A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magne...A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments.展开更多
The effectiveness of the magnetic confinement of plasma can be improved by elongat- ing the plasma cross-section in tokamak devices. But elongated plasma has vertical displacement instability, so a feedback control sy...The effectiveness of the magnetic confinement of plasma can be improved by elongat- ing the plasma cross-section in tokamak devices. But elongated plasma has vertical displacement instability, so a feedback control system is needed to restrain the plasma's vertical displacement. A fast control power supply is needed to excite the active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, the fast control power supply needs to keep on enhancing the fast response and output current. The structure of a new power supply is introduced in this paper. The method of multiple inverters paralleled with the current sharing reactor is presented to meet the need for large current and fast control. According to the design demands of the EAST fast control power supply, the adjuster of the current close loop is applied to the inverter, which can advance its ability to restrain the loop current in low frequency and DC output. The result of the experiment confirms the validity of the proposed scheme and control strategy.展开更多
A simple water iodizing system, which incorporates the Venturi principle in combination with the controlled release mechanism of a silicone-sodium iodide elastomer, for the iodization of rural piped-water supply in th...A simple water iodizing system, which incorporates the Venturi principle in combination with the controlled release mechanism of a silicone-sodium iodide elastomer, for the iodization of rural piped-water supply in the control of endemic iodine deficiency has been developed and its effectiveness evaluated in three Iban longhouse villages in the iodinedeficient district of Lubok Antu, Sarawak. Urines were collected for iodine assays from women aged 15-40 years before and at 6 and 12 months after the connection of the iodinating device; goiter assessment was performed on the women at the start and end of the 1-year study. Water samples were collected for iodine assays at 2-weekly intervals. In all three villages, significant and sustained increases in median urinary iodine excretions,reaching levels recommended for an iodine-suffcient population, were observed; goitre prevalences were reduced in all the villages (by 22.6% to 35.8%). The iodine levels in the water ranged from 34 μg/l to 212 μg/L. In the control village, median urinary iodine excretions remained essentially unchanged but a small increase in goiter prevalence was observed. The iodized water was well received by the villagers and no adverse effects of water iodization were observed. The system functioned unattended throughout the one year period. The cost of providing supplemental iodine via the iodizing device is approximately 60 cents (U.S.) per family per year which is affordable by either the Government or the villagers. It is concluded that the iodizing system offers a new cost-effective strategy for the control of endemic iodine deficiency in Sarawak and may have applications in other areas with similar water sources展开更多
In the project Wendelstein 7-X (W7-X), the popular fieldbus Profibus has been determined as a uniform connection between the central control system and all the subordinate systems. A universal embedded control system ...In the project Wendelstein 7-X (W7-X), the popular fieldbus Profibus has been determined as a uniform connection between the central control system and all the subordinate systems. A universal embedded control system has been developed for W7-X power supply controlling. Siemens 80C167CR microcontroller is used as the central control unit of the system. With a user-defined printed circuit board (PCB) several control buses, i.e., Profibus, CAN, IEEE 488, RS485 and RS 232 have been connected to the microcontroller. The corresponding hardware interfaces for the control buses have been designed. A graphic liquid crystal display(LCD) and a user-defined keyboard are used as user interface. The control software will be developed with a C-like language, i.e., C166 for the controller.展开更多
EAST (experimental advanced superconducting tokamak) fast control power supply is a high-capacity single-phase AC/DC/AC inverter power supply, which traces the displacement signal of plasma, and excites coils in a v...EAST (experimental advanced superconducting tokamak) fast control power supply is a high-capacity single-phase AC/DC/AC inverter power supply, which traces the displacement signal of plasma, and excites coils in a vacuum vessel to produce a magnetic field that realizes plasma stabilization. To meet the requirements of a large current and fast response, the multi- ple structure of the carrier phase-shift three-level inverter is presented, which realizes parallelled multi-inverters, raises the equivalent switching frequency of the inverters and improves the per- formance of output waves. In this work the design scheme is analyzed, and the output harmonic characteristic of parallel inverters is studied. The simulation and experimental results confirm that the scheme and control strategy is valid. The power supply system can supply a large current, and has a perfect performance on harmonic features as well as the ability of a fast response.展开更多
The paper deals with control of supply in pipe networks based on so-called Dynamic Virtual Distortion Method. Making use of the analytical network model of this installation and using presented below, the so-called Vi...The paper deals with control of supply in pipe networks based on so-called Dynamic Virtual Distortion Method. Making use of the analytical network model of this installation and using presented below, the so-called Virtual Distortion Method (VDM), the control of water supply can be performed. Minimization of supply pressure in inlets to the network, subject to inequality constraints imposed on outlet pressure (in chosen nodes) is discussed. Taking advantage of pre-computed influence vectors, the real-time control strategy can be realised with small computational effort and therefore, can be managed with use of hardware-based controllers. Non-linear constitutive relation (water flow vs. pressure head) has been assumed.展开更多
Manufacturing system, with high level of complexity and with a mix of semi-repetitive and repetitive products, to become productive, should seek the standardization of products and processes to obtain the optimization...Manufacturing system, with high level of complexity and with a mix of semi-repetitive and repetitive products, to become productive, should seek the standardization of products and processes to obtain the optimization of use of production resources. However, it is necessary to measure the productivity, so that the system of measurement and control of manufacturing processes are an element critical as to ensure greater visibility of the flow's restrictions, minimized when detected properly. In this case, the automation of factory's measurement process can effectively contribute to ensuring the effectiveness of the function control of a manufacturing system. It is important to consider that the automation of the system of measurement and control of manufacturing processes, of complex environment, is heavily dependent of IT tools applied directly in the interface computational between the operation systems and the corporate systems. This heavy reliance, if exploited technically properly, allows that automation of the system of measurement and control of production makes the access to time real of availability of manufacturing process's data, such as processing time and setup time that it can export to a specialist software in programming production, for example, feasible. In this paper, the automation of the system of measurement and control of production is approached, in order to identify the main possibilities of the design of an information system capable to integrate the flow of information in an environment internal on manufacturing organizations, with emphasis in the digital manufacturing paradigm.展开更多
In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the con...In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the construction of the high performance computer (HPC) system, the plasma configuration real-time reconstruction with EFIT code, the immigration of plasma simulation codes, the improvement of the poloidal field control system with circulating current, the design of the new data acquiring device with higher anti-disturbing power, the new software on soft X-ray spectrum measurement providing the multi-channel Te evolution, the upgrade to the HL-2A data storage system and experimental net. On the other hand, according to the arrangement of HL-2A modification project, a series of designs such as new plasma configuration, poloidal field coils distribution and plasma shape and position control system are on the processing.展开更多
In order to satisfy the requirement of ECRH for power supply, pulse high voltage ( HV ) power supply has been developed. The main parameters of the power are: output voltage -55 kV, output current 25 -2 A, stabilit...In order to satisfy the requirement of ECRH for power supply, pulse high voltage ( HV ) power supply has been developed. The main parameters of the power are: output voltage -55 kV, output current 25 -2 A, stability ±0.5%, pulse duration 1 s, the leading edge and lagging edge of the pulse is about 40 μs and so on. On the other hand, the system should have preferable protective capability. In this paper, the hardware and principle of the power supply, hardware, software and arithmetic method of the control system are presented.展开更多
Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power ...Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved.展开更多
The superconducting quadrupole magnets (SCQs) are powered by 16 power supplies in the inter- action region of the BEPC Ⅱ. The control application of these power supplies must be interlocked with the quench protecti...The superconducting quadrupole magnets (SCQs) are powered by 16 power supplies in the inter- action region of the BEPC Ⅱ. The control application of these power supplies must be interlocked with the quench protection system to protect the superconducting magnet and relevant devices. This paper describes the development procedures of this control application using EPICS and the operating result with the quench protection system on-site.展开更多
Thermodynamic characteristics are of great importance for the performance of a high-temperature flow-rate control valve,as high-temperature environment may bring problems,such as blocking of spool and increasing of le...Thermodynamic characteristics are of great importance for the performance of a high-temperature flow-rate control valve,as high-temperature environment may bring problems,such as blocking of spool and increasing of leakage,to the valve.In this paper,a high-temperature flow-rate control valve,pilot-controlled by a pneumatic servo system is developed to control the fuel supply for scramjet engines.After introducing the construction and working principle,the thermodynamic mathematical models of the valve are built based on the heat transfer methods inside the valve.By using different boundary conditions,different methods of simulations are carried out and compared.The steady-state and transient temperature field distribution inside the valve body are predicted and temperatures at five interested points are measured.By comparing the simulation and experimental results,a reasonable 3D finite element analysis method is suggested to predict the thermodynamic characteristics of the high-temperature flow-rate control valve.展开更多
Purpose The digital controller for the accelerator magnet power supply typically employs a field-programmable gate array(FPGA)as the signal processing chip for executing digital processing of closed-loop control.Curre...Purpose The digital controller for the accelerator magnet power supply typically employs a field-programmable gate array(FPGA)as the signal processing chip for executing digital processing of closed-loop control.Currently,FPGA chips are predominantly utilized in Intel or Xilinx products.To address the“key areas and stranglehold”issue pertaining to FPGA chips in accelerator power supply,we have devised a digital power supply prototype using a domestic FPGA chip and validated its feasibility in the upgrade project’s magnet power supply digital transformation plan for the Beijing Electron Positron Collider(BEPCII).Method A domestic FPGA chip from the Seal5000 SA5Z-30-D1 series by Xi’an ZhiDuoJing Microelectronics Co.serves as the core component for the design of a digital corrector magnet power supply to replace the existing analog controlled corrector power supply at BEPCII.The power supply’s digital control of the closed loop is achieved through the use of a hardware description language,and the digital controller hardware is constructed based on the original power supply power topology.Results and conclusions After conducting experiments and tests on the power supply prototype,we have successfully met the current operational requirements of the BEPCII corrector power supply,thus confirming the feasibility of utilizing domestic FPGA for digital application on accelerator power supply.展开更多
基金supported by ITER Program of China(973 Program)(No.2011GB109002)National Natural Science Foundation of China(No.11275056)Hefei University of Technology Doctor Research Foundation of China(No.2011HGBZ1292)
文摘A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments.
基金supported in part by the ITER Program of China(973 Program)(No.2011GB109002)National Natural Science Foundation of China(No.11275056)
文摘The effectiveness of the magnetic confinement of plasma can be improved by elongat- ing the plasma cross-section in tokamak devices. But elongated plasma has vertical displacement instability, so a feedback control system is needed to restrain the plasma's vertical displacement. A fast control power supply is needed to excite the active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, the fast control power supply needs to keep on enhancing the fast response and output current. The structure of a new power supply is introduced in this paper. The method of multiple inverters paralleled with the current sharing reactor is presented to meet the need for large current and fast control. According to the design demands of the EAST fast control power supply, the adjuster of the current close loop is applied to the inverter, which can advance its ability to restrain the loop current in low frequency and DC output. The result of the experiment confirms the validity of the proposed scheme and control strategy.
文摘A simple water iodizing system, which incorporates the Venturi principle in combination with the controlled release mechanism of a silicone-sodium iodide elastomer, for the iodization of rural piped-water supply in the control of endemic iodine deficiency has been developed and its effectiveness evaluated in three Iban longhouse villages in the iodinedeficient district of Lubok Antu, Sarawak. Urines were collected for iodine assays from women aged 15-40 years before and at 6 and 12 months after the connection of the iodinating device; goiter assessment was performed on the women at the start and end of the 1-year study. Water samples were collected for iodine assays at 2-weekly intervals. In all three villages, significant and sustained increases in median urinary iodine excretions,reaching levels recommended for an iodine-suffcient population, were observed; goitre prevalences were reduced in all the villages (by 22.6% to 35.8%). The iodine levels in the water ranged from 34 μg/l to 212 μg/L. In the control village, median urinary iodine excretions remained essentially unchanged but a small increase in goiter prevalence was observed. The iodized water was well received by the villagers and no adverse effects of water iodization were observed. The system functioned unattended throughout the one year period. The cost of providing supplemental iodine via the iodizing device is approximately 60 cents (U.S.) per family per year which is affordable by either the Government or the villagers. It is concluded that the iodizing system offers a new cost-effective strategy for the control of endemic iodine deficiency in Sarawak and may have applications in other areas with similar water sources
文摘In the project Wendelstein 7-X (W7-X), the popular fieldbus Profibus has been determined as a uniform connection between the central control system and all the subordinate systems. A universal embedded control system has been developed for W7-X power supply controlling. Siemens 80C167CR microcontroller is used as the central control unit of the system. With a user-defined printed circuit board (PCB) several control buses, i.e., Profibus, CAN, IEEE 488, RS485 and RS 232 have been connected to the microcontroller. The corresponding hardware interfaces for the control buses have been designed. A graphic liquid crystal display(LCD) and a user-defined keyboard are used as user interface. The control software will be developed with a C-like language, i.e., C166 for the controller.
基金supported by Key Project of National Ninth Five-Year Research Program of China[(1998)1303]
文摘EAST (experimental advanced superconducting tokamak) fast control power supply is a high-capacity single-phase AC/DC/AC inverter power supply, which traces the displacement signal of plasma, and excites coils in a vacuum vessel to produce a magnetic field that realizes plasma stabilization. To meet the requirements of a large current and fast response, the multi- ple structure of the carrier phase-shift three-level inverter is presented, which realizes parallelled multi-inverters, raises the equivalent switching frequency of the inverters and improves the per- formance of output waves. In this work the design scheme is analyzed, and the output harmonic characteristic of parallel inverters is studied. The simulation and experimental results confirm that the scheme and control strategy is valid. The power supply system can supply a large current, and has a perfect performance on harmonic features as well as the ability of a fast response.
文摘The paper deals with control of supply in pipe networks based on so-called Dynamic Virtual Distortion Method. Making use of the analytical network model of this installation and using presented below, the so-called Virtual Distortion Method (VDM), the control of water supply can be performed. Minimization of supply pressure in inlets to the network, subject to inequality constraints imposed on outlet pressure (in chosen nodes) is discussed. Taking advantage of pre-computed influence vectors, the real-time control strategy can be realised with small computational effort and therefore, can be managed with use of hardware-based controllers. Non-linear constitutive relation (water flow vs. pressure head) has been assumed.
文摘Manufacturing system, with high level of complexity and with a mix of semi-repetitive and repetitive products, to become productive, should seek the standardization of products and processes to obtain the optimization of use of production resources. However, it is necessary to measure the productivity, so that the system of measurement and control of manufacturing processes are an element critical as to ensure greater visibility of the flow's restrictions, minimized when detected properly. In this case, the automation of factory's measurement process can effectively contribute to ensuring the effectiveness of the function control of a manufacturing system. It is important to consider that the automation of the system of measurement and control of manufacturing processes, of complex environment, is heavily dependent of IT tools applied directly in the interface computational between the operation systems and the corporate systems. This heavy reliance, if exploited technically properly, allows that automation of the system of measurement and control of production makes the access to time real of availability of manufacturing process's data, such as processing time and setup time that it can export to a specialist software in programming production, for example, feasible. In this paper, the automation of the system of measurement and control of production is approached, in order to identify the main possibilities of the design of an information system capable to integrate the flow of information in an environment internal on manufacturing organizations, with emphasis in the digital manufacturing paradigm.
文摘In 2006, except the basic improvement on HL-2A tokamak control system, data acquisition and processing system, a series of research activities have been developed in computer and control division. They include the construction of the high performance computer (HPC) system, the plasma configuration real-time reconstruction with EFIT code, the immigration of plasma simulation codes, the improvement of the poloidal field control system with circulating current, the design of the new data acquiring device with higher anti-disturbing power, the new software on soft X-ray spectrum measurement providing the multi-channel Te evolution, the upgrade to the HL-2A data storage system and experimental net. On the other hand, according to the arrangement of HL-2A modification project, a series of designs such as new plasma configuration, poloidal field coils distribution and plasma shape and position control system are on the processing.
文摘In order to satisfy the requirement of ECRH for power supply, pulse high voltage ( HV ) power supply has been developed. The main parameters of the power are: output voltage -55 kV, output current 25 -2 A, stability ±0.5%, pulse duration 1 s, the leading edge and lagging edge of the pulse is about 40 μs and so on. On the other hand, the system should have preferable protective capability. In this paper, the hardware and principle of the power supply, hardware, software and arithmetic method of the control system are presented.
基金supported by the National Natural Science Founda-tion under Grant No. 50771089 and No.10802029
文摘Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved.
文摘The superconducting quadrupole magnets (SCQs) are powered by 16 power supplies in the inter- action region of the BEPC Ⅱ. The control application of these power supplies must be interlocked with the quench protection system to protect the superconducting magnet and relevant devices. This paper describes the development procedures of this control application using EPICS and the operating result with the quench protection system on-site.
文摘Thermodynamic characteristics are of great importance for the performance of a high-temperature flow-rate control valve,as high-temperature environment may bring problems,such as blocking of spool and increasing of leakage,to the valve.In this paper,a high-temperature flow-rate control valve,pilot-controlled by a pneumatic servo system is developed to control the fuel supply for scramjet engines.After introducing the construction and working principle,the thermodynamic mathematical models of the valve are built based on the heat transfer methods inside the valve.By using different boundary conditions,different methods of simulations are carried out and compared.The steady-state and transient temperature field distribution inside the valve body are predicted and temperatures at five interested points are measured.By comparing the simulation and experimental results,a reasonable 3D finite element analysis method is suggested to predict the thermodynamic characteristics of the high-temperature flow-rate control valve.
基金National Natural Science Foundation of China(12005236).
文摘Purpose The digital controller for the accelerator magnet power supply typically employs a field-programmable gate array(FPGA)as the signal processing chip for executing digital processing of closed-loop control.Currently,FPGA chips are predominantly utilized in Intel or Xilinx products.To address the“key areas and stranglehold”issue pertaining to FPGA chips in accelerator power supply,we have devised a digital power supply prototype using a domestic FPGA chip and validated its feasibility in the upgrade project’s magnet power supply digital transformation plan for the Beijing Electron Positron Collider(BEPCII).Method A domestic FPGA chip from the Seal5000 SA5Z-30-D1 series by Xi’an ZhiDuoJing Microelectronics Co.serves as the core component for the design of a digital corrector magnet power supply to replace the existing analog controlled corrector power supply at BEPCII.The power supply’s digital control of the closed loop is achieved through the use of a hardware description language,and the digital controller hardware is constructed based on the original power supply power topology.Results and conclusions After conducting experiments and tests on the power supply prototype,we have successfully met the current operational requirements of the BEPCII corrector power supply,thus confirming the feasibility of utilizing domestic FPGA for digital application on accelerator power supply.