A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by N,N′-disalicylideneethylenediamine (DESDA) ...A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by N,N′-disalicylideneethylenediamine (DESDA) and atomic absorption spectrometry was presented. The method is based on complex formation on the surface of the ENVI-18 DISK^TM disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about be 1000 mL providing a preconcentration factor of 500. The maximum capacity of the disks was found to be (389±4) μg for Cu^2+. The limit of detection of the proposed method is 5 ng per liter. The method was applied to the extraction and recovery of copper in different water samples.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
对美国3M公司的锶特效固相萃取片(EmporeTMStrontium Rad Disk)分离水溶液中锶离子的性能进行了系统研究,包括酸度、流速、样品体积对吸附百分比的影响,吸附容量的测定,137 Cs和99 Tc在萃取片上的吸附情况等,并对萃取片上90Sr的解吸及片...对美国3M公司的锶特效固相萃取片(EmporeTMStrontium Rad Disk)分离水溶液中锶离子的性能进行了系统研究,包括酸度、流速、样品体积对吸附百分比的影响,吸附容量的测定,137 Cs和99 Tc在萃取片上的吸附情况等,并对萃取片上90Sr的解吸及片上90Sr的放射性测量进行了研究。在此基础上,给出了萃取片法分析环境水中90Sr的推荐程序。样品体积为1L,液闪测量时间为1h时,分析程序的最小可探测活度浓度为0.033Bq/L。最后应用一些实际环境水样对该程序进行了检验。展开更多
文摘A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by N,N′-disalicylideneethylenediamine (DESDA) and atomic absorption spectrometry was presented. The method is based on complex formation on the surface of the ENVI-18 DISK^TM disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about be 1000 mL providing a preconcentration factor of 500. The maximum capacity of the disks was found to be (389±4) μg for Cu^2+. The limit of detection of the proposed method is 5 ng per liter. The method was applied to the extraction and recovery of copper in different water samples.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.
文摘对美国3M公司的锶特效固相萃取片(EmporeTMStrontium Rad Disk)分离水溶液中锶离子的性能进行了系统研究,包括酸度、流速、样品体积对吸附百分比的影响,吸附容量的测定,137 Cs和99 Tc在萃取片上的吸附情况等,并对萃取片上90Sr的解吸及片上90Sr的放射性测量进行了研究。在此基础上,给出了萃取片法分析环境水中90Sr的推荐程序。样品体积为1L,液闪测量时间为1h时,分析程序的最小可探测活度浓度为0.033Bq/L。最后应用一些实际环境水样对该程序进行了检验。