BACKGROUND Penoscrotal constriction devices are either used as autoerotic stimuli or to increase sexual pleasure or performance by maintaining an erection for a longer period,and a variety of metallic and non-metallic...BACKGROUND Penoscrotal constriction devices are either used as autoerotic stimuli or to increase sexual pleasure or performance by maintaining an erection for a longer period,and a variety of metallic and non-metallic objects are used.On the other hand,penile strangulation is a rare urologic emergency that requires prompt evaluation and intervention to prevent long-term complications.The goal of treating penile incarceration is to remove the foreign object as soon as possible.On the other hand,removal can be very challenging,and often requires resourcefulness and a multidisciplinary approach.CASE SUMMARY A 47-year-old man who has sex with men was transferred to our hospital for persistent phallodynia and scrotal pain,accompanying swelling due to strangulation by stainless steel rings.His medical history included acquired immunodeficiency syndrome.One day prior,he had put three stainless steel rings on his penis and scrotum before sexual intercourse.After sexual intercourse,he was unable to remove them,due to swelling of his penis and scrotum.The swelling persisted,and he felt pain in the affected area the next day,then he was transferred to our hospital by ambulance.The emergency department found that his penis and scrotum were markedly engorged and swollen.We established a diagnosis of penile and scrotal strangulation by stainless steel rings.We unsuccessfully attempted to cut the rings using a cutter,then requested a rescue team via emergency medical service.They cut through each ring in two places,using an electric-powered angle grinder,and successfully removed all of the pieces.Finally,he was discharged and went home.CONCLUSION We report the first case of penile and scrotal strangulation by stainless steel rings in an human immunodeficiency virus positive person.展开更多
The residual stresses in the wall of a SUS304 stainless steel cylindrical drawing cup were evaluated by split-ring tests, and the influences of stamping die parame- ters on the residual stress were investigated. A new...The residual stresses in the wall of a SUS304 stainless steel cylindrical drawing cup were evaluated by split-ring tests, and the influences of stamping die parame- ters on the residual stress were investigated. A new theoretical model of a split-ring test was developed to evaluate the resid- ual stress in a ring, which was verified to be reasonable and reliable by numerical simulations with ABAQUS code and by nanoindentation tests. Seven groups of split-ring tests were completed, and the residual stresses were calculated according to the theoretical model. The split-ring test results showed that the circumferential residual stress in the wall of the SUS304 stainless steel cylindrical drawing cup was very large and did not change with the different die comer radius. The circumferential residual stress first increased with the increase of drawing punch-die clearance, then was almost unchanged when the clearance increased greater than blank thickness 1 mm. Thus, a smaller clearance was suggested to be chosen to reduce the residual stress in the wall of the SUS304 stainless steel drawing cup.展开更多
Here,we report the leading manu facture of the large-scale integral weldless stainless steel forging ring(φ=15.6 m)by the multilayer additive hot-compression bonding technology.Moreover,the detailed interface healing...Here,we report the leading manu facture of the large-scale integral weldless stainless steel forging ring(φ=15.6 m)by the multilayer additive hot-compression bonding technology.Moreover,the detailed interface healing mecha nism involving interfacial oxide evolution is elucidated,which validates the feasibility and reliability of the technique we proposed.展开更多
文摘BACKGROUND Penoscrotal constriction devices are either used as autoerotic stimuli or to increase sexual pleasure or performance by maintaining an erection for a longer period,and a variety of metallic and non-metallic objects are used.On the other hand,penile strangulation is a rare urologic emergency that requires prompt evaluation and intervention to prevent long-term complications.The goal of treating penile incarceration is to remove the foreign object as soon as possible.On the other hand,removal can be very challenging,and often requires resourcefulness and a multidisciplinary approach.CASE SUMMARY A 47-year-old man who has sex with men was transferred to our hospital for persistent phallodynia and scrotal pain,accompanying swelling due to strangulation by stainless steel rings.His medical history included acquired immunodeficiency syndrome.One day prior,he had put three stainless steel rings on his penis and scrotum before sexual intercourse.After sexual intercourse,he was unable to remove them,due to swelling of his penis and scrotum.The swelling persisted,and he felt pain in the affected area the next day,then he was transferred to our hospital by ambulance.The emergency department found that his penis and scrotum were markedly engorged and swollen.We established a diagnosis of penile and scrotal strangulation by stainless steel rings.We unsuccessfully attempted to cut the rings using a cutter,then requested a rescue team via emergency medical service.They cut through each ring in two places,using an electric-powered angle grinder,and successfully removed all of the pieces.Finally,he was discharged and went home.CONCLUSION We report the first case of penile and scrotal strangulation by stainless steel rings in an human immunodeficiency virus positive person.
基金supported in part by Xiangtan University Doctoral Fund, China (Grant 12QDZ17)the Excellent Youth Program of Education Bureau of Hunan Province, China (Grant 12B124)the Key Program of Hunan Provincial Natural Science Foundation United with Xiangtan, China (Grant 13JJ8005)
文摘The residual stresses in the wall of a SUS304 stainless steel cylindrical drawing cup were evaluated by split-ring tests, and the influences of stamping die parame- ters on the residual stress were investigated. A new theoretical model of a split-ring test was developed to evaluate the resid- ual stress in a ring, which was verified to be reasonable and reliable by numerical simulations with ABAQUS code and by nanoindentation tests. Seven groups of split-ring tests were completed, and the residual stresses were calculated according to the theoretical model. The split-ring test results showed that the circumferential residual stress in the wall of the SUS304 stainless steel cylindrical drawing cup was very large and did not change with the different die comer radius. The circumferential residual stress first increased with the increase of drawing punch-die clearance, then was almost unchanged when the clearance increased greater than blank thickness 1 mm. Thus, a smaller clearance was suggested to be chosen to reduce the residual stress in the wall of the SUS304 stainless steel drawing cup.
基金supported by the National Key Research and Development Program[Grant No.2018YFA0702900]the National Natural Science Foundation of China[Grant No.51774265]+2 种基金the National Science and Technology Major Project of China[Grant No.2019ZX06004010]Program of CAS Interdisciplinary Innovation TeamYouth Innovation Promotion Association,CAS。
文摘Here,we report the leading manu facture of the large-scale integral weldless stainless steel forging ring(φ=15.6 m)by the multilayer additive hot-compression bonding technology.Moreover,the detailed interface healing mecha nism involving interfacial oxide evolution is elucidated,which validates the feasibility and reliability of the technique we proposed.