With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possi...With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices.展开更多
文摘针对静止同步补偿器(static synchronous compensator,STATCOM)在无功补偿以及抑制电压频繁波动等场景下的优良特性,对STATCOM的V-I输出特性进行详细分析,说明其参与电压控制的原理以及和容抗器相比具有的优越性。为了增大STATCOM的无功裕度,使之有足够的能力应对电力系统可能出现的各种扰动,提出STATCOM接入系统的各种控制模式,以及在稳态电压控制模式下的无功置换策略和远方自动电压控制(automatic voltage control,AVC)模式下的无功置换优化方法。在远方AVC模式下,以STATCOM无功置换后出力最小和容抗器动作次数最少为目标函数,将容抗器投切次数作为罚函数引入到目标函数中,并讨论罚函数系数的确定方法和合理性。结果表明,该无功置换优化模型可以满足调压的同时最大限度地提升STATCOM的无功裕度,同时可以使容抗器的动作次数最少。
基金This work was supported in part by an International Research Partnership“Electrical Engineering-Thai French Research Center(EE-TFRC)”under the project framework of the Lorraine Universited’Excellence(LUE)in cooperation between Universitede Lorraine and King Mongkut’s University of Technology North Bangkok and in part by the National Research Council of Thailand(NRCT)under Senior Research Scholar Program under Grant No.N42A640328.
文摘With the daily expansion of global energy consumption,developing the power grids is of uttermost importance.However,building a new trans-mission line is costly and time-consuming,so utilizing the same lines with possible higher transmission capacity is very cost-effective.In this regard,to increase the capacity of the transmission lines,the flexible alternating current transmission system(FACTS)has been widely used in power grids in recent years by industrialized countries.One of the essential topics in electrical power systems is the reactive power compensation,and the FACTS plays a significant role in controlling the reactive power current in the power grid and the system voltage oscillations and stability.When a static synchronous compensator(STATCOM)is embedded in a power system to increase the bus voltage,a supplementary damping controller can be designed to enhance the system oscillation damping.Given the expansion of the grids in the power system,the complexity of their optimization and the extraordinary ability of the imperialist competitive algorithm(ICA)for solving such problems,in this paper,the ICA has been used to determine the optimal position and size of the FACTS devices.