The separation method using chiral stationary phase (CSP) for the preparation of enantioselective compound was widely used. In this work, supercritical fluid chromatography(SFC) was proposed to resolve the chiral ...The separation method using chiral stationary phase (CSP) for the preparation of enantioselective compound was widely used. In this work, supercritical fluid chromatography(SFC) was proposed to resolve the chiral mixtures. To determine the optimum operating conditions for the chiral separation of the racemic ibuprofen, the retention factors and resolutions with the change in pressure, temperature and the content of IPA (%, by volume) in supercritical CO2 were investigated. Experiments showed that the retention factor decreased with the increase of pressure and decrease in temperature. The retention factor was also influenced by the content of IPA in mobile phase, as the content of IPA in the supercritical fluid increased, the retention factor decreased. The resolution of the enantiomers became worse with the increase of IPA in the supercritical fluid. Through optimizing the experimental conditions, a SFC procedure with 13MPa, 311.15K and 4% IPA in CO2 was obtained. The peak shape of the enantiomers was symmetric with supercritical fluid chromatography when compared to the asymmetric peak shape obtained by the conventional liquid chromatography. This work demonstrated that the developed supercritical fluid chromatography procedure was suitable for the chiral separation of ibuprofen enantiomers.展开更多
A packed column supercritical fluid chromatography (SFC) method for the separation of clopidogrel enantiomers on a chiral stationary phase and CO2 with modifier as mobile phase has been developed at an analytical scal...A packed column supercritical fluid chromatography (SFC) method for the separation of clopidogrel enantiomers on a chiral stationary phase and CO2 with modifier as mobile phase has been developed at an analytical scale. Among 11 different 2 stationary phases the Chiral cel OD-H column showed by far the best separation properties. The influence of different modifiers, injection solvents, temperature, and pressure, and density of the fluid, respectively, on the separation behaviour has been studied. It was found that the separation behaviour strongly depends on the type of modifier and the modifier content. Temperature and pressure are of less influence.展开更多
Crosslinking experin(?)tnts for the chiral stationary phase OV-225-L-Val-t-butylamide within both fused silica and glass capillary columns have been carried out.Amino acid enantiomers were separated on crosslinked col...Crosslinking experin(?)tnts for the chiral stationary phase OV-225-L-Val-t-butylamide within both fused silica and glass capillary columns have been carried out.Amino acid enantiomers were separated on crosslinked columns by、both GC and SFC methods.In SFC,the α values of amino acid enantiomers are independent of the density of the mobile phase,and they are hig her than those obtained by GC for the tested enantiomers with the same column due to the lower column tempera- ture used in SFC.展开更多
文摘The separation method using chiral stationary phase (CSP) for the preparation of enantioselective compound was widely used. In this work, supercritical fluid chromatography(SFC) was proposed to resolve the chiral mixtures. To determine the optimum operating conditions for the chiral separation of the racemic ibuprofen, the retention factors and resolutions with the change in pressure, temperature and the content of IPA (%, by volume) in supercritical CO2 were investigated. Experiments showed that the retention factor decreased with the increase of pressure and decrease in temperature. The retention factor was also influenced by the content of IPA in mobile phase, as the content of IPA in the supercritical fluid increased, the retention factor decreased. The resolution of the enantiomers became worse with the increase of IPA in the supercritical fluid. Through optimizing the experimental conditions, a SFC procedure with 13MPa, 311.15K and 4% IPA in CO2 was obtained. The peak shape of the enantiomers was symmetric with supercritical fluid chromatography when compared to the asymmetric peak shape obtained by the conventional liquid chromatography. This work demonstrated that the developed supercritical fluid chromatography procedure was suitable for the chiral separation of ibuprofen enantiomers.
文摘A packed column supercritical fluid chromatography (SFC) method for the separation of clopidogrel enantiomers on a chiral stationary phase and CO2 with modifier as mobile phase has been developed at an analytical scale. Among 11 different 2 stationary phases the Chiral cel OD-H column showed by far the best separation properties. The influence of different modifiers, injection solvents, temperature, and pressure, and density of the fluid, respectively, on the separation behaviour has been studied. It was found that the separation behaviour strongly depends on the type of modifier and the modifier content. Temperature and pressure are of less influence.
基金This work was supported by the National Natural Science Fundation of China.
文摘Crosslinking experin(?)tnts for the chiral stationary phase OV-225-L-Val-t-butylamide within both fused silica and glass capillary columns have been carried out.Amino acid enantiomers were separated on crosslinked columns by、both GC and SFC methods.In SFC,the α values of amino acid enantiomers are independent of the density of the mobile phase,and they are hig her than those obtained by GC for the tested enantiomers with the same column due to the lower column tempera- ture used in SFC.