期刊文献+
共找到1,489篇文章
< 1 2 75 >
每页显示 20 50 100
Strategy of dealing with left subclavian artery in total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection
1
作者 崔勇 《外科研究与新技术》 2011年第3期176-177,共2页
Objective To summarize the experiences of ligating left subclavian artery ( LSA ) in total arch peplacement and stented elephant trunk implantation for Stanford type A aortic dissection patients with difficulty in exp... Objective To summarize the experiences of ligating left subclavian artery ( LSA ) in total arch peplacement and stented elephant trunk implantation for Stanford type A aortic dissection patients with difficulty in exposing the LSA. Methods Total arch replacement and stented elephant trunk implantation were performed on 79 consecutive 展开更多
关键词 left LSA Strategy of dealing with left subclavian artery in total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection type
下载PDF
Influence of Strut Cross-section of Stents on Local Hemodynamics in Stented Arteries 被引量:2
2
作者 JIANG Yongfei ZHANG Jun ZHAO Wanhua 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第3期624-632,共9页
Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression... Stenting is a very effective treatment for stenotic vascular diseases, but vascular geometries altered by stent implantation may lead to flow disturbances which play an important role in the initiation and progression of restenosis, especially in the near wall in stented arterial regions. So stent designs have become one of the indispensable factors needed to be considered for reducing the flow disturbances. In this paper, the structural designs of strut cross-section are considered as an aspect of stent designs to be studied in details. Six virtual stents with different strut cross-section are designed for deployments in the same ideal arterial model. Computational fluid dynamics(CFD) methods are performed to study how the shape and the aspect ratio(AR) of strut cross-section modified the local hemodynamics in the stented segments. The results indicate that stents with different strut cross-sections have different influence on the hemodynamics. Stents with streamlined cross-sectional struts for circular arc or elliptical arc can significantly enhance wall shear stress(WSS) in the stented segments, and reduce the flow disturbances around stent struts. The performances of stents with streamlined cross-sectional struts are better than that of stents with non-streamlined cross-sectional struts for rectangle. The results also show that stents with a larger AR cross-section are more conductive to improve the blood flow. The present study provides an understanding of the flow physics in the vicinity of stent struts and indicates that the shape and AR of strut cross-section ought to be considered as important factors to minimize flow disturbance in stent designs. 展开更多
关键词 stent restenosis wall shear stress hemodynamics computational fluid dynamics
下载PDF
Prevalence of hypercoagulable states in stented thrombotic iliac vein compression syndrome with comparison of re-intervention and anticoagulation regimens 被引量:1
3
作者 Peyton Cramer Cheryl Mensah +3 位作者 Maria DeSancho Anuj Malhotra Ronald Winokur Andrew Kesselman 《World Journal of Radiology》 2021年第12期371-379,共9页
BACKGROUND Endovascular therapy is playing an increasing role in the treatment of iliofemoral venous disease.Iliac stent patency is multifactorial,and current management is based on best clinical practices,varying by ... BACKGROUND Endovascular therapy is playing an increasing role in the treatment of iliofemoral venous disease.Iliac stent patency is multifactorial,and current management is based on best clinical practices,varying by institution.AIM To evaluate how thrombophilia influences management and outcomes of patients who undergo venous stenting for thrombotic iliac vein compression syndromes.METHODS A retrospective observational analysis was performed on 65 patients with thrombotic iliac vein compression syndrome that underwent common iliac vein(CIV)stenting between December 2013 and December 2019 at a large academic center.Search criteria included CIV stenting and iliac vein compression.Nonthrombotic lesions and iliocaval thrombosis and/or occlusions were excluded.A total of 65 patients were selected for final analysis.Demographic information,procedural data points,and post-procedural management and outcomes were collected.Statistical analyses included Fisher's exact and Chi-square tests to compare discrete variables and the Wilcoxon rank-sum test to compare continuous variables between thrombophilia positive and negative patients.RESULTS 65 patients underwent successful balloon angioplasty and CIV stenting.Of these patients,33(50.8%)underwent thrombophilia testing,with 16(48.5%)testing positive.Stent patency on ultrasound did not significantly differ between thrombophilia positive and negative patients at 1 mo(92.3%vs 81.3%,P=0.6),6 mo(83.3%vs 80%,P>0.9),or 12 mo(77.8%vs 76.9%,P=0.8).Immediately after stent placement,thrombophilia patients were more likely to be placed on dual therapy(aspirin and anticoagulation)or triple therapy(aspirin,clopidogrel,and anticoagulation)(50%vs 41.2%,P>0.9),and remain on dual therapy at 6 mo(25%vs 12.5%,P=0.5)and 12 mo(25%vs 6.7%,P=0.6).There was no significant difference in re-intervention rates(25%vs 35.3%,P=0.7)or number of reinterventions(average 2.3 vs 1.3 per patient,P=0.4)between thrombophilia positive and negative patients.CONCLUSION Half of patients with stented thrombotic iliac vein compression syndrome and thrombophilia testing were positive.The presence of thrombophilia did not significantly impact stent patency or re-intervention rates. 展开更多
关键词 THROMBOPHILIA Iliac vein compression syndrome Iliac vein stent May Thurner ANTICOAGULATION ENDOVASCULAR
下载PDF
Plaque components affect wall stress in stented human carotid artery: A numerical study
4
作者 Zhen-Min Fan Xiao Liu +5 位作者 Cheng-Fei Du An-Qiang Sun Nan Zhang Zhan-Ming Fan Yu-Bo Fan Xiao-Yan Deng 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2016年第6期1149-1154,共6页
Carotid artery stenting presents challenges of in-stent restenosis and late thrombosis, which are caused primarily by alterations in the mechanical environment of the artery after stent implantation. The present study... Carotid artery stenting presents challenges of in-stent restenosis and late thrombosis, which are caused primarily by alterations in the mechanical environment of the artery after stent implantation. The present study constructed patient-specific carotid arterial bifurcation models with lipid pools and calcified components based on magnetic resonance imaging. We numerically analyzed the effects of multicomponent plaques on the distributions of von Mises stresses (VMSs) in the patient-specific models after stenting. The results showed that when a stent was deployed, the large soft lipid pool in atherosclerotic plaques cushioned the host artery and reduced the stress within the arterial wall; however, this resulted in a sharp increase of VMS in the fibrous cap. When compared with the lipid pool, the presence of the calcified components led to slightly increased stresses on the luminal surface. However, when a calcification was located close to the luminal surface of the host artery and the stenosis, the local VMS was elevated. Overall, compared with calcified components, large lipid pools severely damaged the host artery after stenting. Furthermore, damage due to the calcified component may depend on location. 展开更多
关键词 ATHEROSCLEROSIS Plaque composition Carotid artery stenting RESTENOSIS Finite-element analysis
下载PDF
Semiurgent CABG after Successful PTCA: Should a Patent Stented Coronary Artery Be By-Passed?
5
作者 Hamdi Tokoz Soner Sanioglu +5 位作者 Onur Sokullu Hakan Hasdemir Azmi Ozler Serap Aykut Aka Ibrahim Yekeler Fuat Bilgen 《Open Journal of Thoracic Surgery》 2012年第3期46-51,共6页
Background: After a successful primary percutaneous transluminal coronary angioplasty (PTCA)/stent placement, performing bypass surgery to an artery with a patent stent during semiurgent coronary artery bypass graftin... Background: After a successful primary percutaneous transluminal coronary angioplasty (PTCA)/stent placement, performing bypass surgery to an artery with a patent stent during semiurgent coronary artery bypass grafting (CABG) surgeries may protect the patient against ischemic complications due to acute stent occlusion. This issue, however, is controversial. Loss of bypass graft function may occur in the early stages due to the competition between native flow and graft flow. In the present study, the effects of bypass surgery to an artery with a patent stent on the outcomes were investigated. Methods: Fifty nine patients who had undergone isolated CABG surgery within 6 weeks after a successful primary PTCA/stent placement were included in the study. Patients who had undergone emergency operation due to suspicion of acute stent occlusion and the redo cases were excluded in the study. Patients were divided into two groups;those with (Group P, protected) and without (Group NP;non-protected) coronary bypass to an artery with a patent stent. Preoperative, operative and postoperative data were collected retrospectively from the patient files. The need for urgent revascularization was recorded postoperatively. Mann-Whitney U test was used for the analysis of continuous variables, whereas categorical variables were analyzed either using Pearson's chisquare test or Fisher's exact test. Results: Of 59 patients, 35 underwent bypass surgery to the artery with patent stent, whereas bypass was not performed on 24 patients. It was observed that dual antiplatelet therapy had been performed on 20% of the patients in Group P and 87.5% of those in Group NP (p = 0.001). No acute ischemic change due to stent occlusion was determined in Group P, whereas it was observed in one patient in Group NP (p = 0.4). The prevalence of hospital mortality was found to be 8.6% and 8.3% in Group P and Group NP, respectively (p = 1). Conclusions: Although it was not statistically significant, it was observed that bypass surgery might have a protective effect against stent occlusion in patients who underwent bypass surgery. However, postoperative dual antiplatelet therapy substantially prevented stent occlusion in those without bypass surgery. On the other hand, stent-supported coronary circulation may be unsafe in case of discontinuation of clopidogrel therapy. Therefore, it was suggested that performing bypass surgery to an artery with a patent stent would be more reasonable in patients who underwent semi-urgent CABG surgery. 展开更多
关键词 Myocardial Infarction CPI STENTS THROMBOSIS CABG
下载PDF
Outcome of stented elephant trunk technique for extensive thoracic aortic aneurysms
6
作者 王振国 于洪泉 李滨 《South China Journal of Cardiology》 CAS 2011年第2期139-146,共8页
Extensive aneurysms involving the ascending aorta, aortic arch, and the descending aorta stand as a therapeutic dilemma in simultaneous management of multiple sites of pathology of the aortic arch and the descending t... Extensive aneurysms involving the ascending aorta, aortic arch, and the descending aorta stand as a therapeutic dilemma in simultaneous management of multiple sites of pathology of the aortic arch and the descending thoracic aorta. We systematically reviewed about literatures of stented elephant trunk operation (SET) identified through searches of the electronic databasesEMBASE and Medline, and aimed to summarize studies of patients undergoing SET for extensive aneurysms. Since 1996, Kato Mintroduced a hybrid technique by using stented graft implantation to the descending aorta for treatment of thoracic aortic aneurysm or dissection. It has been describe a good option for extensive thoracic aortic aneurysms and in a fashion similar to the elephant trunk technique. 展开更多
关键词 stented elephant trunk aortic arch replacement aortic dissection extensive thoracic aneurysms stented graft
原文传递
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis 被引量:6
7
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Unloading and successful treatment with bioresorbable stents during percutaneous coronary intervention:A case report 被引量:2
8
作者 Tao Sun Ming-Xue Zhang +7 位作者 Yan Zeng Li-Hua Ruan Yi Zhang Cheng-Long Yang Zhang Qin Jing Wang Hai-Mei Zhu Yun Long 《World Journal of Cardiology》 2024年第8期484-490,共7页
BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.... BACKGROUND With the development of percutaneous coronary intervention(PCI),the number of interventional procedures without implantation,such as bioresorbable stents(BRS)and drug-coated balloons,has increased annually.Metal drug-eluting stent unloading is one of the most common clinical complications.Comparatively,BRS detachment is more concealed and harmful,but has yet to be reported in clinical research.In this study,we report a case of BRS unloading and successful rescue.This is a case of a 59-year-old male with the following medical history:“Type 2 diabetes mellitus”for 2 years,maintained with metformin extended-release tablets,1 g PO BID;“hypertension”for 20 years,with long-term use of metoprolol sustained-release tablets,47.5 mg PO QD;“hyperlipidemia”for 20 years,without regular medication.He was admitted to the emergency department of our hospital due to intermittent chest pain lasting 18 hours,on February 20,2022 at 15:35.Electrocardiogram results showed sinus rhythm,ST-segment elevation in leads I and avL,and poor R-wave progression in leads V1–3.High-sensitivity troponin I level was 4.59 ng/mL,indicating an acute high lateral wall myocardial infarction.The patient’s family requested treatment with BRS,without implanta-tion.During PCI,the BRS became unloaded but was successfully rescued.The patient was followed up for 2 years;he had no episodes of angina pectoris and was in generally good condition.CONCLUSION We describe a case of a 59-year-old male experienced BRS unloading and successful rescue.By analyzing images,the causes of BRS unloading and the treatment plan are discussed to provide insights for BRS release operations.We discuss preventive measures for BRS unloading. 展开更多
关键词 Coronary artery diseases Percutaneous coronary intervention Bioresorbable stents Stent unloading Stent release Intravascular ultrasound Case report
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage 被引量:1
9
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Outcomes of a non-randomised audit of single pigtail suture stents in urolithiasis management of Asian patients in Singapore
10
作者 Ee Jean Lim Zhen Wei Choo +8 位作者 Reshma Mangat Pradeep Durai Sarvajit Biligere Yiquan Tan Loh Hin Yeung Marcus Nicole Andrea Seet Li Ting Chin Tiong Heng Stefania Ferreti Vineet Gauhar 《Asian Journal of Urology》 CSCD 2024年第2期324-330,共7页
Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symp... Objective:Double-J(DJ)ureteric stents are commonly placed perioperatively for semirigid or flexible ureteroscopic renal surgery.It is believed that lesser stent material within the bladder mitigates stent-related symptoms.This study aimed to evaluate the J-Fil ureteral stent,a single pigtail suture stent compared with conventional DJ stent in relation to stent symptoms in an Asian population undergoing ureterorenal intervention.Methods:Based on internal audit committee recommendation approval,the records of 50 patients retrieved,available data of 41 patients who were prospectively enrolled into two groups(Group 1[J-Fil stent group],n=21 and Group 2[DJ stent group],n=20)between August 2020 to January 2021,were analysed.Parameters compared were nature of procedure,stone location and size,ease of deployment or removal,and complications.A modified universal stent symptom questionnaire was used to assess morbidity of stent symptoms within 48 h of insertion and at removal.Results:Both groups had similar median age,distribution in male to female ratio,and stone size.The overall median universal stent symptom questionnaire score at insertion was similar for bladder pain,flank or loin pain,and quality of life between Group 1 and 2;however,at removal Group 1 fared significantly better than Group 2,especially for flank or loin pain and pain at voiding.Both groups had similar ease in insertion with no hospital readmissions.Conclusion:Our audit favoured the single pigtail suture stent in Asian ureters in mitigating stent-related issues.It showed a good safety profile with easy deployment and removal.It promises a new standard in stenting. 展开更多
关键词 STENT URETEROSCOPY Pigtail suture stent Asianpatient Flexible ureteroscopic renal surgery
下载PDF
The optimal stent pusher position to achieve successful ureteral stent insertion under fluoroscopic guidance
11
作者 Makoto Taguchi Kaneki Yasuda Hidefumi Kinoshita 《Asian Journal of Urology》 CSCD 2024年第2期311-315,共5页
Objective: To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.Methods: We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We ... Objective: To examine factors to predict the optimal stent pusher position when inserting ureteral stents under fluoroscopy.Methods: We retrospectively reviewed 327 patients who underwent ureteral stent insertion. We considered the pubic bone as a useful anatomical landmark to insert ureteral stents under fluoroscopic guidance. Thus, we categorized patients into three groups (proximal, middle, and distal groups) according to the position of the radiopaque tip of the push catheter when inserting the ureteral stent. Success was defined as a completely curled ureteral stent tail. We compared stent insertion success rates among the three groups. A multivariate analysis was performed to identify the factors affecting stent insertion success.Results: In men, 36 (63.2%) cases were deemed successful in the proximal group compared with 40 (80.0%) cases in the middle group and 12 (20.7%) cases in the distal group (p<0.001). In women, 26 (45.6%) cases were deemed successful in the proximal group compared with 54 (98.2%) cases in the middle group and 38 (76.0%) cases in the distal group (p<0.001). With the multivariate analysis, the stent pusher position was the most significant factor influencing successful stent insertion (men: odds ratio 6.00, 95% confidence interval 2.66-13.51, p<0.001;women: odds ratio 37.80, 95% confidence interval 4.94-289.22, p<0.001).Conclusion: The position of the stent pusher affects stent insertion success. The middle of the pubic symphysis is the optimal position for the radiopaque tip of the pusher when inserting ureteral stents under fluoroscopic guidance. 展开更多
关键词 STENT CYSTOSCOPY FLUOROSCOPY URETER
下载PDF
Prevention of complications in endourological management of stones:What are the basic measures needed before,during,and after interventions?
12
作者 Eric Edison Giorgio Mazzon +1 位作者 Vimoshan Arumuham Simon Choong 《Asian Journal of Urology》 CSCD 2024年第2期180-190,共11页
Objective:This narrative review aims to describe measures to minimise the risk of complications during percutaneous nephrolithotomy(PCNL),ureteroscopy,and retrograde intrarenal surgery.Methods:A literature search was ... Objective:This narrative review aims to describe measures to minimise the risk of complications during percutaneous nephrolithotomy(PCNL),ureteroscopy,and retrograde intrarenal surgery.Methods:A literature search was conducted from the PubMed/PMC database for papers published within the last 10 years(January 2012 to December 2022).Search terms included“ureteroscopy”,“retrograde intrarenal surgery”,“PCNL”,“percutaneous nephrolithotomy”,“complications”,“sepsis”,“infection”,“bleed”,“haemorrhage”,and“hemorrhage”.Key papers were identified and included meta-analyses,systematic reviews,guidelines,and primary research.The references of these papers were searched to identify any further relevant papers not included above.Results:The evidence is assimilated with the opinions of the authors to provide recommendations.Best practice pathways for patient care in the pre-operative,intra-operative,and post-operative periods are described,including the identification and management of residual stones.Key complications(sepsis and stent issues)that are relevant for any endourological procedure are then be discussed.Operation-specific considerations are then explored.Key measures for PCNL include optimising access to minimise the chance of bleeding or visceral injury.The role of endoscopic combined intrarenal surgery in this regard is discussed.Key measures for ureteroscopy and retrograde intrarenal surgery include planning and technique to minimise the risk of ureteric injury.The role of anaesthetic assessment is discussed.The importance of specific comorbidities on each step of the pathway is highlighted as examples.Conclusion:This review demonstrates that the principles of meticulous planning,interdisciplinary teamworking,and good operative technique can minimise the risk of complications in endourology. 展开更多
关键词 ENDOUROLOGY URETEROSCOPY Retrogradeintrarenal surgery Percutaneous nephrolithotomy Complications SEPSIS STENT
下载PDF
Can we predict the incidence of high-grade Clavien-Dindo complications in patients with forgotten encrusted stents undergoing endourologic management?
13
作者 Praanjal Gupta Ramanitharan Manikandan +3 位作者 Lalgudi Narayanan Dorairajan Kodakattil Sreenivasan Sreerag Sidhartha Kalra Swapnil Singh Kushwaha 《Asian Journal of Urology》 CSCD 2024年第1期99-104,共6页
Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to re... Objective:Ureteral stents are customarily inserted to facilitate urinary drainage,but they come with their own glitches of being forgotten and/or encrusted leading to serious consequences.The present study aimed to report the complications in patients with forgotten and encrusted stents according to the Clavien-Dindo system specific to urological procedures and identify the factors leading to high-grade(Clavien-Dindo Grade 4A or above)complications.Methods:The hospital records of patients with forgotten encrusted double-J stents over a period of 8 years were reviewed.The parameters recorded included patient demographics,indwelling time,need for percutaneous nephrostomy,hemodialysis,urine culture,blood culture,total blood counts,serum creatinine,radiologic findings,management techniques,number of surgical interventions,modified Clavien-Dindo complications,follow-up,and mortality,if any.Results:Forty patients were included in the study.The median age was 52(range 6-85)years.Of the total,25(62.5%)patients had a“significant”stent load;31(77.5%)had renal failure or acute kidney injury on presentation;19(47.5%)patients had sepsis at presentation.Among the patients presented with sepsis,11(57.9%)patients demonstrated a positive urine culture;and 7/11(63.6%)patients exhibited pan-resistant organisms.Twelve out of 40(30.0%)patients in our series developed high-grade Clavien-Dindo complications.On univariate analysis,sepsis at presentation(p=0.007),stent load(p=0.031),diabetes(p=0.023),positive urine culture(p=0.007),and stent indwelling time of more than 1 year(p=0.031)were found to be significant.On multivariate logistic regression analysis,sepsis at presentation(p=0.017)and positive urine culture(p=0.016)were significant predictors for high-grade complications.Conclusion:It is prudent to identify specific risk factors,namely sepsis at presentation and positive urine culture to triage and optimize these patients before surgical management. 展开更多
关键词 Forgotten Encrusted stent Outcome Predictor Clavien-Dindo complication
下载PDF
Exosomes:the next-generation therapeutic platform for ischemic stroke
14
作者 Wenjing Yin Hongyin Ma +4 位作者 Yang Qu Jiaxin Ren Yingying Sun Zhen-Ni Guo Yi Yang 《Neural Regeneration Research》 SCIE CAS 2025年第5期1221-1235,共15页
Current therapeutic strategies for ischemic stroke fall short of the desired objective of neurological functional recovery.Therefore,there is an urgent need to develop new methods for the treatment of this condition.E... Current therapeutic strategies for ischemic stroke fall short of the desired objective of neurological functional recovery.Therefore,there is an urgent need to develop new methods for the treatment of this condition.Exosomes are natural cell-derived vesicles that mediate signal transduction between cells under physiological and pathological conditions.They have low immunogenicity,good stability,high delivery efficiency,and the ability to cross the blood–brain barrier.These physiological properties of exosomes have the potential to lead to new breakthroughs in the treatment of ischemic stroke.The rapid development of nanotechnology has advanced the application of engineered exosomes,which can effectively improve targeting ability,enhance therapeutic efficacy,and minimize the dosages needed.Advances in technology have also driven clinical translational research on exosomes.In this review,we describe the therapeutic effects of exosomes and their positive roles in current treatment strategies for ischemic stroke,including their antiinflammation,anti-apoptosis,autophagy-regulation,angiogenesis,neurogenesis,and glial scar formation reduction effects.However,it is worth noting that,despite their significant therapeutic potential,there remains a dearth of standardized characterization methods and efficient isolation techniques capable of producing highly purified exosomes.Future optimization strategies should prioritize the exploration of suitable isolation techniques and the establishment of unified workflows to effectively harness exosomes for diagnostic or therapeutic applications in ischemic stroke.Ultimately,our review aims to summarize our understanding of exosome-based treatment prospects in ischemic stroke and foster innovative ideas for the development of exosome-based therapies. 展开更多
关键词 blood–brain barrier ELECTROACUPUNCTURE engineering exercise EXOSOMES ischemic stroke mesenchymal stem cells MICROGLIA NEUROPROTECTION STENTS
下载PDF
Percutaneous nephrostomy versus ureteral stent in hydronephrosis secondary to obstructive urolithiasis:A systematic review and meta-analysis
15
作者 Andreia Cardoso Aparício Coutinho +6 位作者 Gonçalo Neto Sara Anacleto Catarina Laranjo Tinoco Nuno Morais Mário Cerqueira-Alves Estevão Lima Paulo Mota 《Asian Journal of Urology》 CSCD 2024年第2期261-270,共10页
Objective: To assess if there is a preferable intervention between retrograde ureteral stent (RUS) and percutaneous nephrostomy (PCN) tube, in cases of upper urinary tract stone obstruction with complications requirin... Objective: To assess if there is a preferable intervention between retrograde ureteral stent (RUS) and percutaneous nephrostomy (PCN) tube, in cases of upper urinary tract stone obstruction with complications requiring urgent drainage, by evaluating outcomes regarding urinary symptoms, quality of life (QoL), spontaneous stone passage, and length of hospital stays, since there is no literature stating the superiority of one modality over the other.Methods: We searched MEDLINE and other sources for relevant articles in June 2019 without any date restrictions or filters applied. The selection was done first by the title and abstract screening and then by full-text assessment for eligibility. Only randomized controlled trials or cohort studies in patients with hydronephrosis secondary to obstructive urolithiasis that presented comparative data between PCN and RUS placement concerning at least one of the defined outcome measures were included. Lastly, MEDLINE database and PubMed platform were screened again using the same terms, from June 2019 until November 2022.Results: Of 556 initial articles, seven were included in this review. Most works were considered of moderate-to-high quality. Three studies regarding QoL showed a tendency against stenting, even though only one demonstrated statistically significant negative impact on overall health state. Two works reported significantly more post-intervention urinary symptoms in stenting patients. One article found that PCN is a significant predictor of spontaneous stone passage, when adjusted for stone size and location. Findings on length of hospital stays were not consistent among articles.Conclusion: PCN appears to be the intervention better tolerated, with less impact on the patient’s perceived QoL and less post-operative urinary symptoms, in comparison with RUS. Nevertheless, further studies with larger samples and a randomized controlled design are suggested. 展开更多
关键词 Ureteral stent Percutaneous nephrostomy Obstructive urolithiasis Urinary symptoms Quality of life
下载PDF
Defining failure of endoluminal biliary drainage in the era of endoscopic ultrasound and lumen apposing metal stents
16
作者 Faisal S Ali Sushovan Guha 《World Journal of Gastroenterology》 SCIE CAS 2024年第29期3534-3537,共4页
The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stent... The role of endoscopy in pathologies of the bile duct and gallbladder has seen notable advancements over the past two decades.With advancements in stent technology,such as the development of lumen-apposing metal stents,and adoption of endoscopic ultrasound and electrosurgical principles in therapeutic endoscopy,what was once considered endoscopic failure has transformed into failure of an approach that could be salvaged by a second-or third-line endoscopic strategy.Incorporation of these advancements in routine patient care will require formal training and multidisciplinary acceptance of established techniques and collaboration for advancement of experimental techniques to generate robust evidence that can be utilized to serve patients to the best of our ability. 展开更多
关键词 Endoscopic ultrasound Guided biliary drainage GALLBLADDER Biliary obstruction Lumen-apposing metal stent
下载PDF
Numerical Study of the Biomechanical Behavior of a 3D Printed Polymer Esophageal Stent in the Esophagus by BP Neural Network Algorithm
17
作者 Guilin Wu Shenghua Huang +7 位作者 Tingting Liu Zhuoni Yang Yuesong Wu Guihong Wei Peng Yu Qilin Zhang Jun Feng Bo Zeng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2709-2725,共17页
Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinica... Esophageal disease is a common disorder of the digestive system that can severely affect the quality of life andprognosis of patients. Esophageal stenting is an effective treatment that has been widely used in clinical practice.However, esophageal stents of different types and parameters have varying adaptability and effectiveness forpatients, and they need to be individually selected according to the patient’s specific situation. The purposeof this study was to provide a reference for clinical doctors to choose suitable esophageal stents. We used 3Dprinting technology to fabricate esophageal stents with different ratios of thermoplastic polyurethane (TPU)/(Poly-ε-caprolactone) PCL polymer, and established an artificial neural network model that could predict the radial forceof esophageal stents based on the content of TPU, PCL and print parameter. We selected three optimal ratios formechanical performance tests and evaluated the biomechanical effects of different ratios of stents on esophagealimplantation, swallowing, and stent migration processes through finite element numerical simulation and in vitrosimulation tests. The results showed that different ratios of polymer stents had different mechanical properties,affecting the effectiveness of stent expansion treatment and the possibility of postoperative complications of stentimplantation. 展开更多
关键词 Finite element method 3D printing polymer esophageal stent artificial neural network
下载PDF
Vertebral Artery Stenting for Acute Multiple Cerebral Infarctions Caused by Vertebral Artery Dissection After Massage:A Case Report
18
作者 Ying-Xue Cui Chuan-Jin Song +3 位作者 Xue-Si Hou Gui-Lin Liu Xu Ji Shao-Song Wang 《Chinese Medical Sciences Journal》 CAS CSCD 2024年第2期149-154,共6页
Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 3... Vertebral artery dissection is a rare pathology that can cause ischemic stroke in young people.Cervical massage,especially improper pulling manipulation,is a cause of vertebral artery dissection.We present a case of 32-year old woman who developed acute multiple posterior circulation ischemic cerebral infarctions as a result of left vertebral artery V4 segment dissection after receiving neck massage.She underwent emergency vertebral artery stent implantation at the site of the dissection.Symptoms were relieved the day after treatment.The patient recovered without adverse complications or endovascular restenosis in the following year. 展开更多
关键词 vertebral artery dissection acute ischemic stroke stent implantation endovascular therapy
下载PDF
Bioresorbable stent unloading during percutaneous coronary intervention:Early detection and management
19
作者 Nabil Eid Mohamed Abdel Wahab Amardev Singh Thanu 《World Journal of Cardiology》 2024年第10期616-618,共3页
In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable st... In this letter,we comment on a recent case report by Sun et al in the World Journal of Cardiology.The report describes the successful management of a rare complication:The unloading or detachment of a bioresorbable stent(BRS)during percutaneous coronary intervention(PCI)in a male patient.The unloading of BRS was detected via angiography and intravascular ultrasound(IVUS)imaging of the left coronary artery and left anterior descending artery.Although this case is interesting,the authors’report lacked crucial details.Specifically,insufficient information about the type of BRS used,potential causes of BRS unloading,or whether optical coherence tomography(OCT)imaging for coronary arteries was performed before,during,or after PCI.The OCT imaging of coronary arteries before PCI can potentially prevent BRS unloading due to its higher resolution compared to IVUS.In addition,despite detecting myocardial bridging during the PCI,the authors did not provide any details regarding this variation.Here we discuss the various types of BRS,the importance of OCT in PCI,and the clinical relevance of myocardial bridging. 展开更多
关键词 Coronary artery diseases Percutaneous coronary intervention Optical coherence tomography Bioresorbable/Biodegradable stents Stent unloading/detachment Myocardial bridge Intravascular ultrasound Coronary angiography
下载PDF
Self-expanding metal stent for relieving the stricture after endoscopic injection for esophageal varices
20
作者 Fu-Long Zhang Jing Xu +8 位作者 Yu-Hong Jiang Yuan-Dong Zhu Yan Shi Xiao Li Hai Wang Chao-Jun Huang Chun-Hua Zhou Qun Zhu Jing-Wen Chen 《World Journal of Clinical Cases》 SCIE 2024年第28期6180-6186,共7页
BACKGROUND Esophageal stricture is one of the complications after esophageal varices sclero-therapy injection(ESI),and the incidence rate is between 2%-10%.AIM To explore the efficacy of self-expanding metal stent(SEM... BACKGROUND Esophageal stricture is one of the complications after esophageal varices sclero-therapy injection(ESI),and the incidence rate is between 2%-10%.AIM To explore the efficacy of self-expanding metal stent(SEMS)for the stricture after endoscopic injection with cyanoacrylate(CYA)and sclerotherapy for esophageal varices.METHODS We retrospectively analyzed the efficacy of SEMS to improve the stricture after endoscopic injection with CYA and sclerotherapy for esophageal varices in 4 patients from February 2023 to June 2023.RESULTS The strictures were improved in four patients after stenting.The stent was removed after two weeks because of chest pain with embedding into esophageal mucosa in one patient.The stent was removed after one month,however,the stent was reinserted because of the strictures happening again in two patients.The stent was removed after three months,however,the stent was reinserted because of the strictures happening again in one patient.The stent embedded into esophageal mucosa in three patients.There were 3 patients suffered reflux esophagitis,and the acid reflux was relieved by taking hydrotalcite.There was no other complication of esophageal perforation,bleeding from varices or infection.CONCLUSION SEMS may relieve the stricture which happened after endoscopic injection with CYA and sclerotherapy for esophageal varices.However,when we should remove the stent still needs to be explored. 展开更多
关键词 STENT STRICTURE Endoscopic injection Esophageal varices CYANOACRYLATE SCLEROTHERAPY
下载PDF
上一页 1 2 75 下一页 到第
使用帮助 返回顶部