期刊文献+
共找到8,504篇文章
< 1 2 250 >
每页显示 20 50 100
Synthesis and Solid Phase Extraction Performance Study of NNAL-specific Molecularly Imprinted Polymers Using Dummy Templates 被引量:2
1
作者 张志丹 郑赛晶 +3 位作者 杨俊 王维妙 刘百战 朱晓兰 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2013年第3期361-368,I0004,共9页
Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(a... Dummy molecularly imprinted polymers (DMIPs) for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) were produced using three structural analogues as dummy template molecules. The chosen analogues were 4-(acetymethylamino)-1-(3-pyridyl)-butanol, 4- (methylamino)-1-(3-pyridyl)-1-butanol, and 1-(3-pyridyl)-1,4,-butanediol. The molecular recognition characteristics of the produced polymers were evaluated by X-ray photoelec- tron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FT-IR). Interactions between NNAL and methacrylic acid should be cooperative hydrogen bonds while the ni- trogen atom of the pyridine ring and the oxygen atom of the nitroso group in NNAL are two of the hydrogen-bond acceptors. It was further demonstrated that DMIP synthesized by 4-(acetymethylamino)-1-(3-pyridyl)-butanol had the best binding performance by XPS and FT-IR. Then dummy molecularly imprinted solid phase extraction (DMISPE) was developed for the determination of the analyte using the hit polymer as the sorbing material. Under optimal conditions, the recovery of NNAL dissolved in standard solution reached 93%. And the investigated polymer exhibited much higher binding of NNAL when nicotine was acted as the competitive molecule. Also the proposed method was applied to the measurement of NNAL spiked in blank urine samples with recoveries ranging from 87.2% to 101.2%. 展开更多
关键词 Molecularly imprinted polymer Dummy template 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanol solid phase extraction
下载PDF
Determination of resveratrol in red wine by solid phase extraction-flow injection chemiluminescence method 被引量:7
2
作者 Juan Juan Ren Hai Yan Liu +2 位作者 Yu Hong Hao Pin Gang He Yu Zhi Fang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第8期985-988,共4页
A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and H... A sensitive flow injection chemiluminescence method has been developed for the detection of resveratrol in red wine based on the fact that resveratrol can greatly enhance chemiluminescence reaction between KMnO4 and HCHO in sulfuric acid medium. Analytes were pre-concentrated on solid sorbents (C18 solid-phase extraction cartridges). Under the optimum conditions, the proposed method allows the measurement of resveratrol over the range of 1.32 × 10^-8 to 1.32 × 10^-5 mol/L with a detection limit of 3.30 ×10^-9 mol/L, and the relative standard deviation for 1.32 ×10^-5 mol/L resveratrol (n = 11) is 3.8%. This method has been successfully applied for the determination of the resveratrol in red wine. Furthermore, the possible reaction mechanism was also discussed. 展开更多
关键词 RESVERATROL solid phase extraction How-injection chemiluminescence Potassium permanganate FORMALDEHYDE
下载PDF
Development trend and prospect of solid phase extraction technology 被引量:10
3
作者 Chao Zhang Huifang Xing +2 位作者 Liangrong Yang Pengfei Fei Huizhou Liu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第2期245-255,共11页
Solid phase extraction is widely used in sample pretreatment,concentration and analysis processes due to high selectivity and suitability for low concentration sample system.In this review,we systematically summarized... Solid phase extraction is widely used in sample pretreatment,concentration and analysis processes due to high selectivity and suitability for low concentration sample system.In this review,we systematically summarized and discussed the development trends of solid phase extraction by bibliometrics method.By analyzing papers output scale,the research and development direction of solid phase extraction technology is prospected.We also give an overview on current strategies of novel solid phase extraction from the separation medium and separation technology.The paper aims to describe the global research profile and the development trends of solid phase extraction,to help researchers to accurately grasp the research trend and to provide support for scientific research institutions to formulate scientific policies and strategic plans.Furthermore,the prospect of the development and application of solid phase extraction is also discussed. 展开更多
关键词 solid phase extraction Papers output scale Quality of research Novel technology
下载PDF
Solid Phase Extraction Chemiluminescence Determination of Methamidaphos on Vegetables 被引量:5
4
作者 LI Xiao-zhou GUAN Ting-ting +2 位作者 ZHOU Chi YIN Ji-qiu ZHANG Yi-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2006年第1期21-24,共4页
The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing e... The determination of the methamidaphos pesticide residue on vegetables with a simple solid phase extract(SPE) flow injection(FI) -chemiluminescence(CL) method is described. The method is based on the enhancing effect of methamidaphos on the CL reaction of luminol with hydrogen peroxide in an alkaline solution. Under the optimal conditions, the CL intensity is linear to the methamidaphos mass concentration in a range of 0. 2-13μg/mL ( r= 0. 9992). The detection limit(3σ) is 0. 047μg/mL. The relative standard deviations for the analysis of three samples are 1.8%, 2.5% and 3.7% ( n = 5 ), respectively. The recovery is in a range of 90%-109% by the method. In this work, this method was successfully applied to the determination of the methamidaphos residue on some vegetable samples. 展开更多
关键词 CHEMILUMINESCENCE Flow injection solid phase extraction Methamidaphos
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:6
5
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 Liquid chromatography–tandem mass SPECTROMETRY On-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Simultaneous Determination of Bisphenols and Alkylphenols in Water by Solid Phase Extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry 被引量:4
6
作者 SHAN Xiao Mei SHEN Deng Hui +2 位作者 WANG Bing Shuang LU Bei Bei HUANG Fa Yuan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第6期471-474,共4页
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ... To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. 展开更多
关键词 UPLC BPA Simultaneous Determination of Bisphenols and Alkylphenols in Water by solid phase extraction and Ultra Performance Liquid Chromatography-tandem Mass Spectrometry MASS
下载PDF
Determination of Sulfadimidine in Royal Jelly by C_(18)-functionalized Magnetic Silica Nanoparticles Solid Phase Extraction-High Performance Liquid Chromatography-Tandem Mass Spectrometry
7
作者 李金峰 李颖 +3 位作者 蒋原 薛峰 戴劲 朱海 《Agricultural Science & Technology》 CAS 2012年第11期2278-2280,共3页
[Objective] This study aimed to develop a method of C_18-functionalized magnetic silica nanoparticles solid phase extraction-high performance liquid chro- matography-tandem mass spectrometry for the determination of s... [Objective] This study aimed to develop a method of C_18-functionalized magnetic silica nanoparticles solid phase extraction-high performance liquid chro- matography-tandem mass spectrometry for the determination of sulfadimidine in royal jelly. [Method] The royal jelly samples were pretreated by MCX SPE column and C_18-functionalized magnetic silica nanoparticles, and the purified samples were de- tected by HPLC-MS/MS. [Result] The detection method showed a good linear rela- tionship in the range of 5-80 ugkg (r=0.993 1). The recovery ranges were between 93%- 104% with the relative standard deviations (RSD) below 11.3%. [Conclusion] Combined with automation equipment, the method is simple, fast, time-saving, and easy to real- ize the automation of sulfadimidine in the royal jelly samples before determination. 展开更多
关键词 solid phase extraction Magnetic silica nanoparticles Sulfadimidine Highperformance liquid chromatography-tandem mass spectrometry
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
8
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes solid phase extraction (SPE) Flame atomic absorption spectrometry
下载PDF
Comparison of Different Cartridges of Solid Phase Extraction for Determination of Polyphenols in Tobacco by UPLC/MS/MS and Multivariate Analysis 被引量:1
9
作者 ZHANG Xia LIU Wei +6 位作者 XU Yong YANG Liu KONG Wei-song RUI Xiao-dong YANG Shuai CHEN Yong-kuan MIAO Ming-ming 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第4期550-556,共7页
The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/... The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and multivariate analysis.Several adsorbing materials of SPE(C18,NH2,SAX and OASIS) were investigated.It was found that the C18 and OASIS cartridges can not only speed up the purification process,but also simplify the SPE operation.A UPLC/MS/MS was used for the determination of polyphenols in tobacco samples after purification.All analytes were separated and determined in 2min.The limit of detection was 0.05 ng/mL.Cluster analysis(CA) and principal component analysis(PCA) were used for the analysis of 4 varieties(flue-cured tobacco,oriental tobacco,sun-cured tobacco and burley) in order to interpret the effect of planting and machining process on the concentration of polyphenols.The different types of tobacco samples could be easily clustered by CA.PCA on the chemical composition of tobacco resulted in two principal components(PCs) that take 84.2% of the total variance.The PCA and CA indicate that the polyphenols can be used for distinguishing tobacco types. 展开更多
关键词 solid phase extraction POLYPHENOL Ultra-high performance liquid chromatography/tandem mass spectro-metry(UPLC/MS/MS) TOBACCO Cluster analysis Principal component analysis
下载PDF
Solid phase extraction of methomyl and thiodicarb from environmental water with an activated carbon cartridge and their determination by HPLC
10
作者 Chen, Yan-Jun Lu, Ying-Hua +1 位作者 Liu, Jun Chen, Ya-Min 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2000年第1期100-104,共5页
A solid phase extraction procedure of methomyl and thiodicarb from environmental water was presented. This method utilizes a 40—60 mesh activated carbon cartridge and high performance liquid chromatography (HPLC). Th... A solid phase extraction procedure of methomyl and thiodicarb from environmental water was presented. This method utilizes a 40—60 mesh activated carbon cartridge and high performance liquid chromatography (HPLC). The 40—60 mesh activated carbon works faster and yield higher adsorption efficiency. Detection limits of methomyl and thiodicarb in environmental water are 0 1 μg/L and 0 2 μg/L, respectively. Average recoveries of fortified methomyl and thiodicarb in water are in the range of 90 7%—98 8% and 88 9%—103 6%, respectively. The relative standard deviations are lower than 7%. This method is simple, rapid, accurate and precise. 展开更多
关键词 HPLC solid phase extraction activated carbon METHOMYL thiodicarb CLC number: X592 Document code: A
下载PDF
Determination of Fe, Cu, and Zn in Water Samples by Microcolumn Packed with Multiwalled Carbon Nanotubes as a Solid Phase Extraction Adsorbent Using ICP-MS
11
作者 A. Ahmad H.M. Al-Swaidan 《Journal of Environmental Science and Engineering》 2011年第4期410-419,共10页
The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasm... The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water. 展开更多
关键词 Multiwalled carbon nanotubes (MWNTs) solid phase extraction (SPE) heavy metals nitric acid (HNO3) PTFE micro-column inductively coupled plasma mass spectrometry (ICP-MS).
下载PDF
Determination of volatile organic compounds in river water by solid phase extraction and gas chromatography 被引量:4
12
作者 M.A.Mottaleb M.Z.Abedin M.S.Islam 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第3期497-501,共5页
A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile ... A simple, rapid, and reproducible method is described employing solid phase extraction(SPE) using dichloromethane followed by gas chromatography(GC) with flame ionization detection(FID) for determination of volatile organic compound(VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene(BTEXC) in the sample collected from the surface or 15 cm depth of water. Two hundred ml of n hexane pretreated and filtered water samples were applied directly to a C 18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0 104 to 0 372 μg/ml. The highest concentration of benzene was found as 0 372 μg/ml with a relative standard deviation(RSD) of 6 2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C 18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4℃ with a 2 7% RSD. 展开更多
关键词 solid phase extraction river water environmental analysis VOC recoveries
下载PDF
Analysis of trace mercury in water by solid phase extraction using dithizone modified nanometer titanium dioxide and cold vapor atomic absorption spectrometry 被引量:5
13
作者 MA Xiaoguo HUANG Bei CHENG Meiqing 《Rare Metals》 SCIE EI CAS CSCD 2007年第6期541-546,共6页
A new method for analysis of trace mercury in water samples was developed, based on the combination of preconcentration/separation using dithizone-modified nanometer titanium dioxide (TiO2) as a solid phase extracta... A new method for analysis of trace mercury in water samples was developed, based on the combination of preconcentration/separation using dithizone-modified nanometer titanium dioxide (TiO2) as a solid phase extractant and determination by cold vapor atomic adsorption spectrometry (CVAAS). Dithizone was dissolved with alcohol and loaded on the surface of nano-sized TiO2 powders by stirring. The static adsorption behavior of Hg^2+on the dithizone-modified nanoparficles was investigated in detail. It was found that excellent adsorption ratio for Hg^2+ could be obtained in the pH range of 7-8 with an oscillation time of 15 rain, and a 5 mL of 3.5 mol·L^-1 HCI solution could quantitatively elute Hg^2+ from nanometer TiO2 powder. Common coexisting ions caused no obvious influence on the determination of mercury. The mechanisms for the adsorption and desorption were discussed. The detection limit (30) for Hg^2+ was calculated to be 5 ng·L^-1. The proposed method was applied to the determination of Hg^2+ in a mineral water sample and a Zhujiang River water sample. By the standard addition method, the average recoveries were found to be 94.4%-108.3% with RSD (n = 5) of 2.9%-3.5%. 展开更多
关键词 analytical chemistry MERCURY solid-phase extraction TiO2 nanoparticle cold vapor atomic adsorption spectrometry (CVAAS)
下载PDF
Degradation Dynamics and Residue Analysis of Flubendiamide in Cabbage and Soil by Liquid Chromatography-Tandem Mass Spectrometry with Dispersive Solid Phase Extraction 被引量:2
14
作者 Xiaojun Chen Ping Wang +3 位作者 Zhiyuan Meng Si Chen Haotian Gu Xiaoling Sha 《Agricultural Sciences》 2014年第10期850-857,共8页
To formulate a scientific basis for a reasonable spray dose and safe interval period of 20% flubendiamide water dispersible granule (WDG) on controlling vegetable pests, degradation dynamics of flubendiamide in cabbag... To formulate a scientific basis for a reasonable spray dose and safe interval period of 20% flubendiamide water dispersible granule (WDG) on controlling vegetable pests, degradation dynamics of flubendiamide in cabbage and soil was analyzed in this study. Dissipation and residue of flubendiamide in 20% flubendiamide WDG in cabbage and soil under field conditions were investigated by liquid chromatography-tandem mass spectrometry with dispersive solid phase extraction. Results showed that the degradation dynamic equations of flubendiamide in cabbage and soil were based on the first-order reaction dynamic equations. The half-lives of the degradation of flubendiamide were 3.51 d to 3.96 d and 3.43 d to 3.87 d in the cabbage of Yangzhou and Jingzhou, respectively, and 4.42 d to 5.13 d and 4.37 d to 4.99 d in the soil of Yangzhou and Jingzhou, respectively. The terminal residues of flubendiamide in the cabbage of Yangzhou and Jingzhou were 0.0247 mg·kg-1 to 0.0393 mg·kg-1 and 0.0225 mg·kg-1 to 0.0273 mg·kg-1, respectively, when 20% flubendiamide WDG was applied at a dose of0.050g·m-2. Flubendiamide is safe to be applied in cabbage fields at the recommended dose. 展开更多
关键词 FLUBENDIAMIDE DISPERSIVE solid phase extraction LC-MS/MS Degradation RESIDUE
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
15
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty solid phase extraction Ultra performance liquid CHROMATOGRAPHY TANDEM mass SPECTROMETRY MICROCYSTIN MC-LR China
下载PDF
Development of a Rapid and Efficient Liquid Chromatography Method for Determination of Gibberellin A4 in Plant Tissue, with Solid Phase Extraction for Purification and Quantification 被引量:1
16
作者 Julia Medrano Macías Rahim Foroughbakhch Pournavab +1 位作者 Manuel Humberto Reyes-Valdés Adalberto Benavides-Mendoza 《American Journal of Plant Sciences》 2014年第5期573-583,共11页
A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithe... A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995. 展开更多
关键词 Dasyrilon cedrosanum Epithelantha micromeris PHYTOHORMONE Separation Plant Growth REGULATORS Reverse phase Liquid Chromatography solid phase extraction
下载PDF
Fiber-in-Tube Solid Phase Extraction (FIT-SPE) for Miniaturized Sample Preparation Process
17
作者 JINNO Kiyokatsu SAITO Yoshihiro 《色谱》 CAS CSCD 北大核心 2004年第4期297-300,共4页
关键词 管中纤维固定相萃取 样品处理 制备 微型化
下载PDF
Determination of an Organophosphorus Pesticide Chlorpyrifos in Seawater by Solid Phase Extraction-Gas Chromatography
18
作者 Liu Zhiju Ji Tiemei +2 位作者 Tian Hua Jiang Min Xu Jianping 《Meteorological and Environmental Research》 CAS 2016年第6期51-53,57,共4页
Solid phase extraction(SPE) and gas chromatography(GC) were combined to establish a method for detecting traces of chlorpyrifos in seawater,and the effects of extraction column type,water sample pH and salinity,and el... Solid phase extraction(SPE) and gas chromatography(GC) were combined to establish a method for detecting traces of chlorpyrifos in seawater,and the effects of extraction column type,water sample pH and salinity,and eluant type on the recovery rate of chlorpyrifos were analyzed. The results show that the linear range of the method was 0.02-2.0 μg/ml,and the correlation coefficient was 0.9993; the recovery rate of chlorpyrifos in the seawater samples to which the standard sample of chlorpyrifos averaged 101%-114%; MDL was 0.00851μg/L,and the lower limit of determination for chlorpyrifos was 0.034μg/L; the relative standard deviation ranged from 1.52% to 6.21%(n = 6). The method is simple,sensitive and accurate and has good repeatability. It is suitable for the determination of traces of chlorpyrifos in seawater. 展开更多
关键词 solid phase extractION GAS CHROMATOGRAPHY CHLORPYRIFOS Seawater China
下载PDF
Determination of Quinolone Antibiotics in Water Using Solid Phase Extraction-High Performance Liquid Chromatography-Fluorescence Method
19
作者 WANG Qiao-jun YI Ru-han MO Ce-hui 《Animal Husbandry and Feed Science》 CAS 2011年第2期45-48,共4页
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf... [Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis. 展开更多
关键词 solid-phase extraction High performance liquid chromatography WATER Quinolone antibiotics
下载PDF
Investigation on the insecticidal limonoid content of commercial biopesticides and neem extract using solid phase extraction
20
作者 Ji-Won Lee Cho-Long Jin +3 位作者 Ki Chang Jang Geun-Hyoung Choi Hee-Dong Lee Jin Hyo Kim 《Journal of Agricultural Chemistry and Environment》 2013年第4期81-85,共5页
Neem extract is an alternative insecticide for organic farming and is an allowed component for commercial biopesticide in Korea. However, crop protection properties are not consistent in commercial products. In this r... Neem extract is an alternative insecticide for organic farming and is an allowed component for commercial biopesticide in Korea. However, crop protection properties are not consistent in commercial products. In this report, quantitative analysis of commercial biopesticides for the four insecticidal limonoids of neem extract-azadirachtin A, azadirachtin B, deacetylsalannin and salannin, was conducted through solid phase extraction method with lipophilic-hydrophilic balanced material. The recoveries of the four limonoids ranged from 80.5% to 105%, and their limit of quantitation ranged from 0.028 mg/L to 0.356 mg/L. On the five imported neem extracts, the total contents of the four bioactive limonoids extracted were from 321 mg/L to 5810 mg/L, but there were big variations in the relative composition of the limonoids. The total limonoidal concentrations in 23 commercial bio-pesticides made from neem showed from below LOQ to 7190 mg/L with significant differences in the relative composition. These differences determine the biopesticide’s efficacy on pests, therefore, tracking the active ingredients is necessary for the quality control of commercial bio-pesticides. 展开更多
关键词 solid phase extraction Azadirachitn Salannin Quantitative Analysis BIOPESTICIDE
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部