The penetration of new energy sources such as wind power is increasing,which consequently increases the occurrence rate of subsynchronous oscillation events.However,existing subsynchronous oscillation source-identific...The penetration of new energy sources such as wind power is increasing,which consequently increases the occurrence rate of subsynchronous oscillation events.However,existing subsynchronous oscillation source-identification methods primarily analyze fixed-mode oscillations and rarely consider time-varying features,such as frequency drift,caused by the random volatility of wind farms when oscillations occur.This paper proposes a subsynchronous oscillation sourcelocalization method that involves an enhanced short-time Fourier transform and a convolutional neural network(CNN).First,an enhanced STFT is performed to secure high-resolution time-frequency distribution(TFD)images from the measured data of the generation unit ports.Next,these TFD images are amalgamated to form a subsynchronous oscillation feature map that serves as input to the CNN to train the localization model.Ultimately,the trained CNN model realizes the online localization of subsynchronous oscillation sources.The effectiveness and accuracy of the proposed method are validated via multimachine system models simulating forced and natural oscillation events using the Power Systems Computer Aided Design platform.Test results show that the proposed method can localize subsynchronous oscillation sources online while considering unpredictable fluctuations in wind farms,thus providing a foundation for oscillation suppression in practical engineering scenarios.展开更多
Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the d...Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors ofrotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two hearings respectively are discovered. As the outer clearance of SFRB increases from 24 ~tm to 60 pro, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close.展开更多
Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of su...Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of subsynchronous oscillations(SSOs). The SSOs may cause significant harm to generator sets and power systems;thus, online monitoring and accurate alarms for power systems are crucial for their safe and stable operation. Phasor measurement units(PMUs) can realize the dynamic real-time monitoring of power systems. Based on PMU phasor measurements, this study proposes a method for SSO online monitoring and alarm implementation for the main station of a PMU. First, fast Fourier transform frequency spectrum analysis is performed on PMU current phasor amplitude data to obtain subsynchronous frequency components. Second, the support vector machine learning algorithm is trained to obtain the amplitude threshold and subsequently filter out safe components and retain harmful ones. Finally, the adaptive duration threshold is determined according to frequency susceptibility, amplitude attenuation, and energy accumulation to decide whether to transmit an alarm signal. Experiments based on field data verify the effectiveness of the proposed method.展开更多
The subsynchronous oscillations(SSOs)related to renewable generation seriously affect the stability and safety of the power systems.To realize the dynamic monitoring of SSOs by utilizing the high computational efficie...The subsynchronous oscillations(SSOs)related to renewable generation seriously affect the stability and safety of the power systems.To realize the dynamic monitoring of SSOs by utilizing the high computational efficiency and noise-resilient features of the matrix pencil method(MPM),this paper propos es an improved MPM-based parameter identification with syn chrophasors.The MPM is enhanced by the angular frequency fitting equations based on the characteristic polynomial coeffi cients of the matrix pencil to ensure the accuracy of the identi fied parameters,since the existing eigenvalue solution of the MPM ignores the angular frequency conjugation constraints of the two fundamental modes and two oscillation modes.Then,the identification and recovery of bad data are proposed by uti lizing the difference in temporal continuity of the synchropha sors before and after noise reduction.The proposed parameter identification is verified with synthetic,simulated,and actual measured phase measurement unit(PMU)data.Compared with the existing MPM,the improved MPM achieves better accuracy for parameter identification of each component in SSOs,better real-time performance,and significantly reduces the effect of bad data.展开更多
In this paper,proposals in the following arcas of turbogenerator torsionaloscillation(TTO)researches in China are presented:* Concerning the focal points of TTO studies;* Concerning the modelling and data acquisition ...In this paper,proposals in the following arcas of turbogenerator torsionaloscillation(TTO)researches in China are presented:* Concerning the focal points of TTO studies;* Concerning the modelling and data acquisition of TTO;* Concerning the computation and analysis of TTO transients;* Concerning the monitoring and analyzing devices of TTO;* Concerning the countermeasures against TTO.It is concluded that researches centered on torsional oscillations caused by system dis-turbances and switching events should begin the carlier the better.展开更多
At present,the direct drive permanent magnet synchronous generator(DD-PMSG)grid connected system based on virtual synchronous generator(VSG)control will experience power oscillation at sub synchronous frequencies.The ...At present,the direct drive permanent magnet synchronous generator(DD-PMSG)grid connected system based on virtual synchronous generator(VSG)control will experience power oscillation at sub synchronous frequencies.The mechanism and characteristics of this new type of sub-synchronous interaction(SSI)are not yet clear,and the system cannot recover to steady state solely based on the characteristics of VSG itself.Especially when connected to a weak current network,oscillations are more pronounced,affecting the stability of the system.In severe cases,the systemmay trigger shutdown protection and be disconnected from the network.Existing research has only analyzed the oscillation mechanism under this phenomenon and has not proposed corresponding control strategies.This article proposes aVSM control strategy based on the VSG control algorithm,which balances the dq axis component of voltage and current,and improves the voltage and current loop of VSG control to reduce the impact of sub-synchronous oscillation(SSO)on the power grid.In MATLAB/Simulink,a simulation model of the proposed control strategy was built to verify its correctness and effectiveness.展开更多
With the rapid development of wind power, wind turbines are accompanied by a large quantity of power electronic converters connected to the grid, causing changes in the characteristics of the power system and leading ...With the rapid development of wind power, wind turbines are accompanied by a large quantity of power electronic converters connected to the grid, causing changes in the characteristics of the power system and leading to increasingly serious sub-synchronous oscillation (SSO) problems, which urgently require the generalized classification and characterization of the emerging oscillation problems. This paper classifies and characterizes the emerging types of SSO caused by grid-connected wind turbines to address these issues. Finally, the impact of the typical system parameters changes on the oscillation pattern is analyzed in depth to provide effective support for the subsequent suppression and prevention of SSO.展开更多
双馈风电场经串补电容并网时,可能引发次同步控制相互作用(subsynchronous control interaction,SSCI),严重威胁系统安全稳定运行。通过在风机控制器中引入陷波器可有效阻断SSCI,然而固定参数陷波器难以适应实际系统中次同步振荡表现出...双馈风电场经串补电容并网时,可能引发次同步控制相互作用(subsynchronous control interaction,SSCI),严重威胁系统安全稳定运行。通过在风机控制器中引入陷波器可有效阻断SSCI,然而固定参数陷波器难以适应实际系统中次同步振荡表现出的频率大范围时变特征。为解决这一问题,该文提出一种基于改进自适应陷波(adaptive notch filter,ANF)的双馈风电场时变次同步振荡抑制策略。首先,分析ANF安装于风机转子侧变流器(rotor-side converter,RSC)不同位置时对次同步振荡分量的阻断效果,确定ANF的最佳安装位置;其次,基于紧缩技术近似投影子空间跟踪算法(projection approximation subspace tracking based on the deflation technique,PASTd)在线获取次同步振荡信息,提出总体控制架构,设计基于量测数据辨识的ANF中心频率更新策略;最终,在考虑风速、风机台数、无功出力、电网拓扑变化等多种影响因素的情况下,验证控制策略对频率时变次同步振荡的抑制效果。与现有方法相比,所提控制策略不依赖于系统的准确数学模型,且具备较强的鲁棒性和适应性。展开更多
基金supported by the Science and Technology Project of State Grid Corporation of China(5100202199536A-0-5-ZN)。
文摘The penetration of new energy sources such as wind power is increasing,which consequently increases the occurrence rate of subsynchronous oscillation events.However,existing subsynchronous oscillation source-identification methods primarily analyze fixed-mode oscillations and rarely consider time-varying features,such as frequency drift,caused by the random volatility of wind farms when oscillations occur.This paper proposes a subsynchronous oscillation sourcelocalization method that involves an enhanced short-time Fourier transform and a convolutional neural network(CNN).First,an enhanced STFT is performed to secure high-resolution time-frequency distribution(TFD)images from the measured data of the generation unit ports.Next,these TFD images are amalgamated to form a subsynchronous oscillation feature map that serves as input to the CNN to train the localization model.Ultimately,the trained CNN model realizes the online localization of subsynchronous oscillation sources.The effectiveness and accuracy of the proposed method are validated via multimachine system models simulating forced and natural oscillation events using the Power Systems Computer Aided Design platform.Test results show that the proposed method can localize subsynchronous oscillation sources online while considering unpredictable fluctuations in wind farms,thus providing a foundation for oscillation suppression in practical engineering scenarios.
基金Supported by National Natural Science Foundation of China(Grant No51506108)
文摘Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors ofrotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two hearings respectively are discovered. As the outer clearance of SFRB increases from 24 ~tm to 60 pro, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close.
基金supported by the National Key R&D Pro gram (2017YFB0902901)National Nature Science Founda tion of China (51725702, 51627811, 51707064)。
文摘Owing to the large-scale grid connection of new energy sources, several installed power electronic devices introduce sub-/supersynchronous inter-harmonics into power signals, resulting in the frequent occurrence of subsynchronous oscillations(SSOs). The SSOs may cause significant harm to generator sets and power systems;thus, online monitoring and accurate alarms for power systems are crucial for their safe and stable operation. Phasor measurement units(PMUs) can realize the dynamic real-time monitoring of power systems. Based on PMU phasor measurements, this study proposes a method for SSO online monitoring and alarm implementation for the main station of a PMU. First, fast Fourier transform frequency spectrum analysis is performed on PMU current phasor amplitude data to obtain subsynchronous frequency components. Second, the support vector machine learning algorithm is trained to obtain the amplitude threshold and subsequently filter out safe components and retain harmful ones. Finally, the adaptive duration threshold is determined according to frequency susceptibility, amplitude attenuation, and energy accumulation to decide whether to transmit an alarm signal. Experiments based on field data verify the effectiveness of the proposed method.
基金supported by National Natural Science Foundation of China(No.52077004).
文摘The subsynchronous oscillations(SSOs)related to renewable generation seriously affect the stability and safety of the power systems.To realize the dynamic monitoring of SSOs by utilizing the high computational efficiency and noise-resilient features of the matrix pencil method(MPM),this paper propos es an improved MPM-based parameter identification with syn chrophasors.The MPM is enhanced by the angular frequency fitting equations based on the characteristic polynomial coeffi cients of the matrix pencil to ensure the accuracy of the identi fied parameters,since the existing eigenvalue solution of the MPM ignores the angular frequency conjugation constraints of the two fundamental modes and two oscillation modes.Then,the identification and recovery of bad data are proposed by uti lizing the difference in temporal continuity of the synchropha sors before and after noise reduction.The proposed parameter identification is verified with synthetic,simulated,and actual measured phase measurement unit(PMU)data.Compared with the existing MPM,the improved MPM achieves better accuracy for parameter identification of each component in SSOs,better real-time performance,and significantly reduces the effect of bad data.
文摘In this paper,proposals in the following arcas of turbogenerator torsionaloscillation(TTO)researches in China are presented:* Concerning the focal points of TTO studies;* Concerning the modelling and data acquisition of TTO;* Concerning the computation and analysis of TTO transients;* Concerning the monitoring and analyzing devices of TTO;* Concerning the countermeasures against TTO.It is concluded that researches centered on torsional oscillations caused by system dis-turbances and switching events should begin the carlier the better.
文摘At present,the direct drive permanent magnet synchronous generator(DD-PMSG)grid connected system based on virtual synchronous generator(VSG)control will experience power oscillation at sub synchronous frequencies.The mechanism and characteristics of this new type of sub-synchronous interaction(SSI)are not yet clear,and the system cannot recover to steady state solely based on the characteristics of VSG itself.Especially when connected to a weak current network,oscillations are more pronounced,affecting the stability of the system.In severe cases,the systemmay trigger shutdown protection and be disconnected from the network.Existing research has only analyzed the oscillation mechanism under this phenomenon and has not proposed corresponding control strategies.This article proposes aVSM control strategy based on the VSG control algorithm,which balances the dq axis component of voltage and current,and improves the voltage and current loop of VSG control to reduce the impact of sub-synchronous oscillation(SSO)on the power grid.In MATLAB/Simulink,a simulation model of the proposed control strategy was built to verify its correctness and effectiveness.
基金National Key Research and Development Program of China under Grant No.2017YFB0902002.
文摘With the rapid development of wind power, wind turbines are accompanied by a large quantity of power electronic converters connected to the grid, causing changes in the characteristics of the power system and leading to increasingly serious sub-synchronous oscillation (SSO) problems, which urgently require the generalized classification and characterization of the emerging oscillation problems. This paper classifies and characterizes the emerging types of SSO caused by grid-connected wind turbines to address these issues. Finally, the impact of the typical system parameters changes on the oscillation pattern is analyzed in depth to provide effective support for the subsequent suppression and prevention of SSO.
文摘双馈风电场经串补电容并网时,可能引发次同步控制相互作用(subsynchronous control interaction,SSCI),严重威胁系统安全稳定运行。通过在风机控制器中引入陷波器可有效阻断SSCI,然而固定参数陷波器难以适应实际系统中次同步振荡表现出的频率大范围时变特征。为解决这一问题,该文提出一种基于改进自适应陷波(adaptive notch filter,ANF)的双馈风电场时变次同步振荡抑制策略。首先,分析ANF安装于风机转子侧变流器(rotor-side converter,RSC)不同位置时对次同步振荡分量的阻断效果,确定ANF的最佳安装位置;其次,基于紧缩技术近似投影子空间跟踪算法(projection approximation subspace tracking based on the deflation technique,PASTd)在线获取次同步振荡信息,提出总体控制架构,设计基于量测数据辨识的ANF中心频率更新策略;最终,在考虑风速、风机台数、无功出力、电网拓扑变化等多种影响因素的情况下,验证控制策略对频率时变次同步振荡的抑制效果。与现有方法相比,所提控制策略不依赖于系统的准确数学模型,且具备较强的鲁棒性和适应性。