期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The role of echocardiography in mini-invasive surgical device closure of ventricular septal defect
1
作者 张纯 《外科研究与新技术》 2011年第3期171-171,共1页
Objective To assess the application of echocardiography in mini-invasive surgical device closure of ventricular septal defect (VSD) . Methods 73 VSD patients including 35 with aneurysm formation and among them 21 with... Objective To assess the application of echocardiography in mini-invasive surgical device closure of ventricular septal defect (VSD) . Methods 73 VSD patients including 35 with aneurysm formation and among them 21 with multi-defects in the aneurysm were treated by mini-invasive device closure. A closure device was positioned to the defect through parasternal mini-incision in all patients. TEE was used to monitor the whole procedure。 展开更多
关键词 The role of echocardiography in mini-invasive surgical device closure of ventricular septal defect
下载PDF
Selection of approach and fixation in the treatment of type C fracture of distal humerus in adults 被引量:1
2
作者 齐欣 刘建国 +3 位作者 宫宇宝 杨晨 李叔强 冯卫 《Chinese Journal of Traumatology》 CAS 2010年第3期163-166,共4页
Objective:To study the surgical treatment for distal humeral fractures in adults according to the follow-up results.Methods: Twenty-one cases (16 males and 5 females)of distal humeral fracture were included in thi... Objective:To study the surgical treatment for distal humeral fractures in adults according to the follow-up results.Methods: Twenty-one cases (16 males and 5 females)of distal humeral fracture were included in this study. The average age was 42.5 years (range: 37-52 years). Fractures were classified according to the AO classification system.Nine cases of C1,8 C2 and 4 C3-type fractures were identified.Open reduction and internal fixation were performed in all cases. A tricep-reflecting approach was adopted, and either the AO orthogonal plating or parallel plating technique was chosen,based on the fracture type. The plaster cast was removed 3 weeks after operation. Rehabilitation was encouraged during this period and afterwards. The average follow-up time was 12.2 months (range: 8-28 months). The outcome was scored according to Aitken and Rorabeek system.Results:No nerve injury,nonunion or failure of fixation was encountered during the operation and follow-up.However, ossifying myosifis occurred in one case.Conclusions:A triceps-reflecting approach can provide adequate exposure to the joint. The use of AO orthogohal plating or parallel plating techniques based on the type of fractures can provide rigid fixation for the fracture. 展开更多
关键词 Humeral fractures Intra-articular fractures surgical fixation devices
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部