Based on ANSYS software, a finite element model is built for the fatigue break of a vibration feeder influenced by an exciting force alternate load. We first study the harmonic response of the feeder and discovers the...Based on ANSYS software, a finite element model is built for the fatigue break of a vibration feeder influenced by an exciting force alternate load. We first study the harmonic response of the feeder and discovers the weak links which is an angle steel junction of side plate, feed inlet and the junction panel between the no-feed side plate and the bottom plate. Then, we carry out structural optimization. A streamlined method for optimum design of a vibration feeder is presented.展开更多
Rotary tool of garbage crusher is the key component of the whole mechanism, which is of vital importance to tool design and analysis. Based on ANSYS Workbench 3D modeling, we carried on finite element analysis to tool...Rotary tool of garbage crusher is the key component of the whole mechanism, which is of vital importance to tool design and analysis. Based on ANSYS Workbench 3D modeling, we carried on finite element analysis to tool, and used the method of goal driven optimization to optimize the rotary tool. The optimization proves that the optimized maximum equivalent stress is 544.14 MPa, the quality is less, and the optimized rotary tool size is more reasonable. So it provided reasonable and scientific reference frame to the structural design of rotary tool.展开更多
Height limitations are not uncommon in multi-storey buildings due to economic requirements and esthetical considerations. Substantial spaces are normally required to enable the passage of large pipes and ducts beneath...Height limitations are not uncommon in multi-storey buildings due to economic requirements and esthetical considerations. Substantial spaces are normally required to enable the passage of large pipes and ducts beneath steel beams leading to uneconomic floor heights. The most adopted solution for this issue is the use of steel beam web openings to provide the required space for services. These openings could lead to a significant decrease of the beam load carrying capacity depending on the adopted openings shape, size and location. These aspects motivated the present study based on FE simulations calibrated against numerical and test results. The results accuracy enabled a comprehensive parametric analysis of beams with web openings to be made focused on the profile size, web opening location, among others. The study also investigated the efficiency of longitudinal stiffeners welded at the opening region and benefits of using an adequate edge concordance radius in beams with rectangular and square openings. The obtained results showed the need of using welded longitudinal stiffeners in order to increase the beams ultimate load carrying capacity. This adoption can double or even triple the ultimate load of beams with rectangular and square opening heights equal to 0.75 H, respectively.展开更多
文摘Based on ANSYS software, a finite element model is built for the fatigue break of a vibration feeder influenced by an exciting force alternate load. We first study the harmonic response of the feeder and discovers the weak links which is an angle steel junction of side plate, feed inlet and the junction panel between the no-feed side plate and the bottom plate. Then, we carry out structural optimization. A streamlined method for optimum design of a vibration feeder is presented.
文摘Rotary tool of garbage crusher is the key component of the whole mechanism, which is of vital importance to tool design and analysis. Based on ANSYS Workbench 3D modeling, we carried on finite element analysis to tool, and used the method of goal driven optimization to optimize the rotary tool. The optimization proves that the optimized maximum equivalent stress is 544.14 MPa, the quality is less, and the optimized rotary tool size is more reasonable. So it provided reasonable and scientific reference frame to the structural design of rotary tool.
文摘Height limitations are not uncommon in multi-storey buildings due to economic requirements and esthetical considerations. Substantial spaces are normally required to enable the passage of large pipes and ducts beneath steel beams leading to uneconomic floor heights. The most adopted solution for this issue is the use of steel beam web openings to provide the required space for services. These openings could lead to a significant decrease of the beam load carrying capacity depending on the adopted openings shape, size and location. These aspects motivated the present study based on FE simulations calibrated against numerical and test results. The results accuracy enabled a comprehensive parametric analysis of beams with web openings to be made focused on the profile size, web opening location, among others. The study also investigated the efficiency of longitudinal stiffeners welded at the opening region and benefits of using an adequate edge concordance radius in beams with rectangular and square openings. The obtained results showed the need of using welded longitudinal stiffeners in order to increase the beams ultimate load carrying capacity. This adoption can double or even triple the ultimate load of beams with rectangular and square opening heights equal to 0.75 H, respectively.