The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field,as well as the synchronous parasitic torques,radial magnetic forc...The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field,as well as the synchronous parasitic torques,radial magnetic forces have been discussed in great detail in the literature,but always separately,for a long time.However,systematization of the phenomenon still awaits.Therefore,it is worth summarizing the completeness of the phenomena in a single study–with a new approach at the same time-in order to reveal the relationships between them.The role of rotor slot number is emphasized much more than before.New formulas derived for both synchronous torques and radial magnetic forces are used for further investigation.It will be shown that both phenomena in subject must be treated together.Formulas will be provided to take into account attenuation.Design guide will be provided to avoid dangerous rotor slot numbers.It will be shown that the generation of synchronous torques and radial magnetic forces do not depend–in this new approach-on the slot combination,but on the rotor slot number itself.展开更多
The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field, as well as the related differential leakage, attenuation, asynch...The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field, as well as the related differential leakage, attenuation, asynchronous parasitic torques have been discussed in great detail in the literature, but always separately, for a long time. However, systematization of the phenomenon still awaits. Therefore, it is worth summarizing the completeness of the phenomena in a single study – with a new approach at the same time-in order to reveal the relationships between them. The role of rotor slot number is emphasized much more than before. An existing, commonly used, but still impractical basic figure has been modified to more clearly demonstrate the response of the rotor for the harmonics of the stator. The need to treat differential leakage, asynchronous parasitic torques and attenuation together will be demonstrated: new formula for asynchronous parasitic torque is derived;the long-used characteristic curves for differential leakage and attenuation used separately so far was merged into one, correct curve in order to provide a correct design guide for the engineers.展开更多
Whenever a squirrel cage induction motor is started, notable electromechanical torque and current pulsations occur. The adverse effects of starting torque pulsations and high inrush current in induction motor are elim...Whenever a squirrel cage induction motor is started, notable electromechanical torque and current pulsations occur. The adverse effects of starting torque pulsations and high inrush current in induction motor are eliminated using digital power electronic soft starting schemes that guarantee higher degrees of compliance of the requirements of an ideal soft starter for the induction motor. Soft starters are cheap, simple, reliable and occupy less volume. In this paper, an experimental setup of soft starting technique with extinction angle AC voltage controller and a speed and stator current based closed loop scheme is demonstrated using Artificial Neural Network (ANN) and Fuzzy Logic Control (FLC) by the way of MATLAB/SIMULINK based simulation. The ANN based soft starting scheme produces best results in terms of smooth starting torque and least inrush current. The results thus obtained were satisfactory and promising.展开更多
To study the influence of skewed rotors and different skew angles on the losses of squirrel cage asynchronous motors,a 5.5-kW motor was taken as an example and the multi-sliced field-circuit coupled time stepping fini...To study the influence of skewed rotors and different skew angles on the losses of squirrel cage asynchronous motors,a 5.5-kW motor was taken as an example and the multi-sliced field-circuit coupled time stepping finite element method(T-S FEM)was used to analyze the axially non-uniform fundamental and harmonic field distribution characteristics at typical locations in the stator and rotor cores.The major conclusions are:firstly the skewed rotor exhibits a decrease in the harmonic copper losses caused by slot harmonic currents in the stator winding and rotor bars.Secondly,the skewed rotor shifts the non-uniform distribution of field in the axial direction,which leads to more severe saturation and an increase in iron losses.The heavier the load,the more pronounced the increase in iron losses.Furthermore,the influences of different skew angles on motor losses are studied systematically,with skew angles from 0.5 to 1.5 stator tooth pitch.It is found that the lowest total loss occurs at 0.8 stator tooth pitch,and the slot harmonics can be decreased effectively.展开更多
文摘The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field,as well as the synchronous parasitic torques,radial magnetic forces have been discussed in great detail in the literature,but always separately,for a long time.However,systematization of the phenomenon still awaits.Therefore,it is worth summarizing the completeness of the phenomena in a single study–with a new approach at the same time-in order to reveal the relationships between them.The role of rotor slot number is emphasized much more than before.New formulas derived for both synchronous torques and radial magnetic forces are used for further investigation.It will be shown that both phenomena in subject must be treated together.Formulas will be provided to take into account attenuation.Design guide will be provided to avoid dangerous rotor slot numbers.It will be shown that the generation of synchronous torques and radial magnetic forces do not depend–in this new approach-on the slot combination,but on the rotor slot number itself.
文摘The magnetic field generated in the air gap of the cage asynchronous machine and the harmonics of the magnetomotive forces creating that magnetic field, as well as the related differential leakage, attenuation, asynchronous parasitic torques have been discussed in great detail in the literature, but always separately, for a long time. However, systematization of the phenomenon still awaits. Therefore, it is worth summarizing the completeness of the phenomena in a single study – with a new approach at the same time-in order to reveal the relationships between them. The role of rotor slot number is emphasized much more than before. An existing, commonly used, but still impractical basic figure has been modified to more clearly demonstrate the response of the rotor for the harmonics of the stator. The need to treat differential leakage, asynchronous parasitic torques and attenuation together will be demonstrated: new formula for asynchronous parasitic torque is derived;the long-used characteristic curves for differential leakage and attenuation used separately so far was merged into one, correct curve in order to provide a correct design guide for the engineers.
文摘Whenever a squirrel cage induction motor is started, notable electromechanical torque and current pulsations occur. The adverse effects of starting torque pulsations and high inrush current in induction motor are eliminated using digital power electronic soft starting schemes that guarantee higher degrees of compliance of the requirements of an ideal soft starter for the induction motor. Soft starters are cheap, simple, reliable and occupy less volume. In this paper, an experimental setup of soft starting technique with extinction angle AC voltage controller and a speed and stator current based closed loop scheme is demonstrated using Artificial Neural Network (ANN) and Fuzzy Logic Control (FLC) by the way of MATLAB/SIMULINK based simulation. The ANN based soft starting scheme produces best results in terms of smooth starting torque and least inrush current. The results thus obtained were satisfactory and promising.
基金supported by the National High Technology Research and Development Program of China("863"Program)(Grant No.2009AA05Z207)
文摘To study the influence of skewed rotors and different skew angles on the losses of squirrel cage asynchronous motors,a 5.5-kW motor was taken as an example and the multi-sliced field-circuit coupled time stepping finite element method(T-S FEM)was used to analyze the axially non-uniform fundamental and harmonic field distribution characteristics at typical locations in the stator and rotor cores.The major conclusions are:firstly the skewed rotor exhibits a decrease in the harmonic copper losses caused by slot harmonic currents in the stator winding and rotor bars.Secondly,the skewed rotor shifts the non-uniform distribution of field in the axial direction,which leads to more severe saturation and an increase in iron losses.The heavier the load,the more pronounced the increase in iron losses.Furthermore,the influences of different skew angles on motor losses are studied systematically,with skew angles from 0.5 to 1.5 stator tooth pitch.It is found that the lowest total loss occurs at 0.8 stator tooth pitch,and the slot harmonics can be decreased effectively.