期刊文献+
共找到723篇文章
< 1 2 37 >
每页显示 20 50 100
Stent fracture after transjugular intrahepatic portosystemic shunt placement using the bare metal stent/stent-graft combination technique
1
作者 Qi-Jia Liu Xiao-Feng Cao +3 位作者 Yun Pei Xuan Li Guo-Xiang Dong Chang-Ming Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第10期2133-2141,共9页
BACKGROUND A transjugular intrahepatic portosystemic shunt(TIPS)is widely placed to treat portal hypertension.Because the Viatorr®stent(W.L.Gore and Associates,Flagstaff,AZ,United States)is not available in all h... BACKGROUND A transjugular intrahepatic portosystemic shunt(TIPS)is widely placed to treat portal hypertension.Because the Viatorr®stent(W.L.Gore and Associates,Flagstaff,AZ,United States)is not available in all hospitals in China,the bare metal stent(BMS)/stent-graft combination technique is still popular for TIPS construction.Stent fracture is a complication after TIPS placement using this technique,with limited available literature focusing on it.AIM To assess the incidence of stent fracture after TIPS placement using the BMS/stent-graft combination technique and to identify the risk factors for stent fracture.We proposed technique modifications to improve the clinical results of TIPS placement with the BMS/stent-graft combination technique.METHODS We retrospectively analyzed the computed tomography(CT)data of all patients with portal hypertension who underwent the TIPS procedure between June 2011 and December 2021 in a single center.Patients implanted with the BMS/stent graft and had follow-up imaging data available were included.We identified patients with stent fracture and analyzed their characteristics.Multivariable logistic regression was applied to identify the potential predictors of stent fracture.RESULTS Of the 68 included patients,stent fracture occurred in seven(10.3%)patients.Based on CT images,the stent fractures were categorized into three types.Our study consisted of four(57.1%)type I fractures,one(14.3%)type II fracture,one(14.3%)type IIIa fracture,and one(14.3%)type IIIb fracture.After adjusting for covariates,multivariable logistic regression revealed that the risk factors for stent fracture were the implantation of a greater number of stents[adjusted odds ratio(aOR)=22.2,95%confidence interval(CI):1.2-415.4,P=0.038]and a larger proximal sagittal stent bending angle(aOR=1.1,95%CI:1.0-1.3,P=0.020).CONCLUSION Stent fracture occurred in approximately 10%of patients with portal hypertension who underwent TIPS with the BMS/stent-graft combination technique.The number of implanted stents and stent bending angle at the inferior vena cava end were predictors of stent fracture,which suggests that the incidence of stent fracture could potentially be reduced by procedural modifications. 展开更多
关键词 Portal hypertension Transjugular intrahepatic portosystemic shunt Stent fracture Bare metal stent/stent-graft combination Risk factor Fracture types
下载PDF
Stent-grafts for the treatment of TIPS dysfunction:Fluency stent vs Wallgraft stent 被引量:9
2
作者 Xue-Feng Luo Ling Nie +6 位作者 Zhu Wang Jiaywei Tsauo Ling-Jun Liu Yang Yu Biao Zhou Cheng-Wei Tang Xiao Li 《World Journal of Gastroenterology》 SCIE CAS 2013年第30期5000-5005,共6页
AIM:To evaluate the clinical efficacy of an expanded polytetrafluoro-ethylene-covered Fluency stent compared with that of a polyethylene terephthalate-covered Wallgraft stent for the management of transjugular intrahe... AIM:To evaluate the clinical efficacy of an expanded polytetrafluoro-ethylene-covered Fluency stent compared with that of a polyethylene terephthalate-covered Wallgraft stent for the management of transjugular intrahepatic portosystemic shunt(TIPS)dysfunction.METHODS:A retrospective review of patients who underwent TIPS revision with stent-grafts between May 2007 and June 2011 was conducted.The patients were divided into two groups according to the stentgrafts implanted:the Fluency stent(Bard Incorporated,Karlsruhe,Germany)and the Wallgraft stent(Boston Scientific,Galway,Ireland).The primary patency rates were calculated and compared using the Kaplan-Meier method.RESULTS:A total of 73 patients were evaluated in this study:33 with Fluency stents and 40 with Wallgraft stents.The primary patency rates at 12 and 24 mo were 91% and 85%,respectively,in the Fluency stent group and 78% and 63%,respectively,in the Wallgraft stent group.The primary shunt patency rates after TIPS revision were significantly better with the Fluency stent than with the Wallgraft stent(P = 0.033).CONCLUSION:TIPS revision with the Fluency stent has higher medium-term patency rates than that with the Wallgraft stent. 展开更多
关键词 Expanded polytetrafluoroethylene-covered stent-grafts Transjugular INTRAHEPATIC portosystemic SHUNT DYSFUNCTION Revision FLUENCY
下载PDF
Experimental and computational studies on the flow fields in aortic aneurysms associated with deployment of AAA stent-grafts 被引量:7
3
作者 Xiwen Zhang Zhaohui Yao +1 位作者 Yan Zhang Shangdong Xu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2007年第5期495-501,共7页
Pulsatile flow fields in rigid abdominal aortic aneurysm (AAA) models were investigated numerically, and the simulation results are found in good agreement with particle image velocimetry (PIV) measurements. There... Pulsatile flow fields in rigid abdominal aortic aneurysm (AAA) models were investigated numerically, and the simulation results are found in good agreement with particle image velocimetry (PIV) measurements. There are one or more vortexes in the AAA bulge, and a fairly high wall shear stress exists at the distal end, and thus the AAA is in danger of rupture. Medical treatment consists of inserting a vascular stent-graft in the AAA, which would decrease the blood impact to the inner walls and reduce wall shear stress so that the rupture could be prevented. A new computational model, based on porous medium model, was developed and results are documented. Therapeutic effect of the stent-graft was verified numerically with the new model. 展开更多
关键词 Abdominal aortic aneurysm Numerical simulation Particle image velocimetry Wall shear stress stent-graft
下载PDF
Stent-grafts placement for treatment of massive hemorrhage from ruptured hepatic artery after pancreaticoduodenectomy 被引量:2
4
作者 Mao-Qiang Wang Feng-Yong Liu +3 位作者 Feng Duan Zhi-Jun Wang Peng Song Qing-Sheng Fan 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第29期3716-3722,共7页
AIM:To present a series of cases with life-threatening hemorrhage from ruptured hepatic artery pseudoaneurysm after pancreaticoduodenectomy(PD) treated with placement of stent-grafts.METHODS:Massive hemorrhage from ru... AIM:To present a series of cases with life-threatening hemorrhage from ruptured hepatic artery pseudoaneurysm after pancreaticoduodenectomy(PD) treated with placement of stent-grafts.METHODS:Massive hemorrhage from ruptured hepatic artery pseudoaneurysm after PD in 9 patients(6 men,3 women) at the age of 23-75 years(mean 48 years),were treated with placement of percutaneous endovascular balloon-expandable coronary stent-grafts.All patients were not suitable for embolization because of a non-patent portal vein.One or more stent-grafts,ranging 3-6 mm in diameter and 16-55 mm in length,were placed to exclude ruptured pseudoaneurysm.Followup data,including clinical condition,liver function tests,and Doppler ultrasound examination,were recorded at the outpatient clinic.RESULTS:Immediate technical success was achieved in all the 9 patients.All stent-grafts were deployed in the intended position for immediate cessation of bleeding and preservation of satisfactory hepatic arterial blood flow.No significant procedure-related complications occurred.Recurrent bleeding occurred in 2 patients at 16 and 24 h,respectively,after placement of stent-grafts and treated with surgical revision.One patient died of sepsis 12 d after the interventional procedure.The remaining 6 patients were survived when they were discharged.The mean follow-up time was 10.5 mo(range 4-16 mo).No patient had recurrent bleeding after discharge.Doppler ultrasound examination verified the patency of hepatic artery and stent-grafts during the follow-up.CONCLUSION:Placement of stent-grafts is an effective and safe procedure for acute life-threatening hemorrhage from ruptured hepatic artery pseudoaneurysm. 展开更多
关键词 PANCREATICODUODENECTOMY HEMORRHAGE Hepatic artery PSEUDOANEURYSM stent-graft
下载PDF
Endovascular stent-grafts for acute and chronic type B aortic dissection: comparison of clinical outcomes 被引量:2
5
作者 Quanming Jing Yaling Han Xiaozheng Wang Jie Deng Bo Luan Hongxu Jin Xiaojiang Liu Fei Li Ying Liu 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第2期67-71,共5页
Objective To evaluate the early and mid-term results of endovascular repair for acute and chronic type B aortic dissection, and to compare the clinical outcomes between the 2 groups. Methods From May 2002 to December ... Objective To evaluate the early and mid-term results of endovascular repair for acute and chronic type B aortic dissection, and to compare the clinical outcomes between the 2 groups. Methods From May 2002 to December 2006, 50 patients with type B aortic dissection were treated by endovascular stent-graft. There were 23 patients in the acute aortic dissection (AAD) group and 27 patients in the chronic aortic dissection (CAD) group. All patients were followed up from 1 to 54 months (average, 17±16 months).The immediate and follow-up clinical outcomes were documented and compared between the 2 groups. Results Placement of endovascular stent-grafts across the primary entry tears was technically successful in all 50 patients. Compared to the CAD group, the AAD group had a higher percentage of pleural effusion (17.4% vs. 0%, P=0.04) and visceral /leg ischemia (26.1% vs 3.7%, P=0.04). Procedure related complications, including endoleak and post-implantation syndrome, occurred more frequently in the AAD group than in the CAD group (21.7% vs 3.7% and 30.4% vs 11.1%, respectively; P=0.08 and P=0.04). Kaplan–Meier analysis showed no difference in the survival rate at 4 years between the 2 groups (86.4% vs 92.3%, P=0.42 by log-rank test). However, the event-free survival rate was higher in patients with chronic dissection than in patients with acute aortic dissection(96.2% vs 73.9%; P=0.02 by log-rank test). Conclu- sions Endovascular repair with stent-graft was safe and effective for the treatment of both acute and chronic type B aortic dissection. However, both immediate and long term major complications occurred more frequently in patients with acute dissection than in those with chronic dissection. 展开更多
关键词 AORTIC DISSECTION ENDOVASCULAR repairing stent-graft
下载PDF
Short-term results in canines of novel stent-graft design for chimney technique in TEVAR 被引量:5
6
作者 Ming Li Chang Shu +2 位作者 Benhao Xiao Dingxiao Liu Weichang Zhang 《Journal of Interventional Medicine》 2020年第3期128-131,共4页
Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.... Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.The short-and mid-term results of this technique are satisfactory;however,endoleak remains a major concern.Thus,here we designed a new chimney stent-graft to decrease the endoleak rate.Aim:To testify the feasibility and safety of the new chimney stent-graft system in a canine model.Material and methods:Six Labrador retrievers were used.Pre-operative data were collected and all operations were performed under general anesthesia.The main and chimney stent-grafts were implanted through the abdominal aorta and left subclavian artery approaches,respectively.Completion digital subtraction angiography(DSA)was performed to confirm the immediate outcomes.All dogs were fed separately for 6 months and sacrificed after aortic angiography.The thoracic aorta and the main and chimney stent-grafts were harvested for histopathologic examination.Results:No complications were found in follow-up DSA.All branch arteries were patent.In?ammatory responses were observed around the stent-grafts in 3 experimental animals,and slight hyperplasia was observed in the surrounding tissues compared with the normal vessels.There was no mural thrombus in the stent,endothelial cells were noted on the inner surface of the stent,and thrombus was formed in the outer skirt and gutter area.The histopathologic examinations revealed similar results to those of gross necropsy observations.Conclusions:This study demonstrated the feasibility and safety of the Longuette stent-graft and the first to report a revised stent-graft specific for chimney technique. 展开更多
关键词 Thoracic endovascular aortic repair Chimney technique Canine model In vivo experiment stent-graft
下载PDF
Fatigue Performance of Fabrics of Stent-Grafts Supported with Z-Stents vs. Ringed Stents 被引量:1
7
作者 林婧 宋戈 +4 位作者 管晓宁 王璐 杜佳 NUTLEY Mark GUIDOIN Robert 《Journal of Donghua University(English Edition)》 EI CAS 2013年第5期367-370,共4页
Stent-grafts were commercialized rapidly and gained a broad clinical acceptance over the past two decades. However,relatively more recent recognition of particular stent-graft design shortcomings have been identified ... Stent-grafts were commercialized rapidly and gained a broad clinical acceptance over the past two decades. However,relatively more recent recognition of particular stent-graft design shortcomings have been identified which need to be addressed. It appears that various stent-graft designs may be more or less resistant to metal fatigue and /or fabric abrasions which can lead to type III and type IV endoleaks over the long term. Therefore,it is necessary to investigate the fatigue performance of the most common stentgraft designs: Z-stents and ringed stents,in a long-term in vitro fatigue simulation environment. This paper aimed to analyze nondestructively( gross observations) and destructively( fabric characteristics,mechanical and chemical properties) in order to put forward suggestions to improve the fabric and stent characteristics that may prevent type III and IV endoleaks. The fabric supported with ringed stent-grafts remained nearly completely intact after 168h. However, the fabric supported with Z-stents demonstrated significant damage. Fabric characteristics and tensile strength of the fibers did not present a significant difference between the control and fatigue simulated specimens. The crystallinity declined for both specimens. The fatigue performance of fabrics supported with ringed stents appears to be superior to that supported with Z-stents. The potential for a dynamic and destructive interaction between the apices of Z-stents which can lead to fraying and /or tearing of the graft fabric must be addressed in future designs. 展开更多
关键词 stent-graft FATIGUE performance FABRICS Z-stents ringed STENTS
下载PDF
Total endovascular repair of aberrant right subclavian artery using caster branched stent-graft 被引量:1
8
作者 Guo-Yi SUN Wei GUO +8 位作者 Xiao-Ping LIU Xin JIA Jiang XIONG Hong-Peng ZHANG Xiao-Hui MA Feng CHEN Sen-Hao JIA Jie LIU Yang-Yang GE 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第12期751-754,共4页
A 57-year-old man has 20-year history of hypertension presented with intermittent chronic pain in the chest area and shoulder blades over the last three months.Computed tomographic angiography(CTA)on admission reveale... A 57-year-old man has 20-year history of hypertension presented with intermittent chronic pain in the chest area and shoulder blades over the last three months.Computed tomographic angiography(CTA)on admission revealed a chronic type B aortic dissection(TBAD)with an aberrant right subclavian artery(ARSA)crossed behind the trachea and bovine aortic arch(Figure IB). 展开更多
关键词 ABERRANT right SUBCLAVIAN artery AORTIC dissection Branch stent-graft Thoracic ENDOVASCULAR AORTIC repair
下载PDF
Endovascular stent-grafts for acute and chronic type B aortic dissection: comparison of clinical outcomes 被引量:1
9
作者 David Jayakar 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第2期72-,共1页
  Within the recent months, endovascular repair of aortic aneurysms has become a rather interesting alternative to patients considering open surgery. In the past, the procedure was typically and more solely reserved...   Within the recent months, endovascular repair of aortic aneurysms has become a rather interesting alternative to patients considering open surgery. In the past, the procedure was typically and more solely reserved to a selected group of elderly patients with several co-morbidities.…… 展开更多
关键词 Endovascular stent-grafts for acute and chronic type B aortic dissection comparison of clinical outcomes TYPE
下载PDF
Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: A case report 被引量:3
10
作者 Xu-Ran Li Yuan-Hao Tong +3 位作者 Xiao-Qiang Li Chang-Jian Liu Chen Liu Zhao Liu 《World Journal of Clinical Cases》 SCIE 2020年第5期954-962,共9页
BACKGROUND A 46-year-old male underwent ascending aortic replacement,total arch replacement,and descending aortic stent implantation for Stanford type A aortic dissection in 2016.However,an intraoperative stent-graft ... BACKGROUND A 46-year-old male underwent ascending aortic replacement,total arch replacement,and descending aortic stent implantation for Stanford type A aortic dissection in 2016.However,an intraoperative stent-graft was deployed in the false lumen inadvertently.This caused severe iatrogenic thoracic and abdominal aortic dissection,and the dissection involved many visceral arteries.CASE SUMMARY The patient had pain in the chest and back for 1 mo.A computed tomography scan showed that the patient had secondary thoracic and abdominal aortic dissection.The ascending aortic replacement,total arch replacement,and descending aortic stent implantation for Stanford type A aortic dissection were performed 2 years prior.An intraoperative stent-graft was deployed in the false lumen.Endovascular aneurysm repair was performed to address this intractable situation.An occluder was used to occlude the proximal end of the true lumen,and a covered stent was used to direct blood flow back to the true lumen.A three-dimensional printing technique was used in this operation to guide prefenestration.The computed tomography scan at the 1stmo after surgery showed that the thoracic and abdominal aortic dissection was repaired,with all visceral arteries remaining patent.The patient did not develop renal failure or neurological complications after surgery.CONCLUSION The total endovascular repair for false lumen stent-graft implantation was feasible and minimally invasive.Our procedures provided a new solution for stent-graft deployed in the false lumen,and other departments may be inspired by this case when they need to rescue a disastrous stent implantation. 展开更多
关键词 Type A dissection False lumen stent graft implantation Endovascular repair 3D printing Thoracoabdominal aortic dissection Case report
下载PDF
颈动脉狭窄合并冠心病同期外科治疗的疗效分析:单中心经验
11
作者 叶志东 贺斌 +2 位作者 张建彬 陈洁 刘鹏 《中国血管外科杂志(电子版)》 2024年第1期28-31,共4页
目的总结同期颈动脉血运重建手术及冠状动脉血运重建手术治疗颈动脉狭窄合并冠心病患者的单中心临床经验。方法回顾性分析2008年1月至2020年1月中日友好医院心脏血管外科收治的54例颈动脉狭窄合并冠心病患者资料,其中同期行颈动脉内膜... 目的总结同期颈动脉血运重建手术及冠状动脉血运重建手术治疗颈动脉狭窄合并冠心病患者的单中心临床经验。方法回顾性分析2008年1月至2020年1月中日友好医院心脏血管外科收治的54例颈动脉狭窄合并冠心病患者资料,其中同期行颈动脉内膜剥脱术(carotid endarterectomy,CEA)+冠状动脉搭桥术(coronary artery bypass grafting,CABG)38例,同期行颈动脉支架植入术(carotid artery stenting,CAS)+CABG 16例。结果手术成功率100%。围手术期内出现小卒中3例,短暂性脑缺血发作4例,术后短暂低血压8例,术后高灌注综合征3例,二次开胸3例,心肌梗死4例;无围手术期死亡病例。同期CEA+CABG组与同期CAS+CABG组的手术时间、术中出血量、围手术期输血量、神经系统并发症和循环系统并发症发生率差异均无统计学意义(P>0.05)。48例患者获得随访,随访时间29~140个月,平均(89.8±35.6)个月,因心肌梗死和心功能不全死亡患者各1例。结论同期CEA+CABG与同期CAS+CABG治疗颈动脉狭窄合并冠心病患者均安全有效。 展开更多
关键词 颈动脉狭窄 冠心病 颈动脉内膜剥脱术 颈动脉支架植入术 冠状动脉搭桥术 同期手术
下载PDF
血管通路顽固性狭窄病变递进处置策略及临床分析
12
作者 吴限 叶红 +2 位作者 顾春峰 卞雪芹 雒湲 《中国血液净化》 CSCD 2024年第1期57-61,共5页
目的对于动静脉内瘘顽固性狭窄病变,采取递进处置策略进行干预治疗,分析该方案治疗的预后,旨在探讨更为有效合理的动静脉内瘘维护手段。方法回顾性分析2020年6月—2021年6月在南京医科大学第二附属医院血液净化中心因高位自体动静脉内瘘... 目的对于动静脉内瘘顽固性狭窄病变,采取递进处置策略进行干预治疗,分析该方案治疗的预后,旨在探讨更为有效合理的动静脉内瘘维护手段。方法回顾性分析2020年6月—2021年6月在南京医科大学第二附属医院血液净化中心因高位自体动静脉内瘘(autologous arteriovenous fistula,AVF)头静脉弓狭窄和人工血管动静脉内瘘(arteriovenous graft,AVG)静脉吻合口区域狭窄首次行超声引导经皮腔内血管成形术(percutaneous transluminal angioplasty,PTA)治疗,并采取递进处置策略维护的患者,随访24个月观察内瘘的通畅和再干预情况,另与南京医科大学第二附属医院血液净化中心同类病变单纯以高压球囊维护的随访数据比较得出结论。结果高位AVF头静脉弓狭窄采取递进处置策略维护的患者31例,单纯以高压球囊扩张规律维护的患者16例,随访24个月,两者在再干预次数(t=4.461,P<0.001)、再干预后平均通畅时间(t=3.550,P<0.001)及PTA辅助通畅率(χ^(2)=5.562,P=0.021)方面比较差异有统计学意义;AVG静脉吻合口区域狭窄采取递进处置策略维护的患者68例,单纯以高压球囊扩张规律维护的患者58例,随访24个月,两者在再干预次数(t=5.094,P<0.001)及再干预后平均通畅时间(t=3.251,P=0.002)方面比较差异有统计学意义。结论采取递进处置策略,循序渐进地使用各种介入治疗器械以及手术方案处置动静脉内瘘顽固性狭窄病变可以提高PTA的通畅性,减少干预频次,改善预后。 展开更多
关键词 动静脉内瘘 头静脉弓 人工血管静脉吻合口 扩张球囊导管 覆膜支架
下载PDF
New nitinol endovascular stent-graft system for abdominal aortic aneurysm with finite element analysis and experimental verification 被引量:1
13
作者 Xiao-Chen Zhou Fan Yang +3 位作者 Xiao-Yan Gong Ming Zhao Yu-Feng Zheng Zhi-Li Sun 《Rare Metals》 SCIE EI CAS CSCD 2019年第6期495-502,共8页
Abdominal aortic aneurysm(AAA) is one of the most common and catastrophic manifestations of the acute aortic syndrome that can be treated with endovascular aneurysm repair(EVAR) which requires a specially designed ste... Abdominal aortic aneurysm(AAA) is one of the most common and catastrophic manifestations of the acute aortic syndrome that can be treated with endovascular aneurysm repair(EVAR) which requires a specially designed stent-graft system.In this work, a self-expanding nickel–titanium(nitinol) stent-graft system is aiming at AAA using finite element analysis(FEA) methods to analyze both fatigue behaviors and radial forces.Based on the systematic analysis of the parametric variations, a final stent-graft system was developed by the selection and arrangement of the individual stent components, targeting an optimal performance for the treatment of AAA.Experimental tests, animal tests and clinical trials were carried out to confirm the results.Both animal trials and clinical trials showed comparable curative effects with Medtronic Endurant stent-graft(SG) systems. 展开更多
关键词 Nitinol stent-graft SYSTEM ABDOMINAL AORTIC ANEURYSM Fatigue safety factor RADIAL force Finite element analysis
原文传递
Development of new endovascular stent-graft system for type B thoracic aortic dissection with finite element analysis and experimental verification 被引量:1
14
作者 Xiaochen Zhou Fan Yang +3 位作者 Xiaoyan Gong Ming Zhao Yufeng Zheng Zhili Sun 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2019年第11期2682-2692,共11页
Endovascular repair of the thoracic aorta with self-expanding stent-grafts has been emerging as a less invasive alternative treatment compared with conventional open surgeries.Despite the promising efficacy and safety... Endovascular repair of the thoracic aorta with self-expanding stent-grafts has been emerging as a less invasive alternative treatment compared with conventional open surgeries.Despite the promising efficacy and safety of endovascular stent grafting,the stent-graft failure remains a major concern in terms of stent migration,device fatigue,and the risk of endoleaks.Challenges associated with the stent-grafts involve optimized geometrical structure,lifetime fatigue resistance,and adequate radial support.In this work,a novel endovascular stent-graft system is developed specially for the treatment of Stanford type B thoracic aortic dissections(TAD).Numerical study with finite element analysis(FEA)was utilized to evaluate the mechanical behaviors of the individual stent component.Results of the simulation were validated by experimental tests.Based on the systematic analysis of the parametric variations,a final stent-graft system was developed by the selection and arrangement of the individual stent components,targeting an optimal performance for treatment of TAD.The optimized solution of the stent-graft system was tested in clinical trials,showing advantageous therapeutic efficacy. 展开更多
关键词 stent-graft Thoracic aortic dissection Seal zone Fatigue safety factor Radial force Finite element analysis Nitinol
原文传递
Stent-grafting combined with transcatheter embolization for a ruptured isolated hypogastric artery aneurysm 被引量:1
15
作者 DONG Zhi-hui FU Wei-guo GUO Da-qiao XU Xin CHEN Bin JIANG Jun-hao YANG Jue SHI Zheng-yu WANG Yu-qi 《Chinese Medical Journal》 SCIE CAS CSCD 2006年第10期878-880,共3页
Rupture of isolated hypogastric artery aneurysm (HAA) is rarely encountered and is associated with a high mortality rate. Conventional surgery can not achieve distal control easily and may cause substantial blood lo... Rupture of isolated hypogastric artery aneurysm (HAA) is rarely encountered and is associated with a high mortality rate. Conventional surgery can not achieve distal control easily and may cause substantial blood loss, yielding high operative morbidity and mortality. On March 17, 2005, we treated a patient with such a disease successfully by using endovascular stent-grafting combined with transcatheter embolization. 展开更多
关键词 hypogastric artery aneurysm rupture stent-grafting transcatheter embolization
原文传递
Customized and in situ fenestrated stent-grafts:A reinforced poly-ε-caprolactone branch cuff designed to prevent type III endoleaks and enhance hemodynamics 被引量:1
16
作者 Fujun Wang Chaojing Li +8 位作者 Robert Guidoin Abedalwafa Mohammed Graeham Douglas Fan Zhao Guy Dionne Ze Zhang Haripriya Ramesh Lu Wang Mark Nutley 《Medicine in Novel Technology and Devices》 2021年第1期26-36,共11页
Superior long-term anchorage of the bridging stent-grafts from the fenestrated main body endograft could be achieved with the addition of a flared cuff,capable of preventing the previously observed fabric fraying arou... Superior long-term anchorage of the bridging stent-grafts from the fenestrated main body endograft could be achieved with the addition of a flared cuff,capable of preventing the previously observed fabric fraying around the fenestration as a result of the balloon angioplasty of the seal zone.This novel stent cuff design will also facilitate more complete biointegration of the devices,eliminate the hemodynamic variation as well as significantly reduce the possibility of a Type III endoleak.The feasibility of this concept is demonstrated by observations made from in-situ tests performed in a Beta endograft design.Flared cuffs made of poly(ε-caprolactone)supported with a weft-knitted polyester structure can be manufactured with various configurations to optimize the transition from the main body of the endograft,thus preventing the currently marketed designs’hemodynamic perturbation while also promoting endograft biointegration.This concept represents an evolution in branch graft design,which may enhance the long-term durability of customized fenestrations and open new applications for in-vivo graft fenestration in the near future.Further ongoing investigation to optimize its structure,X-ray opacity,fixation to the flared stent,and material biocompatibility are still required to build upon this concept’s proof. 展开更多
关键词 Flared cuff FENESTRATION stent-grafts Poly(ε-caprolactone) Polyester fabrics
原文传递
Stanford B型主动脉夹层腔内修复术后主动脉扩张性病变的研究进展
17
作者 李天祎 《介入放射学杂志》 CSCD 北大核心 2024年第4期443-448,共6页
胸主动脉腔内修复术(thoracic endovascular aortic repair,TEVAR)目前是Stanford B型主动脉夹层(type B aortic dissection,TBAD)的主要治疗方法,当下治疗原则以封堵近端破口为主,而旷置远端破口导致假腔血栓化受阻;主动脉形态及支架... 胸主动脉腔内修复术(thoracic endovascular aortic repair,TEVAR)目前是Stanford B型主动脉夹层(type B aortic dissection,TBAD)的主要治疗方法,当下治疗原则以封堵近端破口为主,而旷置远端破口导致假腔血栓化受阻;主动脉形态及支架远端弹性应力变化,导致管腔局部点压力扩大,形成新发破口或再发夹层导致假腔瘤样扩张,甚至急性破裂致死。术后应通过定期CTA随访,严密监测支架远端管径变化、残留破口直径及假腔血栓化程度。本文通过总结国内外文献,对TEVAR后主动脉扩张性病变的发病原因、机制及处理方法等进行归纳并作综述。 展开更多
关键词 胸主动脉腔内修复术 主动脉夹层 支架移植物远端新发破口
下载PDF
分支型主动脉覆膜支架治疗Stanford B型主动脉夹层的临床使用评价
18
作者 李艳娜 张淼 +1 位作者 李岳飞 夏慧琳 《现代仪器与医疗》 CAS 2024年第3期71-76,共6页
目的基于真实世界的数据多维度评估分支型主动脉覆膜支架治疗锚定区不足的主动脉夹层StanFord B型的安全性、有效性、经济性,为临床的合理使用提供科学依据。方法选取2021年1月—2023年6月在内蒙古自治区人民医院治疗的胸主动脉夹层Stan... 目的基于真实世界的数据多维度评估分支型主动脉覆膜支架治疗锚定区不足的主动脉夹层StanFord B型的安全性、有效性、经济性,为临床的合理使用提供科学依据。方法选取2021年1月—2023年6月在内蒙古自治区人民医院治疗的胸主动脉夹层Stanford B型伴锚定区不足的患者71例。根据腔内修复术手段的不同,分为观察组32例、对照组39例。根据各种方法的相关临床数据,对其围手术期和随访期的主要观察指标、次要观察指标进行统计学分析,对比各组的临床效果。结果两组患者在基线资料、既往史、实验室检查指标情况比较,差异无统计学意义(P>0.05)。术后实验室指标检查、围手术期不利医学事件情况比较,差异无统计学意义(P>0.05)。两组手术安全性大致相似。观察组术中出血量小于对照组,差异有统计学意义(P<0.05)。两组术后即刻效果、术后2月随访情况对比,差异无统计学意义(P>0.05)。使用分支型主动脉覆膜支架治疗有效性优于杂交手术治疗。观察组手术时间、术后住院时间、总住院时间方面明显短于对照组,差异有统计学意义(P<0.05)。两组在住院总费用、医用耗材费用、植入材料费用方面,差异无统计学意义(P>0.05)。使用分支型主动脉覆膜支架治疗经济性优于杂交手术治疗。结论分支型主动脉覆膜支架治疗胸主动脉夹层疾病安全有效,经济适中,且适用范围广,适用于锚定区不足的胸主动脉夹层Stanford B型患者腔内治疗,术后远期效果有待进一步跟踪,真实世界数据有待扩充。 展开更多
关键词 分支型主动脉覆膜支架 胸主动脉夹层Stanford B型 锚定区不足 临床使用评价 真实世界
下载PDF
A novel pressure difference-induced perforation aortic stent-grafts system: an experimental study
19
作者 DENG Guo-yu ZHOU Jian +7 位作者 LU Qing-sheng WANG Lu HOU Le-wei DONG Jian WANG Jian-nan ZHANG Shu-ming ZHAO Zhi-qing JING Zai-ping 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第7期1264-1268,共5页
Background Most of endovascular stent-graft modifications to preserve side branch must be customized according to extensive pre-operative assessment, which may not be possible in many hospitals and emergency settings.... Background Most of endovascular stent-graft modifications to preserve side branch must be customized according to extensive pre-operative assessment, which may not be possible in many hospitals and emergency settings. The study was to develop a novel stent-grafts system that would allow in situ "fenestration", with less reliance on preoperative imaging. Methods The magnitude of pressure difference (PD) between left subclavian artery (LSA) and aortic arch were measured in 12 experimental pigs. Changes of PD before and after LSA was covered were analyzed respectively. The novel stent graft was made by multi-dimensional and multiple textiles forming technology. According to the PD measurement in pigs, we evaluated the feasibility of the stent-graft in a mock circulation system. Results In pigs, the blood pressure of aortic arch was significantly higher than that of LSA after it was covered (P 〈0.001) and PD was (42.78±5.17) mmHg. After target vessel was covered and when PD between the LSA and aorta reached the magnitude measured in pigs, contrast media oozed from the cranny of graft to the LSA, which was generated by sliding and deformation of yarns of novel stent-graft. Conclusions The study proposes the design of pressure difference-induced perforation aortic stent-grafts system and verifies that the PD between LSA and aortic arch is high enough to allow in situ "fenestration" by stent graft made by multi-dimensional and multiple textiles forming technoloav. 展开更多
关键词 AORTA left subclavian artery stent-graft pressure difference mock circulation
原文传递
Research and clinical translation of trilayer stent-graft of expanded polytetrafluoroethylene for interventional treatment of aortic dissection
20
作者 Gang Wang Caiyun Gao +9 位作者 Benhao Xiao Jie Zhang Xunyuan Jiang Qunsong Wang Jingzhen Guo Deyuan Zhang Jianxiong Liu Yuehui Xie Chang Shu Jiandong Ding 《Regenerative Biomaterials》 SCIE EI 2022年第1期650-664,共15页
The aortic dissection(AD)is a life-threatening disease.The transcatheter endovascular aortic repair(EVAR)affords a minimally invasive technique to save the lives of these critical patients,and an appropriate stent-gra... The aortic dissection(AD)is a life-threatening disease.The transcatheter endovascular aortic repair(EVAR)affords a minimally invasive technique to save the lives of these critical patients,and an appropriate stent-graft gets to be the key medical device during an EVAR procedure.Herein,we report a trilayer stent-graft and corresponding delivery system used for the treatment of the AD disease.The stent-graft is made of nitinol stents with an asymmetric Z-wave design and two expanded polytetrafluoroethylene(ePTFE)membranes.Each of the inner and outer surfaces of the stent-graft was covered by an ePTFE membrane,and the two membranes were then sintered together.The biological studies of the sintered ePTFE membranes indicated that the stent-graft had excellent cytocompatibility and hemocompatibility in vitro.Both the stent-graft and the delivery system exhibited satisfactory mechanical properties and operability.The safety and efficacy of this stent-graft and the corresponding delivery system were demonstrated in vivo.In nine canine experiments,the blood vessels of the animals implanted with the stent-grafts were of good patency,and there were no thrombus and obvious stenosis by angiography after implantation for 6months.Furthermore,all of the nine clinical cases experienced successful implantation using the stent-graft and its postrelease delivery system,and the 1-year follow-ups indicated the preliminary safety and efficacy of the trilayer stent-graft with an asymmetric Z-wave design for interventional treatment. 展开更多
关键词 aortic dissection stent-graft expanded polytetrafluoroethylene delivery system for interventional treatment clinical translation of biomaterials
原文传递
上一页 1 2 37 下一页 到第
使用帮助 返回顶部