期刊文献+
共找到21篇文章
< 1 2 >
每页显示 20 50 100
The Effects of Degradation Phenomena of the Steel-Concrete Interface in Reinforced Concrete Structures
1
作者 Bozabe Renonet Karka Bassa Bruno +1 位作者 Nadjitonon Ngarmaïm Alladjo Rimbarngaye 《Journal of Materials Science and Chemical Engineering》 CAS 2023年第3期1-21,共21页
Reinforced concrete (RC) constructions are the innovation of sustainable constructions replacing masonry constructions. Despite this, the use of concrete and steel to improve the performance of structural members in s... Reinforced concrete (RC) constructions are the innovation of sustainable constructions replacing masonry constructions. Despite this, the use of concrete and steel to improve the performance of structural members in service is a recurring problem due to the immediate or overtime appearance of cracks. The objective of this work was therefore to assess the damage phenomena of the steel-concrete interface in order to assess the performance of an RC structure. Samples of approximately 30 cm of reinforcement attacked by rust were taken from broken reinforced concrete columns and beams in order to determine the impact of corrosion on high adhesion steel (HA) and therefore on its ability to resist. The experimental results have shown that the corrosion degradation rates of reinforcing bars of different diameters increase as the diameter of the reinforcing bars decreases: 5% for HA12;23.75% for HA8 and 50% for HA6. Using the approach proposed by Mangat and Elgalf on the bearing capacity as a function of the progress of the corrosion phenomenon, these rates made it possible to assess the new fracture limits of corroded HA steels. For HA6 respectively HA8 and HA12, their initial limit resistances will decrease by 4/4, 3/4 and 1/4. Based on the results of this study and in order to guarantee their durability, an RC structure can be dimensioned by taking into account the effects of reinforcement corrosion. 展开更多
关键词 Reinforced Concrete Construction steel-concrete Interface Corrosion Degradation Rate ADHESION Bearing Capacity
下载PDF
Experimental study on seismic behaviors of steel-concrete composite frames 被引量:2
2
作者 戚菁菁 蒋丽忠 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第11期4396-4413,共18页
Steel-concrete composite frames are seeing increased use in earthquake region because of their excellent structural characteristics, including high strength, stiffness, and good ductility. However, there exist gaps in... Steel-concrete composite frames are seeing increased use in earthquake region because of their excellent structural characteristics, including high strength, stiffness, and good ductility. However, there exist gaps in the knowledge of seismic behavior and the design provisions for these structures. In order to better understand the seismic behaviors of composite frame systems, eight steel-concrete composite frames were designed. These composite frames were composed of steel-concrete composite beams and concrete filled steel tube columns. The axial compression ratio of column, slenderness ratio and linear stiffness ratio of beam to column were selected as main design parameters. The low reversed cyclic loading tests of composite frame system were carried out. Based on test results, the seismic behaviors of composite frames such as failure mode, hysteresis curve, strength degradation, rigidity degradation, ductility and energy dissipation were studied. Known from the test phenomenon, the main cause of damage is the out-of-plane deformation of steel beam and the yielding destruction of column heel. The hysteretic loops of composite frame appear a spindle shape and no obvious pinch phenomenon. The results demonstrate that this type of composite frame has favorable seismic behaviors. Furthermore, the effects of design parameters on seismic behaviors were also discussed. The results of the experiment show that the different design parameter has different influence rule on seismic behaviors of composite frame. 展开更多
关键词 COMPOSITE FRAME steel-concrete COMPOSITE BEAM conc
下载PDF
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
3
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 Stud connector Experimental research steel-concrete composite structure Cable-stayed bridge Internal force distribution
下载PDF
Mechanical performance of shear studs and application in steel-concrete composite beams 被引量:1
4
作者 朱志辉 张磊 +3 位作者 柏宇 丁发兴 刘劲 周政 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第10期2676-2687,共12页
This work experimentally investigates the effects of shear stud characteristics on the interface slippage of steel-concrete composite push-out specimens. ABAQUS is used to establish a detailed 3D finite element(FE) mo... This work experimentally investigates the effects of shear stud characteristics on the interface slippage of steel-concrete composite push-out specimens. ABAQUS is used to establish a detailed 3D finite element(FE) model and analyze the behavior of push-out specimens. The modeling results are in good agreement with the experimental results. Based on parametrical analysis using the validated FE approaches, the effects of important design parameters, such as the diameter, number, length to diameter ratio, and yield strength of studs, concrete strength and steel transverse reinforcement ratio, on the load-slip relationship at the interface of composite beams are discussed. In addition, a simplified approach to model studs is developed using virtual springs with an equivalent stiffness. This approach is demonstrated to be able to predict the load-displacement response and ultimate bearing capacity of steel-concrete composite beams. The predicted results show satisfactory agreement with experimental results from the literature. 展开更多
关键词 shear studs push-out test load-slip relationship ultimate bearing capacity steel-concrete composite beams
下载PDF
Comparative analysis of cast-in-place post-tensioned and steel-concrete composite bridge bent caps 被引量:1
5
作者 Nur Yazdani Francisco D.B.Ruiz 《Journal of Modern Transportation》 2017年第3期194-204,共11页
The complexity of the IH-635 Managed Lanes Project, located in Dallas County, Texas, posed several technical and constructive challenges, leading to the adoption of solutions different from the traditional. Two altern... The complexity of the IH-635 Managed Lanes Project, located in Dallas County, Texas, posed several technical and constructive challenges, leading to the adoption of solutions different from the traditional. Two alternative solutions for the pier cap on one of the bridge crossings over IH-35E in the IH-635 project were analyzed in this case study, a cast-in-place post-tensioned concrete cap and an innovative prefabricated steel-concrete com- posite cap. The approach was to use an estimation of direct costs for material and labor and consideration of con- struction time schedules. A supplementary numerical modeling confirmed that both alternatives behave elasti- cally under imposed loads. The direct cost of material and labor for the two alternatives were close. However, the composite alternative required 13 days less construction time, resulting in substantial cost savings from traffic closing in the very busy traffic corridor. Traffic closing costs were substantially higher than the direct costs, especially for the post-tensioned cap. The quantification of the benefits allows more confidence in the utilization of the composites caps, leading to faster completion of bridge projects and substantial economic savings. 展开更多
关键词 Bridge pier cap Bridge bent - Post-tensionedstructure steel-concrete cap Cost estimation Construction schedule Traffic closing cost
下载PDF
The Study of Force and the Mechanical Characteristic of Incremental Launching Construction Method on a Steel-Concrete Continuous Beam Bridge 被引量:2
6
作者 Xu Luo 《Journal of Architectural Research and Development》 2019年第6期46-50,共5页
The usage of steel-mixed composite beams is quite extensive today.During an event of constructing steel-mixed composite bridges,the incremental launching construction method is generally adopted.This paper mainly anal... The usage of steel-mixed composite beams is quite extensive today.During an event of constructing steel-mixed composite bridges,the incremental launching construction method is generally adopted.This paper mainly analyzes the force of incremental launching construction on a steel-concrete continuous beam bridge,the classification of incremental launching construction,the application of incremental launching construction in steel-mixed composite beams,the temporary facilities existing in incremental launching construction as well as their existing problems.Lastly,the analysis of the stress of composite beams in incremental launching construction is described by using the reference for the construction of mixed composite continuous beam bridges provided. 展开更多
关键词 steel-concrete Composite BEAM INCREMENTAL LAUNCHING Construction Method Force DISPLACEMENT
下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
7
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
下载PDF
Bending Stiffness of Truss-Reinforced Steel-Concrete Composite Beams
8
作者 Francesco Trentadue Erika Mastromarino +3 位作者 Giuseppe Quaranta Floriana Petrone Giorgio Monti Giuseppe Carlo Marano 《Open Journal of Civil Engineering》 2014年第3期285-300,共16页
This paper is concerned with a special steel-concrete composite beam in which the resisting system is a truss structure whose bottom chord is made of a steel plate supporting the precast floor system. This system work... This paper is concerned with a special steel-concrete composite beam in which the resisting system is a truss structure whose bottom chord is made of a steel plate supporting the precast floor system. This system works in two distinct phases with two different resisting mechanisms: during the construction phase, the truss structure bears the precast floor system and the resisting system is that of a simply supported steel truss;once the concrete has hardened, the truss structure becomes the reinforcing element of a steel-concrete composite beam, where it is also in a pre-stressed condition due to the loads carried before the hardening of concrete. Within this framework, the effects of the diagonal bars on the bending stiffness of this composite beam are investigated. First, a closed-form solution for the evaluation of the equivalent bending stiffness is derived. Subsequently, the influence of geometrical and mechanical characteristics of shear reinforcement is studied. Finally, results obtained from parametric and numerical analyses are discussed. 展开更多
关键词 Bending Stiffness steel-concrete Composite BEAMS PRECAST Floor Systems
下载PDF
Flexural stiffness characterization of the corrugated steel-concrete composite structure for tunnel projects
9
作者 Wenqi Ding Xuanbo Huang +2 位作者 Shuobiao Li Wentong Liu Qingzhao Zhang 《Underground Space》 SCIE EI CSCD 2023年第5期18-30,共13页
Corrugated steel–concrete(CSC)composite structures are increasingly used in tunnel and culvert projects due to their good mechanical properties.The design of CSC composite structures is often governed by deflection l... Corrugated steel–concrete(CSC)composite structures are increasingly used in tunnel and culvert projects due to their good mechanical properties.The design of CSC composite structures is often governed by deflection limits in service,hence it becomes crucial to evaluate accurately their flexural stiffness.In this work,the deflection deformation mechanism of CSC composite structure is studied by experimental and numerical methods,and a simplified formula for calculating the flexural stiffness is established.In addition,the deflection results obtained by different methods are compared and analyzed.It is found that:(1)the flexural stiffness of the CSC composite structure is constant only when the load is small,and after the bending moment exceeds a certain value,the flexural stiffness will gradually become smaller as the bending moment increases.(2)The value of the bending moment corresponding to the end of the elastic stage of the bending moment-deflection curve increases with the increase of the axial force in the composite structure.(3)As the axial force of the composite structure increases,the flexural bearing capacity of the structure increases first and then decreases. 展开更多
关键词 Tunnel and culvert Corrugated steel-concrete composite structure Bending moment Flexural stiffness
原文传递
Field validation of UHPC layer in negative moment region of steel-concrete composite continuous girder bridge
10
作者 Minghong QIU Xudong SHAO +4 位作者 Weiye HU Yanping ZHU Husam H.HUSSEIN Yaobei HE Qiongwei LIU 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2022年第6期744-761,共18页
Improving the cracking resistance of steel-normal concrete(NC)composite beams in the negative moment region is one of the main tasks in designing continuous composite beam(CCB)bridges due to the low tensile strength o... Improving the cracking resistance of steel-normal concrete(NC)composite beams in the negative moment region is one of the main tasks in designing continuous composite beam(CCB)bridges due to the low tensile strength of the NC deck at pier supports.This study proposed an innovative structural configuration for the negative bending moment region in a steel-concrete CCB bridge with the aid of ultrahigh performance concrete(UHPC)layer.In order to investigate the feasibility and effectiveness of this new UHPC jointed structure in the negative bending moment region,field load testing was conducted on a newly built full-scale bridge.The newly designed structural configuration was described in detail regarding the structural characteristics(cracking resistance,economy,durability,and constructability).In the field investigation,strains on the surface of the concrete bridge deck,rebar,and steel beam in the negative bending moment region,as well as mid-span deflection,were measured under different load cases.Also,a finite element model for the four-span superstructure of the full-scale bridge was established and validated by the field test results.The simulated results in terms of strains and mid-span deflection showed moderate consistency with the test results.This field test and the finite element model results demonstrated that the new configuration with the UHPC layer provided an effective alternative for the negative bending moment region of the composite beam. 展开更多
关键词 field test steel-concrete composite beam continuous girder bridge negative bending moment region ultrahigh performance concrete
原文传递
Research on Concrete Preparation for the Steel-concrete Composite Segment of Jingyue Yangtze River Bridge
11
作者 DENG B 《武汉理工大学学报》 CAS CSCD 北大核心 2010年第17期196-200,共5页
To improve the quality of the steel-concrete composite segment of the box girder,to ensure the compactness of concrete to avoid debonding and to enhance the fatigue strength of concrete are critical to the concrete pr... To improve the quality of the steel-concrete composite segment of the box girder,to ensure the compactness of concrete to avoid debonding and to enhance the fatigue strength of concrete are critical to the concrete preparation for such site. Furthermore,the coordination ability to deformation between steel and concrete is also important because of great difference of the elastic modulus between them. Concrete for the steel-concrete composite segment with high fluidity,excellent crack resistance and low shrinkage was prepared by adding efficient poly-carboxylic water-reducing agent,high quality fly ash and expansion agent to it. The quality of the concrete of the half partial testing block showed that the optimal mix proportion of polypropylene fiber reinforced concrete had achieved expected effect,ensured high quality,thus meeting the requirements of construction. 展开更多
关键词 steel-concrete composite segment polypropylene fiber reinforced concrete crack resistance
原文传递
Parametric study on contact sensors for MASW measurement-based interfacial debonding detection for SCCS
12
作者 Chen Hongbing Pang Xin +3 位作者 Gan Shiyu Li Yuanyuan Gokarna Chalise Nie Xin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期331-344,共14页
Steel-concrete composite structures(SCCS)have been widely used as primary load-bearing components in large-scale civil infrastructures.As the basis of the co-working ability of steel plate and concrete,the bonding sta... Steel-concrete composite structures(SCCS)have been widely used as primary load-bearing components in large-scale civil infrastructures.As the basis of the co-working ability of steel plate and concrete,the bonding status plays an essential role in guaranteeing the structural performance of SCCS.Accordingly,efficient non-destructive testing(NDT)on interfacial debondings in SCCS has become a prominent research area.Multi-channel analysis of surface waves(MASW)has been validated as an effective NDT technique for interfacial debonding detection for SCCS.However,the feasibility of MASW must be validated using experimental measurements.This study establishes a high-frequency data synchronous acquisition system with 32 channels to perform comparative verification experiments in depth.First,the current sensing approaches for high-frequency vibration and stress waves are summarized.Secondly,three types of contact sensors,namely,piezoelectric lead-zirconate-titanate(PZT)patches,accelerometers,and ultrasonic transducers,are selected for MASW measurement.Then,the selection and optimization of the force hammer head are performed.Comparative experiments are carried out for the optimal selection of ultrasonic transducers,PZT patches,and accelerometers for MASW measurement.In addition,the influence of different pasting methods on the output signal of the sensor array is discussed.Experimental results indicate that optimized PZT patches,acceleration sensors,and ultrasonic transducers can provide efficient data acquisition for MASW-based non-destructive experiments.The research findings in this study lay a solid foundation for analyzing the recognition accuracy of contact MASW measurement using different sensor arrays. 展开更多
关键词 steel-concrete composite structures(SCCS) interface debonding detection multi-channel analysis of surface waves(MASW) sensor selection comparative experimental study
下载PDF
Recent progress of seismic research on tall buildings in China Mainland 被引量:2
13
作者 Lu Xilin Jiang Huanjun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第S1期47-61,共15页
As a result of rapid economic growth and urbanization in the past two decades,many tall buildings have been constructed in China Mainland,offering researchers and practitioners an excellent opportunity for research an... As a result of rapid economic growth and urbanization in the past two decades,many tall buildings have been constructed in China Mainland,offering researchers and practitioners an excellent opportunity for research and practice in the field of structural engineering. This paper reviews progress by researchers throughout China Mainland on the seismic research of tall buildings,focusing on three major topics that impact the seismic performance of tall buildings. These are:(1) new types of steel-concrete composite structural members such as steel-concrete composite shear walls and columns,(2) earthquake resilient shear wall structures such as shear walls with replaceable structural components,self-centering shear walls and rocking walls,and(3) performance-based seismic design,including seismic performance index,performance level and design method. The paper concludes by presenting future research needs and directions in this field. 展开更多
关键词 tall buildings steel-concrete composite member earthquake resilient structure performance-based seismic design
下载PDF
Connection between Concrete Layers with Different Strengths 被引量:1
14
作者 Jae Yoon Kang Jong Sup Park +1 位作者 Woo Tai Jung Moon Seoung Keum 《Engineering(科研)》 2015年第7期365-372,共8页
As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the met... As part of a research intending to develop steel-concrete hybrid girder using ultra high performance concrete with compressive strength of 80 MPa, this study conducts loading test on this girder to investigate the methods for its composition with a slab using 30 MPa-concrete and the corresponding interfacial behavior. Prior to the loading test, the design formula of the Eurocode for the shear resistance developed in concrete-to-concrete interface is examined for the interface between concrete layers of different strengths. The effect of the surface roughness on the shear resistance is examined using this formula and finite element analysis to verify the applicability of the formula. Based upon the results, loading test is conducted on girder specimens to evaluate the actual behavior with respect to the interfacial surface condition. The test results reveal that the specimen with rough interface could not develop perfectly composite behavior and experienced adhesive failure. In case of simultaneous action of flexure and shear, it appears that conservative design should be applied without consideration of the interfacial condition when determining the arrangement of shear reinforcement. 展开更多
关键词 Shear Resistance Interface BETWEEN CONCRETE LAYERS Surface ROUGHNESS steel-concrete Hybrid GIRDER Ultra High Performance CONCRETE (UHPC)
下载PDF
Ductility and Ultimate Capacity of Concrete-Filled Lattice Rectangular Steel Tube Columns
15
作者 Chengquan Wang Yun Zou +3 位作者 Tianqi Li Jie Ding Xiaoping Feng Tiange Lei 《Structural Durability & Health Monitoring》 EI 2018年第2期99-110,共12页
A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation c... A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation curves from the test results,the rationality and reliability of the finite element model has been confirmed,moreover,the change of the section stiffness and stress in the forcing process and the ultimate bearing capacity of the column were analyzed.Based on the model,the comparison of ultimate bearing capacity and ductility between CFLRST column and reinforced concrete(RC)column were also analyzed.The results of the finite element analysis show that the loading process of CFLRST column consists of elastic stage,yield stage and failure stage.The failure modes are mainly strength failure and failure of elastoplastic instability.CFLRST column has higher bearing capacities in comparison with reinforced concrete columns with the same steel ratio.In addition,the stiffness degeneration of CFLRST column is slower than RC column and CFLRST column has good ductility. 展开更多
关键词 steel-concrete composite structure concrete-filled lattice rectangular steel tube column nonlinear finite element ultimate strength DUCTILITY
下载PDF
A Study on the Structural Response of a PSC Inner Containment Dome with Large Openings Due to Prestress Transfer
16
作者 Anirudh A. Desai Sekhar K. Chakrabarti 《World Journal of Nuclear Science and Technology》 2014年第2期103-122,共20页
A linear three dimensional finite element (FE) study has been carried out to examine the structural response of a prestressed concrete (PSC) inner containment (IC) dome of reactor building (double containment system) ... A linear three dimensional finite element (FE) study has been carried out to examine the structural response of a prestressed concrete (PSC) inner containment (IC) dome of reactor building (double containment system) of a typical Indian Nuclear Power Plant, having large steam generator (SG) openings with due emphasis on the local behaviour of the steel-concrete interfaces at the SG openings, due to initial prestress transfer. The predominant thrust of the study has been placed on the objective of predicting the possibilities of separation at the steel-concrete interface zones adjacent to the embedded plates (EPs) of the SG openings. Two types of modeling and analysis have been made to study the overall and local behaviour of the structure. Prestressing ducts, passive reinforcements and EPs have been included in the models in certain ways. For the FE analysis, the interface zone has been modeled using interface elements, the properties of which were derived from the results of past experiments conducted on steel plate-concrete inter-face specimens. The FE analysis results have been compared with the results of the past two FE analytical studies on the linear behaviour of the same PSC IC dome. Important observations have been made regarding dome deformation and stresses throughout the structure with special emphasis on the local behaviour of steel-concrete interfaces at and around the SG openings. 展开更多
关键词 PRESTRESSED Concrete INNER CONTAINMENT Reactor Building Double CONTAINMENT System steel-concrete Interface Steam Generator OPENINGS Steel Embedded Plates
下载PDF
Method of Dimensioning Stress-Strain State of Steel Concrete Plate
17
作者 Emmanuel Yamb Christian A. Bock Hyeng 《Materials Sciences and Applications》 2013年第7期1-5,共5页
The steel-concrete constructions experience an increased development this last time. The main advantages are that they ensure the economy of materials, energy and labour. The steel-concrete elements allow a rational u... The steel-concrete constructions experience an increased development this last time. The main advantages are that they ensure the economy of materials, energy and labour. The steel-concrete elements allow a rational use of the concrete in the tensile zone, ensure a reduction of the weight of the building, its cost and also reduce the formwork. The calculations carried out by the authors make it possible to establish the dependence between the constraints and the deformations in the principal directions under a biaxial state of stresses, to obtain the expressions of the principal moments, determine the parameters of the deformations of the concrete Eb, Ebi, νb, νbi, obtained through the reduction of the tensile and compressive stresses of the concrete in an isotropic conventional homogeneous state. The expressions of the constraints in the plate are gotten and compared between the theoretical values and the experimental convergence of the results with a variation of less than 8%. 展开更多
关键词 Stress STRAIN steel-concrete INTERNAL FORCES
下载PDF
Vibration Analysis and Fatigue Assessment of Floors.Part I:Human Rhythmic Activities
18
作者 Ana C.S.da Silva Elisângela A.R.Santos +2 位作者 Leandro A.Deus Mayara M.Martins JoséG.S.da Silva 《Journal of Civil Engineering and Architecture》 2021年第10期497-503,共7页
Structural problems associated with excessive vibration of building floor systems when subjected to human rhythmic activities have been frequent.In this context,this research work aims to develop an analysis methodolo... Structural problems associated with excessive vibration of building floor systems when subjected to human rhythmic activities have been frequent.In this context,this research work aims to develop an analysis methodology to evaluate the human comfort and assess the fatigue performance of steel-concrete composite floors when subjected to human rhythmic activities(aerobics).The investigated structural model corresponds to a steel-concrete floor with dimensions of 10 m×10 m and a total area of 100 m^(2).The numerical model developed for the dynamic analysis of the floor adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of people practicing rhythmic activities on the structure,in order to verify the occurrence of excessive vibration and to assess the human comfort.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results indicated that,in several analysed situations,the investigated floor presents excessive vibration and user’s discomfort.On the other hand,the structure service life values were higher than those proposed by the design codes,ensuring that the members,connections and joints will not fail by fatigue cracking. 展开更多
关键词 steel-concrete composite floors human rhythmic activities vibration analysis human comfort fatigue assessment.
下载PDF
Vibration Analysis and Fatigue Assessment of Floors.Part II:Mechanical Equipment
19
作者 Ana C.S.da Silva Gabriel M.Sant’Anna +2 位作者 Lucia H.G.Cardoso AndréV.Castilho JoséG.S.da Silva 《Journal of Civil Engineering and Architecture》 2021年第10期504-510,共7页
Floors subjected to mechanical equipment loads frequently present problems associated with excessive vibration which can cause human discomfort or even reduce the structure service life.In this context,this work aims ... Floors subjected to mechanical equipment loads frequently present problems associated with excessive vibration which can cause human discomfort or even reduce the structure service life.In this context,this work aims to develop an analysis methodology in order to assess the fatigue performance of steel-concrete composite floors,when subjected to vibrations induced by mechanical equipment.The studied structural model corresponds to a steel-concrete composite floor spanning 10 m by 10 m,with a total area of 100 m^(2).The numerical model developed for the dynamic analysis adopted the usual mesh refinement techniques present in finite element method(FEM)simulations implemented in the ANSYS program.The investigated floor dynamic response was calculated through the consideration of the dynamic loadings imposed by the mechanical equipment,simulated based on the use of harmonic forces applied on the concrete slabs.Furthermore,the dynamic structural response was performed considering several scenarios for the positioning of the equipment,in order to verify the occurrence of excessive vibration.The fatigue assessment is based on a linear cumulative damage rule through the use of the Rainflow-counting algorithm and S-N curves from traditional design codes.The results of this investigation indicated that the equipment position affects directly the floor dynamic structural response and also significantly influences the structure service life. 展开更多
关键词 steel-concrete composite floors mechanical equipment dynamic structural analysis fatigue assessment.
下载PDF
Research review on steel–concrete composite joint of railway hybrid girder cable-stayed bridges
20
作者 Zhou Shi Jiachang Gu +1 位作者 Yongcong Zhou Ying Zhang 《Railway Sciences》 2022年第2期241-259,共19页
Purpose–This study aims to research the development trend,research status,research results and existing problems of the steel–concrete composite joint of railway long-span hybrid girder cable-stayed bridge.Design/me... Purpose–This study aims to research the development trend,research status,research results and existing problems of the steel–concrete composite joint of railway long-span hybrid girder cable-stayed bridge.Design/methodology/approach–Based on the investigation and analysis of the development history,structure form,structural parameters,stress characteristics,shear connector stress state,force transmission mechanism,and fatigue performance,aiming at the steel–concrete composite joint of railway long-span hybrid girder cable-stayed bridge,the development trend,research status,research results and existing problems are expounded.Findings–The shear-compression composite joint has become the main form in practice,featuring shortened length and simplified structure.The length of composite joints between 1.5 and 3.0 m has no significant effect on the stress and force transmission laws of the main girder.The reasonable thickness of the bearing plate is 40–70 mm.The calculation theory and simplified calculation formula of the overall bearing capacity,the nonuniformity and distribution laws of the shear connector,the force transferring ratio of steel and concrete components,the fatigue failure mechanism and structural parameters effects are the focus of the research study.Originality/value–This study puts forward some suggestions and prospects for the structural design and theoretical research of the steel–concrete composite joint of railway long-span hybrid girder cable-stayed bridge. 展开更多
关键词 RAILWAY Hybrid girder cable-stayed bridge steel-concrete composite joint STRUCTURE Stress characteristics REVIEW
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部