The analysis of 10 normal and 51 mitral valve pathology making a total of 61 heart sound signals that were obtained with Littmann 4100 Digital Stethoscope were conducted in this study.Following the recorded sound sign...The analysis of 10 normal and 51 mitral valve pathology making a total of 61 heart sound signals that were obtained with Littmann 4100 Digital Stethoscope were conducted in this study.Following the recorded sound signals were denoised by using wavelet filters,the signals were applied bicoherence analysis that is an high order spectral analysis method.It has been demonstrated that varieties of mitral valve pathology could be determined by three-dimensional surfaces of bicoherence and maximum bicoherence values.展开更多
This article investigates the relationships between heart valve closure timing intervals and left ventricular systolic blood pressure (LVSBP). For this investigation, the cardiopulmonary system is modeled as an analog...This article investigates the relationships between heart valve closure timing intervals and left ventricular systolic blood pressure (LVSBP). For this investigation, the cardiopulmonary system is modeled as an analog circuit, including heart chambers, the distal and proximal aorta, distal and proximal systemic arteries/veins, systemic capillaries, the vena cava, the distal and proximal pulmonary artery, distal and proximal pulmonary arteries/veins, pulmonary capillaries and physiological control of heart rate and cardiac contractibility. In this model, the ventricles, atria and arteries were modeled as advanced pressur-volume relationships. A vagal-sympathetic mechanism was adopted to simulate transient systemic and pulmonary blood pressure. Four intervals, i.e., the timing interval between mitral and aortic valve closure (TIMA), the timing interval between aortic and mitral valve closure (TIAM), the timing interval be- tween aortic and pulmonary valve closure (TIAP) and the timing interval between mitral and tricuspid valve closure (TIMT), are further defined in a heart cycle to illustrate their relationships to LVSBP. Simula- tions showed that the TIMA, TIAM and TIAP have strong negative correlations with LVSBP;meanwhile, the TIMT has a slightly negative relationship with LVSBP. To further validate the relationships, 6 healthy male subjects were experimentally evaluated. The intervals were extracted from non-invasively sampled heart sound signals taken from the surface of the thorax. The experiments showed relationships consistent with those obtained by simulations. These relationships may have potential applications for noninvasively accessing LVSBP in real-time with a high time resolution of one heartbeat.展开更多
文摘The analysis of 10 normal and 51 mitral valve pathology making a total of 61 heart sound signals that were obtained with Littmann 4100 Digital Stethoscope were conducted in this study.Following the recorded sound signals were denoised by using wavelet filters,the signals were applied bicoherence analysis that is an high order spectral analysis method.It has been demonstrated that varieties of mitral valve pathology could be determined by three-dimensional surfaces of bicoherence and maximum bicoherence values.
文摘This article investigates the relationships between heart valve closure timing intervals and left ventricular systolic blood pressure (LVSBP). For this investigation, the cardiopulmonary system is modeled as an analog circuit, including heart chambers, the distal and proximal aorta, distal and proximal systemic arteries/veins, systemic capillaries, the vena cava, the distal and proximal pulmonary artery, distal and proximal pulmonary arteries/veins, pulmonary capillaries and physiological control of heart rate and cardiac contractibility. In this model, the ventricles, atria and arteries were modeled as advanced pressur-volume relationships. A vagal-sympathetic mechanism was adopted to simulate transient systemic and pulmonary blood pressure. Four intervals, i.e., the timing interval between mitral and aortic valve closure (TIMA), the timing interval between aortic and mitral valve closure (TIAM), the timing interval be- tween aortic and pulmonary valve closure (TIAP) and the timing interval between mitral and tricuspid valve closure (TIMT), are further defined in a heart cycle to illustrate their relationships to LVSBP. Simula- tions showed that the TIMA, TIAM and TIAP have strong negative correlations with LVSBP;meanwhile, the TIMT has a slightly negative relationship with LVSBP. To further validate the relationships, 6 healthy male subjects were experimentally evaluated. The intervals were extracted from non-invasively sampled heart sound signals taken from the surface of the thorax. The experiments showed relationships consistent with those obtained by simulations. These relationships may have potential applications for noninvasively accessing LVSBP in real-time with a high time resolution of one heartbeat.