A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculate...A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculated based on this method. The results show that the accuracy of partitional and overall calculation method is almost the same, but the result is different when using different calculation models. And the results are compared with the foreign companies for 55/19 steam generator.展开更多
In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat trans...In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.展开更多
In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sint...In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sintering using a-Al203, Suzhou kaolin, talc, and feldspar as starting materials. The important parameter for solar thermal transfer tube such as water absorption (W), bulk density (Db), and the mechanical properties were investigated. The phase composition and microstructure of the composite ceramics were analyzed by XRD and SEM. The experimental results show that the B3 sintered at 1 300 ℃ and holding for 3 h has an optimum thermal shock resistance. The bending strength loss rate of B3 is only 2% at 1 100℃ by air quenching-strength test and the sample can endure 30 times thermal shock cycling, and the water absorption, the bulk density and the bending strength are 0.32%, 2.58 g·cm-3, and 125.59 MPa respectively. The XRD analysis indicated that the phase compositions of the sample were mullite, cordierite, corundum, and spinel. The SEM images illustrate that the cordierite is prismatic grain and the mullite is nano rod, showing a good thermal shock resistance for composite ceramics as potential solar thermal power material.展开更多
Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need comp...Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need complicated installation due to their fixed base;tube mobile robots suffer from low running efficiency because of their structural restricts.Since there are thousands of tubes to be checked,task planning is essential to guarantee the precise,orderly,and efficient inspection process.Most in-service robots check the task tubes using row-by-row and column-bycolumn planning.This leads to unnecessary inspections,resulting in a long shutdown and affecting the regular operation of a nuclear power plant.Therefore,this paper introduces the structure and control system of a dexterous robot and proposes a task planning method.This method proceeds into three steps:task allocation,base position search,and sequence planning.To allocate the task regions,this method calculates the tool work matrix and proposes a criterion to evaluate a sub-region.And then all tasks contained in the sub-region are considered globally to search the base positions.Lastly,we apply an improved ant colony algorithm for base sequence planning and determine the inspection orders according to the planned path.We validated the optimized algorithm by conducting task planning experiments using our robot on a tube sheet.The results show that the proposed method can accomplish full task coverage with few repetitive or redundant inspections and it increases the efficiency by 33.31% compared to the traditional planning algorithms.展开更多
Acid condensation rate is an important factor denoting the acid corrosion, and the reduction of the acid condensation can significantly relieve the acid corrosive effect on the wall surface and improve the security of...Acid condensation rate is an important factor denoting the acid corrosion, and the reduction of the acid condensation can significantly relieve the acid corrosive effect on the wall surface and improve the security of the equipments. In this study, the characteristics of both heat transfer and acid condensation of the finned tube in heat exchanger were numerically studied. In the numerical model, we simulated the acid condensation by considering the vapor–liquid equilibrium effect and multi-component diffusion effect. Based on the H-type finned oval tube, we proposed three novel types of fins to both enhance the heat transfer and reduce the acid condensation. The parametric effects of gas temperature, acid vapor concentration, water vapor concentration, and Reynolds number were investigated on different fin structures. The results show that the tube bank with the new structured fins can improve the performance on both heat transfer and acid anticondensation.展开更多
螺旋管蒸汽发生器是液态金属快堆中能量传递的核心设备,其运行的稳定性、安全性对核电站的运行有至关重要的影响。为此,本文构建了液态金属快堆螺旋管蒸汽发生器一次侧、二次侧耦合传热的三维数值模型,分别基于经济合作与发展组织核能署...螺旋管蒸汽发生器是液态金属快堆中能量传递的核心设备,其运行的稳定性、安全性对核电站的运行有至关重要的影响。为此,本文构建了液态金属快堆螺旋管蒸汽发生器一次侧、二次侧耦合传热的三维数值模型,分别基于经济合作与发展组织核能署(The Organisation for Economic Co-operation and Development,OECD/NEA)物性手册和美国国家标准与技术研究院(National Institute of Standards and Technology,NIST)数据库建立液态金属和水-水蒸气变物性计算关联式,采用Lee相变模型计算二次侧水-水蒸气蒸发过程中两相间的质量传递。基于实验数据,分别对本文模型一次侧传热以及二次侧传热的计算可靠性进行了验证。最后以铅铋快堆为例,研究了不同一次侧进口参数下蒸汽发生器一、二次侧之间的耦合传热特性,并与传统水冷堆进行了对比。结果表明:在同等条件下,相比于传统水冷堆,一次侧采用铅铋液态金属时,一、二次侧之间的壁面热流密度明显提升,热流密度峰值可达1439.97 kW·m^(-2),比水冷堆相应数值提升5~6倍,这导致二次侧管内气相蒸发过程明显加剧,体积含气率急剧上升;同时,一、二次侧之间的沿程热流密度分布更加不均匀,沿程热流密度分布相对偏差值比水冷堆相应数值增大3~4倍。随着一次侧进口铅铋温度从350℃增大到450℃,一、二次侧之间的壁面热流密度随之增大,对应的热流密度峰值从950.7 kW·m^(-2)增大到1439.97 kW·m^(-2),提升约1.5倍,同时一、二次侧之间的沿程热流密度分布更加不均匀,不均匀度增大20%。展开更多
文摘A calculation method of heat transfer area for vertical natural circulated steam generator was introduced. According to the design requirements of steam generator 55/19 of CPR1000, its heat transfer area was calculated based on this method. The results show that the accuracy of partitional and overall calculation method is almost the same, but the result is different when using different calculation models. And the results are compared with the foreign companies for 55/19 steam generator.
基金supported by the National Key R&D Program of China(No. 2020YFB1901405)
文摘In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.
基金Funded by the Major State Basic Research Development Program of China(973 Program)(No.2010CB227105)
文摘In order to improve the thermal shock resistance of solar thermal heat transfer tube material, the mullite-cordierite composite ceramic as solar thermal heat transfer tube material were fabricated by pressureless sintering using a-Al203, Suzhou kaolin, talc, and feldspar as starting materials. The important parameter for solar thermal transfer tube such as water absorption (W), bulk density (Db), and the mechanical properties were investigated. The phase composition and microstructure of the composite ceramics were analyzed by XRD and SEM. The experimental results show that the B3 sintered at 1 300 ℃ and holding for 3 h has an optimum thermal shock resistance. The bending strength loss rate of B3 is only 2% at 1 100℃ by air quenching-strength test and the sample can endure 30 times thermal shock cycling, and the water absorption, the bulk density and the bending strength are 0.32%, 2.58 g·cm-3, and 125.59 MPa respectively. The XRD analysis indicated that the phase compositions of the sample were mullite, cordierite, corundum, and spinel. The SEM images illustrate that the cordierite is prismatic grain and the mullite is nano rod, showing a good thermal shock resistance for composite ceramics as potential solar thermal power material.
基金supported by the National Natural Science Foundation of China(Grant No.U2013214)the Self-Planned Task of the State Key Laboratory of Robotics and System(HIT),China(Grant No.SKLRS202001A03).
文摘Many heat transfer tubes are distributed on the tube plates of a steam generator that requires periodic inspection by robots.Existing inspection robots are usually involved in issues:Robots with manipulators need complicated installation due to their fixed base;tube mobile robots suffer from low running efficiency because of their structural restricts.Since there are thousands of tubes to be checked,task planning is essential to guarantee the precise,orderly,and efficient inspection process.Most in-service robots check the task tubes using row-by-row and column-bycolumn planning.This leads to unnecessary inspections,resulting in a long shutdown and affecting the regular operation of a nuclear power plant.Therefore,this paper introduces the structure and control system of a dexterous robot and proposes a task planning method.This method proceeds into three steps:task allocation,base position search,and sequence planning.To allocate the task regions,this method calculates the tool work matrix and proposes a criterion to evaluate a sub-region.And then all tasks contained in the sub-region are considered globally to search the base positions.Lastly,we apply an improved ant colony algorithm for base sequence planning and determine the inspection orders according to the planned path.We validated the optimized algorithm by conducting task planning experiments using our robot on a tube sheet.The results show that the proposed method can accomplish full task coverage with few repetitive or redundant inspections and it increases the efficiency by 33.31% compared to the traditional planning algorithms.
基金supported by the National Basic Research Program of China(2011CB710702)the National Natural Science Foundation of China(51222604)
文摘Acid condensation rate is an important factor denoting the acid corrosion, and the reduction of the acid condensation can significantly relieve the acid corrosive effect on the wall surface and improve the security of the equipments. In this study, the characteristics of both heat transfer and acid condensation of the finned tube in heat exchanger were numerically studied. In the numerical model, we simulated the acid condensation by considering the vapor–liquid equilibrium effect and multi-component diffusion effect. Based on the H-type finned oval tube, we proposed three novel types of fins to both enhance the heat transfer and reduce the acid condensation. The parametric effects of gas temperature, acid vapor concentration, water vapor concentration, and Reynolds number were investigated on different fin structures. The results show that the tube bank with the new structured fins can improve the performance on both heat transfer and acid anticondensation.
文摘螺旋管蒸汽发生器是液态金属快堆中能量传递的核心设备,其运行的稳定性、安全性对核电站的运行有至关重要的影响。为此,本文构建了液态金属快堆螺旋管蒸汽发生器一次侧、二次侧耦合传热的三维数值模型,分别基于经济合作与发展组织核能署(The Organisation for Economic Co-operation and Development,OECD/NEA)物性手册和美国国家标准与技术研究院(National Institute of Standards and Technology,NIST)数据库建立液态金属和水-水蒸气变物性计算关联式,采用Lee相变模型计算二次侧水-水蒸气蒸发过程中两相间的质量传递。基于实验数据,分别对本文模型一次侧传热以及二次侧传热的计算可靠性进行了验证。最后以铅铋快堆为例,研究了不同一次侧进口参数下蒸汽发生器一、二次侧之间的耦合传热特性,并与传统水冷堆进行了对比。结果表明:在同等条件下,相比于传统水冷堆,一次侧采用铅铋液态金属时,一、二次侧之间的壁面热流密度明显提升,热流密度峰值可达1439.97 kW·m^(-2),比水冷堆相应数值提升5~6倍,这导致二次侧管内气相蒸发过程明显加剧,体积含气率急剧上升;同时,一、二次侧之间的沿程热流密度分布更加不均匀,沿程热流密度分布相对偏差值比水冷堆相应数值增大3~4倍。随着一次侧进口铅铋温度从350℃增大到450℃,一、二次侧之间的壁面热流密度随之增大,对应的热流密度峰值从950.7 kW·m^(-2)增大到1439.97 kW·m^(-2),提升约1.5倍,同时一、二次侧之间的沿程热流密度分布更加不均匀,不均匀度增大20%。