Objective:To investigate the diagnostic value of spectral CT reconstruction mode for carotid atherosclerotic plaque lesions.Methods:From January 2017 to January 2019,70 patients with carotid atherosclerotic plaque les...Objective:To investigate the diagnostic value of spectral CT reconstruction mode for carotid atherosclerotic plaque lesions.Methods:From January 2017 to January 2019,70 patients with carotid atherosclerotic plaque lesions in our hospita1 were selected as the research object.A11 patients were diagnosed with cervical vascular color Doppler ultrasound and spectral CT scan under spectral cr reconstruction mode.Taking the results of coronaryf angiography as the"gold standard",the clinical value of the two examination methods in the diagnosis of carotid atherosclerotic plaque lesions was compared and analyzed.Results:Coronary angiography diagnosis confirmed that 33 of 70 patients with suspected carotid atherosclerotic plaque lesions had vulnerable plaques and 37 had stable plaques.The accuracy of Spectral CT examination of carotid artery plaque was 87.14%(61/70),sensitivity was 90.91%(30/33),specificity was 83.78%(31/37),and the positive predictive value was 83.33%(30/36),the negative predictive value is 91.76%(31/34),which is higher than that of cervical vascular ultrasonography(61.43%,60.61%,56.76%,57.89%,65.63%),the difference is statistically significant(P<0.05).Conclusion:The application of Spectral CT in the clinical diagnosis and treatment of carotid atherosclerotic plaque lesions with higher accuracy,sensitivity and specificity,is more significant and can provide a more reliable and effective imaging basis.展开更多
A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the...A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the traditional wholeprofile fitting method, this new method can increase the concentration detection upper limit of a single absorption line by about 8.7 times. High-concentration water vapor is measured using TDLAS technology, the total water vapor pressure and the self-broadened half-width coefficient of the spectrum were simultaneously measured from incomplete saturatedabsorption spectra and compared with high-precision pressure sensors and the HITRAN databases. Their maximum relative deviations were about 4.63% and 9.10%, respectively. These results show that the spectral profile reconstruction method has great application potential for expanding the dynamic range of single-line measurements to higher concentrations,especially for in-situ online measurements under complex conditions, such as over large temperature and concentration dynamic ranges.展开更多
By studying the traditional spectral reflectance reconstruction method, spectral reflectance and the relative spectral power distribution of a lighting source are sparsely decomposed, and the orthogonal property of th...By studying the traditional spectral reflectance reconstruction method, spectral reflectance and the relative spectral power distribution of a lighting source are sparsely decomposed, and the orthogonal property of the principal component orthogonal basis is used to eliminate basis; then spectral reflectance data are obtained by solving a sparse coefficient. After theoretical analysis, the spectral reflectance reconstruction based on sparse prior knowledge of the principal component orthogonal basis by a single-pixel detector is carried out by software simulation and experiment. It can reduce the complexity and cost of the system, and has certain significance for the improvement of multispectral image acquisition technology.展开更多
文摘Objective:To investigate the diagnostic value of spectral CT reconstruction mode for carotid atherosclerotic plaque lesions.Methods:From January 2017 to January 2019,70 patients with carotid atherosclerotic plaque lesions in our hospita1 were selected as the research object.A11 patients were diagnosed with cervical vascular color Doppler ultrasound and spectral CT scan under spectral cr reconstruction mode.Taking the results of coronaryf angiography as the"gold standard",the clinical value of the two examination methods in the diagnosis of carotid atherosclerotic plaque lesions was compared and analyzed.Results:Coronary angiography diagnosis confirmed that 33 of 70 patients with suspected carotid atherosclerotic plaque lesions had vulnerable plaques and 37 had stable plaques.The accuracy of Spectral CT examination of carotid artery plaque was 87.14%(61/70),sensitivity was 90.91%(30/33),specificity was 83.78%(31/37),and the positive predictive value was 83.33%(30/36),the negative predictive value is 91.76%(31/34),which is higher than that of cervical vascular ultrasonography(61.43%,60.61%,56.76%,57.89%,65.63%),the difference is statistically significant(P<0.05).Conclusion:The application of Spectral CT in the clinical diagnosis and treatment of carotid atherosclerotic plaque lesions with higher accuracy,sensitivity and specificity,is more significant and can provide a more reliable and effective imaging basis.
基金supported by the Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization (Grant No. 2013A061401005)the Key Laboratory of Efficient and Clean Energy Utilization of Guangdong Higher Education Institutes (Grant No. KLB10004)。
文摘A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the traditional wholeprofile fitting method, this new method can increase the concentration detection upper limit of a single absorption line by about 8.7 times. High-concentration water vapor is measured using TDLAS technology, the total water vapor pressure and the self-broadened half-width coefficient of the spectrum were simultaneously measured from incomplete saturatedabsorption spectra and compared with high-precision pressure sensors and the HITRAN databases. Their maximum relative deviations were about 4.63% and 9.10%, respectively. These results show that the spectral profile reconstruction method has great application potential for expanding the dynamic range of single-line measurements to higher concentrations,especially for in-situ online measurements under complex conditions, such as over large temperature and concentration dynamic ranges.
基金supported by the National Natural Science Foundation of China (Grant No.61405115)the Natural Science Foundation of Shanghai (Grant No.14ZR1428400)+1 种基金the Innovation Project of Shanghai Municipal Education Commission (Grant No.14YZ099)National Basic Research Program of China (973 Program) (Grant No.2015CB352004)
文摘By studying the traditional spectral reflectance reconstruction method, spectral reflectance and the relative spectral power distribution of a lighting source are sparsely decomposed, and the orthogonal property of the principal component orthogonal basis is used to eliminate basis; then spectral reflectance data are obtained by solving a sparse coefficient. After theoretical analysis, the spectral reflectance reconstruction based on sparse prior knowledge of the principal component orthogonal basis by a single-pixel detector is carried out by software simulation and experiment. It can reduce the complexity and cost of the system, and has certain significance for the improvement of multispectral image acquisition technology.