In Britton-Robinson buffer,metronidazole is preconcentreted on HHDE at 0.0 V(Vs.Ag- AgCI),An adsorptive stripping peak is observed at-0.62 V.Tho response is linear from 1x10^(-8)to 1×10^(-6)mol/L with 1.5 min acc...In Britton-Robinson buffer,metronidazole is preconcentreted on HHDE at 0.0 V(Vs.Ag- AgCI),An adsorptive stripping peak is observed at-0.62 V.Tho response is linear from 1x10^(-8)to 1×10^(-6)mol/L with 1.5 min accumulation.The method has been successfully applied to the deternation of metronidazole in human serum and formulations.展开更多
This paper describes a stripping method for the determination of zidovudine at the submicromolar concentration levels. This method is based on the controlled adsorptive accumulation of zidovudine at the thin-film merc...This paper describes a stripping method for the determination of zidovudine at the submicromolar concentration levels. This method is based on the controlled adsorptive accumulation of zidovudine at the thin-film mercury electrode, followed by a linear-sweep stripping voltammetry measurement of the surface species. Optimal experimental conditions include a NaOH solution of 2.0 × 10–3 mol●L–1 (sup-porting electrolyte), an accumulation potential of –0.30 V and a scan rate of 100 mV?s–1. The response of zidovudine is linear over the concentration range 0.01 - 0.08 ppm. After an accumulation time of 5 minutes, the detection limit was found to be 0.67 ppb (2.5 × 10–9 mol●L–1). More convenient methods to measure zidovudine concentration in the presence of the didanosine, acyclovir, nevirapine, lamivudine, and efavirenz, were also investigated. The presence of zidovudine together with ATP or ssDNA demonstrates the utility of this method.展开更多
A stripping method for the determination of hypoxanthine in the presence of copper at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation of hypoxanthine-copp...A stripping method for the determination of hypoxanthine in the presence of copper at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation of hypoxanthine-copper at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10﹣3 mol·L﹣1 NaOH solution as electrolyte supporting, an accumulation potential of ﹣0.50 V and a linear scan rate of 200 mV·s﹣1. The response of hypoxanthine-copper is linear over the concentration ranges of 10 - 60 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 250 ppt (1.8 × 10﹣9 mol·L﹣1). Adequate conditions for measuring the hypoxanthine in the presence of metal ions, xanthine, uric acid and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of hypoxanthine associated in ATP or ssDNA.展开更多
The cyclic voltammetry (CV) and the semidifferential anodic stripping voltammetry (SdASV) were used for investigation of bismuth(III) underpotential deposition (UPD) on gold electrode. Based on the excellent electro...The cyclic voltammetry (CV) and the semidifferential anodic stripping voltammetry (SdASV) were used for investigation of bismuth(III) underpotential deposition (UPD) on gold electrode. Based on the excellent electrochemical properties of Au/Bi UPD system, a new method for determining bismuth(III) was established. A solution of 0.1 mol/L HNO 3 was selected as the supporting electrolyte. Factors affecting the Bi(III) UPD and stripping steps were investigated and an optimized analytical procedure was developed. The calibration plots for Bi(III) concentration in the range 1.25×10 -8 -1.0×10 -7 mol/L were obtained. The detection limit, calculated as three times the standard deviation of the analytical signal of 8.3×10 -8 mol/L for a 90 s electrodeposition at 0.00 V (while the solution magnetically stirred at a speed of 300 rpm), was 7.5×10 -9 mol/ L. For 8 successive determinations of 1.25×10 -7 mol/L Bi(III), the obtained RSD (relative standard deviation) was 0.4%. The developed method was applied to bismuth determining in medicine and urine samples. The analytical results were compared with that of atomic emission spectrometry (AES) method.展开更多
文摘In Britton-Robinson buffer,metronidazole is preconcentreted on HHDE at 0.0 V(Vs.Ag- AgCI),An adsorptive stripping peak is observed at-0.62 V.Tho response is linear from 1x10^(-8)to 1×10^(-6)mol/L with 1.5 min accumulation.The method has been successfully applied to the deternation of metronidazole in human serum and formulations.
文摘This paper describes a stripping method for the determination of zidovudine at the submicromolar concentration levels. This method is based on the controlled adsorptive accumulation of zidovudine at the thin-film mercury electrode, followed by a linear-sweep stripping voltammetry measurement of the surface species. Optimal experimental conditions include a NaOH solution of 2.0 × 10–3 mol●L–1 (sup-porting electrolyte), an accumulation potential of –0.30 V and a scan rate of 100 mV?s–1. The response of zidovudine is linear over the concentration range 0.01 - 0.08 ppm. After an accumulation time of 5 minutes, the detection limit was found to be 0.67 ppb (2.5 × 10–9 mol●L–1). More convenient methods to measure zidovudine concentration in the presence of the didanosine, acyclovir, nevirapine, lamivudine, and efavirenz, were also investigated. The presence of zidovudine together with ATP or ssDNA demonstrates the utility of this method.
文摘A stripping method for the determination of hypoxanthine in the presence of copper at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation of hypoxanthine-copper at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10﹣3 mol·L﹣1 NaOH solution as electrolyte supporting, an accumulation potential of ﹣0.50 V and a linear scan rate of 200 mV·s﹣1. The response of hypoxanthine-copper is linear over the concentration ranges of 10 - 60 ppb. For an accumulation time of 30 minutes, the detection limit was found to be 250 ppt (1.8 × 10﹣9 mol·L﹣1). Adequate conditions for measuring the hypoxanthine in the presence of metal ions, xanthine, uric acid and other nitrogenated bases were also investigated. The utility of the method is demonstrated by the presence of hypoxanthine associated in ATP or ssDNA.
文摘The cyclic voltammetry (CV) and the semidifferential anodic stripping voltammetry (SdASV) were used for investigation of bismuth(III) underpotential deposition (UPD) on gold electrode. Based on the excellent electrochemical properties of Au/Bi UPD system, a new method for determining bismuth(III) was established. A solution of 0.1 mol/L HNO 3 was selected as the supporting electrolyte. Factors affecting the Bi(III) UPD and stripping steps were investigated and an optimized analytical procedure was developed. The calibration plots for Bi(III) concentration in the range 1.25×10 -8 -1.0×10 -7 mol/L were obtained. The detection limit, calculated as three times the standard deviation of the analytical signal of 8.3×10 -8 mol/L for a 90 s electrodeposition at 0.00 V (while the solution magnetically stirred at a speed of 300 rpm), was 7.5×10 -9 mol/ L. For 8 successive determinations of 1.25×10 -7 mol/L Bi(III), the obtained RSD (relative standard deviation) was 0.4%. The developed method was applied to bismuth determining in medicine and urine samples. The analytical results were compared with that of atomic emission spectrometry (AES) method.