This study aimed to investigate the moment redistribution in continuous glass fiber reinforced polymer(GFRP)-concrete composite slabs caused by concrete cracking and steel bar yielding in the negative bending moment z...This study aimed to investigate the moment redistribution in continuous glass fiber reinforced polymer(GFRP)-concrete composite slabs caused by concrete cracking and steel bar yielding in the negative bending moment zone.An experimental bending moment redistribution test was conducted on continuous GFRP-concrete composite slabs,and a calculation method based on the conjugate beam method was proposed.The composite slabs were formed by combining GFRP profiles with a concrete layer and supported on steel beams to create two-span continuous composite slab specimens.Two methods,epoxy resin bonding,and stud connection,were used to connect the composite slabs with the steel beams.The experimental findings showed that the specimen connected with epoxy resin exhibited two moments redistribution phenomena during the loading process:concrete cracking and steel bar yielding at the internal support.In contrast,the composite slab connected with steel beams by studs exhibited only one-moment redistribution phenomenon throughout the loading process.As the concrete at the internal support cracked,the bending moment decreased in the internal support section and increased in the midspan section.When the steel bars yielded,the bending moment further decreased in the internal support section and increased in the mid-span section.Since GFRP profiles do not experience cracking,there was no significant decrease in the bending moment of the mid-span section.All test specimens experienced compressive failure of concrete at the mid-span section.Calculation results showed good agreement between the calculated and experimental values of bending moments in the mid-span section and internal support section.The proposed model can effectively predict the moment redistribution behavior of continuous GFRP-concrete composite slabs.展开更多
The recent increase in blast/bombing incidents all over the world has pushed the development of effective strengthening approaches to enhance the blast resistance of existing civil infrastructures.Engineered geopolyme...The recent increase in blast/bombing incidents all over the world has pushed the development of effective strengthening approaches to enhance the blast resistance of existing civil infrastructures.Engineered geopolymer composite(EGC)is a promising material featured by eco-friendly,fast-setting and strain-hardening characteristics for emergent strengthening and construction.However,the fiber optimization for preparing EGC and its protective effect on structural elements under blast scenarios are uncertain.In this study,laboratory tests were firstly conducted to evaluate the effects of fiber types on the properties of EGC in terms of workability,dry shrinkage,and mechanical properties in compression,tension and flexure.The experimental results showed that EGC containing PE fiber exhibited suitable workability,acceptable dry shrinkage and superior mechanical properties compared with other types of fibers.After that,a series of field tests were carried out to evaluate the effectiveness of EGC retrofitting layer on the enhancement of blast performance of typical elements.The tests include autoclaved aerated concrete(AAC)masonry walls subjected to vented gas explosion,reinforced AAC panels subjected to TNT explosion and plain concrete slabs subjected to contact explosion.It was found that EGC could effectively enhance the blast resistance of structural elements in different scenarios.For AAC masonry walls and panels,with the existence of EGC,the integrity of specimens could be maintained,and their deflections and damage were significantly reduced.For plain concrete slabs,the EGC overlay could reduce the diameter and depth of the crater and spallation of specimens.展开更多
For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength gr...For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength grades of the concrete and the span-depth ratios of the composite wall, which have impacts on the shear resistance performance of the composite shear wail, are analyzed by the numerical simulation method. Meanwhile, the simplified calculation formulae of the initial elastic lateral-resisting stiffness and the shear bearing capacity of the composite shear wall are also proposed. The research shows that with the increase in the thicknesses of the steel plates and the concrete and the increase in the strength grades of the concrete, the shear performance of the shear wall improves obviously; the span-depth ratios of the composite wall have a significant effect on the initial elastic lateral- resisting stiffness, but a small effect on the shear bearing capacity. Comparing the results of the simplified calculation formulae with those of the nonlinear finite element method, it is obvious that the presented formulae are reasonable and meet the real force state of the structure. These conclusions can serve as a preliminary design reference for the steel-concrete- steel composite shear wall.展开更多
Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in...Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering.展开更多
Mechanical behavior of concrete slab of large-span through tied-arch composite bridge was investigated by finite element analysis (FEA). Improved methods to decrease concrete stresses were discussed based on compariso...Mechanical behavior of concrete slab of large-span through tied-arch composite bridge was investigated by finite element analysis (FEA). Improved methods to decrease concrete stresses were discussed based on comparisons of different deck schemes, construction sequences and measures, and ratios of reinforcement. The results show that the mechanical behavior of concrete slab gets worse with the increase of composite regions between steel beams and concrete slab. The deck scheme with the minimum composite region is recommended on condition that both strength and stiffness of the bridge meet design demands under service loads. Adopting in-situ-place construction method, concrete is suggested to be cast after removing the full-supported frameworks under the bridge. Thus, the axial tensile force of concrete slab caused by the first stage dead load is eliminated. Preloading the bridge before concrete casting and removing the load after the concrete reaching its design strength, the stresses of concrete slab caused by the second stage dead load and live load are further reduced or even eliminated. At last, with a high ratio of reinforcement more than 3%, the concrete stresses decrease obviously.展开更多
To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,on...To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,one cast-in-site concrete slab of ordinary concrete and one CCS of ordinary concrete by steel bar truss(as recommended in the technical specification for precast concrete structures in Chinese)were compared through experiments.The carrying capacity,flexural behaviour and bi-directional mechanical properties of the specimens were systematically analyzed from the failure modes,load-deflection curves,load-bar strain curves,load-slip curves and crack distributions.Results show that the bending failure process of CCSs with a SFRRAC base plate is similar to that of the cast-in-site concrete slab of ordinary concrete and CCS of ordinary concrete by steel bar truss,as all of them went through the plastic phase,elastic plastic phase and failure phase with fully developed cracks and deflection.No sudden breakage or horizontal cracking of the connecting interface between the base plate and concrete topping was observed.The shape of the base plate has a major impact on the bearing capacity of the CCS with the SFRRAC base plate.When calculating the ultimate bearing capacity with the plastic yield line theory,the influence of the base plate shape on the plastic yield line position should be taken into account.展开更多
A corner-pumped Nd:YAG/YAG composite slab continuous-wave laser operating at 1064 nm,1074 nm,1112 nm,1116 nm,and 1123 nm simultaneously and a laser that is tunable at these wavelengths are reported for the first time...A corner-pumped Nd:YAG/YAG composite slab continuous-wave laser operating at 1064 nm,1074 nm,1112 nm,1116 nm,and 1123 nm simultaneously and a laser that is tunable at these wavelengths are reported for the first time.The maximum output power of the five-wavelength laser is 5.66 W with an optical-to-optical conversion efficiency of 11.3%.After a birefringent filter is inserted in the cavity,the five wavelengths can be separated successfully by rotating the filter.The maximum output powers of the 1064 nm,1074 nm,1112 nm,1116 nm,and 1123 nm lasers are 1.51 W,1.3 W,1.27 W,0.86 W,and 0.72 W,respectively.展开更多
A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present se...A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.展开更多
Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-ten...Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-tensioned concrete slab and, after the concrete sets, acts as external reinforcement. In this type of slab, longitudinal shear failure between the concrete and the steel sheeting is the most common type of failure at the ultimate load stage. Design codes require the experimental evaluation of the longitudinal shear capacity of each type of steel decking using full-scale tests. This paper presents the results of the short-term testing up to failure of two types of profiled steel decking that are commonly used in the construction industry in Australia. Fourteen full-scale, simply-supported slabs were tested in four-point bending with shear spans of either span/4 or span/6. Four slabs were tested at age of 28 days and the other 10 slabs were subjected to drying shrinkage and various levels of sustained loads for a period of at least 6 months prior to testing to failure. The effects of creep and drying shrinkage on the load carrying capacity and deformation of the slabs at ultimate loads are presented and discussed. The bond-slip relationship of each slab is determined from the test data and the values of maximum longitudinal shear stress calculated using different methods are described and compared.展开更多
基金supported by National Natural Science Foundation of China(Project No.51878156,received by Wen-Wei Wang and EPC Innovation Consulting Project for Longkou Nanshan LNG Phase I Receiving Terminal(Z2000LGENT0399,received by Wen-Wei Wang and ZhaoJun Zhang).
文摘This study aimed to investigate the moment redistribution in continuous glass fiber reinforced polymer(GFRP)-concrete composite slabs caused by concrete cracking and steel bar yielding in the negative bending moment zone.An experimental bending moment redistribution test was conducted on continuous GFRP-concrete composite slabs,and a calculation method based on the conjugate beam method was proposed.The composite slabs were formed by combining GFRP profiles with a concrete layer and supported on steel beams to create two-span continuous composite slab specimens.Two methods,epoxy resin bonding,and stud connection,were used to connect the composite slabs with the steel beams.The experimental findings showed that the specimen connected with epoxy resin exhibited two moments redistribution phenomena during the loading process:concrete cracking and steel bar yielding at the internal support.In contrast,the composite slab connected with steel beams by studs exhibited only one-moment redistribution phenomenon throughout the loading process.As the concrete at the internal support cracked,the bending moment decreased in the internal support section and increased in the midspan section.When the steel bars yielded,the bending moment further decreased in the internal support section and increased in the mid-span section.Since GFRP profiles do not experience cracking,there was no significant decrease in the bending moment of the mid-span section.All test specimens experienced compressive failure of concrete at the mid-span section.Calculation results showed good agreement between the calculated and experimental values of bending moments in the mid-span section and internal support section.The proposed model can effectively predict the moment redistribution behavior of continuous GFRP-concrete composite slabs.
基金National Natural Science Foundation of China(Grant Nos.51908188 and 51938011).
文摘The recent increase in blast/bombing incidents all over the world has pushed the development of effective strengthening approaches to enhance the blast resistance of existing civil infrastructures.Engineered geopolymer composite(EGC)is a promising material featured by eco-friendly,fast-setting and strain-hardening characteristics for emergent strengthening and construction.However,the fiber optimization for preparing EGC and its protective effect on structural elements under blast scenarios are uncertain.In this study,laboratory tests were firstly conducted to evaluate the effects of fiber types on the properties of EGC in terms of workability,dry shrinkage,and mechanical properties in compression,tension and flexure.The experimental results showed that EGC containing PE fiber exhibited suitable workability,acceptable dry shrinkage and superior mechanical properties compared with other types of fibers.After that,a series of field tests were carried out to evaluate the effectiveness of EGC retrofitting layer on the enhancement of blast performance of typical elements.The tests include autoclaved aerated concrete(AAC)masonry walls subjected to vented gas explosion,reinforced AAC panels subjected to TNT explosion and plain concrete slabs subjected to contact explosion.It was found that EGC could effectively enhance the blast resistance of structural elements in different scenarios.For AAC masonry walls and panels,with the existence of EGC,the integrity of specimens could be maintained,and their deflections and damage were significantly reduced.For plain concrete slabs,the EGC overlay could reduce the diameter and depth of the crater and spallation of specimens.
基金The Basic Scientific Research Funds of Hohai University (No. B1020133)
文摘For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength grades of the concrete and the span-depth ratios of the composite wall, which have impacts on the shear resistance performance of the composite shear wail, are analyzed by the numerical simulation method. Meanwhile, the simplified calculation formulae of the initial elastic lateral-resisting stiffness and the shear bearing capacity of the composite shear wall are also proposed. The research shows that with the increase in the thicknesses of the steel plates and the concrete and the increase in the strength grades of the concrete, the shear performance of the shear wall improves obviously; the span-depth ratios of the composite wall have a significant effect on the initial elastic lateral- resisting stiffness, but a small effect on the shear bearing capacity. Comparing the results of the simplified calculation formulae with those of the nonlinear finite element method, it is obvious that the presented formulae are reasonable and meet the real force state of the structure. These conclusions can serve as a preliminary design reference for the steel-concrete- steel composite shear wall.
文摘Finite element method is employed to calculate the temperature fields for two kinds of steel concrete composite slabs: composite slab with profiled steel sheeting and LJMB composite slab. The calculated results are in good agreement with those of tests. Fire resistance of the two kinds of composite slabs is calculated by using a numeric method. The results show that: due to heat absorbing of concrete, the performance of composite slabs under fire is better than that of unprotected steel structure, and fire resistance of composite slabs mentioned in this paper is at least 30 min subjected to standard fire. Parameters related to the fire resistance are discussed. It was found that with increasing of concrete strength and thickness of slab, fire resistance increases, and with increasing of steel strength and steel ratio, fire resistance decreases. Also thickness of fire proof is calculated by a numeric method. The results obtained in this paper may be referenced for practical engineering.
基金Project(2005k002-c-2) supported by the Science and Technology Development Program of Railways Department, China
文摘Mechanical behavior of concrete slab of large-span through tied-arch composite bridge was investigated by finite element analysis (FEA). Improved methods to decrease concrete stresses were discussed based on comparisons of different deck schemes, construction sequences and measures, and ratios of reinforcement. The results show that the mechanical behavior of concrete slab gets worse with the increase of composite regions between steel beams and concrete slab. The deck scheme with the minimum composite region is recommended on condition that both strength and stiffness of the bridge meet design demands under service loads. Adopting in-situ-place construction method, concrete is suggested to be cast after removing the full-supported frameworks under the bridge. Thus, the axial tensile force of concrete slab caused by the first stage dead load is eliminated. Preloading the bridge before concrete casting and removing the load after the concrete reaching its design strength, the stresses of concrete slab caused by the second stage dead load and live load are further reduced or even eliminated. At last, with a high ratio of reinforcement more than 3%, the concrete stresses decrease obviously.
基金The National Natural Science Foundation of China(No.51578446).
文摘To promote the application of green renewable materials in concrete composite slabs(CCSs)and study the flexural behavior of CCSs with different shapes,the bending performances of three CCSs with a SFRRAC base plate,one cast-in-site concrete slab of ordinary concrete and one CCS of ordinary concrete by steel bar truss(as recommended in the technical specification for precast concrete structures in Chinese)were compared through experiments.The carrying capacity,flexural behaviour and bi-directional mechanical properties of the specimens were systematically analyzed from the failure modes,load-deflection curves,load-bar strain curves,load-slip curves and crack distributions.Results show that the bending failure process of CCSs with a SFRRAC base plate is similar to that of the cast-in-site concrete slab of ordinary concrete and CCS of ordinary concrete by steel bar truss,as all of them went through the plastic phase,elastic plastic phase and failure phase with fully developed cracks and deflection.No sudden breakage or horizontal cracking of the connecting interface between the base plate and concrete topping was observed.The shape of the base plate has a major impact on the bearing capacity of the CCS with the SFRRAC base plate.When calculating the ultimate bearing capacity with the plastic yield line theory,the influence of the base plate shape on the plastic yield line position should be taken into account.
基金Project supported by the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20110002120054)the National High Technology Research and Development Program of China (Grant No. 2011AA030208)
文摘A corner-pumped Nd:YAG/YAG composite slab continuous-wave laser operating at 1064 nm,1074 nm,1112 nm,1116 nm,and 1123 nm simultaneously and a laser that is tunable at these wavelengths are reported for the first time.The maximum output power of the five-wavelength laser is 5.66 W with an optical-to-optical conversion efficiency of 11.3%.After a birefringent filter is inserted in the cavity,the five wavelengths can be separated successfully by rotating the filter.The maximum output powers of the 1064 nm,1074 nm,1112 nm,1116 nm,and 1123 nm lasers are 1.51 W,1.3 W,1.27 W,0.86 W,and 0.72 W,respectively.
基金The authors acknowledge the financial support provided by the National Natural Science Foundation of China(51890902 and 51708058).
文摘A large-span steel–concrete composite beam with precast hollow core slabs(CBHCSs)is a relatively new floor structure that can be applied to various long-span structures.However,human-induced vibrations may present serviceability issues in such structures.To alleviate vibrations,both the walking forces excited by humans and the associated floor responses must be elucidated.In this study,150 load–time histories of walking,excited by 25 test participants,are obtained using a force measuring plate.The dynamic loading factors and phase angles in the Fourier series functions for one-step walking are determined.Subsequently,walking tests are performed on seven CBHCS specimens to capture the essential dynamic properties of mode shapes,natural frequencies,damping ratios,and acceleration time histories.The CBHCS floor system generally exhibits a high frequency(>10 Hz)and low damping(damping ratio<2%).Sensitivity studies using the finite element method are conducted to investigate the vibration performance of the CBHCS floor system,where the floor thickness,steel beam type,contact time,and human weight are considered.Finally,analytical expressions derived for the fundamental frequency and peak acceleration agree well with the experimental results and are hence proposed for practical use.
文摘Composite one-way concrete slabs with profiled steel sheeting as permanent formwork are commonly used in the construction industry. The steel sheeting supports the wet concrete of a cast-in-situ reinforced or post-tensioned concrete slab and, after the concrete sets, acts as external reinforcement. In this type of slab, longitudinal shear failure between the concrete and the steel sheeting is the most common type of failure at the ultimate load stage. Design codes require the experimental evaluation of the longitudinal shear capacity of each type of steel decking using full-scale tests. This paper presents the results of the short-term testing up to failure of two types of profiled steel decking that are commonly used in the construction industry in Australia. Fourteen full-scale, simply-supported slabs were tested in four-point bending with shear spans of either span/4 or span/6. Four slabs were tested at age of 28 days and the other 10 slabs were subjected to drying shrinkage and various levels of sustained loads for a period of at least 6 months prior to testing to failure. The effects of creep and drying shrinkage on the load carrying capacity and deformation of the slabs at ultimate loads are presented and discussed. The bond-slip relationship of each slab is determined from the test data and the values of maximum longitudinal shear stress calculated using different methods are described and compared.