期刊文献+
共找到274篇文章
< 1 2 14 >
每页显示 20 50 100
Analysis of 17β-Estadiol from Sewage in Coastal Marine Environment by Surface Plasmon Resonance Technique 被引量:6
1
作者 ZHANG Wei-wei CHEN Yu-chun +2 位作者 LUO Zhao-feng WANG Ju-ying MA De-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2007年第4期404-407,共4页
In this study, surface plasmon resonance (SPR) for monitoring 17β-eatradiol (E2) was developed. The small molecule E2 was immobilized on a CM5 sensor chip for an indirect competitive immunoassay to detect E2. The... In this study, surface plasmon resonance (SPR) for monitoring 17β-eatradiol (E2) was developed. The small molecule E2 was immobilized on a CM5 sensor chip for an indirect competitive immunoassay to detect E2. The SPR response bahed on the antigen-antibody reaction was measured by injecting the sample solution into the flow system. The limitation of detection was 0.445 μg/L. The developed SPE-SPR system was applied to analyze the seawater samples. Recovery of E2 was 91.6%-93. 1%. Relative standard deviations(RSD) for the E2 assay were between 10.9%-15.1% (n = 3). The range of determination of E2 samples from the sewage in the coastal marine environ-ment was between ND(lower than detection limit) and ca. 11.78 ng/L. 展开更多
关键词 Surface plasmon resonance (spr 17Β-ESTRADIOL IMMUNOASSAY SPE
下载PDF
Detection of Penicillin via Surface Plasmon Resonance Biosensor 被引量:2
2
作者 ZHANG Ying JIN Wei +7 位作者 YANG Meng-chao ZHANG Ti-qiang ZHOU Chao XIE Fei SONG Qi REN Hao JIN Qin-han MU Ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第5期792-796,共5页
A method of using Au colloid to capture the decomposed product of penicillin, penicillamine, on a surface plasmon resonance(SPR) biosensor for the quantitative determination of penicillin was developed. Based on the... A method of using Au colloid to capture the decomposed product of penicillin, penicillamine, on a surface plasmon resonance(SPR) biosensor for the quantitative determination of penicillin was developed. Based on the de-composition of penicillin to generate penicillamine and penilloaldehyde, a high sensitive biosensor for detecting penicillin was also developed. In our experiment, it was penicillamine rather than penicillin that has been measured. This is because penicillamine contains a functional group that makes it self-assembling on Au colloid to increase the molecular weight so as to improve the surface plasmon resonance signal. On a UV-Vis spectrophotometer, a high concentration of penicilliamine-Au complex was determined, indicating that penicillamine was already well combined with Au colloid. The method, using the combination of Au colloid with penicillamine, proved to detect penicillin. 展开更多
关键词 Surface plasmon resonance(spr) BIOSENSOR PENICILLAMINE Au colloid
下载PDF
Advances in Phase Detection Technique of Surface Plasmon Resonance Biosensor 被引量:1
3
作者 Yu Xinglong Wei Xing Deng Yan Liu Fangfang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期299-304,共6页
Surface plasmon resonance (SPR) sensing is an optical method based on evanescent wave.SPR biosensor can detect interaction of label-free biomolecules in real-time.With further development,it can become a research ins... Surface plasmon resonance (SPR) sensing is an optical method based on evanescent wave.SPR biosensor can detect interaction of label-free biomolecules in real-time.With further development,it can become a research instrument in proteomics.SPR biosensor can be divided intensity measurement and phase measurement,and the latter possesses higher sensitivity than the former one.This paper attempts to summarize the SPR phase detection theory,discuss the major developments,compare the merits and deficiencies of various methods,and look forward to future prospects. 展开更多
关键词 surface plasmon resonance(spr) phase detection ELLIPSOMETRY HETERODYNE INTERFEROMETRY
下载PDF
Fiber cladding dual channel surface plasmon resonance sensor based on S-type fiber 被引量:1
4
作者 魏勇 赵晓玲 +6 位作者 刘春兰 王锐 蒋天赐 李玲玲 石晨 刘纯彪 竺栋 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期187-195,共9页
Fiber cladding surface plasmon resonance(SPR)sensors have few structures,and a clad SPR sensor based on S-type fiber is proposed in this paper.This new type of fiber cladding SPR sensor was formed by electrofusing an ... Fiber cladding surface plasmon resonance(SPR)sensors have few structures,and a clad SPR sensor based on S-type fiber is proposed in this paper.This new type of fiber cladding SPR sensor was formed by electrofusing an S-shaped structure on the fiber to couple the light in the fiber core to the cladding.In this paper,the effects of fiber parameters on the performance of the sensor were studied by simulation and experiment.Based on the conclusion that the smaller the core diameter is,the closer the working band of the SPR resonance is to long wavelengths,and that the geometric characteristics mean that a multimode fiber can receive the fiber cladding light from a small core diameter few-mode fiber,a dual channel SPR sensor with a double S-type fiber cascade was proposed.In the refractive index detection range of 1.333–1.385refractive index units(RIU),the resonant working band of channel I is 627.66 nm–759.78 nm,with an average sensitivity of 2540.77 nm/RIU,and the resonant working band of channel II is 518.24 nm–658.2 nm,with an average sensitivity of2691.54 nm/RIU.The processing method for the S-type fiber cladding SPR sensor is simple,effectively solving the problem of this type of SPR sensor structure and the difficult realization of a dual channel.The sensor is expected to be used in the fields of medical treatment and biological analysis. 展开更多
关键词 surface plasmon resonance(spr) S-type structure dual channel cladding fiber spr sensor
下载PDF
Dual-channel fiber-optic surface plasmon resonance sensor with cascaded coaxial dual-waveguide D-type structure and microsphere structure 被引量:1
5
作者 李玲玲 魏勇 +4 位作者 刘春兰 任卓 周爱 刘志海 张羽 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期201-208,共8页
To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-typ... To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-type structure and microsphere structure is proposed in this paper. The fiber sidepolishing technique converts the coaxial dual-waveguide fiber into a D-type one, and the evanescent wave in the ring core leaks, generating a D-type sensing region;the fiber optic fused ball push technology converts the coaxial dual waveguides into microspheres, and the stimulated cladding mode evanescent wave leaks, producing the microsphere sensing region. By injecting light into the coaxial dual-waveguide middle core alone, the sensor can realize single-stage sensing in the microsphere sensing area;it can also realize dual-channel sensing in the D-type sensing area and microsphere sensing area by injecting light into the ring core. The refractive index measurement ranges for the two channels are 1.333–1.365 and 1.375–1.405, respectively, with detection sensitivities of 981.56 nm/RIU and 4138 nm/RIU. The sensor combines wavelength division multiplexing and space division multiplexing technologies, presenting a novel research concept for multi-channel fiber SPR sensors. 展开更多
关键词 coaxial dual-waveguide optical fiber D structure optical fiber microsphere structure dual-channel fiber-optic surface plasmon resonance(spr)sensor
下载PDF
Characteristics of Surface Plasmon Resonance Imaging lnterferometer
6
作者 Wei Xing Deng Yan Liu Fangfang Yu Xinglong 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期595-599,共5页
In recent life science research,identifying and characterizing entire biomolecular interaction networks is prerequisite to understanding cellular processes on a molecular and biophysical level.A surface plasmon resona... In recent life science research,identifying and characterizing entire biomolecular interaction networks is prerequisite to understanding cellular processes on a molecular and biophysical level.A surface plasmon resonance (SPR) imaging interferometer based on spatial phase modulation detection is presented to meet this demand.In this method,the SPR sensing chip surface is illuminated with collimated parallel light beam,and a Wollaston prism is introduced into the reflected light path to produce the interference of polarized light reflected from SPR sensing chip.Information of biomolecular interactions can be obtained by extracting the phase change from the SPR interference patterns.Using our interferometer,we made experiments on a series concentration of NaCl solutions to investigate its detection range,linearity,sensitivity and resolution.The results indicate that the SPR imaging interferometer is mainly sufficient for biomolecular interaction detection. 展开更多
关键词 surface plasmon resonance(spr) detection range LINEARITY sensitivity RESOLUTION
下载PDF
Surface plasmon resonance sensor based on molecularly imprinted films for the detection of pentaerythritol tetranitrate (PETN)
7
作者 ZHANG Qing-wen BAO Han +4 位作者 ZHAO Feng-qin BAO Si-miao WEI Tian-xin ZHANG Peng CUI He 《Journal of Beijing Institute of Technology》 EI CAS 2014年第1期126-130,共5页
A novel surface plasmon resonance (SPR) sensor based on molecularly imprinted films (MIFs) was developed for the detection of pentaerythritol tetranitrate (PETN). In this work, the thin MIFs were formed on a gol... A novel surface plasmon resonance (SPR) sensor based on molecularly imprinted films (MIFs) was developed for the detection of pentaerythritol tetranitrate (PETN). In this work, the thin MIFs were formed on a gold sensor chip through thermal co-polymerization of functional mono- mers (methacrylic acid, MAA) and crosslinking monomers (ethylene glycol dimethacrylate, EGD- MA) in the presence of template molecules PETN. The template molecules PETN were subsequently removed from the MIFs simply by rinsing the MIFs with a mixture of acetonitrile and acetic acid 9:1 ( v/v), thus the recognition sites were formed for specific detection of PETN. According to the mass coverage equation, the surface coverage of removed PETN from MIFs was about 10. 8 ng/mm~. The developed SPR sensor allowed for the detection of PETN at concentration down to 10-~~ mol/L. A control experiment utilizing an analogue cyclotrimethylenetrinitramine (RDX) showed MIFs' good selectivity to PETN. 展开更多
关键词 surface plasmon resonance (spr molecularly imprinted films (MIFs) pentaerythritoltetranitrate (PETN)
下载PDF
Improvement of the Specificity of Surface Plasmon Resonance with BSA-modified Chip
8
作者 Li Hua CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第12期1619-1622,共4页
A chip was modified with bovine serum albumin (BSA), then interaction between glutathione (GSH) immobilized on the top of BSA and glutathione-S-transferase (GST) was examined, using surface plasmon resonance (... A chip was modified with bovine serum albumin (BSA), then interaction between glutathione (GSH) immobilized on the top of BSA and glutathione-S-transferase (GST) was examined, using surface plasmon resonance (SPR). The SPR results showed that BSA-modified chip was effective not only in binding the target proteins but also in suppressing the nonspecific binding (NSB) of proteins. 展开更多
关键词 Surface plasmon resonance (spr bovine serum albumin (BSA) glutathione (GSH) glutathione-S-trans ferase (GST).
下载PDF
Development and Application of Time-Resolved Surface Plasmon Resonance Spectrometer
9
作者 Yan Mao Yu Bao +3 位作者 Wei Wang Zhenggang Li Fenghua Li Li Niu 《American Journal of Analytical Chemistry》 2011年第5期589-604,共16页
Surface plasmon resonance (SPR) sensor, an optical sensor exploiting special electromagnetic waves-surface plasmon polaritons to probe interactions between an analyte in solution and a molecular recognition element im... Surface plasmon resonance (SPR) sensor, an optical sensor exploiting special electromagnetic waves-surface plasmon polaritons to probe interactions between an analyte in solution and a molecular recognition element immobilized on the SPR sensor surface, has been widely used in various realms, such as investigating biomolecular interactions and binding properties, detection of biological and chemical analytes, environmental monitoring, food safety and medical diagnostics. This paper reviews the development of SPR sensors and SPR commercial instruments, and emphatically introduces the time-resolved surface plasmon resonance (TR-SPR) techniques. The excellent performances of high sensitivity and rapid detection are easily achieved with TR-SPR spectrometer, whereas the traditional SPR spectrometer cannot be accomplished. Therefore, TR-SPR spectrometer is appropriate for real time analysis of bio-recognition events and small molecular dynamics. However, only two commercial TR-SPR instruments have been exhibited at present, Thermo FT-SPR 100 and Autolab ESPRIT (SPRINGLE). Unfortunately, the high-priced instruments are not suitable for extensive applications in laboratories at present. Herein, a novel commercial TR-SPR spectrometer has been introduced in this review. 展开更多
关键词 SURFACE Alasmon resonance TIME-RESOLVED SURFACE plasmon resonance spr Sensor TIME-RESOLVED Measurement
下载PDF
基于SPR的重金属离子检测技术研究进展 被引量:1
10
作者 刘小锐 邱娉 +5 位作者 刘倩 陈嘉杰 王雪亮 戴小祺 黄松锋 邵永红 《光学仪器》 2024年第4期1-13,共13页
重金属离子浓度的检测对于人体健康和环境科学等领域具有重要意义。与其它离子检测方法相比,表面等离子体共振(surface plasmon resonance,SPR)技术具有无标记,灵敏度高和检测限低等优点,为重金属离子监测领域带来了新的可能性。本文综... 重金属离子浓度的检测对于人体健康和环境科学等领域具有重要意义。与其它离子检测方法相比,表面等离子体共振(surface plasmon resonance,SPR)技术具有无标记,灵敏度高和检测限低等优点,为重金属离子监测领域带来了新的可能性。本文综述了SPR传感技术在重金属离子检测中的应用及其技术进展。首先介绍了SPR传感的技术原理;然后在传感材料的选择以及表面修饰等方面,针对铅、汞等有害重金属离子,重点阐述了对灵敏度、线性动态范围和特异性等指标的改进;最后介绍了SPR成像传感技术在检测速度、灵敏度等方面取得的重大进展,展望了SPR技术的发展前景。 展开更多
关键词 表面等离子体共振 光学传感器 重金属离子 spr成像
下载PDF
波长型SPR检测仪的灵敏度探讨 被引量:5
11
作者 李海波 徐抒平 +2 位作者 刘钰 菅晓光 徐蔚青 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2010年第11期2157-2161,共5页
利用自行设计构建的可变入射角的波长型表面等离子体共振(SPR)检测仪,在不同浓度的蔗糖溶液中测定了不同入射角度(80°~66°)的共振曲线,经过处理得到共振峰位、半高宽及灵敏度随入射角和样品折射率变化的三维图像.在此基础上... 利用自行设计构建的可变入射角的波长型表面等离子体共振(SPR)检测仪,在不同浓度的蔗糖溶液中测定了不同入射角度(80°~66°)的共振曲线,经过处理得到共振峰位、半高宽及灵敏度随入射角和样品折射率变化的三维图像.在此基础上探讨了波长型SPR检测仪的主要参数对仪器性能的影响,从理论和实验上证明了影响灵敏度的主要因素为共振波长,并且随着共振波长的增大,检测灵敏度迅速提高. 展开更多
关键词 表面等离子体共振(spr) 波长型spr检测仪 灵敏度 入射角 共振波长
下载PDF
SPR生物传感器及其应用进展 被引量:25
12
作者 程慧 黄朝峰 段子渊 《中国生物工程杂志》 CAS CSCD 2003年第5期46-49,共4页
基于表面等离子体共振 (SPR)技术的光学生物传感器是进行生物分子相互作用分析的一种先进手段。与传统的超速离心、荧光法等相比 ,它具有实时检测、无需标记、耗样最少等特点 ,在药物筛选、临床诊断、食物及环境监控和膜生物学等领域中... 基于表面等离子体共振 (SPR)技术的光学生物传感器是进行生物分子相互作用分析的一种先进手段。与传统的超速离心、荧光法等相比 ,它具有实时检测、无需标记、耗样最少等特点 ,在药物筛选、临床诊断、食物及环境监控和膜生物学等领域中的新兴应用日益扩大 ,并且已成为生命科学和制药研究的一种标准的生物物理学工具。综述了近几年国际上生物传感器的应用进展情况 。 展开更多
关键词 spr生物传感器 表面等离子体共振 光学生物传感器 生物分子相互作用分析
下载PDF
SPR免疫竞争法研究小分子吗啡与其抗体间作用的动力学特征 被引量:4
13
作者 陈受惠 崔小强 +2 位作者 杨帆 倪永年 杨秀荣 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2003年第10期1770-1774,共5页
表面等离子体共振技术 ( SPR)主要应用于生物大分子相互作用的研究 ,本文采用溶液竞争法 ,测定了小分子吗啡与其抗体作用的结合常数 K1,并计算了吗啡抗体与吗啡化牛血清白蛋白的结合常数 K2 .证明了多抗对抗原的亲和力较单抗大 ,并表明... 表面等离子体共振技术 ( SPR)主要应用于生物大分子相互作用的研究 ,本文采用溶液竞争法 ,测定了小分子吗啡与其抗体作用的结合常数 K1,并计算了吗啡抗体与吗啡化牛血清白蛋白的结合常数 K2 .证明了多抗对抗原的亲和力较单抗大 ,并表明大分子蛋白质的存在对抗体与待测物的结合有阻碍作用 . 展开更多
关键词 表面等离子体共振 动力学 吗啡 溶液竞争法 免疫分析 抗体 止痛剂
下载PDF
SPR生物传感器检测牛奶中氨苄青霉素残留 被引量:6
14
作者 苏洋 张婉洁 +2 位作者 徐可欣 刘瑾 石婷 《传感器与微系统》 CSCD 北大核心 2010年第11期40-42,47,共4页
将表面等离子体共振(SPR)传感器的高灵敏性与抗原抗体的高亲和性相结合,通过自组装分子技术将抗生素的单克隆抗体固定到传感器金膜表面,用于特异性吸附牛奶中的抗生素,实现了抗生素残留的快速、痕量检测。由于牛奶的成分复杂,在测量过... 将表面等离子体共振(SPR)传感器的高灵敏性与抗原抗体的高亲和性相结合,通过自组装分子技术将抗生素的单克隆抗体固定到传感器金膜表面,用于特异性吸附牛奶中的抗生素,实现了抗生素残留的快速、痕量检测。由于牛奶的成分复杂,在测量过程中牛奶中的某些成分产生的非特异性固定引入了极大的测量误差。因此,对牛奶进行了脱脂和稀释预处理,通过实验比对发现,对牛奶进行脱脂并稀释4倍后,其产生的非特异性固定基本消除,接近了纯水的测量水平。最后,对预处理后的牛奶进行了多浓度测量,并建立了不同浓度的氨苄青霉素牛奶样品的工作曲线。所采用传感器的最低测量限(LOD)达到了1.56μg/L(变异系数为7.8%),低于欧盟规定的牛奶中氨苄青霉素的最低检出限。 展开更多
关键词 抗生素残留 表面等离子体共振 免疫测定 抗体 牛奶
下载PDF
一种高精度SPR生物传感器的设计与实现 被引量:7
15
作者 杨军 王敏 +3 位作者 李圆怡 战磊 吴松 胡宁 《传感器与微系统》 CSCD 北大核心 2010年第7期96-98,102,共4页
表面等离体共振(SPR)技术被广泛应用于表面检测、生化免疫分析、药物筛选和环境监测等领域。介绍一种自行设计的基于Kretschmann结构的角度检测型SPR生物传感器。该装置采用角度连续扫描的方式,利用2个独立的步进电机分别驱动固定有棱... 表面等离体共振(SPR)技术被广泛应用于表面检测、生化免疫分析、药物筛选和环境监测等领域。介绍一种自行设计的基于Kretschmann结构的角度检测型SPR生物传感器。该装置采用角度连续扫描的方式,利用2个独立的步进电机分别驱动固定有棱镜和光电检测器件的大小转盘,可以进行单一样本的高精度分析。测试结果表明:该传感器具有很高的重复性与稳定性,噪声小、精度高。 展开更多
关键词 表面等离体共振 Kretschmann结构 转角式 生物传感器
下载PDF
SPR传感器的应用及其发展 被引量:10
16
作者 王颖娜 常丽萍 郭淑琴 《材料导报》 EI CAS CSCD 北大核心 2012年第9期32-36,共5页
表面等离子共振(SPR)传感器是一项新兴的生物化学检测技术,具有灵敏度高、检测方便快捷、可实现在线检测等许多优点,可广泛应用于材料科学、环境保护、食品工业等直接关系人类生存发展的诸多领域。首先介绍了SPR传感器的发展历史及其工... 表面等离子共振(SPR)传感器是一项新兴的生物化学检测技术,具有灵敏度高、检测方便快捷、可实现在线检测等许多优点,可广泛应用于材料科学、环境保护、食品工业等直接关系人类生存发展的诸多领域。首先介绍了SPR传感器的发展历史及其工作原理,然后综述了SPR传感器的结构和分类,具体包括棱镜耦合式SPR传感器、集成光波导耦合式SPR传感器、光纤SPR传感器和光栅耦合式SPR传感器的结构,着重描述了SPR传感器的最新发展趋势,重点介绍了分布式SPR传感器、光纤SERS传感器的发展状况。 展开更多
关键词 spr传感器 表面等离子体共振 棱镜 光波导 光栅
下载PDF
表面激元共振(SPR)传感器理论分析 被引量:10
17
作者 刘国华 文可 牛文成 《仪表技术与传感器》 CSCD 北大核心 2003年第11期1-3,共3页
在基于ATR方法的SPR传感器设计和制作的工作中,为了得到更加优化的性能,对其原理进行了较为深入的分析。从表面激元波和全反射消逝波的数学模型入手,得到了共振角的数学关系及几个结论,并以金膜为例进行了计算机仿真。
关键词 传感器 表面激元共振 表面激元波 衰减全反射 消逝波
下载PDF
纳米金标记抗体增强SPR检测大肠杆菌O157∶H7 被引量:8
18
作者 刘霞 李蓉卓 +2 位作者 李蕾 李文进 周春娇 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2013年第6期1333-1338,共6页
将金纳米粒子(AuNPs)标记的大肠杆菌O157∶H7(E.coli O157∶H7)的多克隆抗体(PAb)作为二抗,采用氨基偶联法将PAb固定在传感器表面作为一抗,通过三明治方法用双通道表面等离子体子共振(SPR)传感器对E.coli O157∶H7进行检测,并与SPR直接... 将金纳米粒子(AuNPs)标记的大肠杆菌O157∶H7(E.coli O157∶H7)的多克隆抗体(PAb)作为二抗,采用氨基偶联法将PAb固定在传感器表面作为一抗,通过三明治方法用双通道表面等离子体子共振(SPR)传感器对E.coli O157∶H7进行检测,并与SPR直接法检测进行了比较.结果表明,直接法的检出限为103cfu/mL,线性范围为103~109cfu/mL;AuNPs增强三明治法的检出限为10 cfu/mL,线性范围为10~1010cfu/mL,灵敏度比直接法提高了100倍,且具有更宽的检测范围.本方法不仅检测时间短,而且具有良好的选择性和重现性. 展开更多
关键词 金纳米粒子 大肠杆菌O157∶H7 表面等离子体子共振 标记 检测
下载PDF
Au纳米粒子表面等离子共振效应(SPR)增强Au/Bi_2WO_6异质纳米结构的光催化活性 被引量:5
19
作者 王丹军 王婵 +4 位作者 赵强 郭莉 杨晓 吴娇 付峰 《无机材料学报》 SCIE EI CAS CSCD 北大核心 2018年第6期659-666,共8页
采用水热-光还原法在三维Bi_2WO_6的二级结构纳米片表面原位沉积Au纳米粒子(Au NPs),成功获得了具有可见光响应活性的Au/Bi_2WO_6异质光催化剂,并借助XRD、FE-SEM、HR-TEM、XPS和UV-Vis-DRS谱等手段对其物相组成、形貌和光吸收特性进行... 采用水热-光还原法在三维Bi_2WO_6的二级结构纳米片表面原位沉积Au纳米粒子(Au NPs),成功获得了具有可见光响应活性的Au/Bi_2WO_6异质光催化剂,并借助XRD、FE-SEM、HR-TEM、XPS和UV-Vis-DRS谱等手段对其物相组成、形貌和光吸收特性进行表征,以罗丹明B(Rh B)和苯酚为模型污染物对其光催化性能进行研究。实验结果表明,与纯Bi_2WO_6相比,所得Au/Bi_2WO_6异质纳米结构对染料降解具有较高的活性,当Au负载量为1.5at%时,Au/Bi_2WO_6复合催化剂的催化活性最好,其光催化降解Rh B和苯酚的表观速率常数分别是纯Bi_2WO_6的1.5倍和2.2倍。自由基捕获实验表明,光生空穴(h+)和?O2–是Rh B在Au/Bi_2WO_6催化材料上光催化降解的主要活性物种。机理分析表明,Au/Bi_2WO_6活性增强归因于光生电子从Bi_2WO_6的导带向Au NPs表面迁移,降低光生电子–空穴对的复合率,同时,Au NPs的等离子共振效应(SPR)拓展了催化剂在可见光区的响应范围,从而显著提高了Au/Bi_2WO_6异质光催化的剂活性。Au NPs修饰Bi_2WO_6异质催化剂光太阳能驱动在污水处理方面具有潜在应用。 展开更多
关键词 Au/Bi2WO6异质纳米结构 光催化剂 光还原法 电子转移 等离子共振效应(spr)
下载PDF
利用SPR生物传感器检测缺血修饰白蛋白 被引量:6
20
作者 李广 陈龙聪 +3 位作者 李贤 杨萌 陈萌梦 熊兴良 《传感器与微系统》 CSCD 北大核心 2014年第1期144-146,156,共4页
缺血修饰白蛋白(IMA)的检测对心肌缺血的早期诊断和治疗具有重要意义。利用纳米金颗粒和混合巯基自组装于金膜表面上,研制了一种快速检测IMA的表面等离子体共振(SPR)生物传感器。同时比较了直接法和抑制法的检测下限。结果表明:直接检... 缺血修饰白蛋白(IMA)的检测对心肌缺血的早期诊断和治疗具有重要意义。利用纳米金颗粒和混合巯基自组装于金膜表面上,研制了一种快速检测IMA的表面等离子体共振(SPR)生物传感器。同时比较了直接法和抑制法的检测下限。结果表明:直接检测法可以检测到393ng/L的IMA,而抑制检测法检测限小于5.0 ng/L。与现有的IMA检测方法相比,SPR生物传感器具有特异性好、检测下限低以及检测耗时短等优点。 展开更多
关键词 表面等离子体共振 混合巯基自组装 缺血修饰白蛋白 纳米金
下载PDF
上一页 1 2 14 下一页 到第
使用帮助 返回顶部