期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Effects of Seasonal Variations in Physical Parameters on Quality of Gravity Flow Water in Kyanamira Sub-County, Kabale District, Uganda
1
作者 Hannington Ngabirano Denis Byamugisha Emmanuel Ntambi 《Journal of Water Resource and Protection》 2016年第13期1297-1309,共13页
The effect of seasonal variations in physical parameters on quality of gravity flow water was investigated in Kyanamira Sub-County, Kabale District, Uganda. The seasonal variations in the physical parameters (pH, temp... The effect of seasonal variations in physical parameters on quality of gravity flow water was investigated in Kyanamira Sub-County, Kabale District, Uganda. The seasonal variations in the physical parameters (pH, temperature, electrical conductivity (EC), turbidity, colour, total dissolved solids (TDS), and total suspended solids (TSS)) were determined during wet and dry seasons. Composite samples from gravity flow water sources were collected monthly from March to August, 2014 and then analyzed. Temperature was measured using thermometer;pH, EC and TDS were determined using a multimeter, turbidity, colour and total suspended solids were determined by spectrophotometric method. TDS, pH and temperature were the most contributing parameters to water quality variations in both seasons. The mean pH values varied between 3.78 - 4.84 from March to August, 2014 at all study sites. These pH values were consistently below the WHO permissible range of 6.5 - 8.5. Similarly, total suspended solids varied between 0.66 - 2.17 mg·L<sup>-1</sup> and were well above the recommended WHO limit of zero mg·L<sup>-1</sup> at all study sites. Turbidity mean values varied between 0.83 - 3.7 NTU and were outside the recommended limits of 3 NTU at Kigata (3.7 NTU) only. Temperatures (20.3°C - 21.15°C) for all the study sites were within the recommended limit of 20°C - 30°C in water for domestic purposes. The mean values of physical parameters for the wet season were: temperature (21.12°C), colour (12.5 PtCoU), turbidity (3.4 NTU), TDS (76.76 mg·L<sup>-1</sup>), TSS (2.13 mg·L<sup>-1</sup>), pH (4.19) and EC (152.7 μS·cm<sup>-1</sup>) were different from those of the dry season (temperature (20.99&#176C), colour (0.93 PtCoU), turbidity (0.53 NTU), TDS (77.33 mg·L<sup>-1</sup>), TSS (0.67 mg·L<sup>-1</sup>), pH (4.86) and EC (158.65 μS·cm<sup>-1</sup>). Basing on these findings above, it was evident to justify discouraging the use of gravity flow water at these study sites for domestic purposes without proper treatment. 展开更多
关键词 Kyanamira sub-county Seasonal Variations Gravity Flow Water Physical Parameters
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部