期刊文献+
共找到3,892篇文章
< 1 2 195 >
每页显示 20 50 100
Solid-phase microextraction of endogenous metabolites from intact tissue validated using a Biocrates standard reference method kit 被引量:1
1
作者 Runshan Will Jiang Karol Jaroch Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第1期55-62,共8页
Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the ... Improved analytical methods for the metabolomic profiling of tissue samples are constantly needed.Currently,conventional sample preparation methods often involve tissue biopsy and/or homogenization,which disrupts the endogenous metabolome.In this study,solid-phase microextraction(SPME)fibers were used to monitor changes in endogenous compounds in homogenized and intact ovine lung tissue.Following SPME,a Biocrates AbsoluteIDQ assay was applied to make a downstream targeted metabolomics analysis and confirm the advantages of in vivo SPME metabolomics.The AbsoluteIDQ kit enabled the targeted analysis of over 100 metabolites via solid-liquid extraction and SPME.Statistical analysis revealed significant differences between conventional liquid extractions from homogenized tissue and SPME results for both homogenized and intact tissue samples.In addition,principal component analysis revealed separated clustering among all the three sample groups,indicating changes in the metabolome due to tissue homogenization and the chosen sample preparation method.Furthermore,clear differences in free metabolites were observed when extractions were performed on the intact and homogenized tissue using identical SPME procedures.Specifically,a direct comparison showed that 47 statistically distinct metabolites were detected between the homogenized and intact lung tissue samples(P<0.05)using mixed-mode SPME fibers.These changes were probably due to the disruptive homogenization of the tissue.This study's findings highlight both the importance of sample preparation in tissue-based metabolomics studies and SPME's unique ability to perform minimally invasive extractions without tissue biopsy or homogenization while providing broad metabolite coverage. 展开更多
关键词 solid-phase microextraction Solvent extraction Metabolomics Sample preparation In vivo sampling
下载PDF
Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma
2
作者 Wei Zhou Martyna N.Wieczorek +1 位作者 Runshan Will Jiang Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第2期216-222,共7页
The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as b... The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R^(2)of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%. 展开更多
关键词 solid-phase microextraction Mass spectrometry Microfluidic open interface Coated blade spray Probe electrospray ionization Drug of abuse
下载PDF
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
3
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
下载PDF
Flash Evaporation and Headspace Solid-phase Microextraction for the Analysis of the Essential Oils in Traditional Chinese Medicine,Houttuynia Cordata Thunb 被引量:1
4
作者 MinMinLIANG MeiLingQI RuoNongFU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第5期659-662,共4页
关键词 Headspace solid-phase microextraction flash evaporation essential oils GC-MS.
下载PDF
Covalent organic nanospheres as a fiber coating for solid-phase microextraction of genotoxic impurities followed by analysis using GC-MS 被引量:1
5
作者 Yanfang Zhao Jingkun Li +2 位作者 Hanyi Xie Huijuan Li Xiangfeng Chen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第4期583-589,共7页
Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at... Covalent organic nanospheres(CONs)were explored as a fiber coating for solid-phase microextraction of genotoxic impurities(GTIs)from active ingredients(AIs).CONs were synthesized by an easy solutionphase procedure at 25℃.The obtained nanospheres exhibited a high specific surface area,good thermostability,high acid and alkali resistance,and favorable crystallinity and porosity.Two types of GTIs,alkyl halides(1-iodooctane,1-chlorobenzene,1-bromododecane,1,2-dichlorobenzene,1-bromooctane,1-chlorohexane,and 1,8-dibromooctane)and sulfonate esters(methyl p-toluenesulfonate and ethyl ptoluenesulfonate),were chosen as target molecules for assessing the performance of the coating.The prepared coating achieved high enhancement factors(5097-9799)for the selected GTIs.The strong affinity between CONs and GTIs was tentatively attributed to π-π and hydrophobicity interactions,large surface area of the CONs,and size-matching of the materials.Combined with gas chromatography-mass spectrometry(GC-MS),the established analytical method detected the GTIs in capecitabine and imatinib mesylate samples over a wide linear range(0.2-200 ng/g)with a low detection limit(0.04-2.0 ng/g),satisfactory recovery(80.03%-109.5%),and high repeatability(6.20%-14.8%)and reproducibility(6.20%-14.1%).Therefore,the CON-coated fibers are promising alternatives for the sensitive detection of GTIs in AI samples. 展开更多
关键词 Covalent organic nanospheres solid-phase microextraction Genotoxic impurities Gas chromatography-mass spectrometry
下载PDF
Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches
6
作者 Karol Jaroch Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2022年第1期186-191,共6页
The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition.Herein,a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ion... The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition.Herein,a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ionization(coated-PESI)and coated blade spray(CBS)as ambient mass spectrometry approaches for monitoring drug biotransformation.The ability of these methods was investigated for monitoring the dephosphorylation of a prodrug,combretastatin A4 phosphate(CA4P),into its active form,combretastatin A4(CA4),in a cell culture medium supplemented with fetal bovine serum.The CBS spot analysis was modified to achieve the same extraction efficiency as protein precipitation and obtained results in 7 min.Because coated-PESI performs extraction without consuming any samples,it is the preferred technique in the case of a limited sample volume.Although coated-PESI only extracts small quantities of analytes,it uses the desorption solvent volume of 5-10 pL,resulting in high sensitivity,thus allowing the detection of compounds after only 1 min of extraction.The biotransformation of CA4P into CA4 via phosphatases occurs within the simple matrix,and the proposed sample preparation techniques are suitable for monitoring the biotransformation. 展开更多
关键词 solid-phase microextraction Coated probe electrospray ionization Coated blade spray COMBRETASTATIN BIOTRANSFORMATION Prodrug activation
下载PDF
Solid-phase Microextraction with Benzoxy-calix[6]arene Fiber Coupled to Gas Chromatography for the Analysis of Polycyclic Aromatic Hydrocarbons in Water
7
作者 YE Chang-wen ZHANG Xue-na HUANG Jiang-yan LI Xiu-juan PAN Si-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第2期198-202,共5页
Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seve... Headspace solid-phase microextraction(HS-SPME) with sol-gel calix[6]arene-containing fiber followed by gas chromatography with a flame ionization detector was used to examine the composition and distribution of seven polycyclic aromatic hydrocarbons(PAHs) in water. The novel SPME fiber exhibited higher extraction efficiency to PAHs compared with poly(dimethylsiloxane) and other calixarene-containing fibers. Extraction/retention mechanism based on the interactions between calixarenes and PAHs was discussed. Owing to the good selectivity and high extraction capability of this calixarene fiber, low detection limits were obtained in a range of 0.34―6.50 ng/L and the relative standard deviation values were ≤12.3% for all of the analytes. The linear ranges of the proposed method were five orders of magnitude for the tested compounds, with linear correlation coefficients(r) greater than 0.998. The method was applied to the determination of polycyclic aromatic hydrocarbons in nine water sources in Wuhan City, China. Standard addition method was selected for the quantification and the recovery values were in a satisfactory range. Total PAHs concentrations in the nine surface water samples were found to vary between undetectable and 8.840 μg/L with two- and three-ring PAHs predominating. 展开更多
关键词 Polycyclic aromatic hydrocarbon solid-phase microextraction CALIXARENE Gas chromatography WATER
下载PDF
Application of Phenyl Bonded Mesoporous Silica as A Novel Coating Layer of Solid-phase Microextraction for Determination of Benzo[a]pyrene in Water Samples
8
作者 XinZhenDU YaRongWANG QianMA XueFengMAO JinGuoHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第6期801-804,共4页
关键词 Mesoporous silica solid-phase microextraction HPLC benzo[a]pyrene.
下载PDF
Preparation of A New Fiber by Sol-gel Technology in Solid-phase Microextraction (SPME)
9
作者 LiMingWEI QingYuOU JuBaiLI 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第9期1127-1130,共4页
The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-pol... The sol-gel technology is applied for the preparation of solid-phase microextraction (SPME) fiber. The fiber demonstrates high thermal stability, efficient extraction rate and the selectivity for non-polar or low-polar analytes. Efficient SPME-GC-FID analyses of benzene- toluene-ethylbenzene-xylenes (BTEXs) and low-polar halocarbon were achieved by the sol-gel coated DSDA-DDBT-TiO2 fiber. Some parameters of the SPME fiber for the determination of halocarbon in aqueous sample were investigated. 展开更多
关键词 solid-phase microextraction sol-gel technology SELECTIVITY polyimide (DSDA-DDBT).
下载PDF
Sol-Gel-Coated Calix[4]arene Fiber for Solid-Phase Microextraction
10
作者 LiXiu-juan XiaoRui-min +1 位作者 LiHai-bing ZengZhao-rui 《Wuhan University Journal of Natural Sciences》 CAS 2003年第04A期1153-1155,共3页
5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The pr... 5, 11, 17, 23-tetra-tert-butyl-25, 27-diethoxy-26, 28-dihydroxycalix \ arene /hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction with sol-gel technology. The properties of the new coating were investigated by analysis of benzene derivatives, polycyclic aromatic hydrocarbons and aromatic amines. The fiber is characterized by good sensitivity and selectivity to these aromatics. The fiber has stable performance at a high temperature of 380℃ and after a long solvent immersing, thus its lifetime is very long. It shows good fiber-to-fiber and batch-to-batch reproducibility. Furthermore, broad linear ranges and low detection limits are also its characteristics. 展开更多
关键词 solid-phase microextraction SOL-GEL CALIXARENE aromatic compounds
下载PDF
Determination of Aroma Composition of Santalum album Linn by Solid-phase Microextraction-Gas Chromatography-Mass Spectrometry
11
作者 Guotong CHEN Meiqin LI +2 位作者 Chao HUANG Na WEN Aixia WANG 《Asian Agricultural Research》 2020年第9期43-45,共3页
[Objectives]This study aimed to determine the volatile components in Santalum album Linn and gradually clarify the aroma composition of S.album Linn.[Methods]Solid-phase microextraction method was used to obtain the v... [Objectives]This study aimed to determine the volatile components in Santalum album Linn and gradually clarify the aroma composition of S.album Linn.[Methods]Solid-phase microextraction method was used to obtain the volatile components of S.album Linn.The aroma components were analyzed by gas chromatography-mass spectrometry and their relative contents were calculated using the area normalization method.[Results]In a dry state at room temperature,39 chemical components were identified from S.album Linn,mainly olefins(91.15%),alkanes(3.00%),alcohols(2.56%),esters(2.19%),ketones(0.55%),aldehydes(0.41%)and heterocyclics(0.14%).[Conclusions]This method has the advantages of low sample consumption,easy operation,rapid identification of aroma components and high sensitivity,and can effectively separate and determine volatile components in S.album Linn,realizing the rapid identification of different S.album Linn varieties and providing technical support for further research on Chinese medicinal materials. 展开更多
关键词 Santalum album Linn solid-phase microextraction(SPME) Gas chromatography-mass spectrometry Aroma component
下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:2
12
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 solid-phase microextraction Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
下载PDF
Determination of Trihalomethanes in Water Samples Using Headspace Solid-Phase Microextraction Gas Chromatography
13
作者 Nitaya Saesim Wanna Kanchanamayoon 《Journal of Chemistry and Chemical Engineering》 2010年第6期1-7,共7页
关键词 顶空固相微萃取 水样测定 三卤甲烷 气相色谱法 氯化过程 搅拌速度 提取时间 解吸时间
下载PDF
Solid-phase microextraction for flavor analysis in Harari Khat (Catha edulis) stimulant
14
作者 AL-FLAHIAbdulsalam 邹建凯 殷学锋 《Journal of Zhejiang University Science》 EI CSCD 2004年第4期428-431,共4页
This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal com... This research examined the typical flavor compounds in the commonest type of Khat called Harari Khat grown in the region of Ethiopia.Twenty-eight compounds, which includes 1,2-Propanedione,1-Phenyl,Hexanol,Hexanal compounds,Limonene, Benzaldehyde with other flavors, were extracted by polydimethylsiloxane at room temperature for 30min from Khat samples,and identified by solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS).This method needs no organic solvents and required minimal sample. 展开更多
关键词 固相微萃取 阿拉伯茶 哈拉尔族人 口味分析
下载PDF
Determination of amphetamines,ketamine and their metabolites in hair with high-speed grinding and solid-phase microextraction followed by LC-MS 被引量:2
15
作者 Liang Meng Yong Dai +1 位作者 Chen Chen Jun Zhang 《Forensic Sciences Research》 CSCD 2021年第4期273-280,共8页
A novel hair sample pre-treatment method based on high-speed grinding and solid-phase microextraction(SPME)had been applied for the determination of amphetamines,ketamine and their metabolites in hair samples by liqui... A novel hair sample pre-treatment method based on high-speed grinding and solid-phase microextraction(SPME)had been applied for the determination of amphetamines,ketamine and their metabolites in hair samples by liquid chromatography mass spectrometry(LC-MS).A 20mg sample of hair was ground with 2 mL of saturated sodium carbonate solution using a high-efficiency hair grinder with 70 Hz osillation for 2min at 4℃.After centrifuging,1.5mL of the supernatant was transferred and treated with SPME by direct immersion(DI-SPME).The target analytes extracted by fibre were desorbed and analysed using LC-MS.Under the optimum conditions,a recovery of 90.2%-95.8%was obtained for all analytes.The analytical method was linear for all analytes in the range from 0.2 to 10 ng/mg with the correlation coefficient ranging from 0.9985 to 0.9993.The detection limits for all analytes were estimated to be 0.067 ng/mg.The accuracy(mean relative error)was within±6.9%and the precision(relative standard error)was less than 6.8%.The combination of high-speed grinding of hair and SPME had the advantages of being easy to perform,environment-friendly and high in detection sensitivity.The proposed method offered an altermative ana lytical approach for the sensitive detection of drugs in hair samples for forensic purposes. 展开更多
关键词 Forensic sciences forensic toxicology drugs of abuse high-speed grinding hair analysis liquid chromatography-mass spectrometry solid-phase microextraction
原文传递
Analysis of nitrobenzene compounds in water and soil samples by graphene composite-based solid-phase microextraction coupled with gas chromatography–mass spectrometry 被引量:5
16
作者 Gui-Jiang Zhang Xin Zhou +3 位作者 Xiao-Huan Zang Zhi Li Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第11期1449-1454,共6页
In this work, solid-phase microextraction coupled with gas chromatography–mass spectrometry was developed to determine trace levels of nitrobenzene compounds in water and soil samples. Graphene was chosen as the extr... In this work, solid-phase microextraction coupled with gas chromatography–mass spectrometry was developed to determine trace levels of nitrobenzene compounds in water and soil samples. Graphene was chosen as the extraction material and its composite was coated on a stainless steel wire through sol–gel technique for the solid phase microextraction. The key parameters influencing the extraction efficiency were optimized. Under the optimal conditions, the linearity for the compounds was observed in the range of 0.02–15.0 mg/L for water samples, and 0.2–60.0 mg/kg for soil samples, with the correlation coefficients(r) of 0.9966–0.9987. The limits of detection of the method were 0.0025–0.005 mg/L for water samples, and 0.02–0.04 mg/kg for soil samples. The recoveries for the spiked samples were in the range of 72.0%–113.2%, and the precision, expressed as the relative standard deviations, was less than 12.1%. 展开更多
关键词 Graphene solid-phase microextraction Nitrobenzene compounds Gas chromatography–mass spectrometry
原文传递
Facile fabrication of novel cobalt-based carbonaceous coatings on nickel-titanium alloy fiber substrate for selective solid-phase microextraction
17
作者 Junliang Du Rong Zhang +3 位作者 Feifei Wang Hua Zhou Xuemei Wang Xinzhen Du 《Chinese Chemical Letters》 SCIE CAS CSCD 2022年第6期3119-3122,共4页
Fabrication of selective adsorption coatings plays a crucial role in solid-phase microextraction(SPME).Herein,new strategies were developed for the in-situ fabrication of novel cobalt-based carbonaceous coatings on th... Fabrication of selective adsorption coatings plays a crucial role in solid-phase microextraction(SPME).Herein,new strategies were developed for the in-situ fabrication of novel cobalt-based carbonaceous coatings on the nickel-titanium alloy(Ni Ti)fiber substrate using ZIF-67 as a precursor and template through the chemical reaction of ZIF-67 with glucose,dopamine(DA)and melamine,respectively.The adsorption performance of the resulting coatings was evaluated using representative aromatic compounds coupled to high-performance liquid chromatography(HPLC)with ultraviolet detection(HPLC-UV).The results clearly demonstrated that the adsorption selectivity was subject to the surface elemental composition of the fiber coatings.The cobalt and nitrogen co-doped carbonaceous coating showed better adsorption selectivity for ultraviolet filters.In contrast,the cobalt-doped carbonaceous coating exhibited higher adsorption selectivity for polycyclic aromatic hydrocarbons.The fabricated fibers present higher mechanical stability and higher adsorption capability for model analytes than the commercial polydimethylsiloxane and polyacrylate fibers.These new strategies will continue to expand the Ni Ti fibers as versatile fiber substrates for metal-organic frameworks(MOFs)-derived coating materials with controllable nanostructures and tunable properties. 展开更多
关键词 ZIF-67 Cobalt-based carbonaceous coatings Nickel/titanium alloy solid-phase microextraction
原文传递
Determination of trace PAHs in seawater and sediment pore-water by solid-phase microextraction (SPME) coupled with GC/MS 被引量:6
18
作者 Lee Franck Sen-Chun 《Science China Chemistry》 SCIE EI CAS 2006年第6期481-491,共11页
A fast and reliable method for the determination of trace PAHs (polynuclear aromatic hydrocarbons) in seawater by solid-phase microextraction (SPME) followed by gas chromatographic (GC) analysis has been developed. Th... A fast and reliable method for the determination of trace PAHs (polynuclear aromatic hydrocarbons) in seawater by solid-phase microextraction (SPME) followed by gas chromatographic (GC) analysis has been developed. The SPME operational parameters have been optimized, and the effects of salinity and dissolved organic matter (DOM) on PAHs recoveries have been investigated. SPME measures only the portion of PAHs which are water soluble, and can be used to quantify PAH partition coefficient between water and DOM phases. The detection limits of the overall method for the measurement of sixteen PAHs range from 0.1 to 3.5 ng/g, and the precisions of individual PAH measurements range from 4% to 23% RSD. The average recovery for PAHs is 88.2±20.4%. The method has been applied to the determination of PAHs in seawater and sediment porewater samples collected in Jiaozhou Bay and Laizhou Bay in Shandong Peninsula, China. The overall levels of PAHs in these samples reflect moderate pollution compared to seawater samples reported elsewhere. The PAH distribution pattern shows that the soluble PAHs in seawater and porewater samples are dominated by naphthalenes and 3 ring PAHs. This is in direct contrast to those of the sediment samples reported earlier, in which both light and heavy PAHs are present at comparable concentrations. The absence of heavy PAHs in soluble forms (<0.1-3.5 ng/L) is indicative of the strong binding of these PAHs to the dissolved or solid matters and their low seawater solubility. 展开更多
关键词 solid-phase microextraction POLYCYCLIC aromatic hydrocarbons dissolved organic matter marine sediment porewater PAH-DOM complex.
原文传递
In vivo solid phase microextraction for therapeutic monitoring and pharmacometabolomic fingerprinting of lung during in vivo lung perfusion of FOLFOX
19
作者 Nikita Looby Anna Roszkowska +5 位作者 Miao Yu German Rios-Gomez Mauricio Pipkin Barbara Bojko Marcelo Cypel Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第10期1195-1204,共10页
In vivo lung perfusion(IVLP)is a novel isolated lung technique developed to enable the local,in situ administration of high-dose chemotherapy to treat metastatic lung cancer.Combination therapy using folinic acid(FOL)... In vivo lung perfusion(IVLP)is a novel isolated lung technique developed to enable the local,in situ administration of high-dose chemotherapy to treat metastatic lung cancer.Combination therapy using folinic acid(FOL),5-fluorouracil(F),and oxaliplatin(OX)(FOLFOX)is routinely employed to treat several types of solid tumours in various tissues.However,F is characterized by large interpatient variability with respect to plasma concentration,which necessitates close monitoring during treatments using of this compound.Since plasma drug concentrations often do not reflect tissue drug concentrations,it is essential to utilize sample-preparation methods specifically suited to monitoring drug levels in target organs.In this work,in vivo solid-phase microextraction(in vivo SPME)is proposed as an effective tool for quantitative therapeutic drug monitoring of FOLFOX in porcine lungs during pre-clinical IVLP and intravenous(IV)trials.The concomitant extraction of other endogenous and exogenous small molecules from the lung and their detection via liquid chromatography coupled to high resolution mass spectrometry(LC-HRMS)enabled an assessment of FOLFOX's impact on the metabolomic profile of the lung and revealed the metabolic pathways associated with the route of administration(IVLP vs.IV)and the therapy itself.This study also shows that the immediate instrumental analysis of metabolomic samples is ideal,as long-term storage at80℃ results in changes in the metabolite content in the sample extracts. 展开更多
关键词 In vivo lung perfusion solid-phase microextraction CHEMOTHERAPY Metabolomics Therapeutic drug monitoring
下载PDF
Scalable solid-phase synthesis of defect-rich graphene for oxygen reduction electrocatalysis 被引量:1
20
作者 Chunxiao Dong Li Yang +4 位作者 Cheng Lian Xiaoling Yang Yihua Zhu Hongliang Jiang Chunzhong Li 《Green Energy & Environment》 SCIE EI CSCD 2023年第1期224-232,共9页
Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon ... Defect-engineered carbon materials have been emerged as promising electrocatalysts for oxygen reduction reaction(ORR)in metal-air batteries.Developing a facile strategy for the preparation of highly active nanocarbon electrocatalysts remains challenging.Herein,a low-cost and simple route is developed to synthesize defective graphene by pyrolyzing the mixture of glucose and carbon nitride.Molecular dynamics simulations reveal that the graphene formation is ascribed to two-dimensional layered feature of carbon nitride,and high compatibility of carbon nitride/glucose systems.Structural measurements suggest that the graphene possesses rich edge and topological defects.The graphene catalyst exhibits higher power density than commercial Pt/C catalyst in a primary Zn-air battery.Combining experimental results and theoretical thermodynamic analysis,it is identified that graphitic nitrogen-modified topological defects at carbon framework edges are responsible for the decent ORR performance.The strategy presented in this work can be can be scaled up readily to fabricate defective carbon materials. 展开更多
关键词 Carbon materials ELECTROCATALYSIS Oxygen reduction reaction solid-phase synthesis Zn-air battery
下载PDF
上一页 1 2 195 下一页 到第
使用帮助 返回顶部