A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped...A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.展开更多
A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile...A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile (50:50, v/v) by the Agilent Kromasi NH2 column (250 mm × 4.6 mm, 5 μm, S/N: 22N25110). Detection wavelength was 201 nm. The result revealed good linearity of stachydrine hydrochloride and was obtained within the range of 0.20 - 1.98 μg/mL (R = 0.9995). The average recovery was 97.01%;the relative standard deviation (RSD) was 0.19%. To the best of our knowledge, this is the first report dedicated to the determination of stachydrine hydrochloride by the evaporative light scattering detector-high-performance liquid chromatographic (ELSD-HPLC) method.展开更多
基金Supported by National Natural Science Foundation of China(Nos.40974065 and 41025015)Scientific and Technological Innovative Team in Sichuan Province(No.2011JTD0013)"863"Program of China(No.2012AA063501)
文摘A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.
文摘A high-performance liquid chromatographic method was applied to the determination of stachydrine hydrochloride concentration in TJF granule (Chinese name: Tiao-Jing-Fang), using a mobile phase of methanol-acetonitrile (50:50, v/v) by the Agilent Kromasi NH2 column (250 mm × 4.6 mm, 5 μm, S/N: 22N25110). Detection wavelength was 201 nm. The result revealed good linearity of stachydrine hydrochloride and was obtained within the range of 0.20 - 1.98 μg/mL (R = 0.9995). The average recovery was 97.01%;the relative standard deviation (RSD) was 0.19%. To the best of our knowledge, this is the first report dedicated to the determination of stachydrine hydrochloride by the evaporative light scattering detector-high-performance liquid chromatographic (ELSD-HPLC) method.