期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Effects of Dietary Energy Level and Source on Blood Metabolites,Hormone Secretion and Follicular Fluid Composition in Gilts
1
作者 ZHOU Dong-sheng ZHUO Yong +3 位作者 WU De WANG Yan-zhong TAN Xian-yi ZHOU Ping 《畜牧兽医学报》 CAS CSCD 北大核心 2010年第S1期43-50,共8页
The objective of the study was to investigate the effects of dietary energy levels and sources on the blood metabolites,hormone secretion and the composition of follicular fluid in gilts.Fifty-four gilts with initial ... The objective of the study was to investigate the effects of dietary energy levels and sources on the blood metabolites,hormone secretion and the composition of follicular fluid in gilts.Fifty-four gilts with initial body weight of(59±4.2) kg were randomly allotted to six treatments.Treatments were low, normal,and high energy feeding levels,which were 87.5%,100%and 112.5%of recommendatory energy requirements by NRC(1998),respectively,and dietary energy sources(starch or fat).Blood samples and follicular fluids were collected on D18 and D19 of the second estrous cycle.The results showed that plasma concentrations of triglycerides and total cholesterol were higher in the fat group than that in the starch group(P【0.05),but those of glucose were similar between the two energy sources(P】0.05);dietary energy level exerted no effect on blood metabolites concentration(P】0.05).Gilts fed the high energy diet had a higher area under curve of plasma insulin(Insulin AUC),insulin-like growth factor-Ⅰ(IGF-Ⅰ) and leptin than did gilts fed the lower energy diet(P【0.05),but there was no significant difference between fat versus starch(P】0.05).Luteinizing hormone(LH) pulses were higher in gilts fed high energy rather than that in low energy diets(P】0.05),plasma concentration of estradiol(E<sub>2</sub>) was higher in the fat group than that in the starch group(P【0.05).The number of large follicles(diameter≥4 mm) and concentrations of IGF-Ⅰand E<sub>2</sub> in follicular fluid were increasing significant as the level of energy increased(P【0.05),but the numbers of large follicles and follicular fluid composition were not affected by the source of dietary energy(P】0.05).The results indicate that gilts fed high energy diets had elevated plasma concentrations of metabolic hormones,IGF-Ⅰand LH secretion,and increased follicular fluid concentrations of IGF-Ⅰ,E<sub>2</sub> and numbers of large follicles;gilts fed the dietary fat had a higher plasma concentration of cholesterol and E<sub>2</sub>. 展开更多
关键词 dietary energy levels and sources GILTS METABOLITES hormone secretion follicle fluid composition
下载PDF
Fluke 9640A RF Reference Source combines level precision,dynamic range,frequency capability in a single instrument
2
作者 Stream lines workload enables automationof calibration procedures with MET/CAL(Plus Calibration Measurement Software 《国外电子测量技术》 2007年第1期81-81,共1页
关键词 source RF Fluke 9640A RF Reference source combines level precision dynamic range frequency capability in a single instrument
下载PDF
On electro-acoustic characteristics of a marine broadband sparker for seismic exploration
3
作者 Jing LI Kai LIU +3 位作者 Liancheng ZHANG Chenguang LIU Yanliang PEI Baohua LIU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第3期760-771,共12页
The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic explora... The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic exploration based on a high broadband sparker source is an important approach to reveal seabed stratum and reservoir structure,and identify geohazard.To optimize the performance of sparker seismic source,we investigated the electro-acoustic characteristics of spark discharge under conditions of different charging voltages and electrode numbers.Results show that the sound source level increased with the increase of the charging voltage,whereas the main frequency decreased when the charging voltage increases.In addition,it was found that the charging capacitance had more obvious influence on the main frequency than the sound source level did.Although the load energy decreased with increasing electrode number,the sound source level still increased but the main frequency decreased.Meanwhile,the primary to bubble(P/B)ratio increased with the increase of the electrode number.To gain a deeper insight into the electro-acoustic characteristics,we investigate the relationship between sound source level and power peak,from which a good correlation was observed.A more practical statistical analysis on the rise rate of current was processed,and a perfect logarithmic function was derived.Furthermore,we found that the main frequency was most possibly subjected to the electrical energy,especially the charging energy per electrode.The results indicate that the charging energy per electrode less than 10 J could increase the main frequency to above 300 Hz.At last,the main frequency could be reduced to 20 Hz when the charging energy of a single-electrode discharge was enhanced to over 4 kJ.This study shall be helpful in developing a sparker seismic source and improving the performance for marine engineering exploration and geohazard assessment. 展开更多
关键词 high-resolution marine seismic exploration sparker seismic source sound source level main frequency electro-acoustic characteristics
下载PDF
Pollution characteristics and health risk assessment of benzene homologues in ambient air in the northeastern urban area of Beijing, China 被引量:41
4
作者 Lei Li Hong Li +6 位作者 Xinmin Zhang Li Wang Linghong Xu Xuezhong Wang Yanting Yu Yujie Zhang Guan Cao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2014年第1期214-223,共10页
Ambient benzene homologues were measured at a site in the northeastern urban area of Beijing, China, from August 24 to September 4, 2012 by SUMMA canister sampling followed by laboratory determination using cryogenic ... Ambient benzene homologues were measured at a site in the northeastern urban area of Beijing, China, from August 24 to September 4, 2012 by SUMMA canister sampling followed by laboratory determination using cryogenic cold trap pre-concentration-GC-MS/FID, and their health risks were also assessed. Daily total benzene homologues ranged from 0.99 to 49.71 μg/m3 with an average of 11.98 μg/m3. Benzene homologues showed higher concentrations in the morning and evening than that at noontime. Comparison with previous studies revealed a trend of decrease for ambient benzene homologues probably due to the effective emission control in Beijing in recent years. Vehicular exhaust was the main source while volatilization of paints and solvents also made substantial contributions. Health risk assessment showed that BTEX (benzene, toluene, ethylbenzene, o-xylene, m-xylene and p-xylene) and styrene had no appreciable adverse non-cancer health risks for the exposed population, while benzene has potential cancer risk of 1.34E-05. Available data from cities in China all implied that benzene imposes relatively higher cancer risk on the exposed populations and therefore strict control measures should be taken to further lower ambient benzene levels in China. 展开更多
关键词 benzene homologues ambient levels sources health risk
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部