We report that fully transparent resistive random access memory (TRRAM) devices based on ITO/TiO2/ITO sandwich structure, which are prepared by the method of RF magnetron sputtering, exhibit excellent switching stab...We report that fully transparent resistive random access memory (TRRAM) devices based on ITO/TiO2/ITO sandwich structure, which are prepared by the method of RF magnetron sputtering, exhibit excellent switching stability. In the visible region (400 800 nm in wavelength) the TRRAM device has a transmittance of more than 80%. The fabricated TRRAM device shows a bipolar resistance switching behaviour at low voltage, while the retention test and rewrite cycles of more than 300,000 indicate the enhancement of switching capability. The mechanism of resistance switching is further explained by the forming and rupture processes of the filament in the TiO2 layer with the help of more oxygen vacancies which are provided by the transparent ITO electrodes.展开更多
The aim of this study was to develop a new pulsed switching peroxi-coagulation system to control hydroxyl radical(∙OH)production and to enhance 2,4-Dichlorophenoxyacetic acid(2,4-D)degradation.The system was construct...The aim of this study was to develop a new pulsed switching peroxi-coagulation system to control hydroxyl radical(∙OH)production and to enhance 2,4-Dichlorophenoxyacetic acid(2,4-D)degradation.The system was constructed with a sacrifice iron anode,a Pt anode,and a gas diffusion cathode.Production of H_(2)O_(2) and Fe^(2+)was controlled separately by time delayers with different pulsed switching frequencies.Under current densities of 5.0 mA/cm^(2)(H_(2)O_(2))and 0.5 mA/cm^(2)(Fe^(2+)),the∙OH production was optimized with the pulsed switching frequency of 1.0 s(H_(2)O_(2)):0.3 s(Fe^(2+))and the ratio of H_(2)O_(2) to Fe^(2+)molar concentrations of 6.6.Under the optimal condition,2,4-D with an initial concentration of 500 mg/L was completely removed in the system within 240 min.The energy consumption for the 2,4-D removal in the system was much lower than that in the electro-Fenton process(686 vs.13610 kWh/kg TOC).The iron consumption in the system was~20 times as low as that in the peroxi-coagulation process(19620 vs.3940400 mg/L)within 240 min.The system should be a promising peroxi-coagulation method for organic pollutants removal in wastewater.展开更多
The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to pro...The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction.展开更多
基金Project supported by the National Basic Research Program of China (Grant No. 2007CB925002)the National High Technology Research and Development Program of China (Grant No. 2008AA031401)and Chinese Academy of Sciences
文摘We report that fully transparent resistive random access memory (TRRAM) devices based on ITO/TiO2/ITO sandwich structure, which are prepared by the method of RF magnetron sputtering, exhibit excellent switching stability. In the visible region (400 800 nm in wavelength) the TRRAM device has a transmittance of more than 80%. The fabricated TRRAM device shows a bipolar resistance switching behaviour at low voltage, while the retention test and rewrite cycles of more than 300,000 indicate the enhancement of switching capability. The mechanism of resistance switching is further explained by the forming and rupture processes of the filament in the TiO2 layer with the help of more oxygen vacancies which are provided by the transparent ITO electrodes.
基金supported by grants from the National Key Scientific Instrument and Equipment Development Project(No.2012YQ03011108)research fund program of Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology(No.2016K0013)+1 种基金the National Natural Science Foundation of China(Grant Nos.51608547,51278500 and 51308557)the Fundamental Research Funds for the Central Universities(No.16lgjc65).
文摘The aim of this study was to develop a new pulsed switching peroxi-coagulation system to control hydroxyl radical(∙OH)production and to enhance 2,4-Dichlorophenoxyacetic acid(2,4-D)degradation.The system was constructed with a sacrifice iron anode,a Pt anode,and a gas diffusion cathode.Production of H_(2)O_(2) and Fe^(2+)was controlled separately by time delayers with different pulsed switching frequencies.Under current densities of 5.0 mA/cm^(2)(H_(2)O_(2))and 0.5 mA/cm^(2)(Fe^(2+)),the∙OH production was optimized with the pulsed switching frequency of 1.0 s(H_(2)O_(2)):0.3 s(Fe^(2+))and the ratio of H_(2)O_(2) to Fe^(2+)molar concentrations of 6.6.Under the optimal condition,2,4-D with an initial concentration of 500 mg/L was completely removed in the system within 240 min.The energy consumption for the 2,4-D removal in the system was much lower than that in the electro-Fenton process(686 vs.13610 kWh/kg TOC).The iron consumption in the system was~20 times as low as that in the peroxi-coagulation process(19620 vs.3940400 mg/L)within 240 min.The system should be a promising peroxi-coagulation method for organic pollutants removal in wastewater.
基金Supported by the National Natural Science Foundation of China(60874100)
文摘The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction.