The phenomenon of direct-contact condensation,used in steam driven jet injectors,nuclear reactor emergency core cooling systems and direct-contact heat exchangers,was investigated computationally by introducing a ther...The phenomenon of direct-contact condensation,used in steam driven jet injectors,nuclear reactor emergency core cooling systems and direct-contact heat exchangers,was investigated computationally by introducing a thermal equilibrium model for direct-contact condensation of steam in subcooled water.The condensation model presented was a two resistance model which takes care of the heat transfer process on both sides of the interface and uses a variable steam bubble diameter.The injection of supersonic steam jet in subcooled water tank was simulated using the Euler-Euler multiphase flow model of Fluent 6.3 code with the condensation model incorporated. The findings of the computational fluid dynamics(CFD) simulations were compared with the published experimental data and fairly good agreement was observed between the two,thus validating the condensation model.The results of CFD simulations for dimensionless penetration length of steam plume varies from 2.73-7.33,while the condensation heat transfer coefficient varies from 0.75-0.917 MW·(m ^2 ·K)^ -1 for water temperature in the range of 293-343 K.展开更多
A low mass flux steam jet in subcooled water was experimentally investigated.The transition of flow pattern from stable jet to condensation oscillation was observed at relatively high water temperature.The axial total...A low mass flux steam jet in subcooled water was experimentally investigated.The transition of flow pattern from stable jet to condensation oscillation was observed at relatively high water temperature.The axial total pressures,the axial and radial temperature distributions were measured in the jet region.The results indicated that the pressure and temperature distributions were mainly influenced by the water temperature.The correlations corrected with water temperature were given to predict the dimen-sionless axial pressure peak distance and axial temperature distributions in the jet region,the results showed a good agreement between the predictions and experiments.Moreover,the self-similarity property of the radial temperature was obtained,which agreed well with Gauss distribution.In present work,all the dimensionless properties were mainly dependent on the water temperature but weakly on the nozzle size under a certain steam mass flux.展开更多
文摘The phenomenon of direct-contact condensation,used in steam driven jet injectors,nuclear reactor emergency core cooling systems and direct-contact heat exchangers,was investigated computationally by introducing a thermal equilibrium model for direct-contact condensation of steam in subcooled water.The condensation model presented was a two resistance model which takes care of the heat transfer process on both sides of the interface and uses a variable steam bubble diameter.The injection of supersonic steam jet in subcooled water tank was simulated using the Euler-Euler multiphase flow model of Fluent 6.3 code with the condensation model incorporated. The findings of the computational fluid dynamics(CFD) simulations were compared with the published experimental data and fairly good agreement was observed between the two,thus validating the condensation model.The results of CFD simulations for dimensionless penetration length of steam plume varies from 2.73-7.33,while the condensation heat transfer coefficient varies from 0.75-0.917 MW·(m ^2 ·K)^ -1 for water temperature in the range of 293-343 K.
文摘为解决碳化硅粉碎时耗时耗力、成品粒径较大的问题,通过实验对过热蒸汽的粉碎能力进行分析,对常温空气、高温空气、过热蒸汽3种超细粉碎方式的产量与能耗进行评估。结果表明:实验系统使过热蒸汽制备的亚微米级碳化硅具有良好的粒径分布,分别调节分级机转速为1800,2700 r/min,碳化硅的粒径d50。分别为4.304、2.387μm,产量分别为12、7.2kg/h;分别改变蒸汽温度为200、300℃时,产量对应为4.9,7.2kg/h;在相同的参数条件下,使用常温空气(25℃)、高温空气(300℃)以及过热蒸汽(300℃)制备1t碳化硅粉体(d50约为4.7μm),标准煤能耗分别为2165.1、1569.4,952.9 kg.
基金Supported by the National Natural Science Foundation of China(Grant Nos.50676078,50821064)the National High-Tech Research and Development Program of China("863" Project)(Grant No.2006AA05Z230)
文摘A low mass flux steam jet in subcooled water was experimentally investigated.The transition of flow pattern from stable jet to condensation oscillation was observed at relatively high water temperature.The axial total pressures,the axial and radial temperature distributions were measured in the jet region.The results indicated that the pressure and temperature distributions were mainly influenced by the water temperature.The correlations corrected with water temperature were given to predict the dimen-sionless axial pressure peak distance and axial temperature distributions in the jet region,the results showed a good agreement between the predictions and experiments.Moreover,the self-similarity property of the radial temperature was obtained,which agreed well with Gauss distribution.In present work,all the dimensionless properties were mainly dependent on the water temperature but weakly on the nozzle size under a certain steam mass flux.