Lumbar spondylolysis is a relatively common condition that can cause a variety of clinical manifestations related to the lumbar spine. However, multi-level lumbar spondylolysis is rare and accounts for less than 6% of...Lumbar spondylolysis is a relatively common condition that can cause a variety of clinical manifestations related to the lumbar spine. However, multi-level lumbar spondylolysis is rare and accounts for less than 6% of lumbar spondylolysis. We report a case of three-level lumbar spondylolysis with single-level spondylolisthesis. A 47-year-old woman presented to us with low back pain for 9 years that progressively worsened and the pain was exacerbated with standing and walking. She was diagnosed with three-level lumbar spondylolysis at L3-5 and spondylolisthesis at L4. We performed posterolateral lumber fusion (PLF) and posterior lumbar interbody fusion (PLIF) surgery for her. During the same period, pain recovery and fusion rate of the patient were evaluated after surgery. The results were favorable and proved the efficacy of combining PLF and PLIF technique for treatment for three-level lumbar spondylolysis and single-level spondylolisthesis.展开更多
Four-level lumbar spondylolysis is extremely rare.So far,only 1 case has been reported in the literature.CASE SUMMARY A 19-year-old man presented with severe back pain irresponsive to conservative therapies for 2 year...Four-level lumbar spondylolysis is extremely rare.So far,only 1 case has been reported in the literature.CASE SUMMARY A 19-year-old man presented with severe back pain irresponsive to conservative therapies for 2 years.Lumbar radiographs and two-dimensional computed tomography scan showed four segment lumbar spondylolysis on both sides of L2-L5.Lumbar magnetic resonance imaging showed normal signal in all lumbar discs.Because daily activities were severely limited,surgery was recommended for the case.The patient underwent four-level bilateral isthmic repair at L2-L5.During surgery,L2-L5 isthmi were curetted bilaterally,freshened,and then grafted with autologous iliac bone that was bridged and compressed with a pedicular screw connected to a sub-laminar hook by a short rod.The symptoms of back pain almost disappeared.He has been followed-up for 96 mo,and his symptoms have never recurred.Fusion was found in all repaired isthmi 14 mo after surgery according to evaluation of lumbar radiography and computed tomography scan.CONCLUSION We report here 1 case of four-level lumbar spondylolysis that was treated successfully with direct isthmic repair.展开更多
BACKGROUND The pedicle screw-laminar hook system has strong fixation and is conducive to bone graft fusion for lumbar spondylolysis.However,the current pedicle screwlaminar hook fixation system is not specifically des...BACKGROUND The pedicle screw-laminar hook system has strong fixation and is conducive to bone graft fusion for lumbar spondylolysis.However,the current pedicle screwlaminar hook fixation system is not specifically designed for lumbar spondylolysis.AIM To investigate the clinical effects of a new anatomical hook-rod-pedicle screw system in the treatment of lumbar spondylolysis in young adults.METHODS We designed a new anatomic hook-rod-pedicle screw system for young patients with lumbar spondylolysis.The isthmus and the corresponding pedicle screw entry point were exposed through the intermuscular approach.Autogenous iliac bone graft was obtained to bridge the isthmus defect,and then the anatomic hook-rod-pedicle screw system was used to fix the isthmus in 15 young patients.RESULTS At 24 mo follow-up,the visual analogue scale score of low back pain decreased from 6.73±0.88 to 0.73±0.59,and the Oswestry disability index score decreased from 58.20±8.99 to 7.87±4.97.Computed tomography showed bilateral isthmic bone healing in 14 cases and unilateral isthmic bone healing in 1 case.Magnetic resonance imaging showed that the lumbar disc signal of diseased segment and adjacent segments had no change compared with that before surgery.The pain visual analogue scale score of the donor site was 0.20±0.41 at the last follow-up.According to the Modified Macnab score,the excellent and good rate was 100%.CONCLUSION The application of this new anatomical hook-rod-pedicle screw system to treat young patients with lumbar spondylolysis has the advantages of less trauma,a simple operation and satisfactory clinical effects.展开更多
Bone fractures can be detected by analyzing vibration signals following bone stimulation. This method can also be applied to detect stress fractures, such as spondylolysis. The aim of this study was to investigate whe...Bone fractures can be detected by analyzing vibration signals following bone stimulation. This method can also be applied to detect stress fractures, such as spondylolysis. The aim of this study was to investigate whether vibration signal analysis can be used to detect lumbar spondylolysis in synthetic bone. Four synthetic spondylolysis models of the fifth lumbar vertebra (Sawbones, product No. SAW1352-10: Malmö, Sweden) were prepared, with the following conditions: intact, unilateral defect, and bilateral defect. Unilateral defects were created by making an incision of either half the diameter (50% incision) or the entire diameter (100% incision) in length through the pars interarticularis or pedicle. Bilateral defects were created by making an additional incision of half the diameter in length on the opposite side of the defected pars interarticularis or pedicle (50% + 100% incision). Hammering was performed five times on each spinous process of the fixed synthetic bones and vibration signals were measured using an accelerometer attached to the contralateral side of the hammer. Signals were analyzed using fast Fourier transform. The parameters analyzed included the mean power frequency, first power minimum frequency (the minimum value between the first and second peaks), spectral areas of low and high frequency bands, and the relative ratio between the spectral areas of low and high frequency bands. The relative ratio was significantly lower in the 50%, 100%, and 50% + 100% incision conditions compared to the intact condition (p < 0.01), suggesting the potential utility of vibration signal analysis in diagnosing lumbar spondylolysis.展开更多
AIM:To clarify the efficacy of conservative and surgical treatment of spondylolysis in athletes.METHODS:PubMed was used to perform a search of the literature for studies published during the period from 1990 to 2009 t...AIM:To clarify the efficacy of conservative and surgical treatment of spondylolysis in athletes.METHODS:PubMed was used to perform a search of the literature for studies published during the period from 1990 to 2009 that reported data on the outcome of conservative or surgical treatment of spondylolysis in athletes.The articles were examined for data on the percentage of athletes who returned to sports activities and the interval between the start of treatment and their return.RESULTS:Five studies were identified.Two studies were concerned with conservative treatment and the other three with surgical treatment(wire fixation or screw fixation with bone graft).The percentages of athletes who returned to sports activities ranged from 80.0%to 89.3%and from 81.9%to 100%,respectively,and the intervals until their return ranged from 5.4 to 5.5 mo and from 7 to 12 mo,respectively.CONCLUSION:The percentages of athletes who returned to sports activities after conservative and surgical treatment appeared to be satisfactory,but the展开更多
Innovative pulsed current-assisted multi-pass rolling tests were conducted on a 12-roll mill during the rolling deformation processing of SUS304 ultra-thin strips.The results show that in the first rolling pass,the ro...Innovative pulsed current-assisted multi-pass rolling tests were conducted on a 12-roll mill during the rolling deformation processing of SUS304 ultra-thin strips.The results show that in the first rolling pass,the rolling reduction rate of a conventionally rolled sample(at room temperature)is 33.8%,which can be increased to 41.5%by pulsed current-assisted rolling,enabling the formation of an ultra-thin strip with a size of 67.3μm in only one rolling pass.After three passes of pulsed current-assisted rolling,the thickness of the ultra-thin strip can be further reduced to 51.7μm.To clearly compare the effects of a pulsed current on the microstructure and mechanical response of the ultra-thin strip,ultra-thin strips with nearly the same thickness reduction were analyzed.It was found that pulsed current can reduce the degree of work-hardening of the rolled samples by promoting dislocation detachment,reducing the density of stacking faults,inhibiting martensitic phase transformation,and shortening the total length of grain boundaries.As a result,the ductility of ultra-thin strips can be effectively restored to approximately 16.3%while maintaining a high tensile strength of 1118 MPa.Therefore,pulsed current-assisted rolling deformation shows great potential for the formation of ultra-thin strips with a combination of high strength and ductility.展开更多
Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with ...Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with multi-segment lumbar spondylolysis were selected in our hospital.According to different surgical schemes,these patients were divided into the observation group(35 cases)and the control group(35 cases).The observation group received pedicle screw fixation combined with cable wires and bone graft and the control group received cannulated compression screw fixation.Macnab criteria were adopted to implement a therapeutic evaluation of two groups of patients to make an observation and comparison of the excellent and good rate of surgery and a series of indicators including perioperative clinical effects,intraoperative blood loss,duration of surgery,hospital length of stay(HLOS),visual analogue scale(VAS),Oswestry disability index and Japanese Orthopaedic Association(JOA)score.Results:The excellent and good rate of the observation group was 97.14%,and that of the control group was 82.86%,the difference between two groups was statistically significant(χ^(2)=6.248,p=0.012).The differences in intraoperative blood loss,duration of surgery and HLOS between two groups were statistically significant(t=-4.55,t=-4.55,t=-4.55;p<0.05).Oswestry index,VAS score and JOA score of the observation group were(2.4±0.9),(28.5±6.4)and(27.1±3.1)respectively,and these of the control group were(3.5±1.2),(37.1±7.8)and(21.3±2.7)respectively,the differences between two groups were statistically significant(t=4.338,t=5.043,t=8.347,p<0.05).Conclusions:Pedicle screw combined with immobilized implantation bone by wirerope has an excellent clinical effect on the treatment of adult multi-segment lumbar spondylolysis,and it has a series of advantages such as fast postoperative recovery,small surgical trauma and so on.In addition,this technique can also restore the stability of spinal segments and relieve pains to a greater degree.展开更多
This paper describes an extension and a new foundation of the Standard Model of particle physics based on a SU(4)-force called hyper-color, and on preon subparticles. The hyper-color force is a generalization of the S...This paper describes an extension and a new foundation of the Standard Model of particle physics based on a SU(4)-force called hyper-color, and on preon subparticles. The hyper-color force is a generalization of the SU(2)-based weak interaction and the SU(1)-based right-chiral self-interaction, in which the W-and the Z-bosons are Yukawa residual-field-carriers of the hyper-color force, in the same sense as the pions are the residual-field-carriers of the color SU(3) interaction. Using the method of numerical minimization of the SU(4)-action based on this model, the masses and the inner structure of leptons, quarks and weak bosons are calculated: the mass results are very close to the experimental values. We calculate also precisely the value of the Cabibbo angle, so the mixing matrices of the Standard model, CKM matrix for quarks and PMNS matrix for neutrinos can also be calculated. In total, we reduce the 29 parameters of the Standard Model to a total of 7 parameters.展开更多
文摘Lumbar spondylolysis is a relatively common condition that can cause a variety of clinical manifestations related to the lumbar spine. However, multi-level lumbar spondylolysis is rare and accounts for less than 6% of lumbar spondylolysis. We report a case of three-level lumbar spondylolysis with single-level spondylolisthesis. A 47-year-old woman presented to us with low back pain for 9 years that progressively worsened and the pain was exacerbated with standing and walking. She was diagnosed with three-level lumbar spondylolysis at L3-5 and spondylolisthesis at L4. We performed posterolateral lumber fusion (PLF) and posterior lumbar interbody fusion (PLIF) surgery for her. During the same period, pain recovery and fusion rate of the patient were evaluated after surgery. The results were favorable and proved the efficacy of combining PLF and PLIF technique for treatment for three-level lumbar spondylolysis and single-level spondylolisthesis.
文摘Four-level lumbar spondylolysis is extremely rare.So far,only 1 case has been reported in the literature.CASE SUMMARY A 19-year-old man presented with severe back pain irresponsive to conservative therapies for 2 years.Lumbar radiographs and two-dimensional computed tomography scan showed four segment lumbar spondylolysis on both sides of L2-L5.Lumbar magnetic resonance imaging showed normal signal in all lumbar discs.Because daily activities were severely limited,surgery was recommended for the case.The patient underwent four-level bilateral isthmic repair at L2-L5.During surgery,L2-L5 isthmi were curetted bilaterally,freshened,and then grafted with autologous iliac bone that was bridged and compressed with a pedicular screw connected to a sub-laminar hook by a short rod.The symptoms of back pain almost disappeared.He has been followed-up for 96 mo,and his symptoms have never recurred.Fusion was found in all repaired isthmi 14 mo after surgery according to evaluation of lumbar radiography and computed tomography scan.CONCLUSION We report here 1 case of four-level lumbar spondylolysis that was treated successfully with direct isthmic repair.
文摘BACKGROUND The pedicle screw-laminar hook system has strong fixation and is conducive to bone graft fusion for lumbar spondylolysis.However,the current pedicle screwlaminar hook fixation system is not specifically designed for lumbar spondylolysis.AIM To investigate the clinical effects of a new anatomical hook-rod-pedicle screw system in the treatment of lumbar spondylolysis in young adults.METHODS We designed a new anatomic hook-rod-pedicle screw system for young patients with lumbar spondylolysis.The isthmus and the corresponding pedicle screw entry point were exposed through the intermuscular approach.Autogenous iliac bone graft was obtained to bridge the isthmus defect,and then the anatomic hook-rod-pedicle screw system was used to fix the isthmus in 15 young patients.RESULTS At 24 mo follow-up,the visual analogue scale score of low back pain decreased from 6.73±0.88 to 0.73±0.59,and the Oswestry disability index score decreased from 58.20±8.99 to 7.87±4.97.Computed tomography showed bilateral isthmic bone healing in 14 cases and unilateral isthmic bone healing in 1 case.Magnetic resonance imaging showed that the lumbar disc signal of diseased segment and adjacent segments had no change compared with that before surgery.The pain visual analogue scale score of the donor site was 0.20±0.41 at the last follow-up.According to the Modified Macnab score,the excellent and good rate was 100%.CONCLUSION The application of this new anatomical hook-rod-pedicle screw system to treat young patients with lumbar spondylolysis has the advantages of less trauma,a simple operation and satisfactory clinical effects.
文摘Bone fractures can be detected by analyzing vibration signals following bone stimulation. This method can also be applied to detect stress fractures, such as spondylolysis. The aim of this study was to investigate whether vibration signal analysis can be used to detect lumbar spondylolysis in synthetic bone. Four synthetic spondylolysis models of the fifth lumbar vertebra (Sawbones, product No. SAW1352-10: Malmö, Sweden) were prepared, with the following conditions: intact, unilateral defect, and bilateral defect. Unilateral defects were created by making an incision of either half the diameter (50% incision) or the entire diameter (100% incision) in length through the pars interarticularis or pedicle. Bilateral defects were created by making an additional incision of half the diameter in length on the opposite side of the defected pars interarticularis or pedicle (50% + 100% incision). Hammering was performed five times on each spinous process of the fixed synthetic bones and vibration signals were measured using an accelerometer attached to the contralateral side of the hammer. Signals were analyzed using fast Fourier transform. The parameters analyzed included the mean power frequency, first power minimum frequency (the minimum value between the first and second peaks), spectral areas of low and high frequency bands, and the relative ratio between the spectral areas of low and high frequency bands. The relative ratio was significantly lower in the 50%, 100%, and 50% + 100% incision conditions compared to the intact condition (p < 0.01), suggesting the potential utility of vibration signal analysis in diagnosing lumbar spondylolysis.
文摘AIM:To clarify the efficacy of conservative and surgical treatment of spondylolysis in athletes.METHODS:PubMed was used to perform a search of the literature for studies published during the period from 1990 to 2009 that reported data on the outcome of conservative or surgical treatment of spondylolysis in athletes.The articles were examined for data on the percentage of athletes who returned to sports activities and the interval between the start of treatment and their return.RESULTS:Five studies were identified.Two studies were concerned with conservative treatment and the other three with surgical treatment(wire fixation or screw fixation with bone graft).The percentages of athletes who returned to sports activities ranged from 80.0%to 89.3%and from 81.9%to 100%,respectively,and the intervals until their return ranged from 5.4 to 5.5 mo and from 7 to 12 mo,respectively.CONCLUSION:The percentages of athletes who returned to sports activities after conservative and surgical treatment appeared to be satisfactory,but the
基金This work was supported by the fund of the National Natural Science Foundation of China(51974196)Major Program of National Natural Science Foundation of China(U22A20188)+1 种基金Science and Technology Innovation Teams of Shanxi Province(202304051001025)Central Government Guides the Special Fund Projects of Local Scientific and Technological Development(YDZX20191400002149).
文摘Innovative pulsed current-assisted multi-pass rolling tests were conducted on a 12-roll mill during the rolling deformation processing of SUS304 ultra-thin strips.The results show that in the first rolling pass,the rolling reduction rate of a conventionally rolled sample(at room temperature)is 33.8%,which can be increased to 41.5%by pulsed current-assisted rolling,enabling the formation of an ultra-thin strip with a size of 67.3μm in only one rolling pass.After three passes of pulsed current-assisted rolling,the thickness of the ultra-thin strip can be further reduced to 51.7μm.To clearly compare the effects of a pulsed current on the microstructure and mechanical response of the ultra-thin strip,ultra-thin strips with nearly the same thickness reduction were analyzed.It was found that pulsed current can reduce the degree of work-hardening of the rolled samples by promoting dislocation detachment,reducing the density of stacking faults,inhibiting martensitic phase transformation,and shortening the total length of grain boundaries.As a result,the ductility of ultra-thin strips can be effectively restored to approximately 16.3%while maintaining a high tensile strength of 1118 MPa.Therefore,pulsed current-assisted rolling deformation shows great potential for the formation of ultra-thin strips with a combination of high strength and ductility.
文摘Objective:To observe clinical effects of pedicle screw fixation combined with cable wires and bone graft and cannulated compression screws on adult multi-segment lumbar spondylolysis.Methods:70 cases of patients with multi-segment lumbar spondylolysis were selected in our hospital.According to different surgical schemes,these patients were divided into the observation group(35 cases)and the control group(35 cases).The observation group received pedicle screw fixation combined with cable wires and bone graft and the control group received cannulated compression screw fixation.Macnab criteria were adopted to implement a therapeutic evaluation of two groups of patients to make an observation and comparison of the excellent and good rate of surgery and a series of indicators including perioperative clinical effects,intraoperative blood loss,duration of surgery,hospital length of stay(HLOS),visual analogue scale(VAS),Oswestry disability index and Japanese Orthopaedic Association(JOA)score.Results:The excellent and good rate of the observation group was 97.14%,and that of the control group was 82.86%,the difference between two groups was statistically significant(χ^(2)=6.248,p=0.012).The differences in intraoperative blood loss,duration of surgery and HLOS between two groups were statistically significant(t=-4.55,t=-4.55,t=-4.55;p<0.05).Oswestry index,VAS score and JOA score of the observation group were(2.4±0.9),(28.5±6.4)and(27.1±3.1)respectively,and these of the control group were(3.5±1.2),(37.1±7.8)and(21.3±2.7)respectively,the differences between two groups were statistically significant(t=4.338,t=5.043,t=8.347,p<0.05).Conclusions:Pedicle screw combined with immobilized implantation bone by wirerope has an excellent clinical effect on the treatment of adult multi-segment lumbar spondylolysis,and it has a series of advantages such as fast postoperative recovery,small surgical trauma and so on.In addition,this technique can also restore the stability of spinal segments and relieve pains to a greater degree.
文摘This paper describes an extension and a new foundation of the Standard Model of particle physics based on a SU(4)-force called hyper-color, and on preon subparticles. The hyper-color force is a generalization of the SU(2)-based weak interaction and the SU(1)-based right-chiral self-interaction, in which the W-and the Z-bosons are Yukawa residual-field-carriers of the hyper-color force, in the same sense as the pions are the residual-field-carriers of the color SU(3) interaction. Using the method of numerical minimization of the SU(4)-action based on this model, the masses and the inner structure of leptons, quarks and weak bosons are calculated: the mass results are very close to the experimental values. We calculate also precisely the value of the Cabibbo angle, so the mixing matrices of the Standard model, CKM matrix for quarks and PMNS matrix for neutrinos can also be calculated. In total, we reduce the 29 parameters of the Standard Model to a total of 7 parameters.