期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Real-Time Dynamic Spectrum Analysis for Plasma Electron Density and Faraday Rotation Angle Measurement on HL-2A
1
作者 丁宝钢 吴军 +3 位作者 范伟伟 吴彤宇 周艳 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第12期1092-1096,共5页
Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the f... Electron density and Faraday rotation angle are important physical parameters in nuclear fusion research.To measure them simultaneously,the three-wave polarimeter/interferometer diagnostic system is applied.Both the final probe output signal and the reference signal contain three frequency components.The time-varying phase difference curve of each frequency component can be measured by the Real-time Dynamic Spectrum Analysis(RDSA)method based on Field-Programmable Gate Array(FPGA).The phase difference precision is better than 0.1° and the real-time feedback delay is less than 1 ms,which satisfy the requirements of HL-2A. 展开更多
关键词 Electron spectrum Faraday rotation interferometer satisfy performing Angle instead rotating
下载PDF
超高效液相色谱串联四极杆质谱联用分析番茄酱中苏丹红Ⅰ~Ⅳ含量 被引量:5
2
作者 孙姝琦 田毅敏 杜振霞 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期225-227,共3页
The method of simultaneous analysis of Sudan Red Ⅰ-Ⅳ residues in ketchup was developed with an ultra performance liquid chromatography-tandem mass spectrum.Acetonitrile was used to extract the substance from the ket... The method of simultaneous analysis of Sudan Red Ⅰ-Ⅳ residues in ketchup was developed with an ultra performance liquid chromatography-tandem mass spectrum.Acetonitrile was used to extract the substance from the ketchup,and the upper layer was detected by the UPLC-MS/MS after refrigeration and centrifuge.The sample was separated on a Waters Acquity BHE C18 column,and detected by the MRM mode of the mass spectrum.The LOD was 2 ng/mL and the LOQ was 5 ng/mL all of the four substances.The average recoveries were between 67.42%-84.59% of the 100,200,300 μg/kg three spiked concentration levels and the RSD values were between 2.87%-9.57%. 展开更多
关键词 Sudan Red Ⅰ-Ⅳ KETCHUP Ultra performance liquid chromatography-tandem mass spectrum
下载PDF
超高效液相色谱串联四极杆质谱联用分析动物血样中乌头类生物碱 被引量:5
3
作者 杜振霞 孙姝琦 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期61-63,共3页
An ultra performance liquid chromatography-tandem mass spectrum method has been developed for the determination of three aconitum alkaloids (aconitine,hypaconitine and mesaconitine).The three alkaloids were analyzed s... An ultra performance liquid chromatography-tandem mass spectrum method has been developed for the determination of three aconitum alkaloids (aconitine,hypaconitine and mesaconitine).The three alkaloids were analyzed simultaneously with an Waters Acquity BHE C18 column by gradient elution using 0.05% aqueous ammonia-acetonitrile as mobile phase and detected by the MRM mode of the mass spectrum.The recoveries of the SPE method were between 68.79%-95.65% (RSD<7.94%,n=4),and all the alkaloids showed good linearity (r>0.998) in a relatively wide concentration range.The LOD reached 0.0516,0.0640,0.0744 ng/mL of aconitine,hypaconitine and mesaconitine,respectively.The analysis time was within 3 min which could meet the high-throughput detection.The results indicated that contents of alkaloids in animal blood can be well detected;and this method can be used in quality control of aconitum drugs and pharmacokinetics study. 展开更多
关键词 ACONITINE HYPACONITINE MESACONITINE Animal blood Ultra performance liquid chromatography-tandem mass spectrum
下载PDF
A theoretical method based on Fourier spectrum analysis for the focusing performances of the X-ray compound refractive lenses 被引量:1
4
作者 叶坚 乐孜纯 +4 位作者 梁静秋 刘恺 全必胜 覃亚丽 朱广信 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第6期367-369,共3页
It is important to predict the intensity distribution in focusing plane for designing the X-ray compound refractive lenses. On the basis of analyzing the structure of X-ray compound lenses and comparing it with Praunh... It is important to predict the intensity distribution in focusing plane for designing the X-ray compound refractive lenses. On the basis of analyzing the structure of X-ray compound lenses and comparing it with Praunhofer diffraction system, it is concluded that the X-ray focusing system can be regarded as a kind of Praunhofer diffraction system. Therefore, a method based on Fourier spectrum analysis is presented to predict the intensity distribution in the focusing plane for the X-ray lenses. A brief analysis on the relationship between the parameters of X-ray lenses and their focusing performance is also given in this paper. 展开更多
关键词 A theoretical method based on Fourier spectrum analysis for the focusing performances of the X-ray compound refractive lenses
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部