are presented,which are com parable to conven- tional planar spiral inductors.展开更多
To select or develop an appropriate actuator is one of the key and difficult issues in the study of semi-active controlled landing gear. Performance of the actuator may directly affect the effectiveness of semi-active...To select or develop an appropriate actuator is one of the key and difficult issues in the study of semi-active controlled landing gear. Performance of the actuator may directly affect the effectiveness of semi-active control. In this article, parallel high-speed solenoid valves are chosen to be the actuators for the semi-active controlled landing gear and being studied. A nonlinear high-speed solenoid valve model is developed with the consideration of magnetic saturation characteristics and verified by test. According to the design rule of keeping the peak load as small as possible while absorbing the specified shock energy, a fuzzy PD control rule is designed. By the rule controller parameters can be self-regulated. The simulation results indicate that the semi-active control based on high-speed solenoid valve can effectively improve the control performance and reduce impact load during landing.展开更多
Diurnal variations of two mountain-plain solenoid (MPS) circulations associated with "first-step" terrain [Tibetan Plateau (TP)] and "second-step" terrain (high mountains between the TP and "east plains") ...Diurnal variations of two mountain-plain solenoid (MPS) circulations associated with "first-step" terrain [Tibetan Plateau (TP)] and "second-step" terrain (high mountains between the TP and "east plains") in China and their influence on the south west vortex (SWV) and the mei-yu front vortex (MYFV) were investigated via a semi-idealized mesoscale numerical model [Weather Research and Forecasting (WRF)] simulation integrated with ten-day average fields (mei-yu period of 1-10 July 2007). The simulations successfully reproduced two MPS circulations related to first and second-step terrain, diurnal vari- ations from the eastern edge of the TP to the Yangtze River-Huaihe River valleys (YHRV), and two precipitation maximum centers related to the SWV, MYFV. Analyses of the averaged final seven-day simulation showed the different diurnal peaks of precipitation at different regions: from the aftemoon to early evening at the eastern edge of the TP; in the early evening to the next early morning in the Sichuan Basin (SCB); and in the late evening to the next early morning over the mei-yu front (MYF). Analyses of individual two-day cases confirmed that the upward branches of the nightlime MPS circulations enhanced the precipitation over the SWV and the MYFV and revealed that the eastward extension of the SWV and its con vection were conducive to triggering the MYFVs. The eastward propagation of a rainfall streak from the eastern edge of the TP to the eastern coastal region was primarily due to a series of convective activities of several systems from west to east, including the MPS between the TP and SCB, the SWV, the MPS between second-step terrain and tile east plains, and the MYFV.展开更多
The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts....The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve.展开更多
Previous studies have confirmed that an active suspension system with high speed ON/OFF solenoid valves could provide the same vibration isolation efficiency as that of system with pressure proportional valve. In this...Previous studies have confirmed that an active suspension system with high speed ON/OFF solenoid valves could provide the same vibration isolation efficiency as that of system with pressure proportional valve. In this study, by using Linear-quadratic optimization technique and Kalman filter method, an optimal regulator controller with a state observer was designed for the proposed system. Simulation and experimental research was conducted on a quarter car model. The simulation analysis of the system frequency characteristic suggested that the peak value of magnitude response curve in the case of system with an optimal controller would be lowered significantly, and the experiment results also showed that an improvement in the vibration isolation effect was obtained in using the designed optimal controller over the sky hook damper controller.展开更多
A multi-domain nonlinear dynamic model of a proportional solenoid valve was presented.The electro-magnetic,mechanical and fluid subsystems of the valve were investigated,including their interactions.Governing equation...A multi-domain nonlinear dynamic model of a proportional solenoid valve was presented.The electro-magnetic,mechanical and fluid subsystems of the valve were investigated,including their interactions.Governing equations of the valve were derived in the form of nonlinear state equations.By comparing the simulated and measured data,the simulation model is validated with a deviation less than 15%,which can be used for the structural design and control algorithm optimization of proportional solenoid valves.展开更多
A hydraulic position system was designed employing two high speed On/Off solenoid valves with PWM(Pulse width modulation) technique and using LQ(Linear Quadratic) optimization principle. Based on the system, the parts...A hydraulic position system was designed employing two high speed On/Off solenoid valves with PWM(Pulse width modulation) technique and using LQ(Linear Quadratic) optimization principle. Based on the system, the parts of system can be formulated with equations. According to equations, the mathematical model of the system was established. By simulation, the corresponding LQ optimal controller was designed and the PWM signals were generated. The comparison of the simulation and experiment results show that LQ optimal control method with PWM technique employing high speed On/Off solenoid valve can provide better system performance and a high position precision is obtained.展开更多
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate a...High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.展开更多
Influence of eddy current on transient characteristics of common rail injector solenoid valve was studied in this paper. Experimental investigations of drive current and power source volt- age of both drive current as...Influence of eddy current on transient characteristics of common rail injector solenoid valve was studied in this paper. Experimental investigations of drive current and power source volt- age of both drive current ascending and descending process were conducted on a common rail injec- tor solenoid valve. A new discretizing calculation method of solenoid valve flux linkage was put for- ward for the first time based on the experimental results and drive circuit principle, and flux linkage of both drive current ascending and descending process were evaluated. New inductance calculation methods for drive current ascending and descending process respectively were also presented. Influ- ence of parasitic inductance was evaluated. Results indicate that the air gap, under which the transi- ent flux linkage of the solenoid valve is the biggest, varies with drive current due to eddy current. Flux linkage of drive current descending process is bigger than that of drive current ascending process under the same drive current and the same air gap width. Eddy current can reduce the delay between the time that drive current begins to descend and the time that armature begins to move downward. Inductance of drive current descending process is bigger than that of drive current as- cending process over larger scope of drive current, but the difference becomes smaller with the in- creasing of air gap width. The differences of both flux linkage and inductance between drive current ascending and descending process are caused by the eddy current in core and armature materials.展开更多
The following article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published papers. The scientific com...The following article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published papers. The scientific community takes a very strong view on this matter, and the Health treats all unethical behavior such as plagiarism seriously.This paper published in Vol.4 No. 3,316-322(pages), 2013, has been removed from this site.展开更多
Currently, most researches use signals, such as the coil current or voltage of solenoid, to identify parameters; typically, parameter identification method based on variation rate of coil current is applied for positi...Currently, most researches use signals, such as the coil current or voltage of solenoid, to identify parameters; typically, parameter identification method based on variation rate of coil current is applied for position estimation. The problem exists in these researches that the detected signals are prone to interference and difficult to obtain. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which adds a new group of secondary winding to the coil of the ordinary switching electromagnet. On the basis of electromagnetic coupling theory analysis and simulation research of the magnetic field regarding the primary and secondary winding coils, and in accordance with the fact that under PWM control mode varying core position and operating current of windings produce different characteristic of flux increment of the secondary winding. The flux increment of the electromagnet winding can be obtained by conducting time domain integration for the induced voltage signal of the extracted secondary winding, and the core position from the two-dimensional fitting curve of the operating winding current and flux-linkage characteristic quantity of solenoid are calculated. The detecting and testing system of solenoid core position is developed based on the theoretical research. The testing results show that the flux characteristic quantity of switching electromagnet magnetic circuit is able to effectively show the core position and thus to accomplish the non-displacement transducer detection of the said core position of the switching electromagnet. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which provides a new theory and method for switch solenoid to control the proportional valve.展开更多
An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expre...An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expressions is firstly developed to calculate the self-inductance of a single layer, and then numerical calcu lation of the mutual inductance between two layers is introduced. Using the presented computation method, the inductance of a solenoid designed in the experiment is successfully calculated (4.30 mH), which has a difference of less than 1% from the experimental data.展开更多
Objective A novel high-speed three-way solenoid valve is developed, which is used for the common-rail injection system equipped on DME powered engine. In order to improve the dynamic response performance of the three-...Objective A novel high-speed three-way solenoid valve is developed, which is used for the common-rail injection system equipped on DME powered engine. In order to improve the dynamic response performance of the three-way solenoid. Methods Experimental studies have been conducted to investigate the effects of spool stroke, drive voltage, negative demagnetizing pulse and two drive schemes on the dynamic response performance of the three-way solenoid valve. Results The results show that the dynamic response performance of the three-way solenoid valve can be remarkably improved by shortening the spool stroke and increasing the drive voltage. Simultaneously, the difference between the response time of closing valve and that of opening valve decreases. At each different drive voltage, there exists an optimal negative demagnetizing pulse corresponding to the same positive exciting pulse. At this optimal pulse, the dynamic response performance of the three-way solenoid valve is the best. In addition, the high drive voltage can lead to the smaller optimal negative demagnetizing pulse. It is also indicated from the experiments that the dynamic response performance of the three-way solenoid valve is better when the NO.1 drive scheme is adopted. The lower drive voltage results in the larger difference between the dynamic response performances for the two drive schemes. Conclusion The dynamic response performance of a novel three-way solenoid valve is good.展开更多
A central solenoid model coil will be set up to develop and verify the technique for the full-size central solenoid coil of the China Fusion Engineering Test Reactor.In case of quench and failures of superconducting c...A central solenoid model coil will be set up to develop and verify the technique for the full-size central solenoid coil of the China Fusion Engineering Test Reactor.In case of quench and failures of superconducting coils,the quench protection(QP)system,which employs fuse-based commutation technology,is designed.This paper presents an analytical model to investigate the commutation process in the QP circuit.The model consists of the QP circuit equations,the breaker arc model,the fuse pre-arc model,and the fuse arc model.The model is employed in the whole commutation process including current transfer from breaker branch to the fuse branch model,then from fuse branch to the discharge resistor branch,and current decrease to zero in the discharge resistor.The experiment result verified the effectiveness of the presented model.The model might be helpful for design of the fuse and optimization of the commutation circuit.展开更多
We analyze the familiar effect of the pulling of a magnetizable rod by a magnetic field inside a solenoid. We find that the analogy with the pulling of a dielectric slab by a charged capacitor is not as direct as usua...We analyze the familiar effect of the pulling of a magnetizable rod by a magnetic field inside a solenoid. We find that the analogy with the pulling of a dielectric slab by a charged capacitor is not as direct as usually thought. Indeed, there are two possibilities to pursue the analogy, according to the correspondence used,?either E → B and D → H, or E?→ H and D?→ B. One of these results in an incorrect sign in the force, while the other gives the correct result. We avoid this ambiguity in the usual energy method applying a momentum balance equation derived from Maxwell’s equations. This method permits the calculation of the force with a volume integration of a force density, or with a surface integration of a stress tensor. An interpretation of our results establishes that the force acts at the interface and has its origin in Maxwell′s magnetic stresses at the medium-vacuum interface. This approach provides new insights and a new perspective of the origin of this force.展开更多
The central solenoid (CS) composed of cable-in-conduit (CIC) type conductor is animportant part of the HT-7U device. The CS coils can be considered from the viewpoint of micro-mechanics as a composite material. And th...The central solenoid (CS) composed of cable-in-conduit (CIC) type conductor is animportant part of the HT-7U device. The CS coils can be considered from the viewpoint of micro-mechanics as a composite material. And then, the residual stiffness is computed according to themicro-damage modeling of continuum damage mechanics. These material properties have beenused as input data for finite element method (FEM) analysis. In this paper the computationalanaysis of the stress and the displacement on the central solenoid are made by the finite elementanalysis system COSMOS/M2.0 under Operating temperature. According to the analytical results,the CS coils are all satisfied with designed safety criteria.展开更多
The central solenoid is an important part of the HT-7U device. In this paper, the computational analysis of the stress and the displacement on the pre-load structures of the central solenoid have been made by the fin...The central solenoid is an important part of the HT-7U device. In this paper, the computational analysis of the stress and the displacement on the pre-load structures of the central solenoid have been made by the finite element analysis system COSMOS/M2.0 under room and/or operating temperature. According to the analytical results, the clip aprons and compression plates are all satisfied with safety design criteria.展开更多
The results of the preliminary development of the HTS conductor based on the VS-type design and parallel stacks for the central solenoid of the compact thermonuclear reactor TRT are presented. One of the main problems...The results of the preliminary development of the HTS conductor based on the VS-type design and parallel stacks for the central solenoid of the compact thermonuclear reactor TRT are presented. One of the main problems that need to be solved for the successful implementation of such projects is the creation of high-current high-temperature superconducting (HTS) conductors for Toroidal Field coils (TF) and Central Solenoid (CS) sections. The conductor must have a high engineering current density of at least 90 A/mm<sup>2</sup>. The induction of the magnetic field in the central solenoid reaches 14 T, which leads to the occurrence of large mechanical stresses due to the influence of Lorentz forces. Like many large magnets, CS has a lot of stored energy. For the safe withdrawal of stored energy from the magnet, it requires the inclusion of elements in the conductor that provide an acceptable level of electrical voltage and heating of the conductor insulation. Thus, a sufficient amount of stabilizing and reinforcing materials should be placed in the conductor. In addition, the “cable-in-conduit” type of conductor must have channels for pumping the refrigerant. Two fundamentally different versions of the conductor based on radially arranged REBCO tapes and on the basis of pre-assembled tape packages are considered. Based on the analysis of the magnetic field distribution in the conductor by finite element method, the design characteristics of the proposed conductors under various operating modes of the electromagnetic system (EMS) of the tokamak TRT was evaluated. The results of the evaluation of the current carrying capacity of the conductor and the estimation of energy losses in a changing magnetic field in comparison with known methods are also presented.展开更多
A widespread assertion has existed for a long time, believing the external field of an infinitely long solenoid should be zero, but it is proofed to be wrong in this work. The components of magnetic flux density of cu...A widespread assertion has existed for a long time, believing the external field of an infinitely long solenoid should be zero, but it is proofed to be wrong in this work. The components of magnetic flux density of current-carrying, closely wound cylindrical solenoids are calculated. At a distant field point, the external field definitely has a nonzero component, being equal to that of a straight wire of equal length. Since this equivalence is length-independent, it still holds true for ideal solenoids having infinite length. Hence the incorrect and still spreading inference about long solenoids should be rectified. Furthermore, theoretical and experimental discussions involving solenoids should be reviewed again carefully.展开更多
文摘The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force is determined.Electrothermal coupling simulation using COMSOL is conducted,optimizing the outer diameter and length structure parameters of the coil.It is established that the heat dissipation of the coil is influenced by its outer diameter.Subsequently,based on optimized coil structure parameters,an orthogonal experimental design method combined with Ansys Maxwell is employed for simulation solution analysis to study the impact of structural parameters such as length,position,front and rear angles of the magnetic barrier ring in the iron core,armature length,and through-hole size on electromagnetic force.Optimal structural parameters are identified.Results indicate a decrease in steady-state electromagnet temperature by 3-4℃,an increase in the initial electromagnetic force by 32.63%,and a rise in the maximum electromagnetic force by 27.10%.
文摘A new structure of the on- chip integrated inductors im plem ented in conventional Si process is presented as a lateral solenoid.The fabrication process utilizes a conventional Si technology with standard double- layer m etal- lization.S param eters of the inductors based equivalent circuit are investigated and the inductor parameters are cal- culated from the m easured data.Experimental results are presented on an integrated inductors fabricated in a lateral solenoid type utilizing double m etal layers rather than a single metal layer as used in conventional planar spiral de- vices.Inductors with peak Q of 1.3and inductance value of 2 .2 n H are presented,which are com parable to conven- tional planar spiral inductors.
基金Aeronautical Science Foundation of China (04B52012, 98B52023)
文摘To select or develop an appropriate actuator is one of the key and difficult issues in the study of semi-active controlled landing gear. Performance of the actuator may directly affect the effectiveness of semi-active control. In this article, parallel high-speed solenoid valves are chosen to be the actuators for the semi-active controlled landing gear and being studied. A nonlinear high-speed solenoid valve model is developed with the consideration of magnetic saturation characteristics and verified by test. According to the design rule of keeping the peak load as small as possible while absorbing the specified shock energy, a fuzzy PD control rule is designed. By the rule controller parameters can be self-regulated. The simulation results indicate that the semi-active control based on high-speed solenoid valve can effectively improve the control performance and reduce impact load during landing.
基金jointly sponsored by a project of the State Key Laboratory of Severe Weather,Chinese Academy of Meteorological Sciences(Grant No.2011LASWA15)the National Key Basic Research and Development Project of China(Grant No.2012CB417201)the National Natural Science Foundation of China(Grant No.40930951)
文摘Diurnal variations of two mountain-plain solenoid (MPS) circulations associated with "first-step" terrain [Tibetan Plateau (TP)] and "second-step" terrain (high mountains between the TP and "east plains") in China and their influence on the south west vortex (SWV) and the mei-yu front vortex (MYFV) were investigated via a semi-idealized mesoscale numerical model [Weather Research and Forecasting (WRF)] simulation integrated with ten-day average fields (mei-yu period of 1-10 July 2007). The simulations successfully reproduced two MPS circulations related to first and second-step terrain, diurnal vari- ations from the eastern edge of the TP to the Yangtze River-Huaihe River valleys (YHRV), and two precipitation maximum centers related to the SWV, MYFV. Analyses of the averaged final seven-day simulation showed the different diurnal peaks of precipitation at different regions: from the aftemoon to early evening at the eastern edge of the TP; in the early evening to the next early morning in the Sichuan Basin (SCB); and in the late evening to the next early morning over the mei-yu front (MYF). Analyses of individual two-day cases confirmed that the upward branches of the nightlime MPS circulations enhanced the precipitation over the SWV and the MYFV and revealed that the eastward extension of the SWV and its con vection were conducive to triggering the MYFVs. The eastward propagation of a rainfall streak from the eastern edge of the TP to the eastern coastal region was primarily due to a series of convective activities of several systems from west to east, including the MPS between the TP and SCB, the SWV, the MPS between second-step terrain and tile east plains, and the MYFV.
基金Supported by Science Fund for Creative Research Groups of National Natural Science Foundation of China(Grant No.51221004)National Natural Science Foundation of China(Grant No.50805127)Fundamental Research Funds for the Central Universities of China(Grant No.2011QNA4002)
文摘The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve.
文摘Previous studies have confirmed that an active suspension system with high speed ON/OFF solenoid valves could provide the same vibration isolation efficiency as that of system with pressure proportional valve. In this study, by using Linear-quadratic optimization technique and Kalman filter method, an optimal regulator controller with a state observer was designed for the proposed system. Simulation and experimental research was conducted on a quarter car model. The simulation analysis of the system frequency characteristic suggested that the peak value of magnitude response curve in the case of system with an optimal controller would be lowered significantly, and the experiment results also showed that an improvement in the vibration isolation effect was obtained in using the designed optimal controller over the sky hook damper controller.
基金Project(2008ZHZX1A0502) supported by the Independence Innovation Achievements Transformation Crucial Special Program of Shandong Province,China
文摘A multi-domain nonlinear dynamic model of a proportional solenoid valve was presented.The electro-magnetic,mechanical and fluid subsystems of the valve were investigated,including their interactions.Governing equations of the valve were derived in the form of nonlinear state equations.By comparing the simulated and measured data,the simulation model is validated with a deviation less than 15%,which can be used for the structural design and control algorithm optimization of proportional solenoid valves.
文摘A hydraulic position system was designed employing two high speed On/Off solenoid valves with PWM(Pulse width modulation) technique and using LQ(Linear Quadratic) optimization principle. Based on the system, the parts of system can be formulated with equations. According to equations, the mathematical model of the system was established. By simulation, the corresponding LQ optimal controller was designed and the PWM signals were generated. The comparison of the simulation and experiment results show that LQ optimal control method with PWM technique employing high speed On/Off solenoid valve can provide better system performance and a high position precision is obtained.
文摘High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system.However,traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously.A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system.A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design.Mathematical models of the opening process and flow rate of the valve are established.Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response.Corresponding formulas to solve 4 parts of the response time are derived.Key factors that influence the opening response time are analyzed.According to the mathematical model of the valve,a simulation of the opening process is carried out by MATLAB.Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve.Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool.The experimental results are in agreement with the simulated results,therefore the validity of the theoretical analysis is verified.Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa.The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s.According to the result of the load driving test,the valve can meet the demands of the driving system.The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.
基金Supported by the National Natural Science Foundation of China(51076014)the Research Fund for the Doctoral Program of Higher Education(20101101110011)
文摘Influence of eddy current on transient characteristics of common rail injector solenoid valve was studied in this paper. Experimental investigations of drive current and power source volt- age of both drive current ascending and descending process were conducted on a common rail injec- tor solenoid valve. A new discretizing calculation method of solenoid valve flux linkage was put for- ward for the first time based on the experimental results and drive circuit principle, and flux linkage of both drive current ascending and descending process were evaluated. New inductance calculation methods for drive current ascending and descending process respectively were also presented. Influ- ence of parasitic inductance was evaluated. Results indicate that the air gap, under which the transi- ent flux linkage of the solenoid valve is the biggest, varies with drive current due to eddy current. Flux linkage of drive current descending process is bigger than that of drive current ascending process under the same drive current and the same air gap width. Eddy current can reduce the delay between the time that drive current begins to descend and the time that armature begins to move downward. Inductance of drive current descending process is bigger than that of drive current as- cending process over larger scope of drive current, but the difference becomes smaller with the in- creasing of air gap width. The differences of both flux linkage and inductance between drive current ascending and descending process are caused by the eddy current in core and armature materials.
文摘The following article has been retracted due to the investigation of complaints received against it. The Editorial Board found that substantial portions of the text came from other published papers. The scientific community takes a very strong view on this matter, and the Health treats all unethical behavior such as plagiarism seriously.This paper published in Vol.4 No. 3,316-322(pages), 2013, has been removed from this site.
基金supported by National Natural Science Foundation of China(Grant No.51175362)
文摘Currently, most researches use signals, such as the coil current or voltage of solenoid, to identify parameters; typically, parameter identification method based on variation rate of coil current is applied for position estimation. The problem exists in these researches that the detected signals are prone to interference and difficult to obtain. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which adds a new group of secondary winding to the coil of the ordinary switching electromagnet. On the basis of electromagnetic coupling theory analysis and simulation research of the magnetic field regarding the primary and secondary winding coils, and in accordance with the fact that under PWM control mode varying core position and operating current of windings produce different characteristic of flux increment of the secondary winding. The flux increment of the electromagnet winding can be obtained by conducting time domain integration for the induced voltage signal of the extracted secondary winding, and the core position from the two-dimensional fitting curve of the operating winding current and flux-linkage characteristic quantity of solenoid are calculated. The detecting and testing system of solenoid core position is developed based on the theoretical research. The testing results show that the flux characteristic quantity of switching electromagnet magnetic circuit is able to effectively show the core position and thus to accomplish the non-displacement transducer detection of the said core position of the switching electromagnet. This paper proposes a new method for detecting the core position by using flux characteristic quantity, which provides a new theory and method for switch solenoid to control the proportional valve.
文摘An algorithm for precisely calculating the inductance of a three-section solenoid is presented, which is based on summing the layer self-inductances and the mutual inductances. A theoretical model with ex plicit expressions is firstly developed to calculate the self-inductance of a single layer, and then numerical calcu lation of the mutual inductance between two layers is introduced. Using the presented computation method, the inductance of a solenoid designed in the experiment is successfully calculated (4.30 mH), which has a difference of less than 1% from the experimental data.
文摘Objective A novel high-speed three-way solenoid valve is developed, which is used for the common-rail injection system equipped on DME powered engine. In order to improve the dynamic response performance of the three-way solenoid. Methods Experimental studies have been conducted to investigate the effects of spool stroke, drive voltage, negative demagnetizing pulse and two drive schemes on the dynamic response performance of the three-way solenoid valve. Results The results show that the dynamic response performance of the three-way solenoid valve can be remarkably improved by shortening the spool stroke and increasing the drive voltage. Simultaneously, the difference between the response time of closing valve and that of opening valve decreases. At each different drive voltage, there exists an optimal negative demagnetizing pulse corresponding to the same positive exciting pulse. At this optimal pulse, the dynamic response performance of the three-way solenoid valve is the best. In addition, the high drive voltage can lead to the smaller optimal negative demagnetizing pulse. It is also indicated from the experiments that the dynamic response performance of the three-way solenoid valve is better when the NO.1 drive scheme is adopted. The lower drive voltage results in the larger difference between the dynamic response performances for the two drive schemes. Conclusion The dynamic response performance of a novel three-way solenoid valve is good.
文摘A central solenoid model coil will be set up to develop and verify the technique for the full-size central solenoid coil of the China Fusion Engineering Test Reactor.In case of quench and failures of superconducting coils,the quench protection(QP)system,which employs fuse-based commutation technology,is designed.This paper presents an analytical model to investigate the commutation process in the QP circuit.The model consists of the QP circuit equations,the breaker arc model,the fuse pre-arc model,and the fuse arc model.The model is employed in the whole commutation process including current transfer from breaker branch to the fuse branch model,then from fuse branch to the discharge resistor branch,and current decrease to zero in the discharge resistor.The experiment result verified the effectiveness of the presented model.The model might be helpful for design of the fuse and optimization of the commutation circuit.
文摘We analyze the familiar effect of the pulling of a magnetizable rod by a magnetic field inside a solenoid. We find that the analogy with the pulling of a dielectric slab by a charged capacitor is not as direct as usually thought. Indeed, there are two possibilities to pursue the analogy, according to the correspondence used,?either E → B and D → H, or E?→ H and D?→ B. One of these results in an incorrect sign in the force, while the other gives the correct result. We avoid this ambiguity in the usual energy method applying a momentum balance equation derived from Maxwell’s equations. This method permits the calculation of the force with a volume integration of a force density, or with a surface integration of a stress tensor. An interpretation of our results establishes that the force acts at the interface and has its origin in Maxwell′s magnetic stresses at the medium-vacuum interface. This approach provides new insights and a new perspective of the origin of this force.
基金National Meg-Science Engineering Project of the Chinese Government.
文摘The central solenoid (CS) composed of cable-in-conduit (CIC) type conductor is animportant part of the HT-7U device. The CS coils can be considered from the viewpoint of micro-mechanics as a composite material. And then, the residual stiffness is computed according to themicro-damage modeling of continuum damage mechanics. These material properties have beenused as input data for finite element method (FEM) analysis. In this paper the computationalanaysis of the stress and the displacement on the central solenoid are made by the finite elementanalysis system COSMOS/M2.0 under Operating temperature. According to the analytical results,the CS coils are all satisfied with designed safety criteria.
文摘The central solenoid is an important part of the HT-7U device. In this paper, the computational analysis of the stress and the displacement on the pre-load structures of the central solenoid have been made by the finite element analysis system COSMOS/M2.0 under room and/or operating temperature. According to the analytical results, the clip aprons and compression plates are all satisfied with safety design criteria.
文摘The results of the preliminary development of the HTS conductor based on the VS-type design and parallel stacks for the central solenoid of the compact thermonuclear reactor TRT are presented. One of the main problems that need to be solved for the successful implementation of such projects is the creation of high-current high-temperature superconducting (HTS) conductors for Toroidal Field coils (TF) and Central Solenoid (CS) sections. The conductor must have a high engineering current density of at least 90 A/mm<sup>2</sup>. The induction of the magnetic field in the central solenoid reaches 14 T, which leads to the occurrence of large mechanical stresses due to the influence of Lorentz forces. Like many large magnets, CS has a lot of stored energy. For the safe withdrawal of stored energy from the magnet, it requires the inclusion of elements in the conductor that provide an acceptable level of electrical voltage and heating of the conductor insulation. Thus, a sufficient amount of stabilizing and reinforcing materials should be placed in the conductor. In addition, the “cable-in-conduit” type of conductor must have channels for pumping the refrigerant. Two fundamentally different versions of the conductor based on radially arranged REBCO tapes and on the basis of pre-assembled tape packages are considered. Based on the analysis of the magnetic field distribution in the conductor by finite element method, the design characteristics of the proposed conductors under various operating modes of the electromagnetic system (EMS) of the tokamak TRT was evaluated. The results of the evaluation of the current carrying capacity of the conductor and the estimation of energy losses in a changing magnetic field in comparison with known methods are also presented.
文摘A widespread assertion has existed for a long time, believing the external field of an infinitely long solenoid should be zero, but it is proofed to be wrong in this work. The components of magnetic flux density of current-carrying, closely wound cylindrical solenoids are calculated. At a distant field point, the external field definitely has a nonzero component, being equal to that of a straight wire of equal length. Since this equivalence is length-independent, it still holds true for ideal solenoids having infinite length. Hence the incorrect and still spreading inference about long solenoids should be rectified. Furthermore, theoretical and experimental discussions involving solenoids should be reviewed again carefully.