期刊文献+
共找到4,576篇文章
< 1 2 229 >
每页显示 20 50 100
Solid-phase microextraction of endogenous metabolites from intact tissue validated using a Biocrates standard reference method kit 被引量:1
1
作者 Runshan Will Jiang Karol Jaroch Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第1期55-62,共8页
Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the ... Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the endogenous metabolome.In this study,solid-phase microextraction(SPME)fibers were used to monitor changes in endogenous compounds in homogenized and intact ovine lung tissue.Following SPME,a Biocrates AbsoluteIDQ assay was applied to make a downstream targeted metabolomics analysis and confirm the advantages of in vivo SPME metabolomics.The AbsoluteIDQ kit enabled the targeted analysis of over 100 metabolites via solid-liquid extraction and SPME.Statistical analysis revealed significant differences between conventional liquid extractions from homogenized tissue and SPME results for both homogenized and intact tissue samples.In addition,principal component analysis revealed separated clustering among all the three sample groups,indicating changes in the metabolome due to tissue homogenization and the chosen sample preparation method.Furthermore,clear differences in free metabolites were observed when extractions were performed on the intact and homogenized tissue using identical SPME procedures.Specifically,a direct comparison showed that 47 statistically distinct metabolites were detected between the homogenized and intact lung tissue samples(P<0.05)using mixed-mode SPME fibers.These changes were probably due to the disruptive homogenization of the tissue.This study's findings highlight both the importance of sample preparation in tissue-based metabolomics studies and SPME's unique ability to perform minimally invasive extractions without tissue biopsy or homogenization while providing broad metabolite coverage. 展开更多
关键词 solid-phase microextraction Solvent extraction Metabolomics Sample preparation In vivo sampling
下载PDF
Scalable solid-phase synthesis of defect-rich graphene for oxygen reduction electrocatalysis 被引量:1
2
作者 Chunxiao Dong Li Yang +4 位作者 Cheng Lian Xiaoling Yang Yihua Zhu Hongliang Jiang Chunzhong Li 《Green Energy & Environment》 SCIE EI CSCD 2023年第1期224-232,共9页
Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon ... Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon electrocatalysts remains challenging.Herein,a low-cost and simple route is developed to synthesize defective graphene by pyrolyzing the mixture of glucose and carbon nitride.Molecular dynamics simulations reveal that the graphene formation is ascribed to two-dimensional layered feature of carbon nitride,and high compatibility of carbon nitride/glucose systems.Structural measurements suggest that the graphene possesses rich edge and topological defects.The graphene catalyst exhibits higher power density than commercial Pt/C catalyst in a primary Zn-air battery.Combining experimental results and theoretical thermodynamic analysis,it is identified that graphitic nitrogen-modified topological defects at carbon framework edges are responsible for the decent ORR performance.The strategy presented in this work can be can be scaled up readily to fabricate defective carbon materials. 展开更多
关键词 Carbon materials ELECTROCATALYSIS Oxygen reduction reaction solid-phase synthesis Zn-air battery
下载PDF
Carbon Doping Triggered Efficient Electrochemical Hydrogen Evolution of Cross-Linked Porous Ru-MoO_(2) Via Solid-Phase Reaction Strategy 被引量:1
3
作者 Jialin Cai Jianye Yang +7 位作者 Xin Xie Jie Ding Leyan Liu Wanyu Tian Yushan Liu Zhiyong Tang Baozhong Liu Siyu Lu 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第1期392-400,共9页
The defect-free structure of Mo-based materials is a“double-edged sword”,which endows the material with excellent stability,but limits its chemical versatility and application in electrochemical hydrogen evolution r... The defect-free structure of Mo-based materials is a“double-edged sword”,which endows the material with excellent stability,but limits its chemical versatility and application in electrochemical hydrogen evolution reaction(HER).Carbon doping engineering is an attractive strategy to effectively improve the performance of Mo-based catalyst and maintain their stability.Herein,we report a cross-linked porous carbon-doped MoO_(2)(C–MoO_(2))-based catalyst Ru/C–MoO_(2) for electrochemical HER,which is prepared by the convenient redox solid-phase reaction(SPR)of porous RuO_(2)/Mo_(2)C composite precursor.Theoretical studies reveal that due to the presence of carbon atoms,the electronic structure of C–MoO_(2) has been properly adjusted,and the loaded small Ru nanoparticles provide a fast water dissociation rate and moderate H adsorption strength.In electrochemical studies under a pH-universal environment,Ru/C–MoO_(2) electrocatalyst exhibits a low overpotential at a current density of 10 mA cm^(-2) and has a low Tafel slope.Meanwhile,Ru/C-MoO_(2) has excellent stability for more than 100 h at an initial current density of 100 mA cm^(-2). 展开更多
关键词 carbon doped hydrogen evolution reaction macro-meso-micropore MoO_(2) RU solid-phase reaction
下载PDF
Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma
4
作者 Wei Zhou Martyna N.Wieczorek +1 位作者 Runshan Will Jiang Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第2期216-222,共7页
The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as b... The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R^(2)of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%. 展开更多
关键词 solid-phase microextraction Mass spectrometry Microfluidic open interface Coated blade spray Probe electrospray ionization Drug of abuse
下载PDF
Chemiluminescence Determination of Benzoic Acid Using A Solid-Phase Verdigris Reactor 被引量:1
5
作者 王晓妮 张洁 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第3期283-286,共4页
A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that t... A new chemiluminescence flow system has been developed for sequential determina-tion of benzoic acid based on the reaction of the compound with copper carbonate entrapped in a solid-phase reactor. It was found that the unsaturated complex of Cu(II) and benzoic acid (1:1) has strong catalytic effect on the luminol-H2O2 chemiluminescence reaction. The calibration graph is linear over the range of 0.025 ~ 60 g/mL of benzoic acid, with a relative standard deviation of less than 3.0 %, and the detection limit is 0.01礸穖L-1. The proposed method was applied to the determination of benzoic acid content in different pharmaceutical formulations. 展开更多
关键词 Benzoic acid CHEMILUMINESCENCE solid-phase reactor pharmaceutical formulations.
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
6
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
Use of packed-fiber solid-phase extraction for sample clean-up and preconcentration of vitamin B_(12) before determination 被引量:5
7
作者 Fang Fang Xue Jun Kang Zhi Yong Liu Yu Qin Ma Zhong Ze GU 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第12期1491-1494,共4页
A rapid and simple preconcentration step applying packed-fiber solid-phase extraction columns has been investigated to vitamin B12. The extraction performance of the new method was investigated preliminarily on vitami... A rapid and simple preconcentration step applying packed-fiber solid-phase extraction columns has been investigated to vitamin B12. The extraction performance of the new method was investigated preliminarily on vitamin functional drink. The analysis used a reversed-phase C18 column, with a photo-diode array detector at 220 nm. The samples were preconcentrated with packed-fiber solid-phase extraction columns. Good linearity was observed in vitamin functional drink. The repeatability of extraction performance, expressed as relative standard deviations, was from 3.5% to 4.3%. The limit of detection (LOD) is 5 ng mL^-1 (S/N = 3). Finally, the method had been applied for the determination of vitamin B12 in vitamin functional drink. 展开更多
关键词 Vitamin B12 NANOFIBERS Packed-fiber solid-phase extraction PRECONCENTRATION
下载PDF
Synthesis of a highly hydrophobic cyclic decapeptide by solid-phase synthesis of linear peptide and cyclization in solution 被引量:5
8
作者 Chen, Jian Zhang, Bei +2 位作者 Xie, Cao Lu, Yi Wu, Wei 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第4期391-394,共4页
A general method was described to synthesize a highly hydrophobic cyclic peptide,cyclo[LWLWLWLWLQ]where underlines indicate D-configuration of the amino acid,by a two-step solid-phase/solution synthesis strategy.The l... A general method was described to synthesize a highly hydrophobic cyclic peptide,cyclo[LWLWLWLWLQ]where underlines indicate D-configuration of the amino acid,by a two-step solid-phase/solution synthesis strategy.The linear decapeptide was assembled by standard Boc chemistry on solid-phase and subsequently cyclized in solution with high efficiency and reproducibility. In subsequent purification by semi-preparative HPLC,50%(v/v) DMF/H_2O was employed as the solvent to overcome the difficulty of solubilization... 展开更多
关键词 Cyclic peptide Decapeptide cyclo[LWLWLWLWLQ] solid-phase synthesis CYCLIZATION PURIFICATION
下载PDF
Solid-phase synthesis of Cu2MoS4 nanoparticles for degradation of methyl blue under a halogen-tungsten lamp 被引量:4
9
作者 Shi-na Li Rui-xin Ma Cheng-yan Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2018年第3期310-314,共5页
The Cu_2MoS_4 nanoparticles were prepared using a relatively simple and convenient solid-phase process, which was applied for the first time. The crystalline structure, morphology, and optical properties of Cu_2MoS_4 ... The Cu_2MoS_4 nanoparticles were prepared using a relatively simple and convenient solid-phase process, which was applied for the first time. The crystalline structure, morphology, and optical properties of Cu_2MoS_4 nanoparticles were characterized using X-ray diffraction, X-ray photoelectron spectroscopy, field emission scanning electron microscopy, and UV-vis spectrophotometry. Cu_2MoS_4 nanoparticles having a band gap of 1.66 eV exhibits good photocatalytic activity in the degradation of methylene blue, which indicates that this simple process may be critical to facilitate the cheap production of photocatalysts. 展开更多
关键词 Cu2MoS4 NANOPARTICLES solid-phase synthesis DEGRADATION PHOTOCATALYST METHYL blue
下载PDF
Fast determination of multi-mycotoxins in corn by dispersive solid-phase extraction coupled with ultra-performance liquid chromatography with tandem quadrupole time-of-flight mass spectrometry 被引量:2
10
作者 WANG Yan DONG Yan-jie +5 位作者 LI Zeng-mei DENG Li-gang GUO Chang-ying ZHANG Shu-qiu LI Da-peng ZHAO Shan-cang 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2016年第7期1656-1666,共11页
A fast analytical method for the simultaneous determination of 9 mycotoxins, including alfatoxins (B1, B2, G1, and G2), fumonisins (B1, B2 and B3), zearalenone, and deoxynivalenol in corn using dispersive solid-ph... A fast analytical method for the simultaneous determination of 9 mycotoxins, including alfatoxins (B1, B2, G1, and G2), fumonisins (B1, B2 and B3), zearalenone, and deoxynivalenol in corn using dispersive solid-phase extraction method and ultra-performance liquid chromatography coupled to tandem quadrupole time-of-lfight mass spectrometry (UPLC-Q-TOF-MS) was developed and validated. Samples were extracted with acetonitrile-water (84:16, v:v, containing 1% acetic acid) using ultrasonic extraction. The extracts were puriifed with a dispersive SPE method using C18 as a cleaning agent. The ifnal clear extracts were dried by nitrogen blowing and subsequently redissolved in methanol-water (5:5, v:v). The samples were then analyzed by UPLC-Q-TOF-MS with 0.1% formic acid in ammonium acetate-methanol as mobile phase. The mean recoveries were ranged from 68.0 to 120.0%, and the relative standard deviation (RSD) ranged from 0.18 to 6.29%. Limits of detections ranged from 0.05 to 50 μg kg?1, and limits of quantiifcation ranged from 0.1 to 200 μg kg?1, which were below the legal limits set by the European Union for the legislated mycotoxins. The developed method was applied to 130 corn samples. Among the mycotoxins studied, alfatoxins B1 and fumonisins B1, B2 and B3 were the most predominant mycotoxins, and their concentrations were 0–593.12, 0–2.01×104, 0–6.94×103 and 0–3.05×103 μg kg–1, respectively. 展开更多
关键词 C18 CORN mycotoxins dispersive solid-phase extraction
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
11
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase MICROEXTRACTION Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Solid-phase extraction of trace Au(Ⅲ) with SDG and determination by the catalytic spectrophotometric method 被引量:2
12
作者 LI Huizhi ZHAI Yubo 《Rare Metals》 SCIE EI CAS CSCD 2008年第6期560-565,共6页
The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ... The new catalytic kinetic spectrophotometric method for Au(III) determination was developed and validated. It was based on the catalytic effect of gold on the oxidation of sudan red III by ammonium peroxodisulfate ((NH4)2S2O8) with nitrilo triacetic acid as an activator in microemulsion and H2SO4 medium. Under optimum conditions, there was the linearity of the calibration curve in the concentration range from 0 to 20 μg/L Au(Ⅲ) at 520 nm. The relative standard deviation was 3.0% with a correlation coefficient of 0.9986. The detection limit achieved was 9.75 × 10^-5 μg/mL. A new method using a column packed with sulfhydryl dextrose gel (SDG) as a solid-phase extractant has been developed for the preconcentration and separation of Au(Ⅲ) ions. The method has been applied to the determination of trace gold with satisfactory results. 展开更多
关键词 analytical chemistry catalytic kinetic spectrophotometric method solid-phase extraction gold(Ⅲ)
下载PDF
Multiresidue Method for Determination of 67 Pesticides in Water Samples Using Solid-Phase Extraction with Centrifugation and Gas Chromatography-Mass Spectrometry 被引量:3
13
作者 Abir Kouzayha Abdul Rahman Rabaa +3 位作者 Mohamad Al Iskandarani Daniel Beh Hélène Budzinski Farouk Jaber 《American Journal of Analytical Chemistry》 2012年第3期257-265,共9页
A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 a... A new multi-residue method based on solid-phase extraction (SPE) with centrifugation was developed for determination and quantitation of 67 pesticides in water samples. Two SPE cartridges were tested: Chromabond C18 and Oasis HLB. Parameters that influence the extraction efficiency such as the eluent volume, the sample loading volume, the addition of organic solvent to water sample, sorbent drying and elute concentration were optimized. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 2 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under the optimized conditions, this method showed good recoveries higher than 65% - 68% for the 67 analyzed pesticides using the C18 and HLB cartridges with relative standard deviations lower than 9.7% - 12.3%. Limits of quantification were between 2 and 20 ng.L–1. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples. 展开更多
关键词 MULTI-RESIDUE PESTICIDES solid-phase Extraction CENTRIFUGATION Gas Chromatography-Mass SPECTROMETRY
下载PDF
Time-frequency analysis of Li solid-phase diffusion in spherical active particles under typical discharge modes 被引量:2
14
作者 Qiu-An Huang Yuxuan Bai +5 位作者 Liang Wang Juan Wang Fangzhou Zhang Linlin Wang Xifei Li Jiujun Zhang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第4期209-224,共16页
Li transient concentration distribution in spherical active material particles can affect the maximum power density and the safe operating regime of the electric vehicles(EVs). On one hand, the quasiexact/exact soluti... Li transient concentration distribution in spherical active material particles can affect the maximum power density and the safe operating regime of the electric vehicles(EVs). On one hand, the quasiexact/exact solution obtained in the time/frequency domain is time-consuming and just as a reference value for approximate solutions;on the other hand, calculation errors and application range of approximate solutions not only rely on approximate algorithms but also on discharge modes. For the purpose to track the transient dynamics for Li solid-phase diffusion in spherical active particles with a tolerable error range and for a wide applicable range, it is necessary to choose optimal approximate algorithms in terms of discharge modes and the nature of active material particles. In this study, approximation methods,such as diffusion length method, polynomial profile approximation method, Padé approximation method,pseudo steady state method, eigenfunction-based Galerkin collocation method, and separation of variables method for solving Li solid-phase diffusion in spherical active particles are compared from calculation fundamentals to algorithm implementation. Furthermore, these approximate solutions are quantitatively compared to the quasi-exact/exact solution in the time/frequency domain under typical discharge modes, i.e., start-up, slow-down, and speed-up. The results obtained from the viewpoint of time-frequency analysis offer a theoretical foundation on how to track Li transient concentration profile in spherical active particles with a high precision and for a wide application range. In turn, optimal solutions of Li solid diffusion equations for spherical active particles can improve the reliability in predicting safe operating regime and estimating maximum power for automotive batteries. 展开更多
关键词 Li solid-phase diffusion Discharge mode Approximate algorithm Quasi-exact/exact solution Time-frequency analysis
下载PDF
Determination of Trace Amount of Yttrium with Bromopyrogallol Red by solid-phase Spectrophotometry 被引量:1
15
作者 Jinzhang Gao,Gang Ni, Li Yuan, Jingwan Kang Department of Chemistry, Northwest Normal University, Lanzhou 730070, China 《Rare Metals》 SCIE EI CAS CSCD 2001年第3期202-204,共3页
A simple and sensitive method for the determination of trace amount of yttrium by solid-phase spectrophotometry has been studied. Yttrium can form a 1 : 1 complex with bromopyrogallol red (BPR) on resin, which was det... A simple and sensitive method for the determination of trace amount of yttrium by solid-phase spectrophotometry has been studied. Yttrium can form a 1 : 1 complex with bromopyrogallol red (BPR) on resin, which was determined directly at 605 nm, pH=6.5. It has a highly sensitivity (epsilon = 6.3 x 10(6)) which is 300-fold higher than the corresponding spectrophotometry in solution. The method was applied to the determination of yttrium in churchite. 展开更多
关键词 solid-phase spectrophotometry bromopyrogallol red (BPR) YTTRIUM
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
16
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Solid-phase Synthesis of Acyl-plasminogen-Streptokinase Activator Composite(APSAC) and Its Thrombolytic Properties 被引量:1
17
作者 TENGLi-rong LIANGFang +4 位作者 SUNHong QINYi HONGShui-sheng CHENJia LIULan-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2004年第5期584-587,共4页
The dialysis method has been traditionally used for the conversion of native human plasminogen(Glu-Hpg) to lys-plasminogen(Lys-Hpg). Here is described a solid-phase synthesis method for the preparation of an acyl-plas... The dialysis method has been traditionally used for the conversion of native human plasminogen(Glu-Hpg) to lys-plasminogen(Lys-Hpg). Here is described a solid-phase synthesis method for the preparation of an acyl-plasminogen-streptokinase activator complex(APSAC) from Lys-Hpg, streptokinase(SK) and chemical modification (agent(4-amidinophenyl-4′-aminobenzoate hydrochloride)) with the L-lysine-Sepharose 4B Column as the carrier. The new method significantly increases the product yield and purity over the liquid-phase methods. The APSAC prepared with the new method exhibits a significant thrombolytic effect with a long half-life of about 8.8 h in rabbits. 展开更多
关键词 Acyl-plasminogen-streptokinase activator complex(APSAC) solid-phase synthesis THROMBOLYTIC
下载PDF
Separation and Enrichment of Melamine in Feed by a New Molecularly Imprinted Solid-phase Extraction Column 被引量:1
18
作者 Huang Huabin Zhuang Zhixia +2 位作者 Zhou Yanli Zhao Li Wang Xiaoru 《Animal Husbandry and Feed Science》 CAS 2014年第1期10-13,共4页
[ Objective] The research aimed to develop a new molecular imprinting solid-phase extraction column for the separation and enrichment of melamine in feed. [ Method] The molecular imprinting polymer of melamine was pre... [ Objective] The research aimed to develop a new molecular imprinting solid-phase extraction column for the separation and enrichment of melamine in feed. [ Method] The molecular imprinting polymer of melamine was prepared by mass polymerization method. This polymer was used as filler to prepare molecular imprinting polymer solid-phase extraction(MIP-SPE) column of melamine. The solid-phase extraction conditions were optimized and melamine content in concentrated solution was determined by using HPLC. [ Result] Melamine eould be separated selectively from feed and enriehed by self-made MIP-SPE column. It could wipe off complex matrix from feed and the addition recovery rate was 95%. The contrast experiment between MIP-SPE column and NMIP-SPE ( non-imprinted polymer- solid phase extraction) column showed that the extraction efficiency of the former was obviously higher than the latter. [ Conclusion] The home-made MIP- SPE column could be used to separate and enrich melamine in feed efficiently, with a broad application prospect. 展开更多
关键词 Molecular imprinting solid-phase extraction FEED MELAMINE
下载PDF
Solid-phase Synthesis of PNA Monomer by Ugi Four-component Condensation Reaction 被引量:2
19
作者 WenHaoWANG XiaoMinZOU XinZHANG YiQiuFU PingXU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期585-588,共4页
关键词 Peptide nucleic acids (PNA) Ugi four-component condensation reaction (U-4CR) solid-phase synthesis Isocyanide.
下载PDF
Covalent organic nanospheres as a fiber coating for solid-phase microextraction of genotoxic impurities followed by analysis using GC-MS 被引量:1
20
作者 Yanfang Zhao Jingkun Li +2 位作者 Hanyi Xie Huijuan Li Xiangfeng Chen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第4期583-589,共7页
Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at... Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at 25℃.The obtained nanospheres exhibited a high specific surface area,good thermostability,high acid and alkali resistance,and favorable crystallinity and porosity.Two types of GTIs,alkyl halides(1-iodooctane,1-chlorobenzene,1-bromododecane,1,2-dichlorobenzene,1-bromooctane,1-chlorohexane,and 1,8-dibromooctane)and sulfonate esters(methyl p-toluenesulfonate and ethyl ptoluenesulfonate),were chosen as target molecules for assessing the performance of the coating.The prepared coating achieved high enhancement factors(5097-9799)for the selected GTIs.The strong affinity between CONs and GTIs was tentatively attributed to π-π and hydrophobicity interactions,large surface area of the CONs,and size-matching of the materials.Combined with gas chromatography-mass spectrometry(GC-MS),the established analytical method detected the GTIs in capecitabine and imatinib mesylate samples over a wide linear range(0.2-200 ng/g)with a low detection limit(0.04-2.0 ng/g),satisfactory recovery(80.03%-109.5%),and high repeatability(6.20%-14.8%)and reproducibility(6.20%-14.1%).Therefore,the CON-coated fibers are promising alternatives for the sensitive detection of GTIs in AI samples. 展开更多
关键词 Covalent organic nanospheres solid-phase microextraction Genotoxic impurities Gas chromatography-mass spectrometry
下载PDF
上一页 1 2 229 下一页 到第