期刊文献+
共找到1,387篇文章
< 1 2 70 >
每页显示 20 50 100
Heavy Metal Detection in Soils by Laser Induced Breakdown Spectroscopy Using Hemispherical Spatial Confinement 被引量:6
1
作者 孟德硕 赵南京 +5 位作者 马明俊 王寅 胡丽 余洋 方丽 刘文清 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期632-637,共6页
Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to... Spatial confinement has great potential for Laser Induced Breakdown Spectroscopy (LIBS) instruments after it has been proven that it has the ability to enhance the LIBS signal strength and repeatability. In order to achieve in-situ measurement of heavy metals in farmland soils by LIBS, a hemispherical spatial confinement device is designed and used to collect plasma spectra, in which the optical fibers directly collect the breakdown spectroscopy of the soil samples. This device could effectively increase the stability of the spectrum intensity of soil. It also has other advantages, such as ease of installation, and its small and compact size. The relationship between the spectrum intensity and the laser pulse energy is studied for this device. It is found that the breakdown threshold is 160 cm-2, and when the laser fluence increases to 250 J/cm2, the spectrum intensity reaches its maximum. Four different kinds of laser pulse energy were set up and in each case the limits of detection of Cd, Cu, Ni, Pb and Zn were calculated. The results show that when the laser pulse fluence was 2.12 GW/cm2, we obtained the smallest limits of detection of these heavy metals, which are all under 10 mg/kg. This device can satisfy the needs of heavy metal in-situ detection, and in the next step it will be integrated into a portable LIBS instrument. 展开更多
关键词 laser induced breakdown spectroscopy hemispherical spatial confinement laser fiuence limit of detection
下载PDF
Effect of parameter setting and spectral normalization approach on study of matrix effect by laser induced breakdown spectroscopy of Ag–Zn binary composites 被引量:1
2
作者 Harse SATTAR Liying SUN +3 位作者 Muhammad IMRAN Ran HAI Ding WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期155-166,共12页
The complex nature of laser-material interaction causes non-stoichiometric ablation of alloy samples.This is attributed to matrix effect, which reduces analyzing capability. To address this issue, the analytical perfo... The complex nature of laser-material interaction causes non-stoichiometric ablation of alloy samples.This is attributed to matrix effect, which reduces analyzing capability. To address this issue, the analytical performance of three different normalization methods, namely normalization with background, internal normalization and three point smoothing techniques at different parameter settings is studied for quantification of Ag and Zn by Laser induced breakdown spectroscopy(LIBS).The LIBS spectra of five known concentration of silver zinc binary composites have been investigated at various laser irradiances(LIs). Calibration curves for both Ag(I) line(4d^(10)5s^2S_(1/2)→4d^(10)5p^2P_(1/2) at 338.28 nm) and Zn(I) line(4s5s^3S_1→4s4p^3P_2 at 481.053 nm) have been determined at LI of 5.86?×?10^(10)W cm^(-2). Slopes of these calibration curves provide the valuation of matrix effect in the Ag–Zn composites. With careful sample preparation and normalization after smoothing at optimum parameter setting(OPS), the minimization of sample matrix effect has been successfully achieved. A good linearity has been obtained in Ag and Zn calibration curve at OPS when normalized the whole area of spectrum after smoothing and the obtained coefficients of determination values were R^2?=?0.995 and 0.998 closer to 1. The results of matrix effect have been further verified by analysis of plasma parameters. Both plasma parameters showed no change with varying concentration at OPS. However, at high concentration of Ag, the observed significant changes in both plasma parameters at common parameter setting PS-1 and PS-2 were the gesture of matrix effect. In our case, the better analytical results were obtained at smoothing function with optimized parameter setting that indicates it is more efficient than normalization with background and internal normalization method. 展开更多
关键词 Ag–Zn COMPOSITES laser induced breakdown spectroscopy optimum parameter setting SELF-ABSORPTION matrix EFFECT
下载PDF
Quantitative Analysis of Cr in Milk Powder by Laser Induced Breakdown Spectroscopy( LIBS) 被引量:1
3
作者 Gangmeng GONG Jun YANG 《Agricultural Biotechnology》 CAS 2015年第6期66-69,共4页
At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly det... At present, heavy metal pollution in food occurs frequently, which requires a novel method for rapid detection. Laser induced breakdown spectroscopy (LIBS) is a new technique for rapid and environmental friendly detection, but it lacks high sensitivity and stability which restrict its development. In this study, Cr-polluted infant milk powder was used as experimental material to explore the feasibility of the application of LIBS technique in food safety detection. Aiming at improving the precision and accuracy of Cr detection by LIBS technique, LIBS spectra of samples were collected by a spectrometer with an intensified charge-cou- pled device (ICCD) using three gratings with different resolutions to comprehensively compare and analyze the stability, sensitivity and quantitative analysis accura- cy of LIBS detection. The results showed that average relative standard deviation (RSD) of LIBS spectral intensity was below 10%, indicating good stability. LIBS signals were collected by three gratings for quantitative analysis, and the results demonstrated that the linear correlation coefficient R2 of fitting curves was 0. 248 87, 0.903 12 and 0.992 81, respectively; the relative errors between actual and predicted concentrations were 38.23%, 8.84% and 7.43%, respectively, indicating that gratings with higher resolutions could lead to higher linear correlation coefficient and better detection accuracy. According to the results, high-resolu- tion spectrometer could significantly improve the accuracy of LIBS detection of Cr concentration in milk powder, suggesting that it is feasible to detect heavy metals in food by LIBS technique with the improvement of core device performance. 展开更多
关键词 laser induced breakdown spectroscopy Milk powder Spectral resolution CR
下载PDF
Self-Absorption Effects on Electron Temperature-Measurements Utilizing Laser Induced Breakdown Spectroscopy (LIBS)-Techniques 被引量:1
4
作者 Shawqi A. M. Mansour 《Optics and Photonics Journal》 2015年第3期79-90,共12页
In the present work, we have studied the temporal evolution of aluminum alloy plasma produced by the fundamental (1064 nm) of a Q-switched Nd:YAG laser by placing the target material in air at atmospheric pressure. Th... In the present work, we have studied the temporal evolution of aluminum alloy plasma produced by the fundamental (1064 nm) of a Q-switched Nd:YAG laser by placing the target material in air at atmospheric pressure. The four Al I-neutral lines at 308.21, 309.27, 394.40 and 369.15 nm as well as Al II-ionic lines at 281.61, 385.64 and 466.30 nm are used for the determination of the electron temperature Te using Saha-Boltzmann plot method. The neutral aluminum lines were found to suffer from optical thickness which manifested itself on the form of scattered points around the Saha-Boltzmann line. The isolated optically thin hydrogen Hα-line at 656.27 nm appeared in the spectra under the same experimental conditions was used to correct the Al I-lines which contained some optical thickness. The measurements were repeated at different delay times ranging from 1 to 5 μs. The comparison between the deduced electron temperatures from aluminum neutral lines before correction against the effect self-absorption to that after correction revealed a precise value in temperature. The results sure that, in case of the presence of self-absorption effect the temperature varies from (1.4067 - 1.2548 eV) as the delay time is varied from 0 to 5 μs. Whereas, in the case of repairing against the effect, it varies from (1.2826 - 0.8961 eV) for the same delay time variation. 展开更多
关键词 laser Induces breakdown spectroscopy (LIBS) SELF-ABSORPTION (SA) Saha-Boltzmann PLOT Delay Time (Td) Electron Number Density (Ne) Plasma Temperature (Te)
下载PDF
Comparison of Calibration Curve Method and Partial Least Square Method in the Laser Induced Breakdown Spectroscopy Quantitative Analysis 被引量:1
5
作者 Zhi-bo Cong Lan-xiang Sun +2 位作者 Yong Xin Yang Li Li-feng Qi 《Journal of Computer and Communications》 2013年第7期14-18,共5页
The Laser Induced Breakdown Spectroscopy (LIBS) is a fast, non-contact, no sample preparation analytic technology;it is very suitable for on-line analysis of alloy composition. In the copper smelting industry, analysi... The Laser Induced Breakdown Spectroscopy (LIBS) is a fast, non-contact, no sample preparation analytic technology;it is very suitable for on-line analysis of alloy composition. In the copper smelting industry, analysis and control of the copper alloy concentration affect the quality of the products greatly, so LIBS is an efficient quantitative analysis tech- nology in the copper smelting industry. But for the lead brass, the components of Pb, Al and Ni elements are very low and the atomic emission lines are easily submerged under copper complex characteristic spectral lines because of the matrix effects. So it is difficult to get the online quantitative result of these important elements. In this paper, both the partial least squares (PLS) method and the calibration curve (CC) method are used to quantitatively analyze the laser induced breakdown spectroscopy data which is obtained from the standard lead brass alloy samples. Both the major and trace elements were quantitatively analyzed. By comparing the two results of the different calibration method, some useful results were obtained: both for major and trace elements, the PLS method was better than the CC method in quantitative analysis. And the regression coefficient of PLS method is compared with the original spectral data with background interference to explain the advantage of the PLS method in the LIBS quantitative analysis. Results proved that the PLS method used in laser induced breakdown spectroscopy was suitable for simultaneous quantitative analysis of different content elements in copper smelting industry. 展开更多
关键词 laser-induced breakdown spectroscopy (LIBS) PARTIAL Least SQUARE Method (PLS) Matrix Effects Quantitative Analysis
下载PDF
Consistency of intensity ratio between spectral lines with similar self-absorption characteristics during ungated laser induced breakdown spectroscopy measurements
6
作者 Jung-Hwan IN Youngmin MOON +1 位作者 Jang-Hee CHOI Sungho JEONG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期77-83,共7页
This work reports that the intensity ratio of spectral lines having similar self-absorption characteristics during laser induced breakdown spectroscopy(LIBS) analysis can become nearly constant over a wide range of ir... This work reports that the intensity ratio of spectral lines having similar self-absorption characteristics during laser induced breakdown spectroscopy(LIBS) analysis can become nearly constant over a wide range of irradiation conditions if the intensities are integrated over a sufficiently long time. It is shown that the plasma temperature and intensity ratio of these spectral lines have temporal similarity. The spectral lines with similar self-absorption properties may be selected to improve the accuracy and consistency of LIBS analysis results under an environment with fluctuating measurement conditions. 展开更多
关键词 laser induced breakdown spectroscopy INTENSITY ratio SELF-ABSORPTION CHARACTERISTICS CIGS solar cell
下载PDF
Investigation of Laser Induced Breakdown Spectroscopy(LIBS)for the Differentiation of Nerve and Gland Tissue-A Possible Application for a Laser Surgery Feedback Control Mechanism
7
作者 F.MEHARI M.ROHDE +6 位作者 C.KNIPFER R.KANAWADE F.KLAMPFL W.ADLER N.OETTER F.STELZLE M.SCHMIDT 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第6期654-660,共7页
Laser surgery provides clean,fast and accurate modeling of tissue.However,the inability to determine what kind of tissue is being ablated at the bottom of the cut may lead to the iatrogenic damage of structures that w... Laser surgery provides clean,fast and accurate modeling of tissue.However,the inability to determine what kind of tissue is being ablated at the bottom of the cut may lead to the iatrogenic damage of structures that were meant to be preserved.In this context,nerve preservation is one of the key challenges in any surgical procedure.One example is the treatment of parotid gland pathologies,where the facial nerve(N.VII) and its main branches run through and fan out inside the glands parenchyma.A feedback system that automatically stops the ablation to prevent nerve-tissue damage could greatly increase the applicability and safety of surgical laser systems.In the present study,Laser Induced Breakdown Spectroscopy(LIBS) is used to differentiate between nerve and gland tissue of an ex-vivo pig animal model.The LIBS results obtained in this preliminary experiment suggest that the measured spectra,containing atomic and molecular emissions,can be used to differentiate between the two tissue types.The measurements and differentiation were performed in open air and under normal stray light conditions. 展开更多
关键词 laser induced breakdown spectroscopy plasma chemical composition nerveparotid gland
下载PDF
Application of Laser Induced Breakdown Spectroscopy in Early Detection of Red Palm Weevil:(Rhynchophorus ferrugineus)Infestation in Date Palm 被引量:1
8
作者 W.A.FAROOQ K.G.RASOOL +1 位作者 Walid TAWFIK A.S.ALDAWOOD 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期948-952,共5页
The Kingdom of Saudi Arabia is one of the leading date producing countries. Unfortunately, this important fruit crop is under great threat from the red palm weevil (RPW) (Rhynchophorus ferrugineus), which is a hig... The Kingdom of Saudi Arabia is one of the leading date producing countries. Unfortunately, this important fruit crop is under great threat from the red palm weevil (RPW) (Rhynchophorus ferrugineus), which is a highly invasive pest. Several techniques, including visual inspection, acoustic sensors, sniffer dogs, and pheromone traps have been tried to detect the early stages of a RPW infestation; however, each method has suffered certain logistical and implementation issues. We have applied laser induced breakdown spectroscopy (LIBS) for the early detection of RPW infestation. Through the analysis of the observed LIBS spectra of different infested and healthy samples, we have found presence of Ca, Mg, Na, C, K elements and OH, CN molecules. The spectra also reveal that with the population growth of the pest, the intensity of Mg and Ca atomic lines in LIBS spectra increases rapidly. Similar behavior is observed in the molecular lines of LIBS spectra. The obtained results indicate that the LIBS technique can be used for the early detection of RPW infestation without damaging the date palms. 展开更多
关键词 laser induced breakdown red palm weevil INFESTATION LIBS plasma
下载PDF
Study of Bacterial Samples Using Laser Induced Breakdown Spectroscopy
9
作者 W A FAROOQ M ATIF +4 位作者 W TAWFIK M S ALSALHI Z A ALAHMED M SARFRAZ J P SINGH 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第12期1141-1146,共6页
Laser-induced breakdown spectroscopy (LIBS) technique has been applied to inves- tigate two different types of bacteria, Escherichia coli (B1) and Micrococcus luteus (B2) deposited on glass slides using Spectrol... Laser-induced breakdown spectroscopy (LIBS) technique has been applied to inves- tigate two different types of bacteria, Escherichia coli (B1) and Micrococcus luteus (B2) deposited on glass slides using Spectrolaser 7000. LIBS spectra were analyzed using spectrolaser software. LIBS spectrum of glass substrate was compared with bacteria spectra. Ca, Mg, Na, K, P, S, C1, Fe, A1, Mn, Cu, C, H and CN-band appeared in bacterial samples in air. Two carbon lines at 193.02 nm, 247.88 nm and one hydrogen line at 656.28 nm with intensity ratios of 1.9, 1.83 and 1.53 appeared in bacterial samples B1 and B2 respectively. Carbon and hydrogen are the important components of the bio-samples like bacteria and other cancer cells. Investigation on LIBS spectra of the samples in He and Ar atmospheres is also presented. Ni lines appeared only in B2 sample in Ar atmosphere. From the present experimental results we are able to show that LIBS technique has a potential in the identification and discrimination of different types of bacteria. 展开更多
关键词 laser induced breakdown BACTERIA bio-samples and carbon lines
下载PDF
Aqueous ruthenium detection by microwave-assisted laser-induced breakdown spectroscopy
10
作者 Abu Farhan ABU KASIM M A WAKIL +2 位作者 Kevin GRANT Milton HEARN Zeyad T ALWAHABI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第8期32-39,共8页
Aqueous ruthenium was detected in real-time under ambient conditions using microwaveassisted laser-induced breakdown spectroscopy(MW-LIBS).A 10 mJ laser energy and 750 W microwave power were directed at an open liquid... Aqueous ruthenium was detected in real-time under ambient conditions using microwaveassisted laser-induced breakdown spectroscopy(MW-LIBS).A 10 mJ laser energy and 750 W microwave power were directed at an open liquid jet sample of ruthenium.It was observed that,for liquid flow,the coupling efficiency between the microwave and the laser-induced plasma was limited to 43%.The improvement in the ruthenium’s signal-to-noise ratio with MW-LIBS,with respect to LIBS,was 76-fold.Based on MW-LIBS,the limit of detection for aqueous ruthenium was determined to be 957±84 ppb. 展开更多
关键词 microwave-assisted laser induced breakdown spectroscopy ruthenium detection laser induced breakdown spectroscopy
下载PDF
Determination of Iron in Water Solution by Time-Resolved Femtosecond Laser-Induced Breakdown Spectroscopy 被引量:3
11
作者 Sergey S.GOLIK Alexey A.ILYIN +3 位作者 Michael Yu.BABIY Yulia S.BIRYUKOVA Vladimir V.LISITSA Oleg A.BUKIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期975-978,共4页
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi... The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection. 展开更多
关键词 femtosecond laser-induced breakdown spectroscopy LIBS femtosecond plasma IRON analysis of water atomic emission spectroscopy limit of detection
下载PDF
Evaluation of gases'molecular abundance ratio by fiber-optic laser-induced breakdown spectroscopy with a metal-assisted method 被引量:1
12
作者 Yu ZHU Pingwei ZHOU Shengfu LI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第12期176-182,共7页
A metal-assisted method is proposed for the evaluation of gases’molecular abundance ratio in fiber-optic laser-induced breakdown spectroscopy(FO-LIBS).This method can reduce the laser ablation energy and make gas com... A metal-assisted method is proposed for the evaluation of gases’molecular abundance ratio in fiber-optic laser-induced breakdown spectroscopy(FO-LIBS).This method can reduce the laser ablation energy and make gas composition identification possible.The principle comes from the collision between the detected gases and the plasma produced by the laser ablation of the metal substrate.The interparticle collision in the plasma plume leads to gas molecules dissociating and sparking,which can be used to determine the gas composition.The quantitative relationship between spectral line intensity and molecular abundance ratio was developed over a large molecular abundance ratio range.The influence of laser ablation energy and substrate material on gas quantitative calibration measurement is also analyzed.The proposed metal-assisted method makes the measurement of gases’molecular abundance ratios possible with an FO-LIBS system. 展开更多
关键词 gases’molecular abundance ratio collision of plasma fiber optical laser induced breakdown spectroscopy metal assisted method
下载PDF
A comparison of single shot nanosecond and femtosecond polarization-resolved laser-induced breakdown spectroscopy of Al 被引量:4
13
作者 Nakimana Agnes 陶海岩 +3 位作者 郝作强 孙长凯 高勋 林景全 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期273-277,共5页
Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). Th... Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). The main specific features of fs-PRLIBS are that a lower plasma temperature leads to a low level of continuum and no species are detected from the ambient gas. Furthermore, signals obtained by fs-PRLIBS show a higher stability than those of ns-PRLIBS. However, more elements are detected in the ns-PRLIBS spectra. 展开更多
关键词 polarization-resolved laser-induced breakdown spectroscopy femtosecond laser nanosecond laser SHIELDING
下载PDF
Improvement of quantitative analysis of molybdenum element using PLS-based approaches for laser-induced breakdown spectroscopy in various pressure environments 被引量:3
14
作者 Jiamin LIU Ding WU +4 位作者 Cailong FU Ran HAI Xiao YU Liying SUN Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期140-147,共8页
An experimental setup has been designed and realized in order to optimize the characteristics of laser-induced breakdown spectroscopy system working in various pressure environments. An approach combined the normaliza... An experimental setup has been designed and realized in order to optimize the characteristics of laser-induced breakdown spectroscopy system working in various pressure environments. An approach combined the normalization methods with the partial least squares(PLS) method are developed for quantitative analysis of molybdenum(Mo) element in the multi-component alloy,which is the first wall material in the Experimental Advanced Superconducting Tokamak. In this study, the different spectral normalization methods(total spectral area normalization,background normalization, and reference line normalization) are investigated for reducing the uncertainty and improving the accuracy of spectral measurement. The results indicates that the approach of PLS based on inter-element interference is significantly better than the conventional PLS methods as well as the univariate linear methods in the various pressure for molybdenum element analysis. 展开更多
关键词 laser induced breakdown spectroscopy MOLYBDENUM VACUUM NORMALIZATION partial least SQUARES method quantitative analysis
下载PDF
Spectral Enhancement of Laser-Induced Breakdown Spectroscopy in External Magnetic Field 被引量:4
15
作者 李丞 高勋 +2 位作者 李奇 宋超 林景全 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期919-922,共4页
In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spec... In this paper the spectral enhancement of laser-induced breakdown spectroscopy (LIBS) for copper plasma in the presence of a magnetic field is investigated and the temporal- and spatial-resolved plasma emission spectra are analyzed. Experimental results show that the copper plasma atomic and ion spectra have been enhanced in the presence of the external magnetic field. In addition, the Cu I 521.82 nm spectral intensity evolution with delay time appears to have a double peak around the delay time of 2 μs, but that of Cu II 507.57 nm has a sharp decrease because of the electron-atom three body recombination process. The plasma temperature with magnetic confinement is lower than that of the case in the absence of magnetic fields. Finally, the spectral enhancement mechanisms of laser induced breakdown spectroscopy with magnetic confinement are analyzed. 展开更多
关键词 laser induced breakdown spectroscopy spectral enhancement magnetic confinement
下载PDF
Quantitative analysis of C, Si, Mn, Ni, Cr and Cu in low-alloy steel under ambient conditions via laser-induced breakdown spectroscopy 被引量:4
16
作者 Dan LUO Ying LIU +3 位作者 Xiangyu LI Zhenyang ZHAO Shigong WANG Yong ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期152-158,共7页
A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors,... A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors, such as laser pulse energy, repetition rate and argon flow rate, that influence laser-induced breakdown spectroscopy (LIBS) analytical performance are investigated in detail. Under the optimal experiment conditions, the relative standard deviations for C, Si, Mn, Ni, Cr and Cu are 3.3%-8.9%, 0.9%-2.8%, 1.2%-4.1%, 1.7%-3.0%, 1.1%-3.4% and 2.5%-8.5%, respectively, with the corresponding relative errors of 1.1%-7.9%, 1.0%-6.3%, 0.4%-3.9%, 1.5%-6.3%, 1.2%-4.0% and 1.2%-6.4%. Compared with the results of the traditional spark discharge optical emission spectrometry technique, the analytical performance of LIBS is just a little inferior due to the less stable laser-induced plasma and smaller amount of ablated sample by the laser. However, the precision, detection limits and accuracy of LIBS obtained in our present work were sufficient to meet the requirements for process analysis. These technical performances of higher stability of output energy and longer service life for DPSSL, in comparison to the Q-switch laser pumped by xeon lamp, qualify it well for the real time online analysis for different industrial applications. 展开更多
关键词 laser-induced breakdown spectroscopy (LIBS) diode-pumped solid-state laser(DPSSL) optical emission spectrometry laser-induced plasma
下载PDF
Detection of heavy metals in water samples by laser-induced breakdown spectroscopy combined with annular groove graphite flakes 被引量:6
17
作者 Li FANG Nanjing ZHAO +5 位作者 Mingjun MA Deshuo MENG Yao JIA Xingjiu HUANG Wenqing LIU Jianguo LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期16-22,共7页
The use of laser-induced breakdown spectroscopy(LIBS) for the analysis of heavy metals in water samples is investigated. Some factors such as splashing, surface ripples, extinction of emitted intensity, and a shorter ... The use of laser-induced breakdown spectroscopy(LIBS) for the analysis of heavy metals in water samples is investigated. Some factors such as splashing, surface ripples, extinction of emitted intensity, and a shorter plasma lifetime will influence the results if the water sample is directly measured. In order to avoid these disadvantages and the ‘coffee-ring effect', hydrophilic graphite flakes with annular grooves were used for the first time to enrich and concentrate heavy metals in water samples before being analyzed by LIBS. The proposed method and procedure have been evaluated to concentrate and analyze cadmium, chromium, copper, nickel, lead,and zinc in a water sample. The correlation coefficients were all above 0.99. The detection limits of 0.029, 0.087, 0.012, 0.083, 0.125, and 0.049 mgl^(-1) for Cd, Cr, Cu, Ni, Pb, and Zn,respectively, were obtained in samples prepared in a laboratory. With this structure, the heavy metals homogeneously distribute in the annular groove and the relative standard deviations are all below 6%. This method is very convenient and suitable for online in situ analysis of heavy metals. 展开更多
关键词 laser-induced breakdown spectroscopy quantitative analysis heavy metals GRAPHITE FLAKE
下载PDF
Signal processing for real-time identification of similar metals by laser-induced breakdown spectroscopy 被引量:6
18
作者 Sungho SHIN Youngmin MOON +3 位作者 Jaepil LEE Hyemin JANG Euiseok HWANG Sungho JEONG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期84-91,共8页
Laser-induced breakdown spectroscopy(LIBS) is regarded as a promising technique for realtime sorting of scrap metals due to its capability of fast multi-elemental and in-air analysis. This work reports a method for si... Laser-induced breakdown spectroscopy(LIBS) is regarded as a promising technique for realtime sorting of scrap metals due to its capability of fast multi-elemental and in-air analysis. This work reports a method for signal processing which ensures high accuracy and high speed during similar metal sorting by LIBS. Similar metals such as aluminum alloys or stainless steel are characterized by nearly the same constituent elements with slight variations in elemental concentration depending on metal type. In the proposed method, the original data matrix is substantially reduced for fast processing by selecting new input variables(spectral lines) using the information for the constituent elements of similar metals. Specifically, principal component analysis(PCA) of full-spectra LIBS data was performed and then, based on the loading plots, the input variables of greater significance were selected in the order of higher weights for each constituent element. The results for the classification test with aluminum alloy, copper alloy,stainless steel and cast steel showed that the classification accuracy of the proposed method was nearly the same as that of full-spectra PCA, but the computation time was reduced by a factor of 20 or more. The results demonstrated that incorporating the information for constituent elements can significantly accelerate classification speed without loss of accuracy. 展开更多
关键词 laser-induced breakdown spectroscopy classification similar metal REDUCED number of SPECTRAL LINES
下载PDF
Analysis of Pulverized Coal by Laser-Induced Breakdown Spectroscopy 被引量:8
19
作者 余亮英 陆继东 +3 位作者 陈文 吴戈 沈凯 冯伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3041-3044,共4页
Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LI... Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LIBS, and the effects of particle size are analyzed. A powerful pulse Nd:YAG laser is focused on the coal sample at atmosphere pressure, and the emission spectra from laser-induced plasmas are measured by time-resolved spectroscopy, and the intensity of analyzed spectral lines is obtained through observing the laser plasma with a delay time of 0.4 #s. The experimental results show that the slope of calibration curve is nearly 1 when the concentration of the analyzed element is relatively low, and the slope of curve is nearly 0.5 when the concentration of C is higher than other elements. In addition, using the calibration-free model without self-absorption effect, the results show that the decreasing of particle size leads to an increase of the plasma temperature. 展开更多
关键词 laser-induced breakdown spectroscopy element analysis SELF-ABSORPTION delay time
下载PDF
Laser Induced Breakdown Spectroscopy for Comparative Quantitative Analysis of Betel Leaves from Pakistan 被引量:1
20
作者 I Rehan K Rehan +1 位作者 S Sultana R Muhammad 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2018年第10期3295-3302,共8页
Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean ... Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products. 展开更多
关键词 laser induced breakdown spectroscopy(LIBS) Spectral analysis Inductively coupled plasma-optical emission SPECTROMETRY Limit of detection(LOD)
下载PDF
上一页 1 2 70 下一页 到第
使用帮助 返回顶部