期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Speckle-tracking echocardiography for detecting myocardial dysfunction in sepsis and septic shock patients:A single emergency department study 被引量:2
1
作者 Xuan Fu Xue Lin +4 位作者 Samuel Seery Li-na Zhao Hua-dong Zhu Jun Xu Xue-zhong Yu 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第3期175-181,共7页
BACKGROUND:Septic cardiomyopathy(SCM)occurs in the early stage of sepsis and septic shock,which has implications for treatment strategies and prognosis.Additionally,myocardial involvement in the early stages of sepsis... BACKGROUND:Septic cardiomyopathy(SCM)occurs in the early stage of sepsis and septic shock,which has implications for treatment strategies and prognosis.Additionally,myocardial involvement in the early stages of sepsis is difficult to identify.Here,we assess subclinical myocardial function using laboratory tests and speckle-tracking echocardiography(STE).METHODS:Emergency department patients diagnosed with sepsis or septic shock were included for analysis.Those with other causes of acute or pre-existing cardiac dysfunction were excluded.Transthoracic echocardiography(TTE),including conventional echocardiography and STE,were performed for all patients three hours after initial resuscitation.Samples for laboratory tests were taken around the time of TTE.RESULTS:Left ventricular functions of 60 patients were analyzed,including 21 septic shock patients and 39 sepsis patients.There was no significant difference in global longitudinal strain(GLS),global circumferential strain(GCS),or global radical strain(GRS)between patients with sepsis and septic shock(all with P>0.05).However,GLS and GCS were significantly less negative in patients with abnormal troponin levels or in patients with abnormal left ventricular ejection fraction(LVEF)values(all with P<0.05).There were also moderate correlations between GLS and levels of cTnI(r=0.40,P=0.002)or N-terminal pro-B-type natriuretic peptide(NT-proBNP)(r=0.44,P=0.001)in sepsis and septic shock patients.CONCLUSION:Myocardial dysfunction,e.g.,lower LVEF or less negative GLS in patients with sepsis or septic shock,is more affected by myocardial injury.GLS could be incorporated into mainstream clinical practice as a supplementary LVEF parameter,especially for those with elevated troponin levels. 展开更多
关键词 SEPSIS Septic shock speckle-tracking echocardiography Global longitudinal strain Global circumferential strain
下载PDF
Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Chronic Kidney Failure 被引量:1
2
作者 Yu-bo WANG Hui HUANG +4 位作者 Shan LIN Mei-jia HAO Lu-jiao HE Kun LIU Xiao-jun BI 《Current Medical Science》 SCIE CAS 2022年第4期895-901,共7页
Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional... Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional and three-dimensional transthoracic echocardiography was performed on 30 patients with CKF.The ejection fraction,mass and global peak longitudinal strain,global circumferential strain,global area strain,and global radial strain of the left ventricle were calculated.Results:The ejection fraction,mass and global peak longitudinal strain(GLS),global circumferential strain(GCS),global area strain(GAS),and global radial strain(GRS)in the CKF group were significantly lower than those in the control group.Simultaneously,the GLS,GCS,GAS and GRS were well correlated with the ejection fraction.For patients with normal ejection fraction in the CKF group,the GLS,GCS,GAS and GRS were lower than those in the control group,while the left ventricular mass was significantly higher in CKF patients than in the control group.For patients with hypertension in the CKF group,ejection fraction,GLS,GCS,GAS and GRS calculated using three-dimensional echocardiography were significantly lower than those in patients with normal blood pressure;however,the myocardial mass was higher.Conclusions:The parameters(GLS,GCS,GAS and GRS)calculated using three-dimensional speckle-tracking software were lower in the CKF group.Simultaneously,the left ventricular mass was higher in CFK patients than in the control group,thus showing that the myocardial contraction function was impaired and that myocardial remodeling had occurred. 展开更多
关键词 three-dimensional speckle-tracking echocardiography left ventricle ejection fraction STRAIN chronic kidney failure
下载PDF
Effects of sevoflurane on left ventricular function by speckletracking echocardiography in coronary bypass patients: A randomized trial
3
作者 Chanjuan Gong Xiaokai Zhou +3 位作者 Yin Fang Yanjuan Zhang Linjia Zhu Zhengnian Ding 《The Journal of Biomedical Research》 CAS CSCD 2024年第1期76-86,共11页
The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to ass... The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies. 展开更多
关键词 coronary artery bypass grafting speckle-tracking echocardiography SEVOFLURANE transesophageal echocardiography
下载PDF
Specific alterations of regional myocardial work in strength-trained athletes using anabolic androgenic steroids compared to athletes with genetic hypertrophic cardiomyopathy
4
作者 Antoine Grandperrin Frédéric Schnell +4 位作者 Erwan Donal Elena Galli Christophe Hedon Olivier Cazorla Stéphane Nottin 《Journal of Sport and Health Science》 SCIE CAS CSCD 2023年第4期477-485,共9页
Background:Strength-trained athletes using anabolic androgenic steroids(AAS)have left ventricular(LV)hypertrophy and myocardial fibrosis that can lead to sudden cardiac death.A similar feature was described in athlete... Background:Strength-trained athletes using anabolic androgenic steroids(AAS)have left ventricular(LV)hypertrophy and myocardial fibrosis that can lead to sudden cardiac death.A similar feature was described in athletes with hypertrophic cardiomyopathy(HCM),which complicates the diagnosis for clinicians.In this context,we aimed to compare the LV function of the 2 populations by measuring global and regional strain and myocardial work using speckle-tracking imaging.Methods:Twenty-four strength-trained asymptomatic athletes using AAS(AAS-Athletes),22 athletes diagnosed with HCM(HCM-Athletes),and 20 healthy control athletes(Ctrl-Athletes)underwent a resting echocardiography to assess LV function.We evaluated LV global and regional strains and myocardial work,with an evaluation of the constructive work(CW),wasted work,and work efficiency(WE).Results:Compared to Ctrl-Athletes,both AAS-Athletes and HCM-Athletes had a thicker interventricular septum,with maj ored values in HCM-Athletes.LV strain was reduced in AAS-Athletes and even more in HCM-Athletes.Consequently,global WE was significantly diminished in both AAS and HCM-Athletes(93%±2%in Ctrl-Athletes,90%±4%in AAS-Athletes,and 90%±5%in HCM-Athletes(mean±SD);p<0.05).Constructive work and WE regional analysis showed specific alterations,with the basal septal segments preferentially affected in AAS-Athletes,and both septal and apical segments affected in HCM-Athletes.Conclusion:The regional evaluation of myocardial work reported specific alterations of the major LV hypertrophy induced by the regular use of AAS compared to the LV hypertrophy due to HCM.This finding could help clinicians to differentiate between these 2 forms of pathological hypertrophy. 展开更多
关键词 Anabolic androgenic steroids Hypertrophic cardiomyopathy Left ventricular function Myocardial work speckle-tracking echocardiography
下载PDF
Methodology development and application of X-ray imaging beamline at SSRF 被引量:7
5
作者 Hong-Lan Xie Biao Deng +7 位作者 Guo-Hao Du Ya-Nan Fu Han Guo Yan-Ling Xue Guan-Yun Peng Fen Tao Ling Zhang Ti-Qiao Xiao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期74-94,共21页
This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the... This paper introduces some latest developments regarding the X-ray imaging methodology and applications of the X-ray imaging and biomedical application beamline(BL13W1)at Shanghai Synchrotron Radiation Facility in the past 5 years.The photon energy range of the beamline is 8–72.5 keV.Several sets of X-ray imaging detectors with different pixel sizes(0.19–24 lm)are used to realize X-ray microcomputed tomography(X-ray micro-CT)and X-ray in-line phase-contrast imaging.To satisfy the requirements of user experiments,new X-ray imaging methods and image processing techniques are developed.In vivo dynamic micro-CT experiments with living insects are performed in 0.5 s(sampling rate of 2 Hz,2 tomograms/s)with a monochromatic beam from a wiggler source and in 40 ms(sampling rate of 25 Hz,25 tomograms/s)with a white beam from a bending magnet source.A new X-ray imaging method known as move contrast X-ray imaging is proposed,with which blood flow and moving tissues in raw images can be distinguished according to their moving frequencies in the time domain.Furthermore,X-ray speckle-tracking imaging with twice exposures to eliminate the edge enhancement effect is developed.A high-precision quantification method is realized to measure complex three-dimensional blood vessels obtained via X-ray micro-CT.X-ray imaging methods such as three-dimensional X-ray diffraction microscopy,small-angle X-ray scattering CT,and X-ray fluorescence CT are developed,in which the X-ray micro-CT imaging method is combined with other contrast mechanisms such as diffraction,scattering,and fluorescence contrasts respectively.Moreover,an X-ray nano-CT experiment is performed with a 100 nm spatial resolution.Typical user experimental results from the fields of material science,biomedicine,paleontology,physics,chemistry,and environmental science obtained on the beamline are provided. 展开更多
关键词 X-ray imaging X-ray in-line phase-contrast imaging X-ray micro-CT Dynamic micro-CT X-ray speckle-tracking imaging 3DXRD SAXS-CT X-ray fluorescence CT X-ray nano-CT Move contrast X-ray imaging
下载PDF
The Peculiarities of Acoustical Monitoring of Moving Objects in Shallow Water Areas
6
作者 Manel Monteiro Victor Svet Donald Sandilands 《Open Journal of Acoustics》 2014年第3期145-154,共10页
The article considers peculiarities of underwater monitoring of moving objects in the shallow water areas, particularly seaports. These areas are characterized by a multitude of factors influencing the efficiency of d... The article considers peculiarities of underwater monitoring of moving objects in the shallow water areas, particularly seaports. These areas are characterized by a multitude of factors influencing the efficiency of detection. Nonstationarity conditions of sound propagation and specific interference caused by shipping are the major factors. The various algorithms for the space-time signal processing have been tested and some experimental results are presented. It has been shown that the use of clipped mode in conjunction with the correlation processing of wideband signals and subsequent speckle tracking allow realizing high efficiency of monitoring. 展开更多
关键词 Acoustical UNDERWATER MONITORING SHALLOW Water Areas Multi-Ray PROPAGATION Correlation Processing speckle-tracking
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部