The aerodynamic resistance of a train running in the open air limits the maximum speed that can be attained by the train.For this reason,evacuated tube trains(ETT)are being considered as valid alternatives to be imple...The aerodynamic resistance of a train running in the open air limits the maximum speed that can be attained by the train.For this reason,evacuated tube trains(ETT)are being considered as valid alternatives to be implemented in the future.The atmosphere in the tube,the so-called blocking ratio and the length of the streamlined nose are the key factors affecting the aerodynamic performances of these trains.In the present work,we investigate evacuated tube trains with different lengths of the streamline nose on the basis of computational fluid dynamics(CFD).The three-dimensional steady compressible Navier-Stokes equations are solved.The running speed of the ETT is 800 km/h and the blocking ratio is 0.2.Results show that with the increase of the streamlined nose length,the aerodynamic drag and lift forces of the head car decrease gradually,and the drag and lift forces of the middle car change slightly.For the tail car,the drag force decreases,whereas the absolute value of the lift force increases.At a speed of 800 km/h,a slight shock wave appears at the rear of the tail car,which affects the aerodynamic forces acting on the train.展开更多
Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis dur...Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis during blood delivery.In this paper,a new valveless piezoelectric(PZT)pump with streamlined flow tubes(streamlined pump)is proposed.The design method and the working principle of the pump are analyzed.The velocity streamlines are simulated,and the results demonstrate that there are no obvious vortexes in the flow tube of the streamlined pump.Five prototype pumps(two cone pumps and three streamlined pumps)are designed and fabricated to perform flow rate and flow resistance experiments.The experimental results illustrate that the maximum flow rate of the streamlined pump is 142 mL/min,which is 179%higher than that of the cone piezoelectric pump,demonstrating that the streamlined pump has a large flow rate performance.This research provides an inspiration for future research on simple structure,low vortex and large flow rate volume-type pumps,and also provides a useful solution for thrombosis preventing.展开更多
In foundries a lot of effort is done to minimize energy consumption in the production to reduce costs and hence increase the competitiveness. At the same time the foundries must live up to the increased demands for hi...In foundries a lot of effort is done to minimize energy consumption in the production to reduce costs and hence increase the competitiveness. At the same time the foundries must live up to the increased demands for high quality castings. Traditional gating systems are known for a straight tapered down runner, a well base and 90° bends in the runner system. Previous work has shown that the traditional way of designing gating systems creates high inconsistency in flow patterns during filling. In the streamlined gating systems there are no sharp changes in direction and a large effort is done to confine and control the flow of the molten metal during mould filling. The main objective in the work presented here is to use the principles of the streamlined gating systems to reduce the weight of the gating system relative to the traditional layouts. By reducing the weight of gating system and thereby improving yield, the amount of molten iron needed is also reduced, hence reducing the energy consumption for melting. Experiments in real production lines have proven that it is possible to achieve a reduction in the poured weight by using the streamlined gating systems. In a layout for casting of three valve housings in a vertically parted mould the weight of the gating system was reduced by 1.1 kg changing from the traditional layouts to the streamlined gating systems. This weight reduction corresponds in this case to a 20% weight reduction for the gating system. Using streamlined gating systems with fan gates to give a beneficial heat distribution in the castings may be an efficient tool to eliminate the need for heat treatment. In the experiments the change in gating system from the traditional layout to the streamlined layout removed the need for heat treatment. This obviously means a huge energy saving in the foundry. The energy consumption for heat treatment of iron has been found to be 0.489 kWh/ kg. The valve housing in the experiments weighs 3 kg so when the need for heat treatment is removed, around 1.5 kWh is saved per casting. Along with the reduction in energy used the foundry also save the cost of handling the castings for the heat treatment and the production times is reduced considerably When the moulds for the vertical layout is produced on a DISAMATIC that produces 350 moulds an hour the total energy saved per hour for both melting and heat treatment becomes 2,000 kWh and per eight hour work day 16,000 kWh. Seen in this perspective the potential for saving energy in the foundries is substantial. Furthermore the experiments where ductile iron valve housings was cast also proved that it is possible to lower the pouring temperature from 1,400℃ to 1,300℃ without the risk of cold runs. This is possible due to a high flow rate during mould filling in combination with low velocities due to the use of fan gates. All of this has also been investigated in experiments using glass plate fronted moulds.展开更多
WANG Xianlong didn't expect it would take only five working days to register his business, an outdoor products company based in Yiwu, a city in east China's Zhejiang Province. "Previously, getting administrative ap...WANG Xianlong didn't expect it would take only five working days to register his business, an outdoor products company based in Yiwu, a city in east China's Zhejiang Province. "Previously, getting administrative approval used to take at least three weeks." Wang said. "1 would have to go back and forth between several government departments. But now, the Yiwu Administration Service Center offers a onestop service for enterprises. It's much faster."展开更多
Brazilian pre-salt reservoirs are renowned for their intricate pore networks and vuggy nature,posing significant challenges in modeling and simulating fluid flow within these carbonate reservoirs.Despite possessing ex...Brazilian pre-salt reservoirs are renowned for their intricate pore networks and vuggy nature,posing significant challenges in modeling and simulating fluid flow within these carbonate reservoirs.Despite possessing excellent petrophysical properties,such as high porosity and permeability,these reservoirs typically exhibit a notably low recovery factor,sometimes falling below 10%.Previous research has indicated that various enhanced oil recovery(EOR)methods,such as water alternating gas(WAG),can substantially augment the recovery factor in pre-salt reservoirs,resulting in improvements of up to 20%.Nevertheless,the fluid flow mechanism within Brazilian carbonate reservoirs,characterized by complex pore geometry,remains unclear.Our study examines the behavior of fluid flow in a similar heterogeneous porous material,utilizing a plug sample obtained from a vugular segment of a Brazilian stromatolite outcrop,known to share analogies with certain pre-salt reservoirs.We conducted single-phase and multi-phase core flooding experiments,complemented by medical-CT scanning,to generate flow streamlines and evaluate the efficiency of water flooding.Subsequently,micro-CT scanning of the core sample was performed,and two cross-sections from horizontal and vertical plates were constructed.These cross-sections were then employed as geometries in a numerical simulator,enabling us to investigate the impact of pore geometry on fluid flow.Analysis of the pore-scale modeling and experimental data unveiled that the presence of dead-end pores and vugs results in a significant portion of the fluid remaining stagnant within these regions.Consequently,the injected fluid exhibits channeling-like behavior,leading to rapid breakthrough and low areal swept efficiency.Additionally,the numerical simulation results demonstrated that,irrespective of the size of the dead-end regions,the pressure variation within the dead-end vugs and pores is negligible.Despite the stromatolite's favorable petrophysical properties,including relatively high porosity and permeability,as well as the presence of interconnected large vugs,the recovery factor during water flooding remained low due to early breakthrough.These findings align with field data obtained from pre-salt reservoirs,providing an explanation for the observed low recovery factor during water flooding in such reservoirs.展开更多
基金supported by Sichuan Science and Technology Program(No.2019YJ0227)China Postdoctoral Science Foundation(No.2019M663550)+1 种基金National Natural Science Foundation of China(No.51605397)Science and Technolgoy program of China Railway Group Limited(No.2018-S-02).
文摘The aerodynamic resistance of a train running in the open air limits the maximum speed that can be attained by the train.For this reason,evacuated tube trains(ETT)are being considered as valid alternatives to be implemented in the future.The atmosphere in the tube,the so-called blocking ratio and the length of the streamlined nose are the key factors affecting the aerodynamic performances of these trains.In the present work,we investigate evacuated tube trains with different lengths of the streamline nose on the basis of computational fluid dynamics(CFD).The three-dimensional steady compressible Navier-Stokes equations are solved.The running speed of the ETT is 800 km/h and the blocking ratio is 0.2.Results show that with the increase of the streamlined nose length,the aerodynamic drag and lift forces of the head car decrease gradually,and the drag and lift forces of the middle car change slightly.For the tail car,the drag force decreases,whereas the absolute value of the lift force increases.At a speed of 800 km/h,a slight shock wave appears at the rear of the tail car,which affects the aerodynamic forces acting on the train.
基金supported by the National Natural Science Foundation of China (No. 51375227)the Introduction of Talent Research Start-up Fund of Nanjing Institute of Technology(No. YKJ201960).
文摘Valveless piezoelectric pump is widely used in the medical,however,there is a general and difficult problem to be solved:Low vortex and large flow rate are not compatible,resulting in the blood prone to thrombosis during blood delivery.In this paper,a new valveless piezoelectric(PZT)pump with streamlined flow tubes(streamlined pump)is proposed.The design method and the working principle of the pump are analyzed.The velocity streamlines are simulated,and the results demonstrate that there are no obvious vortexes in the flow tube of the streamlined pump.Five prototype pumps(two cone pumps and three streamlined pumps)are designed and fabricated to perform flow rate and flow resistance experiments.The experimental results illustrate that the maximum flow rate of the streamlined pump is 142 mL/min,which is 179%higher than that of the cone piezoelectric pump,demonstrating that the streamlined pump has a large flow rate performance.This research provides an inspiration for future research on simple structure,low vortex and large flow rate volume-type pumps,and also provides a useful solution for thrombosis preventing.
文摘In foundries a lot of effort is done to minimize energy consumption in the production to reduce costs and hence increase the competitiveness. At the same time the foundries must live up to the increased demands for high quality castings. Traditional gating systems are known for a straight tapered down runner, a well base and 90° bends in the runner system. Previous work has shown that the traditional way of designing gating systems creates high inconsistency in flow patterns during filling. In the streamlined gating systems there are no sharp changes in direction and a large effort is done to confine and control the flow of the molten metal during mould filling. The main objective in the work presented here is to use the principles of the streamlined gating systems to reduce the weight of the gating system relative to the traditional layouts. By reducing the weight of gating system and thereby improving yield, the amount of molten iron needed is also reduced, hence reducing the energy consumption for melting. Experiments in real production lines have proven that it is possible to achieve a reduction in the poured weight by using the streamlined gating systems. In a layout for casting of three valve housings in a vertically parted mould the weight of the gating system was reduced by 1.1 kg changing from the traditional layouts to the streamlined gating systems. This weight reduction corresponds in this case to a 20% weight reduction for the gating system. Using streamlined gating systems with fan gates to give a beneficial heat distribution in the castings may be an efficient tool to eliminate the need for heat treatment. In the experiments the change in gating system from the traditional layout to the streamlined layout removed the need for heat treatment. This obviously means a huge energy saving in the foundry. The energy consumption for heat treatment of iron has been found to be 0.489 kWh/ kg. The valve housing in the experiments weighs 3 kg so when the need for heat treatment is removed, around 1.5 kWh is saved per casting. Along with the reduction in energy used the foundry also save the cost of handling the castings for the heat treatment and the production times is reduced considerably When the moulds for the vertical layout is produced on a DISAMATIC that produces 350 moulds an hour the total energy saved per hour for both melting and heat treatment becomes 2,000 kWh and per eight hour work day 16,000 kWh. Seen in this perspective the potential for saving energy in the foundries is substantial. Furthermore the experiments where ductile iron valve housings was cast also proved that it is possible to lower the pouring temperature from 1,400℃ to 1,300℃ without the risk of cold runs. This is possible due to a high flow rate during mould filling in combination with low velocities due to the use of fan gates. All of this has also been investigated in experiments using glass plate fronted moulds.
文摘WANG Xianlong didn't expect it would take only five working days to register his business, an outdoor products company based in Yiwu, a city in east China's Zhejiang Province. "Previously, getting administrative approval used to take at least three weeks." Wang said. "1 would have to go back and forth between several government departments. But now, the Yiwu Administration Service Center offers a onestop service for enterprises. It's much faster."
基金the support of EPIC-Energy Production Innovation Center,hosted by the University of Campinas(UNICAMP)sponsored by FAPESP-Sao Paulo Research Foundation(2017/15736e3 process).
文摘Brazilian pre-salt reservoirs are renowned for their intricate pore networks and vuggy nature,posing significant challenges in modeling and simulating fluid flow within these carbonate reservoirs.Despite possessing excellent petrophysical properties,such as high porosity and permeability,these reservoirs typically exhibit a notably low recovery factor,sometimes falling below 10%.Previous research has indicated that various enhanced oil recovery(EOR)methods,such as water alternating gas(WAG),can substantially augment the recovery factor in pre-salt reservoirs,resulting in improvements of up to 20%.Nevertheless,the fluid flow mechanism within Brazilian carbonate reservoirs,characterized by complex pore geometry,remains unclear.Our study examines the behavior of fluid flow in a similar heterogeneous porous material,utilizing a plug sample obtained from a vugular segment of a Brazilian stromatolite outcrop,known to share analogies with certain pre-salt reservoirs.We conducted single-phase and multi-phase core flooding experiments,complemented by medical-CT scanning,to generate flow streamlines and evaluate the efficiency of water flooding.Subsequently,micro-CT scanning of the core sample was performed,and two cross-sections from horizontal and vertical plates were constructed.These cross-sections were then employed as geometries in a numerical simulator,enabling us to investigate the impact of pore geometry on fluid flow.Analysis of the pore-scale modeling and experimental data unveiled that the presence of dead-end pores and vugs results in a significant portion of the fluid remaining stagnant within these regions.Consequently,the injected fluid exhibits channeling-like behavior,leading to rapid breakthrough and low areal swept efficiency.Additionally,the numerical simulation results demonstrated that,irrespective of the size of the dead-end regions,the pressure variation within the dead-end vugs and pores is negligible.Despite the stromatolite's favorable petrophysical properties,including relatively high porosity and permeability,as well as the presence of interconnected large vugs,the recovery factor during water flooding remained low due to early breakthrough.These findings align with field data obtained from pre-salt reservoirs,providing an explanation for the observed low recovery factor during water flooding in such reservoirs.