In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ...In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.展开更多
Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using S...Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using Solid State Nuclear Track Detector (SSNTD) based passive detector technique. In this study, technical procedure has been applied in Karlsruhe diffusion chamber and LR-115, Type II strippable (Kodak Pathe, France) detector. The results have investigated how LR-115 work for Rn-220 by using Monazite ore to simultaneously measure Rn-222 and Rn-220. To carry out experiment, Karlsruhe diffusion chamber is used to with and without Poly-Ethylene (PE) membrane. Karlsruhe diffusion chamber with PE membrane only detect Rn-222, without PE membrane detect total Rn-222 and Rn-220. Precision evaluation by duplicate measure at 8 cm detector-source distance with relative standard deviation is less than 2.54%. Testing technical procedure, detectors have been sent to National Institute of Radiological Science (NIRS) for Rn-220 calibration exposure. After detectors have been calibration exposure at NIRS, it carried out all the following steps of procedure which set up at laboratory in 1NST, Vietnam. Finally, calibration factor calculated is 0.21 (tracks-cm2/Bq·m3·h) and constructed curve between integrated Tn-220 concentration and tracks density with factor R2 = 0.975.展开更多
文摘In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
文摘Thoron (Rn-220) is an invisible, odorless radioactive gas and nine times heavier than air. Purpose of project is to set up procedure to determine Rn-220 concentration which has been carried out in laboratory using Solid State Nuclear Track Detector (SSNTD) based passive detector technique. In this study, technical procedure has been applied in Karlsruhe diffusion chamber and LR-115, Type II strippable (Kodak Pathe, France) detector. The results have investigated how LR-115 work for Rn-220 by using Monazite ore to simultaneously measure Rn-222 and Rn-220. To carry out experiment, Karlsruhe diffusion chamber is used to with and without Poly-Ethylene (PE) membrane. Karlsruhe diffusion chamber with PE membrane only detect Rn-222, without PE membrane detect total Rn-222 and Rn-220. Precision evaluation by duplicate measure at 8 cm detector-source distance with relative standard deviation is less than 2.54%. Testing technical procedure, detectors have been sent to National Institute of Radiological Science (NIRS) for Rn-220 calibration exposure. After detectors have been calibration exposure at NIRS, it carried out all the following steps of procedure which set up at laboratory in 1NST, Vietnam. Finally, calibration factor calculated is 0.21 (tracks-cm2/Bq·m3·h) and constructed curve between integrated Tn-220 concentration and tracks density with factor R2 = 0.975.