Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has ...Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has been used as intermediate layer and solid contact between the electron-conducting graphite paste substrate and the ion-conducting polyvinylchloride (PVC)-containing membrane with the immobilized ionophore. For the nitrate- and ammonium-selective electrodes, tridodecylmethylammonium nitrate (TDMA-NO3) and nonactin have been used as ion-complexing compounds, respectively. Both ISEs show nearly Nernstian response in the linear range from 10-5 mol/L to 10-1 mol/L with average slopes of >58 mV/decade. The ISEs possess short response times (<20 s).展开更多
Novel solid-contact perchlorate sensors based on cobalt phthalocyanine-C-monocarboxylic acid (I), and cobalt phthalocyanine-C,C,C,C-tetracarboxylic acid (II) as free ionophores and covalently attached to polyacryla- m...Novel solid-contact perchlorate sensors based on cobalt phthalocyanine-C-monocarboxylic acid (I), and cobalt phthalocyanine-C,C,C,C-tetracarboxylic acid (II) as free ionophores and covalently attached to polyacryla- mide (PAA)—ionophores III and IV, respectively were prepared. The all solid-state sensors were constructed by the application of a thin film of a polymer cocktail containing a phthalocyanine ionophore and cetyltrimethylammonium bromide (CTMAB) as a lipophilic cationic additive onto a gold electrode precoated with the conducting polymer poly (3,4-ethylenedioxythiophene) (PEDOT) as an ion and electron transducer. The sensor with 10.3% of ionophore (III) covalently attached to plasticizer-free poly (butyl methacrylate-co-do- decyl methacrylate) (PBDA) exhibited a good selectivity for perchlorate and discriminated many ions, in- cluding F–, Cl–, Br–, I–, SCN–, , S2– and . The covalent attachment of the ionophore to the polymer resulted in a near-Nernstian anionic slope of –62.3 mV/decade whereas a super-Nernstian slope of –79.9 mV/ decade was obtained for the free ionophore. The sensor covered a linear concentration range of 5 × 10–9 - 1 × 10–2 mol?L–1 with a lower detection limit (LDL) of 1 × 10–9 mol?L–1 and gave a stable response over a pH range of 4 - 10.5. The all-solid state sensors were utilized for the selective flow injection potentiometric determination of perchlorate in natural water and human urine samples in the nanomolar concentration range.展开更多
The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulf...The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.展开更多
In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjug...In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjugated polymer, thieno[3,2-b]thiophene (LCPT), was investigated in fabricating Cu2+-selective electrodes for the first time. The resulting electrodes were characterized by electrochemical impedance spectroscopy (EIS), chronopotentiometry, and the water layer test. Results proved that the active LCPT facilitates the ion-to-electron transduction, and avoids the detrimental aqueous layer formed at the interface of SC-ISEs.展开更多
A new solid-contact Ag~+-selective electrode was prepared with 9,10,12,13,24,25-hexahydro-5H,15H,23H-dibenzo [b,q][1,7,10,13,19,4,16]-entathiadiazacyclodocosine-6,16(7H,17H)-dione as ionophore,and cc,a-dihexylsexit...A new solid-contact Ag~+-selective electrode was prepared with 9,10,12,13,24,25-hexahydro-5H,15H,23H-dibenzo [b,q][1,7,10,13,19,4,16]-entathiadiazacyclodocosine-6,16(7H,17H)-dione as ionophore,and cc,a-dihexylsexithiophene(DH- 6T) ion-to-electron transducer.The sensor exhibited a working concentration range of 10~8 to 10^(-3) mol/L,with a near-Nernstian slope of 55.1±0.2 mV/dec and detection limit of 1.7×10^(-9) mol/L.The fabricated electrodes demonstrated excellent selectivity over the most common monovalent and divalent cations.展开更多
文摘Robust and easy-to-handle solid-contact ion-selective electrodes (SC-ISEs) based on graphite paste have been developed for the potentiometric detection of NO-3 and NH+4 in environmental samples. Polypyrrole (PPy) has been used as intermediate layer and solid contact between the electron-conducting graphite paste substrate and the ion-conducting polyvinylchloride (PVC)-containing membrane with the immobilized ionophore. For the nitrate- and ammonium-selective electrodes, tridodecylmethylammonium nitrate (TDMA-NO3) and nonactin have been used as ion-complexing compounds, respectively. Both ISEs show nearly Nernstian response in the linear range from 10-5 mol/L to 10-1 mol/L with average slopes of >58 mV/decade. The ISEs possess short response times (<20 s).
文摘Novel solid-contact perchlorate sensors based on cobalt phthalocyanine-C-monocarboxylic acid (I), and cobalt phthalocyanine-C,C,C,C-tetracarboxylic acid (II) as free ionophores and covalently attached to polyacryla- mide (PAA)—ionophores III and IV, respectively were prepared. The all solid-state sensors were constructed by the application of a thin film of a polymer cocktail containing a phthalocyanine ionophore and cetyltrimethylammonium bromide (CTMAB) as a lipophilic cationic additive onto a gold electrode precoated with the conducting polymer poly (3,4-ethylenedioxythiophene) (PEDOT) as an ion and electron transducer. The sensor with 10.3% of ionophore (III) covalently attached to plasticizer-free poly (butyl methacrylate-co-do- decyl methacrylate) (PBDA) exhibited a good selectivity for perchlorate and discriminated many ions, in- cluding F–, Cl–, Br–, I–, SCN–, , S2– and . The covalent attachment of the ionophore to the polymer resulted in a near-Nernstian anionic slope of –62.3 mV/decade whereas a super-Nernstian slope of –79.9 mV/ decade was obtained for the free ionophore. The sensor covered a linear concentration range of 5 × 10–9 - 1 × 10–2 mol?L–1 with a lower detection limit (LDL) of 1 × 10–9 mol?L–1 and gave a stable response over a pH range of 4 - 10.5. The all-solid state sensors were utilized for the selective flow injection potentiometric determination of perchlorate in natural water and human urine samples in the nanomolar concentration range.
基金We are grateful to the National Natural Science Foundation of China(22172040,21974031 and 22204026)the Project Funded by China Postdoctoral Science Foundation(2022M710859)+2 种基金the Department of Science and Techniques of Guangdong Province(2021A1515010180,2019B010933001)Guangzhou Municipal Science and Technology Bureau(202102010449)the Department of Guangdong Provincial Public Security(GZQC20-PZ11-FD084)fortheirfinancial support of thiswork.
文摘The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.
基金financially supported by the National Natural Science Foundation of China(No.21107134)Chinese Academy of Sciences(No.KZCX2-YW-JS208)+1 种基金the Natural Science Foundation of Shandong Province(No.JQ200814)the Taishan Scholar Program of Shandong Province
文摘In recent years, there has been a pronounced interest in solid-contact ion-selective electrodes (SC-ISEs), with emphasis on the use of conducting polymers as ion-to-electron transducer. In this work, a ladder conjugated polymer, thieno[3,2-b]thiophene (LCPT), was investigated in fabricating Cu2+-selective electrodes for the first time. The resulting electrodes were characterized by electrochemical impedance spectroscopy (EIS), chronopotentiometry, and the water layer test. Results proved that the active LCPT facilitates the ion-to-electron transduction, and avoids the detrimental aqueous layer formed at the interface of SC-ISEs.
基金financially supported by the National Natural Science Foundation of China(No.21107134)Chinese Academy of Sciences(No.KZCX2-YW-JS208)+1 种基金the Natural Science Foundation of Shandong Province (JQ200814)the Taishan Scholar Program of Shandong Province
文摘A new solid-contact Ag~+-selective electrode was prepared with 9,10,12,13,24,25-hexahydro-5H,15H,23H-dibenzo [b,q][1,7,10,13,19,4,16]-entathiadiazacyclodocosine-6,16(7H,17H)-dione as ionophore,and cc,a-dihexylsexithiophene(DH- 6T) ion-to-electron transducer.The sensor exhibited a working concentration range of 10~8 to 10^(-3) mol/L,with a near-Nernstian slope of 55.1±0.2 mV/dec and detection limit of 1.7×10^(-9) mol/L.The fabricated electrodes demonstrated excellent selectivity over the most common monovalent and divalent cations.