To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatogr...A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China.展开更多
An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading,...An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.展开更多
建立了固相萃取-超高效液相色谱-串联质谱法(SPE-UPLC-MS/MS)快速测定鸡粪中37种抗菌药物含量的方法。鸡粪经冻干制备,80%乙腈(含0.1%甲酸)提取,Oasis PRiME HLB通过式固相萃取净化后,利用UPLC-MS/MS测定抗菌药物含量。结果表明,37种抗...建立了固相萃取-超高效液相色谱-串联质谱法(SPE-UPLC-MS/MS)快速测定鸡粪中37种抗菌药物含量的方法。鸡粪经冻干制备,80%乙腈(含0.1%甲酸)提取,Oasis PRiME HLB通过式固相萃取净化后,利用UPLC-MS/MS测定抗菌药物含量。结果表明,37种抗菌药物浓度在0.40~200.0ng/mL范围内线性关系良好,相关系数(R^(2))大于0.996,检出限(LOD)为1μg/kg,定量限(LOQ)为4μg/kg。37种抗菌药物在3个浓度添加标水平(LOQ、5倍LOQ、10倍LOQ)下的回收率为63.5%~104.2%,批内相对标准偏差为1.47%~10.5%,批间相对标准偏差为2.39%~14.2%。所建立方法准确、快速、灵敏、稳定,可实现鸡粪中37种抗菌药物的同时快速测定。展开更多
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
基金Supported by the Environmental Monitoring and Research Foundation of Jiangsu Province(1621)the Taihu Lake Pollution Prevention and Control Project of Jiangsu Province(TH2016301)Postgraduate Research and Practice Innovation Program of Jiangsu Province in 2016(KYLX16_0813)
文摘A method was developed for the detection of seven microcystins(microcystin-LR, RR, YR, LA, LY, LW and LF) in surface water using automatic solid-phase extraction(A-SPE) coupled with ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS). The automated solid-phase extraction system was used to extract microcystins(MCs) from water samples. UPLC-MS/MS was used to determine MCs concentrations in just 5 min. Method detection limits were from 0.3 to 0.9 ng/L, microcystin recoveries ranged from 83.8% to 114%, and the relative standard deviation(RSD) varied from 5.6% to 12.5%. This analytical approach was found to be simple, highly sensitive, accurate, which required little manual operation. Additionally, to validate this analytical method, A-SPE+UPLC-MS/MS was applied to characterize the concentration of MCs in Taihu Lake, Wuxi, China.
基金Department of Chemistry at Mississippi State University for financial support for this project
文摘An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.
文摘建立了固相萃取-超高效液相色谱-串联质谱法(SPE-UPLC-MS/MS)快速测定鸡粪中37种抗菌药物含量的方法。鸡粪经冻干制备,80%乙腈(含0.1%甲酸)提取,Oasis PRiME HLB通过式固相萃取净化后,利用UPLC-MS/MS测定抗菌药物含量。结果表明,37种抗菌药物浓度在0.40~200.0ng/mL范围内线性关系良好,相关系数(R^(2))大于0.996,检出限(LOD)为1μg/kg,定量限(LOQ)为4μg/kg。37种抗菌药物在3个浓度添加标水平(LOQ、5倍LOQ、10倍LOQ)下的回收率为63.5%~104.2%,批内相对标准偏差为1.47%~10.5%,批间相对标准偏差为2.39%~14.2%。所建立方法准确、快速、灵敏、稳定,可实现鸡粪中37种抗菌药物的同时快速测定。