An observing method for stator flux and rotor flux is presented. Based on the proposed flux observing method, a novel speed estimator has been designed. At last, the speed estimator combined with the flux observing is...An observing method for stator flux and rotor flux is presented. Based on the proposed flux observing method, a novel speed estimator has been designed. At last, the speed estimator combined with the flux observing is applied in the direct torque control system without speed sensor. The simulation results show that these methods can improve the accuracy of speed observing and the low speed performance of direct torque control system, and strengthen the robustness of system.展开更多
The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many ba...The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many basic theoretical problems that must be clarified. Thispaper describes an investigation about the effect of the zero voltage space vectors in the DTCsystem of PMSM and points out that if using the zero voltage space vectors rationally, not only canthe DTC system be driven successfully but also the torque ripple is reduced and the performance ofthe system is improved. This paper also studies the sensorless technique in the DTC system of PMSMand configures the DTC system of PMSM with sensorless technique including zero voltage spacevectors. Numerical simulations and experimental tests have proved the theory correct. In thecondition of sensor-less, the DTC system of PMSM is wide-rangely speed adjusting, and the ratio ofspeed adjustment is 1: 100.展开更多
In this paper,the fault-tolerant capability of the existing stator-flux-oriented decoupling control(SFOC)for the DTP-PM motor is investigated,and a simple fault-tolerant SFOC is further designed to enhance fault toler...In this paper,the fault-tolerant capability of the existing stator-flux-oriented decoupling control(SFOC)for the DTP-PM motor is investigated,and a simple fault-tolerant SFOC is further designed to enhance fault tolerance.Firstly,the mathematical model of the DTP-PM motor in the stator-flux-oriented rotating coordinate system is analyzed.An SFOC is proposed to guarantee healthy operation performance,considering torque,flux linkage,and harmonic currents.Secondly,the coupling relationship under open-phase conditions is assessed.The assessed result shows that the coupling relationship between the harmonic and fundamental components results in conflicts and poor post-fault operation.Thirdly,the proposed SFOC includes an automatic deactivation module to detect conflicts with a variable threshold.The conflicted harmonic current controllers can be excluded automatically.Hence,fault-tolerant control can be remedied without diagnosing the specific fault scenario,and excellent faulttolerant capability can be achieved.Finally,experiments on a DTP-PM motor are carried out to verify the feasibility and effectiveness of the proposed strategy.展开更多
The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage mod...The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage model is affected by integral initial values and integral drift,that based on current model is affected by the parameters of PMSM,so a new stator flux observation method is proposed based on an improved secondorder generalized integrator( SOGI). Compared to the stator flux observation method based on the conventional SOGI,the proposed method can not only overcome the influence of integral initial values and integral drift,but also completely eliminate the DC offset's influence. Therefore,the observation accuracy of stator flux is further improved. The simulation and experimental results both show that the proposed method has a higher stator flux and electromagnetic torque observation precision.展开更多
文摘An observing method for stator flux and rotor flux is presented. Based on the proposed flux observing method, a novel speed estimator has been designed. At last, the speed estimator combined with the flux observing is applied in the direct torque control system without speed sensor. The simulation results show that these methods can improve the accuracy of speed observing and the low speed performance of direct torque control system, and strengthen the robustness of system.
基金Aeronautical Science Emphasis foundation of China( 98Z5 2 0 0 1) Delta Power Electronics Science &Education DevelopmentF und
文摘The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many basic theoretical problems that must be clarified. Thispaper describes an investigation about the effect of the zero voltage space vectors in the DTCsystem of PMSM and points out that if using the zero voltage space vectors rationally, not only canthe DTC system be driven successfully but also the torque ripple is reduced and the performance ofthe system is improved. This paper also studies the sensorless technique in the DTC system of PMSMand configures the DTC system of PMSM with sensorless technique including zero voltage spacevectors. Numerical simulations and experimental tests have proved the theory correct. In thecondition of sensor-less, the DTC system of PMSM is wide-rangely speed adjusting, and the ratio ofspeed adjustment is 1: 100.
基金supported by the National Natural Science Foundation of China(Grant Nos.52025073 and 52107047)the Priority Academic Program Development of Jiangsu Higher Education Institutions。
文摘In this paper,the fault-tolerant capability of the existing stator-flux-oriented decoupling control(SFOC)for the DTP-PM motor is investigated,and a simple fault-tolerant SFOC is further designed to enhance fault tolerance.Firstly,the mathematical model of the DTP-PM motor in the stator-flux-oriented rotating coordinate system is analyzed.An SFOC is proposed to guarantee healthy operation performance,considering torque,flux linkage,and harmonic currents.Secondly,the coupling relationship under open-phase conditions is assessed.The assessed result shows that the coupling relationship between the harmonic and fundamental components results in conflicts and poor post-fault operation.Thirdly,the proposed SFOC includes an automatic deactivation module to detect conflicts with a variable threshold.The conflicted harmonic current controllers can be excluded automatically.Hence,fault-tolerant control can be remedied without diagnosing the specific fault scenario,and excellent faulttolerant capability can be achieved.Finally,experiments on a DTP-PM motor are carried out to verify the feasibility and effectiveness of the proposed strategy.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51377041)
文摘The stator flux and electromagnetic torque observation is the basis of direct torque controlled permanent magnet synchronous motor( PMSM) drive system. However,the traditional stator flux observer based on voltage model is affected by integral initial values and integral drift,that based on current model is affected by the parameters of PMSM,so a new stator flux observation method is proposed based on an improved secondorder generalized integrator( SOGI). Compared to the stator flux observation method based on the conventional SOGI,the proposed method can not only overcome the influence of integral initial values and integral drift,but also completely eliminate the DC offset's influence. Therefore,the observation accuracy of stator flux is further improved. The simulation and experimental results both show that the proposed method has a higher stator flux and electromagnetic torque observation precision.