Objective:To investigate the clinical diagnostic significance of peripheral blood T-cell test(T-spot test)for tuberculosis(TB)infection combined with erythrocyte sedimentation rate(ESR)in pulmonary TB.Methods:41 patie...Objective:To investigate the clinical diagnostic significance of peripheral blood T-cell test(T-spot test)for tuberculosis(TB)infection combined with erythrocyte sedimentation rate(ESR)in pulmonary TB.Methods:41 patients with a clinical diagnosis of TB during hospitalization from January 2020 to April 2023 in our hospital were selected as the experimental group,and 45 patients without TB(bronchopneumonia patients)were selected as the control group.The diagnostic specificity,sensitivity,and accuracy of the T-spot TB test,ESR test,and the combined test of the two were calculated respectively.Results:The sensitivity,specificity,and accuracy of the T-spot TB test combined with ESR for the diagnosis of TB in the experimental group were significantly higher than the individual results of the T-spot TB test and ESR test alone(P<0.05).Conclusion:The T-spot TB test combined with the ESR test for TB diagnosis has greater clinical value than carrying out the tests individually.展开更多
The interactions of p-dimethylaminobenzaldehyde(p-DAB) and potassium hydrogen sulphate(PHS) in equimolar ratio with various concentration of diphenylamine(solid test material) have been investigated by capillary spot-...The interactions of p-dimethylaminobenzaldehyde(p-DAB) and potassium hydrogen sulphate(PHS) in equimolar ratio with various concentration of diphenylamine(solid test material) have been investigated by capillary spot-tests technique in order to investigate the effect of temperature and volume of material in test-tube.The formation of the colored boundary in the capillary is taken for the detection of organic compounds by spot-tests at different temperature and volume of solid test material.展开更多
In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan imag...In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan image generated cannot be used to assess spot welding quality reliably. Based on bicubic image interpolation, the C-scan image in low resolution with the large step length 1 000 ~xm is subdivided and reconstructed. By this means, the C-scan image resolution is greatly enhanced and testing results obtained are satisfactory, realizing rapid assessment of spot welds. The results of rapid ultrasonic C-scan test fit the actual metallographic measured value well. Mean value of normal distribution of error statistics is O. 006 67, and the standard deviation is O. 087 11. Rapid ultrasonic C-scan test based on image interpolation is of high accuracy and excellent stability.展开更多
文摘Objective:To investigate the clinical diagnostic significance of peripheral blood T-cell test(T-spot test)for tuberculosis(TB)infection combined with erythrocyte sedimentation rate(ESR)in pulmonary TB.Methods:41 patients with a clinical diagnosis of TB during hospitalization from January 2020 to April 2023 in our hospital were selected as the experimental group,and 45 patients without TB(bronchopneumonia patients)were selected as the control group.The diagnostic specificity,sensitivity,and accuracy of the T-spot TB test,ESR test,and the combined test of the two were calculated respectively.Results:The sensitivity,specificity,and accuracy of the T-spot TB test combined with ESR for the diagnosis of TB in the experimental group were significantly higher than the individual results of the T-spot TB test and ESR test alone(P<0.05).Conclusion:The T-spot TB test combined with the ESR test for TB diagnosis has greater clinical value than carrying out the tests individually.
文摘The interactions of p-dimethylaminobenzaldehyde(p-DAB) and potassium hydrogen sulphate(PHS) in equimolar ratio with various concentration of diphenylamine(solid test material) have been investigated by capillary spot-tests technique in order to investigate the effect of temperature and volume of material in test-tube.The formation of the colored boundary in the capillary is taken for the detection of organic compounds by spot-tests at different temperature and volume of solid test material.
文摘In this paper, ultrasonic C-scan test of spot welds for stainless steel has been studied. It is concluded that large scanning step length contributes to high testing efficiency, however, the low-resolution C-scan image generated cannot be used to assess spot welding quality reliably. Based on bicubic image interpolation, the C-scan image in low resolution with the large step length 1 000 ~xm is subdivided and reconstructed. By this means, the C-scan image resolution is greatly enhanced and testing results obtained are satisfactory, realizing rapid assessment of spot welds. The results of rapid ultrasonic C-scan test fit the actual metallographic measured value well. Mean value of normal distribution of error statistics is O. 006 67, and the standard deviation is O. 087 11. Rapid ultrasonic C-scan test based on image interpolation is of high accuracy and excellent stability.