期刊文献+
共找到107篇文章
< 1 2 6 >
每页显示 20 50 100
Detection of Chlorides in Pore Water of Cement Based Materials by Potentiometric Sensors 被引量:1
1
作者 Franc vegl Kurt Kalcher +2 位作者 Yi Jung Grosse-Eschedor Magda Balonis Andrzej Bobrowski 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期232-237,共6页
Free chloride ions dissolved in pore water of cement based materials initiate the corrosion of steel rebars used for reinforcement of concrete and thus pose serious constant danger to the safety of reinforced concrete... Free chloride ions dissolved in pore water of cement based materials initiate the corrosion of steel rebars used for reinforcement of concrete and thus pose serious constant danger to the safety of reinforced concrete structures.The in-situ monitoring of the content of chlorides in pore water with second order Ag/AgCl electrodes is an elegant approach which, however,suffers from poor stability of Ag/AgCl electrodes in highly alkaline environment like pore water.In this work the electrochemical stability of plain and stabilized electrodeposited Ag/AgCl sensors in extreme alkaline conditions are presented. The electrochemical processes were elucidated which govern the potentiometric response of Ag/AgCl sensors and determine their performance.The results have shown suitable stability and reproducibility of stabilized Ag/AgCl sensors over five months, which was sufficient for laboratory testing of chloride ingress into cement based materials.The embedded calibrated sensor elements were used to monitor the chloride uptake into cylindrical mortar specimen dipped into simulated pore water containing about 3 wt% of chloride ions.The velocity of diffusing front and the diffusion coefficient of chloride ions in pore water of cylindrical mortar sample were estimated from concentration-time profiles determined by chloride sensors positioned at defined positions in the sample wall. 展开更多
关键词 chloride sensor chloride ingress Ag/AgCl potentiometric detection reinforced concrete CORROSION durability.
下载PDF
A NOVEL BITTER DETECTION BIOSENSOR BASED ON LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR 被引量:1
2
作者 CHUNSHENG WU LIPING DU +1 位作者 LIHUI MAO PING WANG 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2012年第2期34-40,共7页
This paper presents a novel biosensor for bitter substance detection on the basis of light addressable potentiometric sensor(LAPS).Taste receptor cells(TRCs)were used as sensitive elements,which can respond to differe... This paper presents a novel biosensor for bitter substance detection on the basis of light addressable potentiometric sensor(LAPS).Taste receptor cells(TRCs)were used as sensitive elements,which can respond to different bitter stimuli with extreme high sensitivity and speci-ficity.TRCs were isolated from the taste buds of rats and cultured on the surface of LAPS chip.Due to the unique advantages such as single-cell recording,light addressable capability,and noninvasiveness,LAPS chip was used as secondary transducer to monitor the responses of TRCs by recording extracelluar potential changes.The results indicate LAPS chip can effectively record the responses of TRCs to different bitter substances used in this study in a real-time manner for a long-term.In addition,by performing principal component analysis on the LAPS recording data,different bitter substances tested can be successfully discriminated.It is suggested this TRCsLAPS hybrid biosensor could be a valuable tool for bitter substance detection.With further improvement and novel design,it has great potentials to be applied in both basic research and practical applications related to bitter taste detection. 展开更多
关键词 Taste receptor cells bitter detection bitter signal transduction light addressable potentiometric sensor BIOsensor
下载PDF
Neurochip Based on Light-addressable Potentiometric Sensor
3
作者 Qingjun Liu Hua Cai +3 位作者 Ying Xu Lifeng Qin Lijiang Wang Ping Wang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期413-416,共4页
<正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current... <正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current neurochips,such as microelectrode array and field effect transistor array can be settled easily.Based on the theoretical analysis of the interface between cells and LAPS,spontaneously discharges of hippocampal neurons induced by Mg~ 2+)-free media treatment were recorded by LAPS.The results demonstrate that this kind of neurochip has potential to monitor electrophysiology of cultured cells in a non-invasive way. 展开更多
关键词 NEUROCHIP cell-based biosensor hippocampal neurons light-addressable potentiometric sensor
下载PDF
All-Solid-State Screen-Printed Sensors for Potentiometric Calcium(II) Determinations in Environmental Samples
4
作者 Johannes Schwarz Kathrin Trommer +1 位作者 Frank Gerlach Michael Mertig 《American Journal of Analytical Chemistry》 2018年第3期113-123,共11页
This paper describes preparation, characterization and electrochemical performance of novel planar miniaturized all-solid-state (ASS) screen-printed potentiometric sensors for the detection of Ca2+ ions in environment... This paper describes preparation, characterization and electrochemical performance of novel planar miniaturized all-solid-state (ASS) screen-printed potentiometric sensors for the detection of Ca2+ ions in environmental samples. Screen-printed graphite-based ion-selective electrodes (ISEs) and screen-printed reference electrodes based on silver-containing pastes have been applied in a space saving manner on common ceramic substrates with small dimensions. Applications to environmental samples are shown by direct potentiometry and potentiometric titrations in real water samples. Conducting polymers (CPs) have been used as solid-contact materials and as intermediate layer between the polyvinyl chloride (PVC)-containing ion-selective membrane and the graphite-containing substrate. Different diamides have been incorporated into the PVC membrane. In the range from 10-4 mol/L to 10-1 mol/L, the ISEs show linear slopes of 27 mV/decade, which is close to the Nernstian response. Moreover, the ISEs have response times of 6 months. The novel potentiometric ASS sensors enable simple and exact Ca2+ determinations in real samples. 展开更多
关键词 ALL-SOLID-STATE sensor Ca2+-Selective Electrode potentiometric TITRATION Environmental SAMPLES
下载PDF
Enhanced Electrochemical and Physical Properties of Ag/AgCl Planar Reference Electrodesin Potentiometric Sensors by Graphite Oxide Layer
5
作者 Tung Son Vinh Nguyen Tien Minh Huynh +1 位作者 Tin Chanh Duc Doan Chien Mau Dang 《材料科学与工程(中英文A版)》 2019年第2期83-90,共8页
The most common reference electrode (RE) which is used in electrochemical measurements is the Ag/AgCl electrode. In this study, we present a novel solid-state Ag/AgCl planar electrode that was coated with a thin layer... The most common reference electrode (RE) which is used in electrochemical measurements is the Ag/AgCl electrode. In this study, we present a novel solid-state Ag/AgCl planar electrode that was coated with a thin layer of Graphite Oxide (GO) as a protective layer. The Ag/AgCl planar electrode was fabricated by using the photolithography and lift-off method combined with the Ag[NH3]2Cl complex. The GO was produced by Hummer’s method and was deposited on top of the Ag/AgCl layer by drop-casting method. The layers of the fabricated reference electrode were characterized by micro Raman spectroscopy, Scanning Electron Microscopy (SEM) and Energy-dispersive X-ray spectroscopy (EDX). The responding time of the planar electrode was short and the signal was more stable in comparison to the plainAg/AgCl electrode. The Open Circuit Potential (OCP) measurement with the fabricated electrode as the RE and the platinum electrode as the working electrode in electrolyte solutions which had various pH values was performed with a linear response in pH ranges from pH 5 to pH 8 and the linear correlation coefficient (R^2 = 0.9899). Moreover, the coating of the GO layers also enhanced the durability of the modified electrode. The results showed that the modified Ag/AgCl electrode with a thin layer GO as the protective layer could be used as plana REs for the potentiometric sensors. 展开更多
关键词 GRAPHITE OXIDE potentiometric sensor Ag/AgCl reference ELECTRODE
下载PDF
光寻址电位传感器的自相关检测方法
6
作者 李学亮 刘诗斌 +1 位作者 檀杰 罗杰璋 《传感技术学报》 CAS CSCD 北大核心 2024年第3期404-408,共5页
针对基于光寻址电位传感器的微流控芯片信噪比低的问题,提出了一种基于自相关检测的光寻址电位传感器信号提取方法。采用气液分离的方法在微流路内产生了体积约1μL的样品微滴,对比了光寻址电位传感器在方波激励与正弦波激励下检测微滴... 针对基于光寻址电位传感器的微流控芯片信噪比低的问题,提出了一种基于自相关检测的光寻址电位传感器信号提取方法。采用气液分离的方法在微流路内产生了体积约1μL的样品微滴,对比了光寻址电位传感器在方波激励与正弦波激励下检测微滴的I/V特性曲线,以及在相同条件下的I-f特性曲线。结果表明:采用自相关检测法,光寻址电位传感器具有53.8 mV/pH的灵敏度,其信噪比提高了7.020 6 dB。研究结果对于微型LAPS光电流信号高精度检测做出了有益探索,具有良好的应用前景。 展开更多
关键词 光寻址电位传感器 自相关检测 微流控芯片 微弱信号检测
下载PDF
A Novel Structure of LAPS Array for Cell-Based Biosensor
7
作者 Ying Xu Hua Cai +3 位作者 Qingjun Liu Lifeng Qin Lijiang Wang Ping Wang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期51-54,共4页
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface fo... The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured. 展开更多
关键词 light-addressable potentiometric sensor array LAPS sensitivity cell-based biosensor
下载PDF
基于丝网印刷传感器的重金属现场快速检测仪研制
8
作者 蒋彩云 胡耀娟 +3 位作者 丁爱芳 薛雯蔚 曾嵘斌 陈昌云 《南京师大学报(自然科学版)》 CAS 北大核心 2023年第3期141-148,共8页
基于丝网印刷传感技术研制的现场快速重金属检测仪,采用微分电位溶出的原理,可应用于水样、污泥、食品、农产品中重金属铅的快速检测.该仪器具有体积小、便于携带、检测速度快、灵敏度高、操作简便且耗样量少等优点.对某地污泥中的铅进... 基于丝网印刷传感技术研制的现场快速重金属检测仪,采用微分电位溶出的原理,可应用于水样、污泥、食品、农产品中重金属铅的快速检测.该仪器具有体积小、便于携带、检测速度快、灵敏度高、操作简便且耗样量少等优点.对某地污泥中的铅进行含量测定,结果显示,测定结果的相对标准偏差RSD小于2%,回收率为98.49%~101.58%,具有良好的准确度和精密度.经过样品前处理后,单个样品检测时间约3 min.该仪器在现场痕量重金属检测方面具有良好的应用前景. 展开更多
关键词 重金属离子 微分电位溶出法 丝网印刷传感技术 现场快速检测
下载PDF
Coulometric Response of H-Selective Solid-Contact Ion-Selective Electrodes and Its Application in Flexible Sensors+
9
作者 Tingting Han Tao Song +4 位作者 Shiyu Gan Dongxue Han Johan Bobacka Li Niu Ari lvaska 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2023年第2期207-213,共7页
The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulf... The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection. 展开更多
关键词 solid-contact ion-selective electrodes Membranes Proton transfer Conducting materials Cyclic voltammetry Coulometric response Flexible sensors Electrochemical impedance spectrum
原文传递
A non-labeled DNA biosensor based on light addressable potentiometric sensor modified with TiO_2 thin film 被引量:1
10
作者 Xiao-lin ZONG Chun-sheng WU Xiao-ling WU Yun-feng LU Ping WANG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2009年第11期860-866,共7页
Titanium dioxide (TiO2) thin film was deposited on the surface of the light addressable potentiometric sensor (LAPS) to modify the sensor surface for the non-labeled detection of DNA molecules. To evaluate the effect ... Titanium dioxide (TiO2) thin film was deposited on the surface of the light addressable potentiometric sensor (LAPS) to modify the sensor surface for the non-labeled detection of DNA molecules. To evaluate the effect of ultraviolet (UV) treatment on the silanization level of TiO2 thin film by 3-aminopropyltriethoxysilane (APTS),fluorescein isothiocyanate (FITC) was used to label the amine group on the end of APTS immobilized onto the TiO2 thin film. We found that,with UV irradiation,the silanization level of the irradiated area of the TiO2 film was improved compared with the non-irradiated area under well-controlled conditions. This result indicates that TiO2 can act as a coating material on the biosensor surface to improve the effect and efficiency of the covalent immobilization of biomolecules on the sensor surface. The artificially synthesized probe DNA molecules were covalently linked onto the surface of TiO2 film. The hybridization of probe DNA and target DNA was monitored by the recording of I-V curves that shift along the voltage axis during the process of reaction. A significant LAPS signal can be detected at 10 μmol/L of target DNA sample. 展开更多
关键词 DNA biosensor Titanium dioxide (Ti02) thin film Light addressable potentiometric sensor (LAPS) SILANIZATION Fluorescein label Gene chip
原文传递
Topological Data Analysis of Potentiometric Multisensor Measurements in Treated Wastewater
11
作者 Valeria Belikova Vitaly Panchuk +3 位作者 Evgeny Legin Anastasia Melenteva Andrey Legin Dmitry Kirsanov 《Journal of Analysis and Testing》 EI 2018年第4期291-298,共8页
In this study,a multisensor system consisting of 23 potentiometric sensors was applied for long-term online measurements in outlet flow of the water treatment plant.Within 1 month of continuous measurements,the data s... In this study,a multisensor system consisting of 23 potentiometric sensors was applied for long-term online measurements in outlet flow of the water treatment plant.Within 1 month of continuous measurements,the data set of more than 295,000 observations was acquired.The processing of this dataset with conventional chemometric tools was cumbersome and not very informative.Topological data analysis(TDA)was recently suggested in chemometric literature to deal with large spectroscopic datasets.In this research,we explore the opportunities of TDA with respect to multisensor data with only 23 variables.It is shown that TDA allows for convenient data visualization,studying the evolution of water quality during the measurements and tracking the periodical structure in the data related to the water quality depending on the time of the day and the day of the week.TDA appears to be a valuable tool for multisensor data exploration. 展开更多
关键词 Topological data analysis Multisensor systems potentiometric sensors Water quality
原文传递
Research on the enhancement of signal-to-noise ratio of light-addressable potentiometric sensor by optical focusing
12
作者 陈东 刘诗斌 +1 位作者 殷世民 梁晋涛 《Optoelectronics Letters》 EI 2016年第1期27-30,共4页
For enhancing the response of light-addressable potentiometric sensor(LAPS) and further improving its signal-to-noise ratio(SNR),an optical focusing method is adopted.Experimental research and theoretical analysis rev... For enhancing the response of light-addressable potentiometric sensor(LAPS) and further improving its signal-to-noise ratio(SNR),an optical focusing method is adopted.Experimental research and theoretical analysis reveal that the magnitude of responsive signal is increased by optical focusing,and the SNR is improved remarkably.These research results indicate that the optical focusing is an effective approach for improving SNR of LAPS. 展开更多
关键词 FOCUSING Potentiometers (electric measuring instruments) potentiometric sensors
原文传递
Neurochip based on light-addressable potentiometric sensor with wavelet transform de-noising
13
作者 Qing-jun LIU Wei-wei YE +3 位作者 Hui YU Ning HU Li-ping DU Ping WANG 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2010年第5期323-331,共9页
Neurochip based on light-addressable potentiometric sensor(LAPS),whose sensing elements are excitable cells,can monitor electrophysiological properties of cultured neuron networks with cellular signals well analyzed.H... Neurochip based on light-addressable potentiometric sensor(LAPS),whose sensing elements are excitable cells,can monitor electrophysiological properties of cultured neuron networks with cellular signals well analyzed.Here we report a kind of neurochip with rat pheochromocytoma(PC12) cells hybrid with LAPS and a method of de-noising signals based on wavelet transform.Cells were cultured on LAPS for several days to form networks,and we then used LAPS system to detect the extracellular potentials with signals de-noised according to decomposition in the time-frequency space.The signal was decomposed into various scales,and coefficients were processed based on the properties of each layer.At last,signal was reconstructed based on the new coefficients.The results show that after de-noising,baseline drift is removed and signal-to-noise ratio is increased.It suggests that the neurochip of PC12 cells coupled to LAPS is stable and suitable for long-term and non-invasive measurement of cell electrophysiological properties with wavelet transform,taking advantage of its time-frequency localization analysis to reduce noise. 展开更多
关键词 Neurochip Light-addressable potentiometric sensor(LAPS) Wavelet transform Threshold De-noising
原文传递
汽车尾气用NO_x传感器 被引量:10
14
作者 赵海燕 王岭 +2 位作者 陈嘉庚 吴印林 赵燕琴 《传感器与微系统》 CSCD 北大核心 2007年第1期8-10,14,共4页
汽车尾气中的有害物主要有CO,HC,NOx,SOx以及一些微粒物质,给人类赖以生存的大气环境带来了严重的危害。汽车尾气用NOx传感器开发主要是为了解决NOx(包括NO,NO2)的排放问题,能够实现准确、快速地测定NOx含量,从而满足大气质量检测和环... 汽车尾气中的有害物主要有CO,HC,NOx,SOx以及一些微粒物质,给人类赖以生存的大气环境带来了严重的危害。汽车尾气用NOx传感器开发主要是为了解决NOx(包括NO,NO2)的排放问题,能够实现准确、快速地测定NOx含量,从而满足大气质量检测和环境保护的要求。目前,NOx气体传感器主要有半导体型、电位型和电流型。主要介绍了这3种汽车用NOx传感器的原理、结构及应用,并简要分析了其向微型化、集成化和智能化等方向发展的趋势。 展开更多
关键词 NOX传感器 半导体传感器 电位型传感器 电流型传感器
下载PDF
分子印迹电位型传感器快速检测猪尿液中的克伦特罗 被引量:18
15
作者 梁荣宁 高奇 秦伟 《分析化学》 SCIE EI CAS CSCD 北大核心 2012年第3期354-358,共5页
以盐酸克伦特罗为模板分子,采用沉淀聚合法合成了克伦特罗的分子印迹聚合物,并以其为离子载体,制得分子印迹聚合物膜克伦特罗离子选择性电极。在最优实验条件下,电极对克伦特罗阳离子的检出限可达7.0×10-8mol/L,线性范围为1.0×... 以盐酸克伦特罗为模板分子,采用沉淀聚合法合成了克伦特罗的分子印迹聚合物,并以其为离子载体,制得分子印迹聚合物膜克伦特罗离子选择性电极。在最优实验条件下,电极对克伦特罗阳离子的检出限可达7.0×10-8mol/L,线性范围为1.0×10-7~1.0×10-4mol/L,能斯特斜率为55.7 mV/decade。此电极具有优越的选择性、快速的响应时间以及良好的稳定性;已成功应用于实际猪尿样品中克伦特罗的测定,加标回收率为98%~107%,检测时间小于3 min。 展开更多
关键词 分子印迹聚合物 电位型传感器 克伦特罗
下载PDF
平板式ZrO_2汽车氧传感器的结构、原理及研究进展 被引量:11
16
作者 任继文 张鸿海 +1 位作者 刘胜 王景道 《仪表技术与传感器》 CSCD 北大核心 2007年第4期8-12,14,共6页
庞大的汽车氧传感器市场、严格的汽车尾气排放法规和国内相关技术的欠缺,使得研究和开发具有自主产权的、性能好、可靠性高的氧传感器产品显得尤为迫切和重要。目前,平板式ZrO2汽车氧传感器由于具有尺寸小、响应快、能耗低、易集成、在... 庞大的汽车氧传感器市场、严格的汽车尾气排放法规和国内相关技术的欠缺,使得研究和开发具有自主产权的、性能好、可靠性高的氧传感器产品显得尤为迫切和重要。目前,平板式ZrO2汽车氧传感器由于具有尺寸小、响应快、能耗低、易集成、在恶劣环境下工作稳定等优点,而成为汽车尾气控制的主流氧传感器。介绍了该传感器的结构、原理、国内外发展研究进展及发展趋势。 展开更多
关键词 平板式氧传感器 二氧化锆 浓差型氧传感器 极限电流型氧传感器 双电池宽范围型氧传感器
下载PDF
平板式二氧化锆氧传感器的研究进展 被引量:15
17
作者 罗志安 肖建中 +2 位作者 夏风 梁建超 刘石明 《传感器技术》 CSCD 北大核心 2004年第8期4-8,共5页
由于日益严格的排放法规,平板式二氧化锆氧传感器将成为汽车尾气控制应用的主流传感器。介绍了平板式氧传感器的制备工艺、结构和三种平板式氧传感器的工作原理并进行了对比。最后,展望了平板式氧传感器的发展前景。
关键词 平板式氧传感器 二氧化锆 电势型氧传感器 极限电流型氧传感器 双电池型氧传感器
下载PDF
一种新型生物化学图象传感器的研究 被引量:5
18
作者 李蓉 王平 +4 位作者 张钦涛 李全政 崔大付 韩泾鸿 陈德勇 《中国生物医学工程学报》 EI CAS CSCD 北大核心 2000年第4期382-386,431,共6页
本文介绍了一种新型的光寻址生物和化学图象传感器的基本原理、结构及特点 ,并着重介绍了我们开发研制的生物化学图象传感器和有关的测试实验结果。完成了半导体硅器件的制作、生物化学敏感膜的制备、以激光器为主的光学扫描和机械定位... 本文介绍了一种新型的光寻址生物和化学图象传感器的基本原理、结构及特点 ,并着重介绍了我们开发研制的生物化学图象传感器和有关的测试实验结果。完成了半导体硅器件的制作、生物化学敏感膜的制备、以激光器为主的光学扫描和机械定位系统以及基于微机系统的测量控制系统的设计制作。该传感器可以检测不同的生物和化学物质的静态及动态响应图象。实验结果表明 :该光寻址生物化学传感器系统具有较高灵敏度和分辨率以及较好的光寻址成象能力。利用该传感器可望开发出新一代的集成生物化学图象传感器。 展开更多
关键词 生物传感器 化学传感器 光寻址电位传感器 图象传感器
下载PDF
基于微透镜阵列的多通道光寻址电位传感器研究 被引量:6
19
作者 蔡华 徐莹 +4 位作者 刘清君 李燕 王丽江 王平 杨国光 《传感技术学报》 CAS CSCD 北大核心 2007年第1期58-63,共6页
为了提高化学和生物图像传感器的成像速度和简化成像系统,提出了一种基于微透镜阵列的多通道光寻址电位传感器.利用微透镜阵列把单束激光转化成点阵,通过多频率斩波器,得到不同频率的光点阵列用作光寻址电位传感器的光源,从而实现多点... 为了提高化学和生物图像传感器的成像速度和简化成像系统,提出了一种基于微透镜阵列的多通道光寻址电位传感器.利用微透镜阵列把单束激光转化成点阵,通过多频率斩波器,得到不同频率的光点阵列用作光寻址电位传感器的光源,从而实现多点同时检测.实验结果表明该系统具有良好的频域分辨率,通过数字补偿技术可获得各个检测点的电流电压特性曲线,证明可实现多点同时检测.该系统可以用于光寻址电位传感器和扫描光感阻抗传感器的快速成像,以及多通道化学生物图像检测. 展开更多
关键词 光寻址电位传感器 微透镜阵列 多通道传感器
下载PDF
基于氧硫功能团载体的铅离子电位传感器的研究与进展 被引量:5
20
作者 黄美荣 谷国利 +1 位作者 施凤英 李新贵 《分析化学》 SCIE CAS CSCD 北大核心 2012年第1期50-58,共9页
系统总结归纳了基于氧硫功能团载体的铅离子电位传感器,具体涉及到蒽醌、芳羧酸、羧酸酯、磷酸酯和含酰胺、硫酰胺大环化合物等。蒽醌类载体普遍具有较快的铅离子响应速度,响应时间为2 s。含硫芳香羧酸对铅离子的传感普遍较为敏感,构建... 系统总结归纳了基于氧硫功能团载体的铅离子电位传感器,具体涉及到蒽醌、芳羧酸、羧酸酯、磷酸酯和含酰胺、硫酰胺大环化合物等。蒽醌类载体普遍具有较快的铅离子响应速度,响应时间为2 s。含硫芳香羧酸对铅离子的传感普遍较为敏感,构建不对称膜后,探检出限改善至6.0×10-10mol/L。磷酸酯则具有很强的抗干扰能力,大部分金属离子选择系数logK均小于-3.0。而含酰胺基团的大环化合物载体已构建成微型传感器,从而可探测受限于3μL测量池的样品,检出限达2.7×10-9mol/L。 展开更多
关键词 电位传感器 铅离子传感器 离子载体 蒽醌 芳羧酸 磷酸酯 硫代酰胺 综述
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部